Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Threshold photoelectron source for the study of low-energy electron scattering: Total cross section for electron scattering from krypton in the energy range from 14 meV to 20 eV

An experimental technique for the measurement of the total cross section for electron scattering from atoms and molecules at high resolution is described. The total cross sections for electron scattering from Kr in the energy range from 14 meV to 20 eV obtained with the technique are also reported. The present technique employs a combination of the penetrating field technique and the threshold photoionization of rare-gas atoms using synchrotron radiation as an electron source in order to produce a high-resolution electron beam at very low energy. The characteristics of the electron sources were determined by measuring the ionizing photon energy dependence of photoelectron yield. Absolute total cross sections for electron scattering are obtained by the attenuation method. The measured absolute values of the total cross sections for electron scattering from Kr agree with those obtained by other groups down to 175 meV, above which several experimental works have been reported. Below 175 meV, the present results generally agree with theoretical cross sections down to 14 meV. The resonant structures in the total cross sections due to Kr{sup -} (4p{sup 5}5s{sup 2} {sup 2}P{sub 3/2}) and the Kr{sup -} (4p{sup 5}5s{sup 2} {sup 2}P{sub 1/2}) Feshbach resonances are also reported. The resolution of the present setup has been estimated from a fit of the measured profile of the Kr{sup -} (4p{sup 5}5s{sup 2} {sup 2}P{sub 3/2}) resonance by the theoretical curve obtained from the resonant scattering theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Ion optics of RHIC electron beam ion source

RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

43 PARTICLE ACCELERATORS↗

Note: Design and initial results of a multi-pulsed intense electron beam source

A multi-pulsed intense electron beam source is introduced, including the design and the initial experimental results. The source can generate a burst of three pulses of intense electron beams with energy of 2–3 MeV and beam intensities of around 2.5 kA. An inductive adder is chosen to generate the pulsed diode voltages and a dispenser cathode is chosen to emit electron beams. The test results indicate that the design of the source is reliable. The multi-pulsed diode voltage is up to 2.5 MV and the beam intensities are more than 2 kA at the exit of the source with small variation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Photoemission characterization of N-polar III-nitride photocathodes as candidate bright electron beam sources for accelerator applications

We report on the growth and characterization of a new class of photocathode structures for use as electron sources to produce high brightness electron beams for accelerator applications. The sources are realized using III-nitride materials and are designed to leverage the strong polarization field, which is characteristic of this class of materials when grown in their wurtzite crystal structure, to produce a negative electron affinity condition without the use of Cs, possibly allowing these materials to be operated in radio frequency guns. A Quantum Efficiency (QE) of about 1×10−3 and an emitted electrons’ Mean Transverse Energy (MTE) of about 100 meV are measured at a wavelength of 265 nm. In a vacuum level of 3×10−10 Torr, the QE does not decrease after more than 24 h of continuous operation. The lowest MTE of about 50 meV is measured at 300 nm along with a QE of 1.5×10−5. Surface characterizations reveal a possible contribution to the MTE from surface morphology, calling for more detailed studies.

Cultrera, L. (ORCID:0000000235606059)↗

Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of closed shell breeding of cesium ions with an electron beam ion source

An electron beam ion source serves as a charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) at the Argonne Tandem Linac Accelerator System (ATLAS). The source accepts radioactive beams of 1+ or 2+ ions and raises their charge state for post-acceleration by ATLAS. The efficiency of this process impacts the length of each experiment and, hence, the type and number of experiments that can be run in each program cycle. Recent efforts to improve the charge breeding efficiency for the 80 < A < 160 species typical of CARIBU have focused on utilizing the closed shell breeding technique. Here, with this technique, the electron beam energy is manipulated to take advantage of the large gap in ionization energies at shell closures and selectively populate a single charge state. Charge breeding studies with stable cesium ions have demonstrated an absolute efficiency of 72% for Cs 27+ and a total efficiency of 93%. The Cs 27+ efficiency result represents a factor of 3 improvement over the previous best charge breeding result of 23% for Cs 27+ .

