Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling

Standard penetrator sampling systems were designed in order to allow for sampling via penetrators to produce a full set of sample acquisitions including volatile liquids, fine powders, and solid fragments. A gravity harpoon sampler has been designed with a removable tip and a quick coupling. The separation allows for sample handling and eliminates sample cross-contamination. Also, this design allows for multiple use of the penetrator body, which is the largest and heaviest part of the penetrator, while allowing for multiple changes of the light-mass, penetrator tip to avoid sample cross-contamination. The penetrator tip design has been improved by adding a spring trap to retain the sample, as well as a means for connecting to a quick coupling. Quick connect tips have been demonstrated in a sample handling carousel. The penetrator was released and rewound and the tips were released into a circular platter for rotation into instrument stations. The pyro-harpoon sampler was fabricated and tested with a NASA Standard Initiator (NSI) pyrotechnic charge. Initial tests collected cryogenic ice, but removal of the small pyro-harpoon from the ice was difficult. A brass metal sheath was then fitted over the harpoon tip, and removal from the ice was greatly alleviated by leaving the sheath in the ice. Quartz windows in the tips allow direct optical and spectral imaging and gas chromatography-mass spectrometer (GCMS) pyrolysis, and were found to survive impact. All systems were successfully tested by dropping into sand and into cryogenic ice.

Sherritt, Stewart↗

Review on drop towers and long drop tubes

A drop tube is an enclosure in which a molten sample can be solidified while falling; three such large tubes are currently in existence, all at NASA research facilities, and are engaged in combustion and fluid physics-related experiments rather than in materials research. JPL possesses smaller tubes, one of which can be cryogenically cooled to produce glass and metal microshells. A new small drop tube will soon begin operating at NASA Lewis that is equipped with four high-speed two-color pyrometers spaced equidistantly along the column.

Bayuzick, R. J.↗

An Improved Formulation for Calorimetric Emittance Testing of Spacecraft Thermal Control Coatings

Spacecraft often really heavily on passive thermal control to maintain operating temperature. An important parameter in the spacecraft heat balance equation is the emittance of thermal control coatings as a function of coating temperature. One method for determining the emittance of spacecraft thermal control from elevated temperature to cryogenic temperatures relies on a calorimetric technique. The fundamental equation governing this test method can be found in numerous places in the literature and although it generally provides reasonable results, its formulation is based on a conceptual flaw that only becomes apparent when the sample temperature approaches the wall temperature during testing. This paper investigates the cause for this error and develops the correct formulation for calorimetric emittance testing. Experimental data will also be presented that illustrates the difference between the two formulations and the resulting difference in the calculated emittance.

Kauder, Lonny R.↗

A proposed configuration for a stepped specimen to be used in the systematic evaluation of factors influencing warpage in metallic alloys being used for cryogenic wind tunnel models

A proposed configuration for a stepped specimen to be used in the system evaluation of mechanisms that can introduce warpage or dimensional changes in metallic alloys used for cryogenic wind tunnel models is described. Considerations for selecting a standard specimen are presented along with results obtained from an investigation carried out for VASCOMAX 200 maraging steel. Details of the machining and measurement techniques utilized in the investigation are presented. Initial results from the sample of VASCOMAX 200 show that the configuration and measuring techniques are capable of giving quantitative results.

Wigley, D. A.↗

NASA Tech Briefs, November 2011

The topics include: 1) Flight Test Results from the Rake Airflow Gage Experiment on the F-15B; 2) Telemetry and Science Data Software System; 3) CropEx Web-Based Agricultural Monitoring and Decision Support; 4) High-Performance Data Analysis Tools for Sun-Earth Connection Missions; 5) Experiment in Onboard Synthetic Aperture Radar Data Processing; 6) Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System; 7) Improved Design and Fabrication of Hydrated-Salt Pills; 8) Monolithic Flexure Pre-Stressed Ultrasonic Horns; 9) Cryogenic Quenching Process for Electronic Part Screening; 10) Broadband Via-Less Microwave Crossover Using Microstrip-CPW Transitions; 11) Wheel-Based Ice Sensors for Road Vehicles; 12) G-DYN Multibody Dynamics Engine; 13) Multibody Simulation Software Testbed for Small-Body Exploration and Sampling; 14) Propulsive Reaction Control System Model; 15) Licklider Transmission Protocol Implementation; 16) Core Recursive Hierarchical Image Segmentation; 17) Two-Stage Centrifugal Fan; 18) Combined Structural and Trajectory Control of Variable-Geometry Planetary Entry Systems; 19) Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options; 20) Temperature-Sensitive Coating Sensor Based on Hematite; 21) Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis; 22) Detection of Carbon Monoxide Using Polymer-Carbon Composite Films; 23) Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors; 24) Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer; 25) Integrated Lens Antennas for Multi-Pixel Receivers; 26) 180-GHz Interferometric Imager; 27) Maturation of Structural Health Management Systems for Solid Rocket Motors; 28) Validating Phasing and Geometry of Large Focal Plane Arrays; 29) Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration; 30) Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments; 31) Solid-State Spectral Light Source System; 32) Multiple-Event, Single-Photon Counting Imaging Sensor; 33) Surface Modeling to Support Small-Body Spacecraft Exploration and Proximity Operations; and 34) Achieving Exact and Constant Turnaround Ratio in a DDS-Based Coherent Transponder.

