Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Probing Distinctive Redox Mechanism in Ni-Rich Cathode Via Real-Time Quick X-Ray Absorption Spectroscopy

X-ray radiation damage on the measuring system has been a critical issue regularly for a long-time exposure to X-ray beam during the in operando characterizations, which is particularly severe when the applied X-ray energy is near the absorption edges (M, L, K, etc.) of the interest element. Here, to minimize the negative effects raised by beam radiation, we employ quick X-ray absorption spectroscopy (QXAS) to study the electrochemical reaction mechanism of a Ni-rich layered structure cathode for lithium-ion batteries. With the advanced QXAS technique, the electronic structure and local coordination environment of the transition metals (TMs) are monitored in-operando with limited radiation damage. Compared to the conventional step-mode X-ray absorption spectroscopy, the QXAS can provide more reliable oxidation state change and more detailed local structure evolutions surrounding TMs (Ni and Co) in Ni-rich layered oxides. By leveraging these advantages of QXAS, we demonstrated that the Ni dominates the electrochemical process with the Co being almost electrochemically inactive. Reversible Ni ions movement between TMs sites and Li sites is also revealed by the time-resolved QXAS technique.

25 ENERGY STORAGE↗

High-power few-cycle Cr:ZnSe mid-infrared source for attosecond soft x-ray physics

The development of mid-infrared, high-energy pulses of extremely short pulse duration is of great importance to the strong-field physics community, as it enables extension of the high-harmonic cutoff towards the keV range of photon energies. Here we demonstrate a C r 2 + : Z n S e laser amplifier delivering 7 mJ, 100 fs pulses at 1 kHz repetition rate and 2.4 µm central wavelength with excellent energy stability and beam quality. These pulses are post-compressed to 39 fs, 6.2 mJ, and 115 GW peak power in a novel nonlinear compression scheme. The laser system was used to generate coherent soft x-ray radiation up to 0.6 keV covering the entire water window, which is of high importance for bio-relevant applications. The obtained results open a wide range of applications in nonlinear optics, attosecond and strong-field physics, and remote sensing.

Leshchenko, Vyacheslav E. (ORCID:0000000199708559)↗

A Multifidelity and Multimodal Machine Learning Approach for Extracting Bonding Environments of Impurities and Dopants from X-ray Spectroscopies

Extended X-ray absorption fine structure (EXAFS) spectroscopy is crucial for determining the coordination environment of impurities and dopants; however, it requires difficult measurements. X-ray absorption near edge structure (XANES) spectroscopy and X-ray emission spectroscopy (XES) can be obtained easily but cannot be converted to determine structures. In this work we develop tools to map measured XANES to the EXAFS signal through machine learning, thereby facilitating the use of EXAFS structural-determination analyses on XANES data. Through the use of Deep Operator Networks (DeepONets), we are able to accurately predict the EXAFS spectrum between 6 and 14 Å -1 from the first 6 Å -1 (~100 eV) of the absorption spectrum of Cu 2+ substitutional defects in the Fe 3+ mineral hematite (a-Fe 2 O 3 ). This surprising finding implies that theoretical analyses of X-ray absorption spectra could be implemented that extract the same conclusions as high-quality EXAFS studies from spectra collected over a much smaller range of photon energies. To encourage similar efforts, the simulated x-ray spectra, machine learning, and fitting code is made publicly available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

Demonstration of an AI-driven workflow for dynamic x-ray spectroscopy

X-ray absorption near edge structure (XANES) spectroscopy is a powerful technique for characterizing the chemical state and symmetry of individual elements within materials, but requires collecting data at many energy points which can be time-consuming. While adaptive sampling methods exist for efficiently collecting spectroscopic data, they often lack domain-specific knowledge about the structure of XANES spectra. Here we demonstrate a knowledge-injected Bayesian optimization approach for adaptive XANES data collection that incorporates understanding of spectral features like absorption edges and pre-edge peaks. We show this method accurately reconstructs the absorption edge of XANES spectra using only 15–20% of the measurement points typically needed for conventional sampling, while maintaining the ability to determine the x-ray energy of the sharp peak after the absorption edge with errors less than 0.03 eV, the absorption edge with errors less than 0.1 eV; and overall root-mean-square errors less than 0.005 compared to traditionally sampled spectra. Our experiments on battery materials and catalysts demonstrate the method’s effectiveness for both static and dynamic XANES measurements, improving data collection efficiency and enabling better time resolution for tracking chemical changes. This approach advances the degree of automation in XANES experiments, reducing the common errors of under- or over-sampling points near the absorption edge and enabling dynamic experiments that require high temporal resolution or limited measurement time.

