Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller tuning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A safe reinforcement learning algorithm for supervisory control of power plants

Traditional control theory-based methods require tailored engineering for each system and constant fine-tuning. In power plant control, one often needs to obtain a precise representation of the system dynamics and carefully design the control scheme accordingly. Model-free Reinforcement learning (RL) has emerged as a promising solution for control tasks due to its ability to learn from trial-and-error interactions with the environment. It eliminates the need for explicitly modeling the environment’s dynamics, which is potentially inaccurate. However, the direct imposition of state constraints in power plant control raises challenges for standard RL methods. To address this, we propose a chance-constrained RL algorithm based on Proximal Policy Optimization for supervisory control. Our method employs Lagrangian relaxation to convert the constrained optimization problem into an unconstrained objective, where trainable Lagrange multipliers enforce the state constraints. In conclusion, our approach achieves the smallest distance of violation and violation rate in a load-follow maneuver for an advanced Nuclear Power Plant design.

constrained optimization↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control of Surface Chemical Reactions through Solid Stiffness

Control of surface reactions is commonly achieved by modification of surface electronic structures. Here, we discover an alternative pathway for controlling surface reactions by tuning the mechanical stiffness of the underlying material. We find that in addition to the typically assumed surface electronic contribution right at the reactive site, the contribution from the deformation of the bulk region plays a vital role in controlling surface reactions. The underlying mechanism is an elastic relaxation of the solid, which depends on the material’s stiffness and can be modified by tuning bulk stoichiometry. The effect of bulk stiffness on surface reactions has been demonstrated by considering hydrogen scission reaction and oxygen incorporation reaction during corrosion of amorphous SiC in water and air, respectively. Finally, our results imply that tuning of bulk stiffness by modifying stoichiometry can provide an effective method for controlling surface reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control of Output Power in Primary Side LCC and Secondary Series Tuned Wireless Power Transfer System without Secondary Side Sensors

The output power of a wireless power transfer (WPT) system varies with load and coupling factor of the inductively coupled coils. This paper presents a method to control the output power of primary side LCC and secondary side series tuned WPT system using information of primary side variables. In this approach, a secondary side control system or secondary side sensors are not needed. Detailed mathematical derivations are given to identify and justify the suitable primary side variable that accomplishes the desired purpose without the need of any secondary side communications. Simulation results presented validate the proposed scheme.

Mukherjee, Subho↗

An Update to the National Renewable Energy Laboratory Baseline Wind Turbine Controller

The National Renewable Energy Laboratory's 5-MW wind turbine model is well established as an industry standard and is often used as a comparison model, or a model on which to build upon. Though effective, the legacy controller for the 5-MW wind turbine uses a simple algorithm that is not up to date with many industry standards. Additionally, as the research community has advanced into fast-paced development cycles, as systems engineering tools such as Wind-Plant Integrated System Design & Engineering Model (WISDEM ®) [1] are employed, and as a greater focus on controls co-design practices is encouraged, demand for a generic wind turbine controller has arisen. This work presents updates for the NREL 5-MW controller to a more modern control architecture, and establishes a generic tuning framework that can be easily adapted to various wind turbines. Based on initial results, the updated generic controller eases the automatic tuning process while maintaining or improving the performance of the legacy NREL 5-MW controller.

17 WIND ENERGY↗

An Update to the NREL Baseline Wind Turbine Controller: Preprint

The NREL 5MW wind turbine model is well established as an industry standard and is often used as a comparison model, or a model on which to build upon. Though effective, the legacy controller for the NREL 5MW wind turbine is built on a simple algorithm that is not up to date with many industry standards. Additionally, as the research community has advanced into more fast-paced development cycles, as systems engineering tools such as WISDEM \cite{WISDEM} are employed, and as a greater focus on controls co-design practices is encouraged, a demand for a generic wind turbine controller has arisen. This work presents updates for the NREL 5MW baseline controller to a more modern control architecture, and establishes a generic tuning framework that can be easily adapted to various wind turbines. Based on initial results, the updated generic controller eases the automatic tuning process, while maintaining or improving upon the performance of the legacy NREL 5MW controller.

