Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Classification of computed thermal tomography images with deep learning convolutional neural network

Thermal tomography (TT) is a computational method for the reconstruction of depth profile of the internal material defects from Pulsed Infrared Thermography (PIT) nondestructive evaluation. Here, the PIT method consists of recording material surface temperature transients with a fast frame infrared camera, following thermal pulse deposition on the material surface with a flashlamp and heat diffusion into material bulk. TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of the subsurface internal defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to the heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify the size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. The performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shapes imported from scanning electron microscopy images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on the TT images of elliptical defects is capable of classifying the shape and orientation of irregular defects.

42 ENGINEERING↗

Energy shadowing correction of ultrasonic pulse-echo records by digital signal processing

A numerical algorithm is described that enables the correction of energy shadowing during the ultrasonic testing of bulk materials. In the conventional method, an ultrasonic transducer transmits sound waves into a material that is immersed in water so that discontinuities such as defects can be revealed when the waves are reflected and then detected and displayed graphically. Since a defect that lies behind another defect is shadowed in that it receives less energy, the conventional method has a major drawback. The algorithm normalizes the energy of the incoming wave by measuring the energy of the waves reflected off the water/air interface. The algorithm is fast and simple enough to be adopted for real time applications in industry. Images of material defects with the shadowing corrections permit more quantitative interpretation of the material state.

Kishonio, D.↗

Measuring Three-Dimensional Strain and Structural Defects in a Single InGaAs Nanowire Using Coherent X-ray Multiangle Bragg Projection Ptychography

III - As nanowires are candidates for near-infrared light emitters and detectors that can be directly integrated onto silicon. However, nanoscale to microscale variations in structure, composition, and strain within a given nanowire, as well as variations between nanowires, pose challenges to correlating microstructure with device performance. In this work, we utilize coherent nanofocused X-rays to characterize stacking defects and strain in a single InGaAs nanowire supported on Si. By reconstructing diffraction patterns from the 2110 Bragg peak, we show that the lattice orientation varies along the length of the wire, while the strain field along the cross-section is largely unaffected, leaving the band structure unperturbed. Diffraction patterns from the 0110 Bragg peak are reproducibly reconstructed to create three-dimensional images of stacking defects and associated lattice strains, revealing sharp planar boundaries between different crystal phases of wurtzite (WZ) structure that contribute to charge carrier scattering. Phase retrieval is made possible by developing multiangle Bragg projection ptychography (maBPP) to accommodate coherent nanodiffraction patterns measured at arbitrary overlapping positions at multiple angles about a Bragg peak, eliminating the need for scan registration at different angles. The penetrating nature of X-ray radiation, together with the relaxed constraints of maBPP, will enable the in operando imaging of nanowire devices.

36 MATERIALS SCIENCE↗

Imaging Hindered Rotations of Alkoxy Species on TiO2(110)

We present the first study of the rotational dynamics of organic species on any oxide surface. Specifically, variable-temperature scanning tunneling microscopy (STM) and dispersion-corrected density functional theory are used to study the alkyl chain conformational disorder and dynamics of 1-, 2-, 3- and 4-octoxy on rutile TiO2(110). Initially, the geminate pairs of the octoxy and bridging hydroxyl species are created via octanol dissociation on bridging-oxygen (Ob) vacancy defects. The STM images provide time averaged snapshots of octoxy species rotating among multiple energetically nearly-degenerate configurations accessible at a given temperature. In the calculations we find that the underlying corrugated potential energy surface is a result of the interplay between attractive Van der Waals dispersion forces leading to weak attractive C...Ti and repulsive C...Ob interactions which lead to large barriers of 50-70kJmol-1 for the rotation of the octoxy alkyl chains across the Ob rows. In the presence of the germinal hydroxyl groups we find that the relative populations of the various conformations as well as the rotational barriers are perturbed by the presence of geminate hydroxyl due to additional C...hydroxyl repulsions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking Site-specific C-C Coupling of Formaldehyde Molecules on Rutile TiO2(110)

Direct imaging of site-specific reactions of individual mole-cules as a function of temperature is a long-sought goal in molecular science. Here, we report the direct visualization of molecular coupling of formaldehyde on reduced rutile TiO2(110) surfaces as we track the same set of molecules when the temperature is increased from 75 to 170 K using scanning tunneling microscope (STM). Our recent study showed that formaldehyde preferably adsorbs on bridging-bonded oxygen (Ob) vacancy (VO) defect site. Herein, images from the same area as the temperature is increased show that VO-bound formaldehyde couples with Ti-bound formaldehyde forming a diolate intermediate. Exposure of formaldehyde at room temperature leads to diolate as the majority species on the surface and no VO-bound formaldehyde is observed. The diolate species are the key reaction intermediates in the formation of ethylene reported in previous ensemble-averaged studies.

