Search NASA⌕ Search

SEARCH · Search NASA

Results for “axions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Warm inflation with a heavy QCD axion

We propose the first model of warm inflation in which the particle production emerges directly from coupling the inflaton to Standard Model particles. Warm inflation, an early epoch of sustained accelerated expansion at finite temperature, is a compelling alternative to cold inflation, with distinct predictions for inflationary observables such as the amplitude of fluctuations, the spectral tilt, the tensor-to-scalar ratio, and non-gaussianities. In our model a heavy QCD axion acts as the warm inflaton whose coupling to Standard Model gluons sources the thermal bath during warm inflation. Axion-like couplings to non-Abelian gauge bosons have been considered before as a successful microphysical theory with emerging thermal friction that can maintain finite temperature during inflation via sphaleron heating. However, the presence of light fermions charged under the non-Abelian group suppresses particle production, hindering a realization of warm inflation by coupling to QCD. We point out that the Standard Model quarks can be heavy during warm inflation if the Higgs field resides in a high-energy second minimum which restores efficient sphaleron heating. A subsequent large reheating temperature is required to allow the Higgs field to relax to its electroweak minimum. Exploring a scenario in which hybrid warm inflation provides the large reheating temperature, we show that future collider and beam dump experiments have discovery potential for a heavy QCD axion taking the role of the warm inflaton.

79 ASTRONOMY AND ASTROPHYSICS↗

Theory of stimulated and spontaneous axion scattering.

We present a theory for nonlinear, resonant excitation of dynamical axions by counterpropagating electromagnetic waves in materials that break both 𝒫 and 𝒯 symmetries. We show that dynamical axions can mediate an exponential growth in the amplitude of the lower frequency (Stokes) beam. We also discuss spontaneous generation of a counterpropagating Stokes mode, enabled by resonant amplification of quantum and thermal fluctuations in the presence of a single pump laser. Remarkably, the amplification can be orders of magnitude larger than that obtained via stimulated Brillouin and Raman scattering processes, and can be modulated with the application of external magnetic fields, making stimulated axion scattering promising for optoelectronics applications.

Smith, M.↗

High- Q Microwave Dielectric Resonator for Axion Dark-Matter Haloscopes

The frequency band 1–15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high-quality factor cavities that tolerate multitesla fields plays a central role. We report a three-dimensional resonator based on a right-circular copper cavity with hollow cylinders that confine higher-order modes around the cylinder axis. Its effective volume at 10.3 GHz is 3.4 × 10 − 2 l, and under an 8-T field we measure an internal quality factor of more than nine million. A fine-tuning system limited to approximately 1 -MHz range is tested, useful for understanding the conditions required to run a haloscope with a cavity exceeding the axion quality factor. The cavity parameters we report demonstrate the potential of this unique resonator to probe galactic dark-matter axion at scan rates exceeding 2 MHz/day when the cavity is readout by a quantum-limited receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic axion insulating behavior in antiferromagnetic MnBi 6 Te 10

A striking feature of time-reversal symmetry (TRS) protected topological insulators (TIs) is that they are characterized by a half integer quantum Hall effect on the boundary when the surface states are gapped by time-reversal breaking perturbations. While TRS-protected TIs have become increasingly under control, magnetic analogs are still a largely unexplored territory with novel rich structures. In particular, magnetic topological insulators can also host a quantized axion term in the presence of lattice symmetries. Since these symmetries are naturally broken on the boundary, the surface states can develop a gap without external manipulation. In this work, we combine theoretical analysis, density-functional calculations and experimental evidence to reveal intrinsic axion insulating behavior in MnBi 6 Te 10 . Additionally, the quantized axion term arises from the simplest possible mechanism in the antiferromagnetic regime where it is protected by inversion symmetry and the product of a fractional translation and TRS. The anticipated gapping of the Dirac surface state at the edge is subsequently experimentally established using angle resolved photoemission spectroscopy (ARPES). As a result, this system provides the magnetic analog of the simplest TRS-protected TI with a single, gapped Dirac cone at the surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamical piezomagnetic effect in time-reversal-invariant Weyl semimetals with axionic charge density waves

