Search NASA⌕ Search

SEARCH · Search NASA

Results for “current status”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Woody Plant Transformation: Current Status, Challenges, and Future Perspectives

Woody plants, comprising forest and fruit tree species, provide essential ecological and economic benefits to society. Their genetic improvement is challenging due to long generation intervals and high heterozygosity. Genetic transformation, which combines targeted DNA delivery with plant regeneration from transformed cells, offers a powerful alternative to accelerating their domestication and improvement. Agrobacterium tumefaciens, Rhizobium rhizogenes, and particle bombardment have been widely used for DNA delivery into a wide variety of explants, including leaves, stems, hypocotyls, roots, and embryos, with regeneration occurring via direct organogenesis, callus-mediated organogenesis, somatic embryogenesis, or hairy root formation. Despite successes, conventional approaches are hampered by low efficiency, genotype dependency, and a reliance on challenging tissue culture. This review provides a critical analysis of the current landscape in woody plant transformation, moving beyond a simple summary of techniques to evaluate the co-evolution of established platforms with disruptive technologies. Key advances among these include the use of developmental regulators to engineer regeneration, the rise in in planta systems to bypass tissue culture, and the imperative for DNA-free genome editing to meet regulatory and public expectations. By examining species-specific breakthroughs in key genera, including Populus, Malus, Citrus, and Pinus, this review highlights a paradigm shift from empirical optimization towards rational, predictable engineering of woody plants for a sustainable future.

Agrobacterium tumefaciens↗

Current Status of Shock Layer Radiation Studies for Planetary Probes

Radiative heating by the shock layer gases surrounding an entry probe is an important heating mechanism for many planetary entries. The magnitude of radiative heating for planetary atmospheres may be characterized with flight similarity in a shock tube capable of obtaining flight relevant velocities and atmospheric density/composition. Over the last decade, studies performed in the Electric Arc Shock Tube (EAST) at NASA Ames have characterized the radiative heating magnitudes for most relevant planetary destinations: Mars, Venus, Titan, Saturn, Uranus. Predictions of heating for a given entry trajectory are simulated by a combination of hypersonic flowfield modeling and the radiation code, NEQAIR, and then compared to the EAST test data. This paper will discuss the measurements, summarize the current simulation capability and provide indications for destination specific radiative heating uncertainties.

Cruden, Brett A.↗

Quantum dot based memory devices: Current status and future prospect by simulation perspective

We discuss the simulation of floating gate MOSFET memory performance consists of Si/Ge/Si quantum dots for electronics storage nodes with higk-κ material as the tunnel oxide. Heterostructure quantum dot was proposed to maintain the good memory performance without losing the long retention characteristic. As the results, retention time could be increase significantly without deteriorating the writing/erasing speed. By selected the dot size of 9–15nm and the tunnel oxide thickness of 2nm, the retention characteristic can reach up to 10{sup 9}s while the writing and erasing time at the order of 10{sup −6}s. By replace the SiO{sub 2} tunnel oxide with high-κ material such as HfO{sub 2}, ZrO{sub 2}, and Y{sub 2}O{sub 3} the leakage current due to the shrinkage of tunnel oxide thickness can be suppressed by the factor of 10 for the EOT lower than ∼1nm. Moreover, the charge-trapping that generated by the defect at Si substrate and higk-κ material interface are fully considered. We found that, the charge-trapping affects the retention time and memory operation performance. By increasing the charge-trapping depth and width, the memory operation time decrease significantly while the retention characteristic slightly improved.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current status of tritium calorimetry at TLK

Inside a tritium facility, calorimetry is an important analytical method as it is the only reference method for accountancy (it is based on the measurement of the heat generated by the radioactive decay). Presently, at Tritium Laboratory Karlsruhe (TLK), 4 calorimeters are in operation, one of isothermal type and three of inertial guidance control type (IGC). The volume of the calorimeters varies between 0.5 and 20.6 liters. About two years ago we started an extensive work to improve our calorimeters with regard to reliability and precision. We were forced to upgrade 3 of our 4 calorimeters due to the outdated interfaces and software. This work involved creating new LabView programs driving the devices, re-tuning control loops and replacing obsolete hardware components. In this paper we give a review on the current performance of our calorimeters, comparing it to recently available devices from the market and in the literature. We also show some ideas for a next generation calorimeter based on experiences with our IGC calorimeters and other devices reported in the literature. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Greenhouse gas emissions from the global transportation of crude oil: Current status and mitigation potential