Bayesian optimization↗

The Instrument of the Imaging X-Ray Polarimetry Explorer

While X-ray spectroscopy, timing, and imaging have improved much since 1962 when the first astronomical nonsolar source was discovered, especially wi the launch of the Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer, and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, which in turn is a result of the fate of approved missions and because celestial X-ray sources appear less polarized than expected. Only one positive measurement has been available until now: the Orbiting Solar Observatory measured the polarization of the Crab Nebula in the 1970s. The advent of microelectronics techniques has allowed for designing a detector based on the photoelectric effect of gas in an energy range where the optics are efficient at focusing in X-rays. Here we describe the instrument, which is the major contribution of the Italian collaboration to the Small Explorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will launch in late 2021. The instrument is composed of three detector units based on this technique and a detector service unit. Three mirror modules provided by Marshall Space Flight Center focus X-rays onto the detectors. We show the technological choices, their scientific motivation, and results from the calibration of the instrument. IXPE will perform imaging, timing, and energy-resolved polarimetry in the 2–8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Insights into the broadband emission of the TeV blazar Mrk 501 during the first X-ray polarization measurements

Aims.We present the first multiwavelength study of Mrk 501 that contains simultaneous very-high-energy (VHE)γ-ray observations and X-ray polarization measurements from the Imaging X-ray Polarimetry Explorer (IXPE). Methods.We used radio-to-VHE data from a multiwavelength campaign carried out between March 1, 2022, and July 19, 2022 (MJD 59639 to MJD 59779). The observations were performed by MAGIC,Fermi-LAT,NuSTAR,Swift(XRT and UVOT), and several other instruments that cover the optical and radio bands to complement the IXPE pointings. We characterized the dynamics of the broadband emission around the X-ray polarization measurements through its multiband fractional variability and correlations, and compared changes observed in the polarization degree to changes seen in the broadband emission using a multi-zone leptonic scenario. Results.During the IXPE pointings, the VHE state is close to the average behavior, with a 0.2–1 TeV flux of 20%–50% of the emission of the Crab Nebula. Additionally, it shows low variability and a hint of correlation between VHEγ-rays and X-rays. Despite the average VHE activity, an extreme X-ray behavior is measured for the first two IXPE pointings, taken in March 2022 (MJD 59646 to 59648 and MJD 59665 to 59667), with a synchrotron peak frequency > 1 keV. For the third IXPE pointing, in July 2022 (MJD 59769 to 59772), the synchrotron peak shifts toward lower energies and the optical/X-ray polarization degrees drop. All three IXPE epochs show an atypically low Compton dominance in theγ-rays. The X-ray polarization is systematically higher than at lower energies, suggesting an energy stratification of the jet. While during the IXPE epochs the polarization angles in the X-ray, optical, and radio bands align well, we find a clear discrepancy in the optical and radio polarization angles in the middle of the campaign. Such results further support the hypothesis of an energy-stratified jet. We modeled broadband spectra taken simultaneous to the IXPE pointings, assuming a compact zone that dominates in the X-rays and the VHE band, and an extended zone stretching farther downstream in the jet that dominates the emission at lower energies.NuSTARdata allow us to precisely constrain the synchrotron peak and therefore the underlying electron distribution. The change between the different states observed in the three IXPE pointings can be explained by a change in the magnetization and/or the emission region size, which directly connects the shift in the synchrotron peak to lower energies with the drop in the polarization degree.

Astronomy & Astrophysics↗

A sensitive high repetition rate arrival time monitor for X-ray free electron lasers

X-ray free-electron laser sources enable time-resolved X-ray studies with unmatched temporal resolution. To fully exploit ultrashort X-ray pulses, timing tools are essential. However, new high repetition rate X-ray facilities present challenges for currently used timing tool schemes. Here we address this issue by demonstrating a sensitive timing tool scheme to enhance experimental time resolution in pump-probe experiments at very high pulse repetition rates. Our method employs a self-referenced detection scheme using a time-sheared chirped optical pulse traversing an X-ray stimulated diamond plate. By formulating an effective medium theory, we confirm subtle refractive index changes, induced by sub-milli-Joule intense X-ray pulses, that are measured in our experiment. The system utilizes a Common-Path-Interferometer to detect X-ray-induced phase shifts of the optical probe pulse transmitted through the diamond sample. Owing to the thermal stability of diamond, our approach is well-suited for MHz pulse repetition rates in superconducting linear accelerator-based free-electron lasers.

47 OTHER INSTRUMENTATION↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

In-situ synchrotron X-ray micro-diffraction investigation of ultra-low-strain deformation microstructure in laminated Ti-Al composites

An ultra-low-strain deformation microstructure was revealed for the first time non-destructively in the bulk interior of an annealed laminated Ti-Al composite-in the "fully recrystallized" Al layer-by a synchrotron-based micro-diffraction technique, namely differential aperture X-ray microscopy (DAXM), through real space mapping with a very high angular resolution (0.01 degrees). This ultra-low-strain deformation microstructure was found to result from the thermal stress, induced during cooling after annealing, due to the different coefficients of thermal expansion for the Ti and Al layers. The annealed sample was further tensile deformed to a strain of 1.66% and followed by in situ DAXM and analyzed by various misorientation mapping methods. The results pointed to the important effects of the initial microstructure and the interface constraint, as well as the grain size and crystal orientation, on the plastic deformation. A gradient in dislocation density from the layer interface to the center was found in the Al layer of the annealed sample, and this gradient increased slightly during tensile deformation. The variation of the dislocation density was further discussed based on the activation and interaction of dislocations in grains of different sizes and orientations during plastic deformation. The findings of this study provided valuable insights in understanding the constraint effect of the laminated metal composite and the design of novel composite materials. (c) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Crystallographic orientation↗