Charge density waves (CDWs) in Weyl semimetals (WSMs) have been shown to induce an exotic axionic insulating phase in which the sliding mode (phason) of the CDW acts as a dynamical axion field, giving rise to a large positive magnetoconductance. In this work, we predict that dynamical strain can induce a bulk orbital magnetization in time-reversal (TR)-invariant WSMs that are gapped by a CDW. Here, we term this effect the “dynamical piezomagnetic effect” (DPME). Unlike in J. Gooth et al., the DPME introduced in this work occurs in a bulk-constant (i.e., static and spatially homogeneous in the bulk) CDW, and does not rely on fluctuations, such as a phason. By studying the low-energy effective theory and a minimal tight-binding (TB) model, we find that the DPME originates from an effective valley axion field that couples the electromagnetic gauge field with a strain-induced pseudogauge field. In particular, whereas the piezoelectric effects studied in previous works are characterized by 2D Berry curvature, the DPME represents the first example of a fundamentally 3D strain effect originating from the Chern-Simons 3-form. We further find that the DPME has a discontinuous change at a critical value of the phase of the CDW order parameter. We demonstrate that, when there is a jump in the DPME, the surface of the system undergoes a topological quantum phase transition (TQPT), while the bulk remains gapped. Hence, the DPME provides a bulk signature of the boundary TQPT in a TR-invariant Weyl CDW.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PASSAT: particle accelerator helioScopes for Slim Axion-like-particle deTection

We propose a novel method to search for axion-like particles (ALPs) at particle accelerator experiments. ALPs produced at the target via the Primakoff effect subsequently enter a region with a magnetic field, where they are converted to photons that are then detected. Dubbed Particle Accelerator helioScopes for Slim Axion-like-particle deTection (PASSAT), our proposal uses the principle of the axion helioscope but replaces ALPs produced in the Sun with those produced in a target material. Since we rely on ALP-photon conversions , our proposal probes light (slim) ALPs that are otherwise inaccessible to laboratory-based experiments which rely on ALP decay, and complements astrophysical probes that are more model-dependent. As a first application, we reinterpret existing data from the NOMAD experiment in light of PASSAT, and constrain the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 10^{-4}~\mathrm{GeV}^{-1}$$ ~ 10 - 4 GeV - 1 . As benchmarks of feasible low-cost experiments improving over the NOMAD limits, we study the possibility of re-using the magnets of the CAST and the proposed BabyIAXO experiments and placing them at the proposed BDF facility at CERN, together with some new detectors. We find that these realizations of PASSAT allow for a direct probe of the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 4\times 10^{-6}~\mathrm{GeV}^{-1}$$ ~ 4 × 10 - 6 GeV - 1 , which are regions that have not been probed yet by experiments with laboratory-produced ALPs. In contrast to other proposals aiming at detecting single or two-photon only events in hadronic beam dump environments, that rely heavily on Monte Carlo simulations, the background in our proposal can be directly measured in-situ , its suppression optimized, and the irreducible background statistically subtracted. Sensitivity evaluations with other beams will be the subject of a future paper. The measurements suggested in this paper represent an additional physics case for the BDF at CERN beyond those already proposed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SMART U(1)$$_X$$: standard model with axion, right handed neutrinos, two Higgs doublets and U(1)$$_X$$ gauge symmetry