Global crude-oil transportation contributes a significant portion of greenhouse gas (GHG) emissions in the marine transportation sector. In this work, we first compile a detailed country-level global crude-oil transportation network in 2018 and estimate that the direct and well-to-hull GHG emissions related to crude transportation were 97 and 109 million metric tons, respectively. Combining with the country-specific crude recovery GHG intensities, the consumption-based well-to-country-gate crude-oil GHG intensities are derived for individual countries, ranging from 2.99 to 27.32 g CO 2 eq/MJ, with a global crude-volume-weighted average of 8.67 g CO 2 eq/MJ. We then project the global crude transportation emissions at the regional level in 2050 under a static (no change) scenario (based on current ship energy efficiency) and a sustainable-development (SD) scenario (based on the International Energy Agency's projections of ship energy efficiency and penetration of alternative marine fuels). Results show that the global well-to-hull GHG emissions related to crude transportation would be 82 and 59 million metric tons in 2050 in the static and SD scenarios, respectively. To further evaluate the impact of potential fuel-switching on decarbonizing the crude oil transportation sector, we estimate the GHG emissions for 20 fuel/production options in 2050. We find that, in comparison to the static scenario, ~50% reduction in global well-to-hull GHG emissions from crude transportation could be achieved under the SD scenario if green ammonia further replaces conventional ammonia. The methodology developed here can be applied to other commodities to estimate the emissions associated with their global marine transportation and to evaluate the potential emission mitigation options.

54 ENVIRONMENTAL SCIENCES↗

Environmental DNA as a tool for hydropower impact assessments: current status, special considerations, and future integration

Globally there is an urgent need to find sustainable solutions to balance energy production with the protection of vulnerable species and conservation of biodiversity. This is particularly critical for freshwater ecosystems, habitats, and species that may be impacted by hydropower development and operations needed to meet energy grid demands. Reliable and accurate environmental impact assessments (EIAs) that identify the biological, physical, or social impacts of hydropower are key to ensure biodiversity, ecosystem, and societal sustainability. The analysis of environmental DNA (eDNA) has the potential to transform hydropower EIAs, management and mitigation planning, and decision-making procedures. Further, the incorporation of eDNA surveys into EIAs during both hydropower planning and continued operations may streamline regulatory processes by improving our understanding of potentially impacted biota and habitats and evaluating environmental impacts mitigation. Here, we: (i) highlight current understanding and use of eDNA in freshwater environments; (ii) examine critical considerations for eDNA integration into hydropower EIAs and biological monitoring; (iii) identify knowledge gaps in eDNA analysis and applications unique to hydropower-regulated systems; and (iv) discuss future opportunities to bolster the incorporation of eDNA into hydropower research including regulatory acceptance and public engagement. While we acknowledge that there are several factors that may complicate the broad adoption of eDNA as a tool for assessing the impacts of hydropower, we anticipate that growing confidence in eDNA through hydropower-specific protocols, calibrations, and validations will overcome these inherent uncertainties.

aquatic biodiversity↗

The Global Satellite Precipitation Constellation: Current Status and Future Requirements

To address the need to map precipitation on a global scale a collection of satellites carrying passive microwave (PMW) radiometers has grown over the last 20 years to form a constellation of about 10-12 sensors at any one time. Over the same period, a broad range of science and user communities has become increasingly dependent on the precipitation products provided by these sensors. The constellation presently consists of both conical and cross-track scanning precipitation-capable multi-channel instruments, many of which are beyond their operational and design lifetime but continue to operate through the cooperation of the responsible agencies. The Group on Earth Observations and the Coordinating Group for Meteorological Satellites (CGMS), among other groups, have raised the issue of how a robust, future precipitation constellation should be constructed. The key issues of current and future requirements for the mapping of global precipitation from satellite sensors can be summarised as providing: 1) sufficiently fine spatial resolutions to capture precipitation-scale systems and reduce the beam-filling effects of the observations; 2) a wide channel diversity for each sensor to cover the range of precipitation types, characteristics and intensities observed across the globe; 3) an observation interval that provides temporal sampling commensurate with the variability of precipitation; and 4) precipitation radars and radiometers in low inclination orbit to provide a consistent calibration source, as demonstrated by the first two spaceborne radar/radiometer combinations on the Tropical Rainfall Measuring Mission (TRMM) and Global Precipitation Measurement (GPM) mission Core Observatory (CO). These issues are critical in determining the direction of future constellation requirements, while preserving the continuity of the existing constellation necessary for long-term climate-scale studies.