Environmental Molecular Sciences Laboratory↗

Defect Recognition for Eddy Current Testing of Spent Nuclear Fuel Canister using Convolutional Neural Network

This paper proposes an accurate and robust defect detection solution for 304L and 306L stainless steel (SS) weld. In the proposed solution, Eddy current testing (ECT) is employed to generate 2-dimensional (2D) data for samples under test with defects. The 2D data can be treated as images for deep learning-based defect detection. Since convolutional neural networks (CNNs) are powerful in processing images, CNN is employed in this study for defect detection. Experiments are conducted on a submerged arc welding (SAW) 304L SS weld sample with an artificial crack generated by waterjet cutting. The ECT data on this seeded fault sample is utilized to verify the proposed solution. For this purpose, the ECT measurement are separated as from Fault area and Normal area, which are used for CNN training. After training, the testing data is used for verification. Experimental results demonstrate the feasibility and effectiveness of the proposed solution.

Niu, Guangxing↗

Routine characterization of 3-D profiles of SRF cavity defects using replica techniques

Recent coordination of thermometry with optical images has shown that obvious defects at specific locations produce heat or even quench superconducting radio frequency (SRF) cavities, imposing a significant limit on the overall accelerating gradient produced by the cavity. Characterization of the topography at such locations provides clues about how the defects originated, from which schemes for their prevention might be devised. Topographic analyses also provide understanding of the electromagnetic mechanism by which defects limit cavity performance, from which viability of repair techniques might be assessed. In this article we discuss how a variety of two-component silicone-based room-temperature vulcanizing agents can be routinely used to make replicas of the cavity surface and extract topographic details of cavity defects. Previously, this level of detail could only be obtained by cutting suspect regions from the cavity, thus destroying the cavity. We show 3-D profiles extracted from several different 1.3 GHz cavities. The defect locations, which were all near cavity welds, compelled us to develop extraction techniques for both equator and iris welds as well as from deep inside long 9-cell cavities. Profilometry scans of the replicas yield micrometer-scale information, and we describe various curious features, such as small peaks at the bottom of pits, which were not apparent in previous optical inspections. We also discuss contour information in terms of electromagnetic mechanisms proposed by others for local cavity heating. We show that production of the replica followed by high-pressure rinsing dose not adversely affect the cavity RF performance.

43 PARTICLE ACCELERATORS↗

Data-driven imaging in anisotropic media

Anisotropic materials are being used increasingly in high performance industrial applications, particularly in the aeronautical and nuclear industries. Some important examples of these materials are composites, single-crystal and heavy-grained metals. Ultrasonic array imaging in these materials requires exact knowledge of the anisotropic material properties. Without this information, the images can be adversely affected, causing a reduction in defect detection and characterization performance. The imaging operation can be formulated in two consecutive and reciprocal focusing steps, i.e., focusing the sources and then focusing the receivers. Applying just one of these focusing steps yields an interesting intermediate domain. The resulting common focus point gather (CFP-gather) can be interpreted to determine the propagation operator. After focusing the sources, the observed travel-time in the CFP-gather describes the propagation from the focus point to the receivers. If the correct propagation operator is used, the measured travel-times should be the same as the time-reversed focusing operator due to reciprocity. This makes it possible to iteratively update the focusing operator using the data only and allows the material to be imaged without explicit knowledge of the anisotropic material parameters. Furthermore, the determined propagation operator can also be used to invert for the anisotropic medium parameters. This paper details the proposed technique and demonstrates its use on simulated array data from a specimen of Inconel single-crystal alloy commonly used in the aeronautical and nuclear industries.

36 MATERIALS SCIENCE↗

Defect Band Luminescence Intensity Reversal as Related to Application of Anti-Reflection Coating on mc-Si PV Cells: Preprint

Photoluminescence (PL) imaging is widely used to identify defective regions within mc-Si PV cells. Recent PL imaging investigations of defect band luminescence (DBL) in mc-Si have revealed a perplexing phenomenon. Namely, the reversal of the DBL intensity in various regions of mc-Si PV material upon the application of a SiNx:H anti-reflective coating (ARC). Regions with low DBL intensity beforeARC application often exhibit high DBL intensity afterwards, and the converse is also true. PL imaging alone cannot explain this effect. We have used high resolution cathodoluminescence (CL) spectroscopy and electron beam induced current (EBIC) techniques to elucidate the origin of the DBL intensity reversal. Multiple sub-bandgap energy levels were identified that change in peak position andintensity upon the application of the ARC. Using this data, in addition to EBIC contrast information, we provide an explanation for the DBL intensity reversal based on the interaction of the detected energy levels with the SiNx:H ARC application. Multiple investigations have suggested that this is a global problem for mc-Si PV cells. Our results have the potential to provide mc-Si PV producers apathway to increased efficiencies through defect mitigation strategies.