Vondrasek, R. [Argonne National Laboratory (ANL), ↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deduction of edge electron density with multiply charged ions in ORNL volume-type electron cyclotron resonance ion source

The electron densities in the argon plasmas of the ORNL 6 GHz electron cyclotron resonance (ECR) ion source with a flat central magnetic field have been deduced from the ion branches of the electric probe current-voltage curves measured in the edge region of the plasmas. To overcome the difficulties due to unknown velocities of multiply charged ions at the sheath edge, a modified generalized Bohm criterion for the ion sheath velocity is introduced and the mean velocity of all ionic charge states at the sheath edge is assumed to be equal to the sound velocity of the system of particles. The calculated electron densities and temperatures for different plasmas optimized for four charge state distributions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-284: Revisiting Reference Dosimetry for the Model S700 Axxent 50 KV{sub p} Electronic Brachytherapy Source

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft was characterized in 2006 by Rivard et al. The source design was modified in 2006 to include a plastic centering insert at the source tip to more accurately position the anode. The objectives of the current study were to establish an accurate Monte Carlo source model for simulation purposes, to dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and to determine dose differences between the source with and without the centering insert. Methods: Design information from dissected sources and vendor-supplied CAD drawings were used to devise the source model for radiation transport simulations of dose distributions in a water phantom. Collision kerma was estimated as a function of radial distance, r, and polar angle, θ, for determination of reference TG-43 dosimetry parameters. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.03% at r=1 cm and 0.08% at r=10 cm. Results: The dose rate distribution the transverse plane did not change beyond 2% between the 2006 model and the current study. While differences exceeding 15% were observed near the source distal tip, these diminished to within 2% for r>1.5 cm. Differences exceeding a factor of two were observed near θ=150° and in contact with the source, but diminished to within 20% at r=10 cm. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% over a third of the available solid angle external from the source. For clinical applications using balloons or applicators with tissue located within 5 cm from the source, dose differences exceeding 2% were observed only for θ>110°. This study carefully examined the current source geometry and presents a modern reference TG-43 dosimetry dataset for the model S700 source.

60 APPLIED LIFE SCIENCES↗

Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source

The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current ({approx}100 {micro}A) with high charge ({approx}10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

43 PARTICLE ACCELERATORS↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Generation of metal ions in the beam plasma produced by a forevacuum-pressure electron beam source

We report on the production of metal ions of magnesium and zinc in the beam plasma formed by a forevacuum-pressure electron source. Magnesium and zinc vapor were generated by electron beam evaporation from a crucible and subsequently ionized by electron impact from the e-beam itself. Both gaseous and metallic plasmas were separately produced and characterized using a modified RGA-100 quadrupole mass-spectrometer. The fractional composition of metal isotopes in the plasma corresponds to their fractional natural abundance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ignitor target studies for the HiPER project

Target studies for the proposed High Power Laser Energy Research (HiPER) facility [M. Dunne, Nature Phys. 2, 2 (2006)] are outlined and discussed. HiPER will deliver a 3{omega} (wavelength {lambda}=0.35 {mu}m), multibeam, multi-ns pulse of about 250 kJ and a 2{omega} or 3{omega} pulse of 70-100 kJ in about 15 ps. Its goal is the demonstration of laser driven inertial fusion via fast ignition. The baseline target concept is a direct-drive single shell capsule, ignited by hot electrons generated by a conically guided ultraintense laser beam. The paper first discusses ignition and compression requirements, and presents gain curves, based on an integrated model including ablative drive, compression, ignition and burn, and taking the coupling efficiency {eta}{sub ig} of the igniting beam as a parameter. It turns out that ignition and moderate gain (up to 100) can be achieved, provided that adiabat shaping is used in the compression, and the efficiency {eta}{sub ig} exceeds 20%. Using a standard ponderomotive scaling for the hot electron temperature, a 2{omega} or 3{omega} ignition beam is required to make the hot electron range comparable to the desired size of the hot spot. A reference target family is then presented, based on one-dimensional fluid simulation of compression, and two-dimensional fluid and hybrid simulations of fast electron transport, ignition, and burn. The sensitivity to compression pulse shape, as well as to hot electron source location, hot electron range, and beam divergence is also discussed. Rayleigh-Taylor instability at the ablation front has been addressed by a model and a perturbation code. Simplified simulations of code-guided target implosions have also been performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and performance of a spin-polarized electron energy loss spectrometer with high momentum resolution

We describe a new “complete” spin-polarized electron energy loss spectrometer comprising a spin-polarized primary electron source, an imaging electron analyzer, and a spin analyzer of the “spin-polarizing mirror” type. Unlike previous instruments, we have a high momentum resolution of less than 0.04 Å{sup −1}, at an energy resolution of 90-130 meV. Unlike all previous studies which reported rather broad featureless data in both energy and angle dependence, we find richly structured spectra depending sensitively on small changes of the primary energy, the kinetic energy after scattering, and of the angle of incidence. The key factor is the momentum resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