Abstract To address five fundamental shortcomings of the Standard Model (SM) of particle physics and cosmology, we propose a phenomenologically viable framework based on a $$U(1)_X \times U(1)_{PQ}$$ U ( 1 ) X × U ( 1 ) PQ extension of the SM, that we call “SMART U(1) $$_X$$ X ”. The $$U(1)_X$$ U ( 1 ) X gauge symmetry is a well-known generalization of the $$U(1)_{B-L}$$ U ( 1 ) B - L symmetry and $$U(1)_{PQ}$$ U ( 1 ) PQ is the global Peccei–Quinn (PQ) symmetry. Three right handed neutrinos are added to cancel $$U(1)_X$$ U ( 1 ) X related anomalies, and they play a crucial role in understanding the observed neutrino oscillations and explaining the observed baryon asymmetry in the universe via leptogenesis. Implementation of PQ symmetry helps resolve the strong CP problem and also provides axion as a compelling dark matter (DM) candidate. The $$U(1)_X$$ U ( 1 ) X gauge symmetry enables us to implement the inflection-point inflation scenario with $$H_{inf} \lesssim 2 \times 10^{7}$$ H inf ≲ 2 × 10 7 GeV, where $$H_{inf}$$ H inf is the value of Hubble parameter during inflation. This is crucial to overcome a potential axion domain wall problem as well as the axion isocurvature problem. The SMART U(1) $$_X$$ X framework can be successfully implemented in the presence of SU (5) grand unification, as we briefly show.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum system engineering for a next-generation search for axion dark matter. Final report

This project pursued two major experimental goals related to the quantum engineering of the ensemble of nuclear spin qubits, as a potential sensing platform for axion-like dark matter: (1) control the fidelity of spin ensemble state preparation, (2) characterize the coherence time of the spin ensemble under different drive conditions. We have successfully achieved these goals. We have experimentally demonstrated control over the polarization of the 207 Pb nuclear spin ensemble, using light-induced transient paramagnetic centers. We have also performed NMR measurements on the 207 Pb spin ensemble in solid ferroelectric PMN-PT, demonstrating the T 2 coherence time of 16.7 ms. We have used this approach to set new experimental limits on the EDM and the gradient interactions of axion-like dark matter in the mass range 162 neV to 166 neV. In addition, having characterized the magnetic resonance properties of the 207 Pb spin ensemble in solid ferroelectric PMN-PT, we have formulated the technical requirements needed to reach the quantum sensitivity limits in a magnetic resonance-based search for axion-like dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calculations for cosmic axion detection

Calculations are presented, using properly nomalized couplings and masses for Dine-Fischler-Srednicki axions, of power rates and signal temperatures for axion-photon conversion in microwave cavities. The importance of the galactic-halo axion line shape is emphasized. Spin-coupled detection as an alternative to magnetic-field-coupled detection is mentioned.

Krauss, L.↗

Laser-induced axion photoproduction

Axion photoproduction is suggested as a systematic technique for investigating the coupling of new elementary pseudoscalar or scalar particles in the megaelectronvolt mass range to leptons, photons, and hadronic matter. The experiments involve a configuration where a low-energy photon collides with a relativistic electron beam. Threshold production energies of 300 GeV can be accomplished with an optical laser, and those of 14.5-50 GeV can be achieved with wigglers directed onto an electron beam. With this scheme, at least 10 to the -7th of the electrons can be converted to axions, providing a 1-100 thousand/s relativistic beam of axions.

Brodsky, S. J.↗

Simulation of Axion-like Particles at DarkQuest

DarkQuest is a collaboration at Fermilab searching for beyond the StandardModel (SM) physics using a xed target beam dump experiment. This experiment featuresa proton beam colliding with a target and creating particles, possibly theoretical ones,from the interactions that occur. A popular theoretical particle is the axion, an elementaryparticle that explains the breakage of symmetry that occurs in our current model of physics,called the strong CP problem. An axion-like particle (ALP) is similar to an axion in itsresolution of the strong CP problem, but has mass, and so is detectable by experimentation.By simulating the production and decay of an ALP, we can estimate the region of parameterspace of ALP mass and SM coupling that DarkQuest could make a discovery.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THERMAL/STRUCTURAL ANALYSIS OF THE AXION QUANTUM METROLOGY CAVITY AND ITS COMPONENTS

