Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Chemical Imaging of Atmospheric Biomass Burning Particles from North American Wildfires

The effects of biomass burning aerosols (BBA) on radiative forcing and cloud formation depend on chemical composition and the internal structures of individual particles within smoke plumes. To improve our understanding of the chemical and physical properties of BBA emitted at different times of the day and their evolution during atmospheric aging, we conducted a study as a part of the Fire Influence on Regional to Global Environments and Air Quality field campaign. Particle samples were collected onboard a research aircraft from smoke plumes from a wildfire in eastern Oregon during late afternoon and nighttime flights on August 28, 2019. A time-resolved aerosol collector was used to collect samples on substrates for offline spectromicroscopic imaging to investigate the single-particle characteristics of BBA particles. Approximately 20,400 individual particles from 10 selected samples were analyzed using computer-controlled scanning electron microscopy coupled with energy-dispersive X-ray microanalysis, revealing their elemental composition, morphology, and viscosity. Elemental microanalysis indicated that aged potassium is likely found in the form of K 2 SO 4 , KNO 3 , and possible K-organic salts. Further chemical speciation and carbon bonding mapping within individual particles were conducted using synchrotron-based scanning transmission X-ray microscopy (STXM) coupled with near edge X-ray absorption fine structure (NEXAFS) spectroscopy. Real-time, water-soluble light absorption measurements were acquired using a particle-into-liquid sampler instrument coupled to a liquid waveguide capillary cell and total organic analyzer. In the late afternoon samples, 65% of the total particle number population consisted entirely of organic components, compared to 46% in the nighttime particles. These differences were attributed to discrepancies in composition at the time of emission and to the daytime condensation and accumulation of photochemically formed secondary organic material on existing BBA particles, a process that halts at night. Microscopy images indicated that particle viscosity was lower in the nighttime particles (<10 1 Pa·s), likely due to increased relative humidity and a higher contribution from hygroscopic inorganic components. The chemical heterogeneity of individual particles was quantified using STXM-derived mixing state parameters. The nature of carbon bonding within individual particles was inferred from the extent of carbon sp 2 hybridization derived from NEXAFS spectra. Average percentages of sp 2 hybridization range between 40% and 60%, with no noticeable differences between late afternoon and nighttime flights. These findings were compared with the online optical properties of both late afternoon and nighttime smoke plumes, providing valuable insights into the complex relationship between chemical composition and optical properties of BBA particles at different times of the day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlated spin-wave generation and domain-wall oscillation in a topologically textured magnetic film

Spin waves, or magnons, are essential for next-generation energy-efficient spintronics and magnonics. Yet, visualizing spin-wave dynamics at nanoscale and microwave frequencies remains a formidable challenge due to the lack of spin-sensitive, time-resolved microscopy. Here, in this study, we report a breakthrough in imaging dipole-exchange spin waves in a ferromagnetic film owing to the development of laser-free ultrafast Lorentz electron microscopy, which is equipped with a microwave-mediated electron pulser for high spatiotemporal resolution. Using topological spin textures, we captured the emission, propagation, reflection and interference of spin waves from spin anti-vortices under radio-frequency excitations. Remarkably, we show that spin-wave generation is closely tied to the oscillatory motion of specific magnetic domain walls, providing the missing link between wave emission and wall dynamics near magnetic singularities. This work opens new possibilities in magnonics, offering a nanoscopic view of spin dynamics via transmission electron microscopy and enabling controlled excitation via radio-frequency fields for exploring non-equilibrium states in magnetic and multiferroic systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Variability-selected Intermediate-mass Black Hole Candidates in Dwarf Galaxies from ZTF and WISE