Source record↗

Development and Testing of Femtosecond Laser Surface Processing (FLSP) Treated Guide Vanes for Application to Advanced Cryogenic Liquid Acquisition Devices

Liquid Acquisition Devices (LADs) are used inside propellant tanks in microgravity to collect liquid propellant to move towards the sump or outlet of a tank during expulsion or transfer. In microgravity, vehicle thrusters can produce necessary phase separation, but in the absence of thrust, surface tension is the driver of fluid behavior. Liquid in microgravity will tend to form a sphere to minimize surface area. If a LAD can be made more “attractive” to a propellant (omniphilic), then it should perform its function more effectively. This paper presents preliminary results on using femtosecond laser surface processing (FLSP) to change the wetting properties of a vane LAD. FLSP can make metals superhydrophilic or omniphilic; by controlling the applied laser parameters, the resulting micro and nanoscale surface features can be tailored to control and optimize hydrophilic/omniphilic properties. Two LAD galleries with guide vanes were recently fabricated, a control sample and an FLSP-treated sample. The LADs were ground tested and also implemented in a parabolic flight experiment. Based on contact angle and roll-off angle measurements of the surface-treated vane, FLSP appears to be a promising technique to improve efficiency of LADs

Liquid Acquisition Devices↗

Temperature Evolution in Excitonic Absorptions of Cd(0.96)Zn(0.04) Materials

We report cryogenic optical properties of Cd(0.96)Zn(0.04)Te wafers that are used as substrate seed layers in HgCdTe focal-plane array detectors. These studies are motivated by the fact that the substrate optical properties influence the overall detector performance. The studies consist of measuring the sample frequency dependent transmittance (T) and reflectance (R) above and below the optical band-gap in the UV/Visible and infrared frequency ranges, and with temperature variation of the sample from 5 to 300 K. These measurements show that the optical gap near 1.49 eV at 300 K increases to 1.62 eV at 5 K. Finally, we observe sharp absorption peaks near this gap energy at low temperatures. The close proximity of these peaks to the optical transition threshold suggests that they originate from the creation of bound electron-hole pairs or excitons. The decay of these excitonic absorptions may contribute to a photoluminescence and transient background response of these back-illuminated HgCdTe CCD detectors.

Quijada, Manuel A.↗

In situ measurement of water vapor in the stratosphere with a cryogenically cooled Lyman-alpha hygrometer

In situ measurements of water vapor in the stratosphere with a new instrument are reported. The instrument has been designed to observe daytime water vapor from a multiinstrument balloon gondola that simultaneously measures free radicals such as OH, HO2, and O3 in the stratosphere up to 40 km. Lyman-alpha photofragment fluorescence is used to measure water molecules in a flowing sample of ambient air. A brief description of the instrument is given, followed by the results of the first four balloon flights. The measured mixing ratio for this flight varies from 3.0-5.5 ppmv over the altitude range of 17-34 km. Adjustments in the cooling protocol for the flights of July 6, 1988, July 28, and August 25, 1989, result in a much higher signal-to-noise ratio. Profiles from these three flights are similar to, but somewhat higher, than the 1987 profile. Implications of measurements are discussed, as are the issues of short- and long-term variability of stratospheric water vapor.