14 SOLAR ENERGY↗

A Lizard-inspired Tube Inspector (LTI) Robot

This final report summarizes the research findings of the current project. This project is a collaboration between New Mexico State University (NMSU) as a lead (Recipient) and Arizona State University (ASU) as a Co-Recipient. Tubular structures are common components of boilers and heat exchangers in power plants. Over time, these components may suffer corrosion, cracks, and stress-corrosion cracks in either the body or the welded connections. A single tube leakage can cause an outage of several weeks. Regular inspection is a key safety factor when ensuring that power plants are maintained in reliable, operational condition. This inspection, however, is challenging, time-consuming, and in many cases impossible due to accessibility issues and safety concerns. Recent developments in robotic-based inspection can offer a great solution. Hard-to-reach places can be inspected without overhauling the unit, saving time and cost. Although several robots have been designed and implemented successfully for inspecting power plant components, in particular tubular structures, their mobility and flexibility are limited. Most of these robots use wheels for mobility which reduces their maneuverability of these robots. Moreover, they usually use magnets to attach to tubes which will not work on tubes with non-ferromagnetic materials. These robots usually carry measurement tools for a particular non-destructive testing (NDT) method such as ultrasound testing (UT) that requires a couplant to perform a point-by-point (scanning) inspection of the tubular structure. In this project, we developed a versatile lizard-inspired tube inspector (LTI) robot with embedded inspection sensing components for tube inspection which removes the need for point-by-point scanning of tube surface for crack and corrosion detection. Inspired by a “lizard”, the novelty of the current project is the integration of couplant-free ultrasound sensing and transmission, advanced data-driven defect detection and imaging, and friction-based mechanical mobility components in a single robot to eliminate a need for smooth surfaces and simple geometry for mobility and scanning. The LTI robot could replace the wheel-based approach with friction-based mobility to significantly increase the flexibility and maneuverability of the robot. The LTI robot can get into a power plant unit, such as a boiler, from a small area allowing it to access a component of interest for inspection (e.g., move on OD, curved and flat surfaces, non-ferromagnetic or ferromagnetic materials, and tubes with rough surfaces and complex geometries). Additionally, an advanced data-driven method using ultrasound data was pioneered to allow the robot to detect defects in the entire area between the robot’s multi-functional mobility system (grippers). Integrating a couplant-free ultrasound sensing in the robot’s grippers as well as using advanced data-driven methods allowed the LTI to detect defects in the entire cross-section of a tube using its grippers when stationary and when mobile.

20 FOSSIL-FUELED POWER PLANTS↗

Fabrication of FeCrAl cladding for accident tolerant fuel

General Electric (GE) is working with the US Department of Energy (DOE) to develop a high performance nuclear fuel that will have enhanced tolerance to failure under severe accident conditions. The leading FeCrAl alloy candidate for the cladding is APMT, a powder metallurgy alloy developed by Kanthal/Sandvik for high temperature applications. Zirconium alloys have been used for cladding the fuel for over six decades. That is, zirconium alloys can be fabricated as several meters long tubes with an outside diameter of about 10 mm and a wall thickness in the order of 1 mm or less. The GE team is working to demonstrate that APMT can be fabricated as long thin walled tubes for the cladding application. A first production route for 10 x 0.5 mm APMT tubes was established showing that pilgering and drawing are viable processes to fabricate the APMT cladding. The mechanical properties of APMT were evaluated before and after the cold forming. Yield strength, tensile strength and hardness increased and elongation decreased due to cold forming, which was expected. No abnormality has been noted in the microstructures. The 3D image visualization of TIG welded APMT rodlet and the images of welding areas taken at different locations show no welding defects such as distortion, porosity or lack of penetration along/adjacent to the welded areas, confirming overall good welds and no opening or defects across the entire width of the tube thickness. Tests have shown no effect of welding on the hardness or mechanical strength in the area nearing the weld.

36 MATERIALS SCIENCE↗

Free software for performing physical analysis of systems for digital radiography and mammography

Purpose: In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks. Methods: The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag. Results: The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin. Conclusions: This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online ( http://www.medphys.it/downloads.htm ). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ring artifact and Poisson noise attenuation via volumetric multiscale nonlocal collaborative filtering of spatially correlated noise

X-ray micro-tomography systems often suffer from high levels of noise. In particular, severe ring artifacts are common in reconstructed images, caused by defects in the detector, calibration errors, and fluctuations producing streak noise in the raw sinogram data. Furthermore, the projections commonly contain high levels of Poissonian noise arising from the photon-counting detector. This work presents a 3-D multiscale framework for streak attenuation through a purposely designed collaborative filtering of correlated noise in volumetric data. A distinct multiscale denoising step for attenuation of the Poissonian noise is further proposed. By utilizing the volumetric structure of the projection data, the proposed fully automatic procedure offers improved feature preservation compared with 2-D denoising and avoids artifacts which arise from individual filtering of sinograms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unveiling defect-mediated carrier dynamics in monolayer semiconductors by spatiotemporal microwave imaging