17 WIND ENERGY↗

Electronic and Electrochemical Control of Isostructural Ruthenium Hydricities and the Implications for Catalytic Overpotentials

Electronic tuning of metal hydrides enables precise control over potentials, mechanisms, selectivity, and rates of electrocatalytic reactions by regulating bond dissociation free energies such as the hydricity (Δ$G$ H- ° ) and $pK$ a of the catalyst. Here, we investigate a series of electronically tuned ruthenium hydrido complexes that are isostructural at the metal center: [Ru(4,4'-R 2 -bpy) 2 (CO)H] + (R = CF 3 , Cl, H, CH 3 , and CH 3 O; bpy = 2,2'-bipyridine) (denoted as (R)Ru-H+). A substantial 22 kcal mol -1 hydricity range is available across five complexes in three stable oxidation states: (R)Ru-H + , (R)Ru-H 0 , and (R)Ru-H - . Thermodynamic and mechanistic predictions of electrocatalytic proton reduction were tested experimentally by reducing protons from weak acids to H 2 . Two mechanisms are observed, depending on the acid strength and the catalyst hydricity. The rate constants for hydride transfer and protonation of the catalyst were, in some cases, extracted from the analysis of cyclic voltammetry data. A key finding is a 400 mV decrease in the catalytic overpotential for H 2 production by using a doubly reduced electron-poor metal hydride instead of a singly reduced electron-rich metal hydride. In conclusion, the former also exhibits a higher rate constant for hydride transfer, representing a strategy to disconnect rate and free energy relationships.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging peptide–cellulose interactions to tailor the hierarchy and mechanics of peptide–polymer hybrids

Inspired by spider silk's hierarchical diversity, we leveraged peptide motifs with the capability to tune structural arrangement for controlling the mechanical properties of a conventional polymer framework. The addition of nanofiller with hydrogen bonding sites was used as another pathway towards hierarchical tuning via matrix–filler interactions. Specifically, peptide–polyurea hybrids (PPUs) were combined with cellulose nanocrystals (CNCs) to develop mechanically-tunable nanocomposites via tailored matrix–filler interactions (or peptide–cellulose interactions). In this material platform, we explored the effect of these matrix–filler interactions on the secondary structure, hierarchical ordering, and mechanical properties of the peptide hybrid nanocomposites. Interactions between the peptide matrix and CNCs occur in all of the PPU/CNC nanocomposites, preventing α-helical ordering, but promoting inter-molecular hydrogen bonded β-sheet formation. Depending on peptide and CNC content, the Young's modulus varies from 10 to 150 MPa. Unlike conventional cellulose-reinforced polymer nanocomposites, the mechanical properties of these composite materials are dictated by a balance of CNC reinforcement, peptidic ordering, and microphase-separated morphology. This research highlights that leveraging peptide–cellulose interactions is a strategy to create materials with targeted mechanical properties for a specific application using a limited selection of building blocks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive PID Gain Scheduling Control for Hydropower Turbine Using Neural CDE and Stochastic Distribution Shaping

This paper introduces a gain-scheduling PID controller design strategy for hydroturbine frequency control mode. This scheme first uses real data to learn the nonlinear dynamics of the hydroturbine using neural controlled differential equations and then perturbs the obtained nonlinear system at different equilibrium points, based on which a static output feedback adaptive dynamic programming algorithm is then used to optimize the PID gains for each equilibrium point. Moreover, a continuous-time version of stochastic distribution control is proposed to further fine-tune the optimized PID gains. Finally, the controller is obtained by implementing linear interpolation between the optimized PID control gains. The simulation results show that the proposed gain-scheduling PID controller can control a larger range of operation points compared with the given fixed PID controller and the baseline method. Compared with the given fixed PID controller, the proposed gain-scheduling PID controller can regulate hydroturbine frequency against disturbances induced by power-load variation with over 50% less overshoot for some operation points.

13 HYDRO ENERGY↗

Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems [SWR-22-50]

Gradient-based controllers have parameters called step sizes that determine how sensitive its control actions are to received inputs. Finding a practical setting for a step size is important. If it is too small, the controller is ineffective by not reacting in a significant manor to its received inputs. On the other hand, if it is too large, the actions implemented by the controller may be excessive and cause the controlled system to become unstable. The main objective of the Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems is to speed up the implementation of gradient-based control schemes by automatically tuning its step sizes instead of having a practitioner spend considerable time doing the task manually. Only simple adjustments need to be made to the code of each controller with a step size to allow the addition of an individual automatic tuner. This can be applied to any RT-OPF based control for DER management.