Schwab, J. J.↗

Use of Capillaries for Macromolecular Crystallization in a Cryogenic Dewar

The Enhanced Gaseous Nitrogen (EGN) Dewar is a cryogenic dry shipper with a sealed cylinder inserted inside along with a temperature-monitoring device, and is intended for macromolecular crystallization experiments on the International Space Station. Within the Dewar, each crystallization experiment is contained as a solution within a plastic capillary. The standard procedure for loading samples in these tubes has involved rapid freezing of the precipitant and biomolecule solution directly in liquid nitrogen; this method, however, often results in uncontrolled formation of air voids. These air pockets, or bubbles, then can lead to irreproducible crystallization results. A novel protocol has been developed to prevent formation of bubbles, and this has been tested in the laboratory as well as aboard the International Space Station during a 42-day long mission of July/August of 2001. Furthermore, gain or loss of mass from solutions within the capillaries revealed that mass transport amongst separated tubes occurred, and that this mass transport was determined by the hygroscopic character of a solution contained in any given tube. The sample volume and the surface area of the plastic capillary tube also related to the observed mass transport.

Ciszak, Ewa↗

Use of Capillaries for Macromolecular Crystallization in a Cryogenic Dewar

The enhanced gaseous nitrogen (EGN) dewar is a cryogenic dry shipper with a sealed cylinder inserted inside along with a temperature monitoring device, and is intended for macromolecular crystallization experiments on the International Space Station. Within the dewar, each crystallization experiment is contained as a solution within a plastic capillary tube. The standard procedure for loading samples in these tubes has involved rapid freezing of the precipitant and biomolecular solution, e.g., protein, directly in liquid nitrogen; this method, however, often resulted in uncontrolled formation of air voids, These air pockets, or bubbles, can lead to irreproducible crystallization results. A novel protocol has been developed to prevent formation of bubbles, and this has been tested in the laboratory as well as aboard the International Space Station during a 42-day long mission of July/August 2001. The gain or loss of mass from solutions within the plastic capillaries revealed that mass transport occurred among separated tubes, and that this mass transport was dependent upon the hygroscopic character of the solution contained in any given tube. The surface area of the plastic capillary tube also related to the observed mass transport. Furthermore, the decreased mass of solutions of-protein correlated to observed formation of protein crystals.

Ciszak, Ewa↗

Solar White Thermal Coating for Cryogenic Propulsion Systems

NASA is currently conducting research into the potential of storing cryogenic fluid in low Earth orbit (LEO). Having cryogenic propellant readily available for high-performance propulsion systems can be very beneficial for deep space missions in the near future. One of the key challenges to storing cryogenic fluid in LEO is minimizing boil-off. To address the challenge, NASA is evaluating new concepts in thermal insulation. One recent experimental study evaluated the feasibility of using Yttrium Oxide (Y2O3), formed into tiles or spray coating that can potentially be used as a thermal coating for cryogenic propellant storage applications in deep space. Due to its temperature and wavelength dependent optical properties, this “solar white” material can reflect a vast majority of the Sun’s radiative energy while having a very high infrared emissivity for rejecting heat to deep space. As a part of the material development and proof of concept testing, multiple tests have been run at KSC and GRC to demonstrate the performance of the material. At GRC, the tests were run using the Deep Space Solar Simulator (DS3) which contains a thermal vacuum chamber in which the solar white sample was exposed to a deep space environment (< 10 K, optically dense walls) while under full illumination via solar lamp. In order to improve the use of the test results and apply them to spacecraft, there is a need to be able to model the material properties within NASA’s standard thermal modeling tools. As such, it was set out to verify a thermal model of one of the experiments using Thermal Desktop with Sinda. The thermal model of the DS3 test setup includes the solar white sample along with a solar lamp simulator capable of outputting heat at varying wavelengths. The model was developed in order to validate the test results and also to help predict results that will be obtained in future tests. This paper will review the modeling methods and thermal analysis results for various test cases that were run within the DS3 facility.