While it is difficult to observe the first black hole seeds in the early universe, we can study intermediate-mass black holes (IMBHs) in local dwarf galaxies for clues about their origins. In this paper we present a sample of variability-selected active galactic nuclei (AGN) in dwarf galaxies using optical photometry from the Zwicky Transient Facility (ZTF) and forward-modeled mid-IR photometry of time-resolved Wide-field Infrared Survey Explorer (WISE) co-added images. We found that 44 out of 25,714 dwarf galaxies had optically variable AGN candidates and 148 out of 79,879 dwarf galaxies had mid-IR variable AGN candidates, corresponding to active fractions of 0.17% ± 0.03% and 0.19% ± 0.02%, respectively. We found that spectroscopic approaches to AGN identification would have missed 81% of our ZTF IMBH candidates and 69% of our WISE IMBH candidates. Only nine candidates have been detected previously in radio, X-ray, and variability searches for dwarf galaxy AGN. The ZTF and WISE dwarf galaxy AGN with broad Balmer lines have virial masses of 10 5 M ⊙ < M BH < 10 7 M ⊙ , but for the rest of the sample, BH masses predicted from host galaxy mass range between 10 5.2 M ⊙ < M BH < 10 7.25 M ⊙ . We found that only 5 of 152 previously reported variability-selected AGN candidates from the Palomar Transient Factory in common with our parent sample were variable in ZTF. We also determined a nuclear supernova fraction of 0.05% ± 0.01% yr -1 for dwarf galaxies in ZTF. Our ZTF and WISE IMBH candidates show the promise of variability searches for the discovery of otherwise hidden low-mass AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

Observation of a single protein by ultrafast X-ray diffraction

The idea of using ultrashort X-ray pulses to obtain images of single proteins frozen in time has fascinated and inspired many. It was one of the arguments for building X-ray free-electron lasers. According to theory, the extremely intense pulses provide sufficient signal to dispense with using crystals as an amplifier, and the ultrashort pulse duration permits capturing the diffraction data before the sample inevitably explodes. This was first demonstrated on biological samples a decade ago on the giant mimivirus. Since then, a large collaboration has been pushing the limit of the smallest sample that can be imaged. The ability to capture snapshots on the timescale of atomic vibrations, while keeping the sample at room temperature, may allow probing the entire conformational phase space of macromolecules. Here we show the first observation of an X-ray diffraction pattern from a single protein, that of Escherichia coli GroEL which at 14 nm in diameter is the smallest biological sample ever imaged by X-rays, and demonstrate that the concept of diffraction before destruction extends to single proteins. From the pattern, it is possible to determine the approximate orientation of the protein. Our experiment demonstrates the feasibility of ultrafast imaging of single proteins, opening the way to single-molecule time-resolved studies on the femtosecond timescale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved spray characterization via unified optical flow and binarization technique

This work leverages an unsupervised machine learning and advanced image processing techniques to characterize the breakup of fuel sprays in a small-scale combustor under reacting conditions, providing valuable insights into near-nozzle flow phenomenology. The proposed methodology integrates an improved optical flow model on a convolutional neural network to extract flow vectors with a binarization technique to assess droplets’ size and shape across the region of interest. The velocimetry approach demonstrates superior performance compared to a state-of-the-art optical flow model when applied to high-speed X-ray phase contrast spray images, achieving more accurate and reliable flow predictions. Moreover, breakup processes are quantified by breakup length and sphericity in accordance with velocity estimations, allowing a more complete characterization of the flow. This study establishes a robust methodology for analyzing spray morphology and primary breakup in compact combustors, contributing valuable means of understanding and optimizing fuel spray behavior in advanced combustion systems.

42 ENGINEERING↗

Simultaneous measurements of kinetic and scalar energy spectrum time evolution in the Richtmyer–Meshkov instability upon reshock