Precipitation↗

Current Status of Single Particle Imaging with X-ray Lasers

The advent of ultrafast X-ray free-electron lasers (XFELs) opens the tantalizing possibility of the atomic-resolution imaging of reproducible objects such as viruses, nanoparticles, single molecules, clusters, and perhaps biological cells, achieving a resolution for single particle imaging better than a few tens of nanometers. Improving upon this is a significant challenge which has been the focus of a global single particle imaging (SPI) initiative launched in December 2014 at the Linac Coherent Light Source (LCLS), SLAC National Accelerator Laboratory, USA. A roadmap was outlined, and significant multi-disciplinary effort has since been devoted to work on the technical challenges of SPI such as radiation damage, beam characterization, beamline instrumentation and optics, sample preparation and delivery and algorithm development at multiple institutions involved in the SPI initiative. Currently, the SPI initiative has achieved 3D imaging of rice dwarf virus (RDV) and coliphage PR772 viruses at ~10 nm resolution by using soft X-ray FEL pulses at the Atomic Molecular and Optical (AMO) instrument of LCLS. Meanwhile, diffraction patterns with signal above noise up to the corner of the detector with a resolution of ~6 Ångström (Å) were also recorded with hard X-rays at the Coherent X-ray Imaging (CXI) instrument, also at LCLS. Achieving atomic resolution is truly a grand challenge and there is still a long way to go in light of recent developments in electron microscopy. However, the potential for studying dynamics at physiological conditions and capturing ultrafast biological, chemical and physical processes represents a tremendous potential application, attracting continued interest in pursuing further method development. In this paper, we give a brief introduction of SPI developments and look ahead to further method development.

36 MATERIALS SCIENCE↗

Block-structured grids for complex aerodynamic configurations: Current status

The status of CFD methods based on the use of block-structured grids for analyzing viscous flows over complex configurations is examined. The objective of the present study is to make a realistic assessment of the usability of such grids for routine computations typically encountered in the aerospace industry. It is recognized at the very outset that the total turnaround time, from the moment the configuration is identified until the computational results have been obtained and postprocessed, is more important than just the computational time. Pertinent examples will be cited to demonstrate the feasibility of solving flow over practical configurations of current interest on block-structured grids.

Vatsa, Veer N.↗

Low-rank coal drying technologies current status and new developments

Despite their vast reserves, low-rank coals are considered undesirable because their high moisture content entails high transportation costs, potential safety hazards in transportation and storage, and the low thermal efficiency obtained in combustion of such coals. Their high moisture content, greater tendency to combust spontaneously, high degree of weathering, and the dusting characteristics restrict widespread use of such coals. The price of coal sold to utilities depends upon the heating value of the coal. Thus, removal of moisture from low-rank coals (LRC) is an important operation. Furthermore, LRC can be used cost effectively for pyrolysis, gasification, and liquefaction processes. This article provides an overview the diverse processes both those that utilize conventional drying technologies and those that are not yet commercialized and hence in need of RD. Relative merits and limitations of the various technologies and the current state of their development are presented. Drying characteristics of low-rank coal as well as factors affecting drying characteristics of coal samples are also discussed.