Cryogenic↗

Image Simulator for the Wide-Field Infrared Explorer

The Wide-Field Infrared Explorer (WIRE) is a cryogenically-cooled spaceborne telescope designed to study the evolution of starburst galaxies...We describe the design and implementation of the simulator, with particular emphasis on the generation of point-spread functions. The simulator is written in C for use on Unix workstations, and we assess its performance. Sample raw and combined images are displayed, and the image processing steps are outlined. The uses of the simulator to verify that mission requirements are met, to optimize observing strategy, and to test data analysis techniques are also described.

infrared↗

Calculation of sidewall boundary-layer parameters from rake measurements for the Langley 0.3-meter transonic cryogenic tunnel

Correction of airfoil data for sidewall boundary-layer effects requires a knowledge of the boundary-layer displacement thickness and the shape factor with the tunnel empty. To facilitate calculation of these quantities under various test conditions for the Langley 0.3 m Transonic Cryogenic Tunnel, a computer program was written. This program reads the various tunnel parameters and the boundary-layer rake total head pressure measurements directly from the Engineering Unit tapes to calculate the required sidewall boundary-layer parameters. Details of the method along with the results for a sample case are presented.

Murthy, A. V.↗

Metallic Environmentally Resistant Coating Rapid Innovation Initiative

Lightweight alloys such as aluminum (Al) and titanium (Ti) are often specified for space systems to minimize mass while maintaining structural integrity [1,2]. Such alloys however, have poor tribological response (high friction and wear), especially in extreme space environments, which becomes worse with the additional presence of lunar regolith. This leads to short lifetimes and premature failures that will ultimately limit long term operations on the lunar surface [2]. This project is addressing this technology gap by developing advanced wear- and radiation-resistant coatings for lightweight parts to extend the life-time and sustainability of both lunar and Martian assets. Ceramics were considered for their high wear resistance, but were rejected because of their low fracture toughness, which would be especially problematic for structural components. The novel and existing coating technologies and deposition methods are being tested in this project. The coating materials are Boron Nitride-Aluminum (BN-Al), Nickle Titanium (NiTi), Aluminum Oxide (AlO3), Ti64 with hBN at 2 and 10 vol percent (Ti-2vol%hBN and Ti-10vol%hBN), and the deposition techniques are high pressure cold-spray (CS) and ambient and vacuum plasma-spray (APS and VPS) [3,4,5]. BN-Al, NiTi, Ti-2vol%hBN, and Ti-10vol%hBN were applied with all three deposition techniques, and AlO3 was applied only using the APS deposition technique. A tungstenite (WS2) film was applied to the NiTi VPS coating. The coating and deposition technique configurations are being tested against several key end-use performance parameters. The parameters include the capabilities of the coatings under wear environments such as regolith simulant, thermal cycling from high (120°C) to cryogenic (-173°C), high vacuum (~10-7 torr), and pre- and post-exposure to ionizing particle radiation. Wear tests include pin on disk, three-body abrasion, and surface erosion by high velocity regolith impacts. The initial down selection is being performed using on virgin and environmental exposure samples using pin on disk and three body abrasion wear tests. From preliminary assessment of this testing, a few configurations were eliminated. Ti-10vol%hBN could not be applied using CS application and NiTi could not be applied using APS or CS application so these configurations did not get tested. Early pin on disk wear tests showed poor wear performance of BN-Al so this coating was eliminated early in the testing process. AlO3 on Al substrate did not survive thermal cycling, but wear testing is continuing for AlO3 on Ti substrate. A more detailed analysis is being con-ducted to further reduce the number of configuration for phase II and III. Phase II testing will include conventionally and additively manufactured substrates with surface erosion testing. In phase III, the coatings will be applied to three mechanism types: channel and slot, ball and socket, and a hinge joint. Each will demonstrate a different type of wear incidence. The mechanisms and their base materials are of direct interest to the end users and infusion points: the Human Landing System (HLS) and the Lunar Surface Innovation Initiative (sustained lunar surface operations). The technology development project is based out of Marshall Space Flight Center, has partnered with Florida International University (Miami, FL) and Plasma Processes (Huntsville, Al), and is supported by a group of NASA mentors from different centers.

dust mitigation↗

Reference Interferometer Using a Semiconductor Laser/LED Reference Source in a Cryogenic Fourier-Transform Spectrometer

A combination of a single mode AlGaAs laser diode and broadband LED was used in a Michelson interferometer to provide reference signals in a Fourier transform spectrometer, the Composite Infrared Spectrometer, on the Cassini mission to Saturn. The narrowband light from the laser produced continuous fringes throughout the travel of the interferometer, which were used to control the velocity of the scan mechanism and to trigger data sampling. The broadband light from the LED produced a burst of fringes at zero path difference, which was used as a fixed position reference. The system, including the sources, the interferometer, and the detectors, was designed to work both at room temperature and instrument operating temperature of 170 Kelvin. One major challenge that was overcome was preservation, from room temperature to 170 K, of alignment sufficient for high modulation of fringes from the broadband source. Another was the shift of the source spectra about 30 nm toward shorter wavelengths upon cooldown.