The Richtmyer–Meshkov instability (Richtmyer, Commun. Pure Appl. Maths , vol. 13, issue 2, 1960, pp. 297–319; Meshkov, Fluid Dyn. , vol. 4, issue 5, 1972, pp. 101–104) of a twice-shocked gas interface is studied using both high spatial resolution single-shot (SS) and lower spatial resolution, time-resolved, high-speed (HS) simultaneous planar laser-induced fluorescence and particle image velocimetry in the Wisconsin Shock Tube Laboratory's vertical shock tube. The initial condition (IC) is a shear layer with broadband diffuse perturbations at the interface between a helium–acetone mixture and argon. This IC is accelerated by a shock of nominal strength Mach number $M = 1.75$ , and then accelerated again by the transmitted shock that reflects off the end wall of the tube. An ensemble of experiments is analysed after reshock while the interface mixing width grows linearly with time. The kinetic and scalar energy spectra and the terms of their evolution equation are calculated and compared between SS and HS experiments. The inertial range scaling of the scalar power spectrum is found to follow Gibson's relation (Gibson, Phys. Fluids , vol. 11, issue 11, 1968, pp. 2316–2327) as a function of Schmidt number when the effective turbulent Schmidt number is used in place of the material Schmidt number that controls equilibrium scaling. Further, the spatially integrated scalar flux follows similar behaviour observed for the kinetic energy in large eddy simulation studies by Zeng et al. ( Phys. Fluids , vol. 30, issue 6, 2018, 064106) while the spatially varying scalar flux exhibits back scatter along the centre of the mixing layer and forward energy transfer in the spike and bubble regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

NucD-24 Nuclear Diagnostics Development: Time resolved 12 C-rhoR on GCD and NIS technology development for polar LOS and data quality [Slides]

The Neutron Imaging team is readying for the NIS2 polar LOS development and future improvements to data quality on all LOS given consistently higher yields at NIF. Next-gen nano guide scintillators for NIS2 and CMOS cameras to replace outdated CCDs will be studied. Digital image plates will be tested for better data quality on passive imaging systems. The transition into the ignition regime is expected to show a significant signature in the ablator areal density. In the marginal ignition regime, a decrease of 12C-rhoR (ablator areal density) is expected but once the burn propagation produces a shock and compresses the ablator the trend reverses. GCD with the PD-PMT can resolve this effect in the ablator areal density by a temporal shift in the carbon signal. To give quantitative results a calibration of the detector for the Hohlraum/TMP signal is needed. Shots using Al, Si, and Au pucks will yield the needed information to move forward with this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Photostability Analysis of Perovskite Solar Cells by Time-Evolving Photoluminescence Imaging

In this work we investigate reversible metastabilities and irreversible degradation due to light soaking of triple-cation mixed-halide perovskite p-i-n solar cells. We use spatially resolved luminescence imaging to document the spatial inhomogeneities that exist even in high-performance devices with median efficiencies >20%. We monitor light-soaking degradation in-situ using time-evolving photoluminescence images, electro-luminescence images, and transient photovoltage. Post-stress measurements of external quantum efficiency and Kelvin- probe force microscopy suggest that long-term degradation primarily affects electrode interfaces rather than the absorber layer.

electroluminescence↗

Strictly Enforcing Invertibility and Conservation in CNN-Based Super Resolution for Scientific Datasets

Abstract Recently, deep convolutional neural networks (CNNs) have revolutionized image “super resolution” (SR), dramatically outperforming past methods for enhancing image resolution. They could be a boon for the many scientific fields that involve imaging or any regularly gridded datasets: satellite remote sensing, radar meteorology, medical imaging, numerical modeling, and so on. Unfortunately, while SR-CNNs produce visually compelling results, they do not necessarily conserve physical quantities between their low-resolution inputs and high-resolution outputs when applied to scientific datasets. Here, a method for “downsampling enforcement” in SR-CNNs is proposed. A differentiable operator is derived that, when applied as the final transfer function of a CNN, ensures the high-resolution outputs exactly reproduce the low-resolution inputs under 2D-average downsampling while improving performance of the SR schemes. The method is demonstrated across seven modern CNN-based SR schemes on several benchmark image datasets, and applications to weather radar, satellite imager, and climate model data are shown. The approach improves training time and performance while ensuring physical consistency between the super-resolved and low-resolution data. Significance Statement Recent advancements in using deep learning to increase the resolution of images have substantial potential across the many scientific fields that use images and image-like data. Most image super-resolution research has focused on the visual quality of outputs, however, and is not necessarily well suited for use with scientific data where known physics constraints may need to be enforced. Here, we introduce a method to modify existing deep neural network architectures so that they strictly conserve physical quantities in the input field when “super resolving” scientific data and find that the method can improve performance across a wide range of datasets and neural networks. Integration of known physics and adherence to established physical constraints into deep neural networks will be a critical step before their potential can be fully realized in the physical sciences.