01 COAL, LIGNITE, AND PEAT↗

Nanodosimetry: Principle and Current Status

Due to the success of theoretical track structure Monte Carlo simulations, showing that features of ionization patterns on the nanometer level are important for the biological effectiveness of ionizing radiation, several new methods for experimental track structure investigations have been developed in recent years. These methods all use the principle of density scaling in low-pressure gas to probe track structure in macroscopic dimensions, ideally with single-ionization resolution. The new field of experimental track structure investigation, which has been called nanodosimetry, can be approached in two ways: (1) the number of ionizations in a defined, ideally wall-less, sensitive volume is registered per single primary particle and cluster size distributions are obtained, or (2) the full track structure of an ion track segment is 'imaged'. Existing nanodosimetric methods are based on the first approach, but a track structure imaging detector is currently under development at Loma Linda University. This contribution will review the principle and existing technical approaches to nanodosimetry and will give an outlook on future developments and applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Current Status of High Performance Large Format Si:As IBC Detectors for SOFIA-like Applications

Airborne and space telescope astronomical observations in the 5-25 micrometer wavelength region, are critical for understanding the physical conditions, composition, chemistry, and excitation of many environments in the interstellar medium, external galaxies, solar system objects, extra-solar systems, and stars. The scientific impact is particularly unique in the 5-8 micrometer and 14-25 micrometer regions which are inaccessible or poorly observed from ground-based observatories. Large-format area mid-infrared (MIR) detectors sensitive over these wavelengths and operable under moderate backgrounds (greater than 10(circumflex)6 e-/s at R=2000, 10(micrometers)) are essential for efficient large-area survey imaging and for taking moderate resolution spectra over a large spectral range. Both SOFIA and passively cooled Explorer observatories could benefit from this technology. Current first-light SOFIA instruments use small-format MIR FPA's of sizes 128x128 and 256x256, With the collaboration of Raytheon Infrared Operations (RIO), NASA-ARC has been testing the first device of this kind, a combination of 1) the ALADDIN III readout multiplexer, cryo-processed for 6K operation, with 2) SIRTF IRAC-like Sides IBC detector material. designed for higher QE and low dark current. Here we report requirements. design, and initial fabrication and testing of the first 1024x1024 Si:As IBC mid-IR detector array for these conditions. This device has exhibited low dark current, moderate noise levels, and greater than 200,000 electron linear well size at 6K operation. We conclude with suggestions for future device development for optimal performance under moderate background, SOFIA- and low Earth orbit observing conditions.

Ennico, Kimberly↗

In vivo small animal imaging: Current status and future prospects

The use of small animal models in basic and preclinical sciences constitutes an integral part of testing new pharmaceutical agents prior to commercial translation to clinical practice. Whole-body small animal imaging is a particularly elegant and cost-effective experimental platform for the timely validation and commercialization of novel agents from the bench to the bedside. Biomedical imaging is now listed along with genomics, proteomics, and metabolomics as an integral part of biological and medical sciences. Miniaturized versions of clinical diagnostic modalities, including but not limited to microcomputed tomography, micromagnetic resonance tomography, microsingle-photon-emission tomography, micropositron-emission tomography, optical imaging, digital angiography, and ultrasound, have all greatly improved our investigative abilities to longitudinally study various experimental models of human disease in mice and rodents. After an exhaustive literature search, the authors present a concise and critical review of in vivo small animal imaging, focusing on currently available modalities as well as emerging imaging technologies on one side and molecularly targeted contrast agents on the other. Aforementioned scientific topics are analyzed in the context of cancer angiogenesis and innovative antiangiogenic strategies under-the-way to the clinic. Proposed hybrid approaches for diagnosis and targeted site-specific therapy are highlighted to offer an intriguing glimpse of the future.

60 APPLIED LIFE SCIENCES↗

Current Status of NASA’s Low-Cost Optical Terminal (LCOT) at Goddard Space Flight Center

This paper provides the status of ongoing work at NASA-Goddard Space Flight Center (GSFC) to build a low-cost flexible ground terminal for optical communication. For laser communication to be cost-effective for future missions, a global network of flexible optical terminals must be put in place. There is a need for a single ground terminal design capable of supporting multiple missions ranging from LEO to lunar distances. NASA’s Low-Cost Optical Terminal (LCOT) has a single modular design that can be quickly reconfigured to support different laser communications missions. The LCOT prototype uses a 70cm commercially available telescope designed with optical and quantum communications in mind. This telescope is currently being integrated with a state-of-the-art adaptive optics system, and novel high-power laser amplifier demonstrate its utility as an optical communications receiver by receiving a downlink from the recently launched Laser Communication Relay Demonstration (LCRD). LCOT uses commercially available components wherever possible, and where commercial options are not available, the LCOT team works with vendors to create commercial options. This paper discusses the development progress for the blueprint of NASA’s future global ground terminal network.