Martino, Anthony J.↗

GISMO

The 2 mm (1 50 GHz) atmospheric window enables unparalleled ground-based observations of the earliest active dusty galaxies in the universe. We have undertaken the development of a bolometer camera, GISMO (the Goddard-IRAM Superconducting 2-Millimeter Observer), which will obtain large and sensitive sky maps at this wavelength. The instrument will be used at the IRAM 30 m telescope, where we hope to have a trial observing run in Spring of 2007. The innovative element in this camera is its 8x1 6 fully sampled planar array of multiplexed superconducting transition edge sensor bolometers. This array is based on our recently demonstrated Backshort Under Grid architecture, designed to be scaled to kilopixel arrays with high sensitivity (of around 4 * 10 (exp -17)/ W* square root of Hz at T(sub c) approximates 450mK). A compact cryogenic optical system provides a wide field of view, (almost 2'x4') enabling GISMO to be very efficient at detecting sources serendipitously in large sky surveys, while retaining diffraction-limited imaging performance. GISMO will provide significantly greater imaging sensitivity and mapping speed at this wavelength than has previously been possible. The major scientific driver for the instrument is to detect dust emission from high-z Ultraluminous Infrared Galaxies (ULIRGs) and quasars. The instrument provides an important portion of the spectrum of high redshift galaxies at the Rayleigh-Jeans part of the dust emission spectrum, even at the highest redshifts. Models of galaxy evolution predict that GISMO will serendipitously detect one galaxy in every four hours of observing blank sky, and that one quarter of these galaxies will be at a redshift of z > 6.5.

Benford, Dominic↗

Evaluation of Surlyn 8920 as PHE Visor Material and Evaluations of New Adhesives for Improving Bonding Between Teflon and Stainless Steel at Cryogenic Temperature

Two studies are presented, and in the first study, Surlyn 8920 (an ionic and amorphous low density polyethylene made by Dupont) was evaluated as a possible replacement of Plexyglass G as PHE visor material. Four formulations of the polymer were made by adding different amounts of UV stabilizer, energy quencher, and antioxident in a Brabender Plasticorder. The formulated polymers were molded in the form of sheets in a compression molder. Cut samples from the molded sheets were exposed in a weatherometer and tested on Instron Tensile Tester for strength and elongation. Specially molded samples of the formulated polymers were subjected to Charpy Impact Tests. In the second study, preliminary evaluations of adhesives for improvement of bonding between Teflon and stainless steel (SS) were performed. Kapton, a high temperature polyimide made by Dupont, and a rubber based adhesive made by Potter Paint Co., were evaluated against industrial quality epoxy, the current material used to bond Teflon and SS. The degreased surfaces of the SS discs were etched mechanically, with a few of these etched chemically. The surfaces of the SS discs were etched mechanically, with a few of these etched chemically. Bonding strengths were evaluated using lap shear tests on the Instron Tensile Tester for the samples bonded by Kapton and industrial quality epoxy. Bond strengths were also evaluated using a pull test on the Instron for the samples bonded by Potter adhesive (CWL-152) and industrial quality epoxy. Based on limited lap shear data, Kapton gave bond strength favorable compared to that of industrial epoxy. Based on limited pull test data, Kapton bonded and CWL-152 bonded samples showed poor strength compared to epoxy bonded sample.

Ray, Asit K.↗

Wire and Cable Cold Bending Test

One of the factors in assessing the applicability of wire or cable on the lunar surface is its flexibility under extreme cold conditions. Existing wire specifications did not address their mechanical behavior under cold, cryogenic temperature conditions. Therefore tests were performed to provide this information. To assess this characteristic 35 different insulated wire and cable pieces were cold soaked in liquid nitrogen. The segments were then subjected to bending and the force was recorded. Any failure of the insulation or jacketing was also documented for each sample tested. The bending force tests were performed at room temperature to provide a comparison to the change in force needed to bend the samples due to the low temperature conditions. The results from the bending tests were plotted and showed how various types of insulated wire and cable responded to bending under cold conditions. These results were then used to estimate the torque needed to unroll the wire under these low temperature conditions.

Colozza, Anthony↗