This research was centered around maximizing the capability to cool dielectric material within a containment unit, or Photonic Band Gap (PBG) cavity, designed for detecting axion dark matter and identifying the unit’s thermal properties. There are multiple types of PBG cavities, but the latest version that axion researchers wish to use has been theorized to contain possible issues related to its thermal properties. Thermal conductivity is an issue with the dielectric material because it is made from alumina which is highly insulative. This is important since the research is being done in a cryogenic environment and the thermal noise affects the quantum bit used for detecting the axion to photon conversion process. Therefore, any improvements to this unit should be justified and implemented but are not entirely limited to thermal contact related aspects of PBG cavities. A prospect of using sapphire in place of alumina also exists, but this is a more expensive, less tested, and more elusive material to justify the creation of a full dielectric structure out of sapphire. Thermal aspects of the cavity were analyzed using finite element method (FEM) and an experiment designed to test different thermal joint materials. FEM was used to check the contraction of the cavity during cooling, the contact quality between the dielectric material and cavity wall, theheat flow rate through the assembly, and helps visualize the cavity’s reaction to different design changes. A simple comparison between thermal conductivity curves justified the usage of sapphire over alumina from a thermal property point of view. Thus, the method of experimentation had an additional dielectric material, sapphire, to test with and compare to alumina. The thermal test identified which material is best to use for a thermal joint but also simultaneously found the conductance of the joint and dielectric material as well as an estimate for what the temperature is inside the larger scale cavity since a thermometer cannot be placed inside the PBG when it cools. Initially, the cavity simulation was tested for structural deformation properties and stress distribution since it is made of copper which contracts heavily in comparison to most other materials. The reduction in volume of the cavity was less than anticipated which gave more room for a possible usage of a modified thermal joint for additional contact area and higher conductivity.

43 PARTICLE ACCELERATORS↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beehive haloscope for high-mass axion dark matter

We propose a new haloscope geometry that can arbitrarily increase the resonator volume for a given target axion mass. This geometry consists of closely packed, overlapping coaxial cavities operating as a single resonator. While the resonant frequency is still determined by the dimensions of the individual “cells,” the strong interactions between the cells encourage the entire “beehive” to oscillate in phase, a phenomenon expected of tightly coupled harmonic oscillators. This synchronization behavior allows the construction of a singly connected large volume resonator at high frequency by simply increasing the number of the cells. Using direct numerical simulations, we verify the existence of a global eigenmode that has a high (40%) form factor in a 169-element beehive resonator. The resonant frequency of the eigenmode is tunable by moving the center rods laterally in unison. The form factor is very tolerant to dimensional deviations and misalignment as a result of mode hybridization due to strong coupling. The beehive haloscope inherits many appealing properties from the conventional coaxial cavity: a high quality factor, compatibility with a solenoid magnet, and ease of fabrication, tuning, and coupling. We argue that this geometry is an excellent candidate for high-mass axion searches covering the post-inflationary parameter space (>5 GHz).

47 OTHER INSTRUMENTATION↗

Exploration of Wire Array Metamaterials for the Plasma Axion Haloscope

A plasma haloscope has recently been proposed as a feasible approach to extend the search for dark matter axions above 10 GHz (≈40 μeV), whereby the microwave cavity in a conventional axion haloscope is supplanted by a wire array metamaterial. Since the plasma frequency of a metamaterial is determined by its unit cell, and is thus a bulk property, a metamaterial resonator of any frequency can be made arbitrarily large, in contrast to a microwave cavity which incurs a steep penalty in volume with increasing frequency. To assess the actual potential of this concept as a practical dark matter haloscope, the basic properties of wire array metamaterials have been investigated through an extensive series of S 21 measurements in the 10 GHz range. This report presents some new systematics of wire array metamaterials themselves including the approach to full plasmonic behavior, the applicability of the semianalytic theory of Belov, and estimates of the loss term which bode favorably for the plasmonic haloscope application. This present work constitutes the first precision test of the semianalytic theory of Belov et al., for which the predicted plasma frequency agrees with the experimental value at the 0.1% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy conservation and axion back-reaction in a magnetic field

Axion clumps in an external magnetic field can emit electromagnetic radiation which causes them to decay. In the presence of a plasma, such radiation can become resonant if the clump frequency matches the plasma frequency. Typically, the decay or back-reaction of the clump is ignored in the literature when analyzing such radiation. In this paper we present a self consistent, semi-analytic approach which captures axion backreaction using energy conservation. We find that inclusion of back-reaction changes the clump frequency over time enabling clumps with a range of different initial frequencies to become resonant at some point in their time evolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