Laser communications↗

D 3 -creatine dilution for skeletal muscle mass measurement: historical development and current status

The French chemist Michel Eugène Chevreul discovered creatine in meat two centuries ago. Extensive biochemical and physiological studies of this organic molecule followed with confirmation that creatine is found within the cytoplasm and mitochondria of human skeletal muscles. Two groups of investigators exploited these relationships five decades ago by first estimating the creatine pool size in vivo with 14 C and 15 N labelled isotopes. Skeletal muscle mass (kg) was then calculated by dividing the creatine pool size (g) by muscle creatine concentration (g/kg) measured on a single muscle biopsy or estimated from the literature. This approach for quantifying skeletal muscle mass is generating renewed interest with the recent introduction of a practical stable isotope (creatine-(methyl-d 3 )) dilution method for estimating the creatine pool size across the full human lifespan. The need for a muscle biopsy has been eliminated by assuming a constant value for whole-body skeletal muscle creatine concentration of 4.3 g/kg wet weight. The current single compartment model of estimating creatine pool size and skeletal muscle mass rests on four main assumptions: tracer absorption is complete; tracer is all retained; tracer is distributed solely in skeletal muscle; and skeletal muscle creatine concentration is known and constant. Three of these assumptions are false to varying degrees. Not all tracer is retained with urinary isotope losses ranging from 0% to 9%; an empirical equation requiring further validation is used to correct for spillage. Not all tracer is distributed in skeletal muscle with non-muscle creatine sources ranging from 2% to 10% with a definitive value lacking. Lastly, skeletal muscle creatine concentration is not constant and varies between muscles (e.g. 3.89–4.62 g/kg), with diets (e.g. vegetarian and omnivore), across age groups (e.g. middle-age, ~4.5 g/kg; old-age, 4.0 g/kg), activity levels (e.g. athletes, ~5 g/kg) and in disease states (e.g. muscular dystrophies, <3 g/kg). Some of the variability in skeletal muscle creatine concentrations can be attributed to heterogeneity in the proportions of wet skeletal muscle as myofibres, connective tissues, and fat. These observations raise serious concerns regarding the accuracy of the deuterated-creatine dilution method for estimating total body skeletal muscle mass as now defined by cadaver analyses of whole wet tissues and in vivo approaches such as magnetic resonance imaging. A new framework is needed in thinking about how this potentially valuable method for measuring the creatine pool size in vivo can be used in the future to study skeletal muscle biology in health and disease.

body composition↗

WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in the spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical and improved its performance. In addition, this is a very active area of research and further improvements are expected through further technological improvements. Learning Objectives: Basic principles of multi-energy CT Current implementations of mutli-energy CT Data and image analysis methods in multi-energy CT Current clinical applications of dual energy CT5. recent innovations and anticipated advances in multi-energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fiber Loop Ringdown — a Time-Domain Sensing Technique for Multi-Function Fiber Optic Sensor Platforms: Current Status and Design Perspectives

Fiber loop ringdown (FLRD) utilizes an inexpensive telecommunications light source, a photodiode, and a section of single-mode fiber to form a uniform fiber optic sensor platform for sensing various quantities, such as pressure, temperature, strain, refractive index, chemical species, biological cells, and small volume of fluids. In FLRD, optical losses of a light pulse in a fiber loop induced by changes in a quantity are measured by the light decay time constants. FLRD measures time to detect a quantity; thus, FLRD is referred to as a time-domain sensing technique. FLRD sensors have near real-time response, multi-pass enhanced high-sensitivity, and relatively low cost (i.e., without using an optical spectral analyzer). During the last eight years since the introduction of the original form of fiber ringdown spectroscopy, there has been increasing interest in the FLRD technique in fiber optic sensor developments, and new application potential is being explored. This paper first discusses the challenging issues in development of multifunction, fiber optic sensors or sensor networks using current fiber optic sensor sensing schemes, and then gives a review on current fiber optic sensor development using FLRD technique. Finally, design perspectives on new generation, multi-function, fiber optic sensor platforms using FLRD technique are particularly presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