The optoelectronic properties of atomically thin transition-metal dichalcogenides are strongly correlated with the presence of defects in the materials, which are not necessarily detrimental for certain applications. For instance, defects can lead to an enhanced photoconduction, a complicated process involving charge generation and recombination in the time domain and carrier transport in the spatial domain. Here, we report the simultaneous spatial and temporal photoconductivity imaging in two types of WS 2 monolayers by laser-illuminated microwave impedance microscopy. The diffusion length and carrier lifetime were directly extracted from the spatial profile and temporal relaxation of microwave signals, respectively. Time-resolved experiments indicate that the critical process for photoexcited carriers is the escape of holes from trap states, which prolongs the apparent lifetime of mobile electrons in the conduction band. As a result, counterintuitively, the long-lived photoconductivity signal is higher in chemical-vapor deposited (CVD) samples than exfoliated monolayers due to the presence of traps that inhibits recombination. Overall, our work reveals the intrinsic time and length scales of electrical response to photoexcitation in van der Waals materials, which is essential for their applications in optoelectronic devices.

42 ENGINEERING↗

Metal Halide Scintillators with Fast and Self‐Absorption‐Free Defect‐Bound Excitonic Radioluminescence for Dynamic X‐Ray Imaging

Abstract Scintillators for radiation detection are of great significance in medical imaging, security, and nondestructive inspection. The current challenge for scintillators is to simultaneously achieve high scintillation light yield, fast radioluminescence, simple film fabrication, large X‐ray attenuation efficiency as well as stable and nontoxic compositions; no previous scintillators fulfill all the above requirements. Here, metal halide Rb 2 AgBr 3 , possessing defect‐bound excitonic radioluminescence, is shown as efficient and fast scintillators. This nontoxic and stable scintillator emits from excitons bound to neutral bromine vacancies, enjoying an efficient and spin‐allowed fast emission with minimized self‐absorption. Rb 2 AgBr 3 thus has a high light yield (25 600 photons MeV −1 ), fast scintillation decay time (5.31 ns), and a record value of light yield versus decay time (4821 photons MeV −1 ns −1 ). The close‐space sublimation method is developed for fast and scalable fabrication of oriented Rb 2 AgBr 3 films. The scintillator film is further integrated with commercial flat‐panel imagers, and the spatial resolution reaches 10.2 line pairs per millimeter at the modulation transfer function of 0.2, doubling the resolution of conventional CsI:Tl flat‐panel detectors. The dynamic X‐ray imaging and its use to real‐time monitoring of bone movement without ghosting effect is also demonstrated.

Zhang, Muyi↗

Nano-scale microstructure damage by neutron irradiations in a novel Boron-11 enriched TiB 2 ultra-high temperature ceramic

Ultra-high temperature transition-metal ceramics are potential candidates for fusion reactor structural and plasma-facing components. We reveal the irradiation damage microstructural phenomena in Boron-11 enriched titanium diboride (TiB 2 ) using mixed-spectrum neutron irradiations, combined with state-of-art characterization using transmission electron microscopy (TEM) and high resolution TEM. Irradiations were performed using High Flux Isotope Reactor at ~220 and 620 °C up to 2.4 x 10 25 n.m -2 (E > 0.1 MeV). The calculated dose including contribution from residual Boron-10 ( 10 B) transmutation recoils, was ~4.2 displacements per atom. TiB 2 is susceptible to irradiation damage in terms of dislocation loop formation, cavities and anisotropic swelling induced micro-cracking. At both 220 and 620 °C, TEM revealed dislocation loops on basal and prism planes, with nearly two orders of magnitude higher number density of prism-plane loops. HRTEM, electron diffraction and relrod imaging revealed additional defects on {10$ \overline{1}\ $0} planes, identified as faulted prism-plane dislocation loops. High defect cluster density on prism planes will induce a-lattice parameter swelling of TiB 2 , as reported in literature. This anisotropic lattice parameter swelling induced grain boundary micro-cracking, the extent of which decreased with increasing irradiation temperature. The dominance of irradiation defect clusters on prism planes is different than typical hexagonal ceramics where dislocation loops predominantly form on basal planes, causing c-lattice parameter swelling. Helium generation and temperature rise from the transmutation of residual 10 B resulted in matrix and grain boundary cavities for the irradiation at 620 °C. In conclusion, the study additionally signifies isotopic enrichment as a viable approach to produce transition-metal diborides for potential nuclear structural applications.

36 MATERIALS SCIENCE↗