54 ENVIRONMENTAL SCIENCES↗

Imaging Three-Dimensional Molecular Structure and Dynamics with Multiparticle Covariance and Cumulant Coulomb Explosion Analysis

Coulomb explosion imaging (CEI) provides a direct means of imaging molecular geometry by correlating fragment ion momenta following the fragmentation of a molecular polycation. Here, we demonstrate the use of three-body covariance and four-body cumulant analysis to extract three-dimensional (3D) structural information from the X-ray-induced Coulomb explosion of tert-butyl iodide (C4H9I). Site-selective ionization at the iodine 4d edge with intense femtosecond soft X-ray pulses from an X-ray free-electron laser (XFEL) enables rapid charge buildup and molecular breakup. By correlating ionic fragments in the molecular frame, we isolate complete dissociation channels and reveal subtle structural changes, such as umbrella-type motion of the branched alkyl chain, during the ionization process. Comparison with point-charge simulations of the Coulomb explosion shows close agreement, validating the approach. Furthermore, these results establish covariance/cumulant mapping as a powerful strategy for imaging complex three-dimensional molecular structures and point the way toward time-resolved CEI using both XFEL and tabletop sources for capturing ultrafast structural dynamics.

Imaging↗

Measurements of electron temperature in high-energy-density plasmas using gated x-ray pinhole imaging

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Plasma-Bubble Imaging and Spectroscopy (Final Report)

The aim of this research was to capture time- and space-resolved behavior of breakdown initiation and development in water with gas bubbles injected between the electrodes when excited with microsecond voltage pulses. The results were directly compared to our previous results from a PCRF collaboration on the development of an electrical discharge in a gas bubble immersed in liquids with different conductivities when excited by nanosecond voltage pulses. For nanosecond regimes, cavitation seems to play a major role in plasma breakdown for low conductivities and discharge initiates at an electrode. On microsecond timescales, where cavitation does not play a role, it has been hypothesized that breakdown in water occurs first in bubbles on or near the electrodes, pre-existing or formed thermally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-harmonic spin-shearing interferometry for spatially resolved EUV magneto-optical spectroscopy

We present a method for achieving hyperspectral magnetic imaging in the extreme ultraviolet (EUV) region based on high-harmonic generation (HHG). By interfering two mutually coherent orthogonally-polarized and laterally-sheared HHG sources, we create an EUV illumination beam with spatially-dependent ellipticity. By placing a magnetic sample in the beamline and sweeping the relative time delay between the two sources, we record a spatially resolved interferogram that is sensitive to the EUV magnetic circular dichroism of the sample. This image contains the spatially-resolved magneto-optical response of the sample at each harmonic order, and can be used to measure the magnetic properties of spatially inhomogeneous magnetic samples.

Optics↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Development of limited-view tomography for measurement of Spray G plume direction and liquid volume fraction

Abstract The method for direct injection of fuel in the cylinder of an IC engines is important to high-efficiency and low-emission performance. Optical spray diagnostics plays an important role in understanding plume movement and interaction for multi-hole injectors, and providing baseline understanding used for computational optimization of fuel delivery. Traditional planar or line-of-sight diagnostics fail to capture the liquid distribution because of optical thickness concerns. This work proposes a high-speed (67 kHz) extinction imaging technique at various injector rotations coupled to computed tomography (CT) for time-resolved reconstruction of liquid volume fraction in three dimensions. The number of views selected and processing were based on synthetic (modeled) liquid volume fraction data where extinction and CT adequately reconstructed each plume. The exercise showed that for an 8-hole, symmetric-design injector (ECN Spray G), only three different views are enough to reproduce the direction of each plume, and particularly the mean plume direction. Therefore, the number of views was minimized for experiments to save expense. Measurements applying this limited-view technique confirm plume–plume variations also detected with mechanical patternation, while providing better spatial and temporal resolution than achieved previously. Uncertainties due to the limited view within pressurized spray chambers, the droplet size, and optically thick regions are discussed. Graphic abstract

42 ENGINEERING↗