Comden, Joshua↗

Precision Structure Engineering of High-Entropy Oxides under Ambient Conditions

High-entropy oxides (HEOs) have unveiled a unique frontier in the realm of heterogeneous catalysis, taking advantage of the entropic effect and increased complexities to deliver ultrahigh stability and large tuning capability. However, current HEO synthesis mainly relies on high-temperature annealing approaches affording HEOs possessing no or low surface area, inferior active site exposure efficiency, and low controllability over the structure tuning. The grand challenge lies in producing high-quality HEO catalysts with high active site utilization efficiency, which relies on precision structure engineering, preferably under mild conditions. In this work, an in situ lattice engineering approach was developed to afford a supported HEO catalyst under ambient conditions. The HEO compositions (CuCoFeNiMnO x ) were uniformly integrated into the lattice of CeO 2 driven by cavitation-induced nucleation being generated via ultrasonication. The as-afforded catalysts were featured by high surface area, atomically dispersed HEO compositions, active redox properties, abundant oxygen vacancies (O V ), antiagglomeration, and high phase stability under harsh conditions. Compared with the ex situ introduction of HEO on the surface, the in situ method provides dual benefits to maintain the dispersity of HEO via entropic and lattice confinement effects. Engineering the complex HEO within the lattice of fluorite-structured CeO 2 also yields abundant defects (e.g., O V ) and active metal sites with strong reducing properties (e.g., Ce 3+ and Cu + ), which greatly improves the activity of the lattice oxygen and tunability of the adsorption behavior of the guest molecules, especially in the presence of impurities (e.g., water and propane). The catalytic performance of the supported HEO catalyst in oxidative procedures surpasses the pure dense phase HEO as well as the ex situ-generated catalysts. Further, the synthesis approach being developed in this work, together with the fundamental understanding in structure evolution and reaction mechanism, showcases a facile pathway under ambient conditions to generate stable catalysts capable of maintaining structural robustness in high-temperature conditions while delivering enhanced catalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sliding Mode Network Perimeter Control

Urban traffic congestion is a chronic problem faced by many cities in the US and worldwide. It results in inefficient infrastructure use as well as increased vehicle fuel consumption and emission levels. Congestion is intertwined with delay, as road users waste precious hours on the road, which in turn reduces productivity. Researchers have developed, and continue to design, tools and systems to alleviate this problem. Network perimeter control is one such tool that has been studied extensively. It attempts to control the flow of vehicles entering a protected area to ensure that the congested regime predetermined by the Network Fundamental Diagram (NFD) is not reached. In this paper, a method derived from sliding mode control theory is presented. Its main advantages over proportional-integral controllers include (1) minimal tuning, (2) no linearization of the governing equations, (3) no assumptions with regard to the shape of the NFD, and (4) ability to handle various demand profiles without the need to retune the controller. A sliding mode controller was implemented and tested on a congested grid network. The results show that the proposed controller produces network-wide delay savings and disperses congestion effectively.

42 ENGINEERING↗

A simulation‐based integrated virtual testbed for dynamic optimization in smart manufacturing systems

Abstract In a manufacturing system, production control‐related decision‐making activities occur at different levels. At the process level, one of the main control activities is to tune the parameters of individual manufacturing equipment. At the system level, the main activity is to coordinate production resources and to route parts to appropriate workstations based on their processing requirement, priority indices, and control policy. At the factory level, the goal is to plan and schedule the processing of parts at different operations for the entire system in order to optimize certain objectives. Note that the results of such activities at different levels are closely coupled and affect the overall performance of the manufacturing system as a whole. Therefore, it is important to systematically integrate these control and optimization activities into one unified platform to ensure the goal of each individual activity is aligned with the overall performance of the system. In this paper, we develop a simulation‐based virtual testbed that implements dynamic optimization, automatic information exchange, and decision‐making from the process‐level, system‐level, and factory‐level of a manufacturing system into an integrated computation environment. This is demonstrated by connecting a Python‐based numerical computation program, discrete‐event simulation software (Simul8), and an optimization solver (CPLEX) via a third‐party master program. The application of this simulation‐based virtual testbed is illustrated by a case study in a machining shop.

Sun, Yuting↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Dynamic, resilient virtual sensing system and shadow controller for cyber-attack neutralization

An industrial asset may have monitoring nodes (e.g., sensor or actuator nodes) that generate current monitoring node values. An abnormality detection and localization computer may receive the series of current monitoring node values and output an indication of at least one abnormal monitoring node that is currently being attacked or experiencing a fault. An actor-critic platform may tune a dynamic, resilient state estimator for a sensor node and output tuning parameters for a controller that improve operation of the industrial asset during the current attack or fault. The actor-critic platform may include, for example, a dynamic, resilient state estimator, an actor model, and a critic model. According to some embodiments, a value function of the critic model is updated for each action of the actor model and each action of the actor model is evaluated by the critic model to update a policy of the actor-critic platform.

Roychowdhury, Subhrajit↗