Search NASA⌕ Search

SEARCH · Search NASA

Results for “faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Dissecting Disorder: Defect-Driven Structural Complexity in Layered Li3InCl6 Solid Electrolyte

Halide solid electrolytes have emerged as promising candidates for solid-state batteries owing to their high oxidative stability and ionic conductivity. Among them, Li3InCl6 (LIC) has attracted significant attention. However, diffraction patterns of LIC synthesized via different methods exhibit distinct differences particularly at low-angle reflectionsindicative of underlying structural disorder. These variations are attributed to deviations from ideal crystallographic order, especially stacking faults, whose impact on structure and ion transport remains poorly understood. Here, we identify and quantify stacking faults in LIC samples prepared under different synthetic conditions. Using X-ray diffraction and time-of-flight neutron diffraction, we construct and refine stacking fault models that accurately reproduce the experimental diffraction features. LIC samples with higher degrees of stacking faults exhibit only negligible differences in ionic conductivities and activation energies. This indicates that stacking faults have a limited impact on altering the Li+ diffusion pathway along the c-axis, likely due to the high concentration of vacancies in the In layers, while Li+ diffusion remains nearly unchanged in the ab-plane. Our results account for the observed differences in diffraction patterns across samples and provide a quantitative assessment of faulting probabilities and stacking sequences. The insights gained from this study are expected to be broadly applicable to other layered halide solid electrolytes and contribute to a deeper understanding of the role of structural disorder in ion transport.

Liu, Jue [ORNL] (ORCID:000000024453910X)↗

Seismic Features Predict Ground Motions During Repeating Caldera Collapse Sequence

Abstract Applying machine learning to continuous acoustic emissions, signals previously deemed noise, from laboratory faults and slowly slipping subduction‐zone faults, demonstrates hidden signatures are emitted that describe physical details, including fault displacement and friction. However, no evidence currently exists to demonstrate that similar hidden signals occur during seismogenic stick‐slip on earthquake faults—the damaging earthquakes of most societal interest. We show that continuous seismic emissions emitted during the 2018 multi‐month caldera collapse sequence at the Kı̄lauea volcano in Hawai'i contain hidden signatures characterizing the earthquake cycle. Multi‐spectral data features extracted from 30 s intervals of the continuous seismic emission are used to train a gradient boosted tree regression model to predict the GNSS‐derived contemporaneous surface displacement and time‐to‐failure of the upcoming collapse event. This striking result suggests that at least some faults emit such signals and provide a potential path to characterizing the instantaneous and future behavior of earthquake faults.

58 GEOSCIENCES↗

Fluid‐Driven Cohesive Strengthening: Critical Role of Reaction Kinetics as the Determinant for Frictional Stability

After an earthquake, faults in the Earth's crust lock up and slowly regain strength. This process, called fault healing, plays a key role in determining how often earthquakes happen and how large they can be. While scientists know that healing involves both mechanical friction and chemical changes in rocks, it has been unclear how these processes work together, especially over shorter timescales in laboratory settings. In our study, we ran controlled experiments on the mineral anhydrite under different fluid conditions. We found that the presence and pressure of water speeds up fault healing by triggering a chemical reaction that strengthens the fault over time. This strengthening makes the fault more resistant to sliding, which could delay future earthquakes—but also sets the stage for larger ones when they do occur. We propose a model that combines frictional and chemical processes to explain this water‐activated, time‐dependent healing. Importantly, our results show that even faults typically considered stable could still produce earthquakes if they undergo sufficient chemical healing. This has broad implications for understanding where and when earthquakes might strike, especially in fluid‐rich environments such as subduction zones and geoenergy settings.

Affinito, R [Pennsylvania State Univ., University ↗

Flag Gadgets Based on Classical Codes

Fault-tolerant syndrome extraction is a key ingredient in implementing fault-tolerant quantum computation. While conventional methods use a number of extra qubits that are linear in the weight of the syndrome, several improvements have been introduced using flag gadgets. In this work, we develop a framework to design flag gadgets using classical codes. Using this framework, we show how to perform fault-tolerant syndrome extraction for any stabilizer code with arbitrary distance using exponentially fewer qubits than conventional methods when qubit measurement and reset are relatively slow compared to a round of error correction. In particular, our method requires only ( 2 t + 1 ) t ⌈ log 2 ( w ) ⌉ flag qubits to fault-tolerantly measure a weight- w stabilizer. We further take advantage of the saving provided by our construction to fault-tolerantly measure multiple stabilizers using a single gadget and show that it maintains the same exponential advantage when it is used to fault-tolerantly extract the syndromes of quantum low-density parity-check codes. Using the developed framework, we perform computer-assisted search to find several small examples where our constructions reduce the number of qubits required. These small examples may be relevant to near-term experiments on small-scale quantum computers. Published by the American Physical Society 2024

Anker, Benjamin↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

Simulation of Physics-Based 0-10Hz Strong Motion Using High Performance Computing Supporting Refinements to Regional Ground Motion Models for the Central Eastern US

In collaboration with the U.S. Nuclear Regulatory Commission (NRC) the LLNL has developed a computationally efficient simulation platform designed to perform physics-based ground motion simulations for crustal earthquakes in the Stable Continental Regions of Central and Eastern US (CEUS), using high-performance computing. The main objective of the earthquake simulations was to use synthetic ground motion to provide constrains to refinements of existing ergodic Ground Motion Models (GMMs), for large magnitude earthquakes and near-fault distances, for which these models are less reliable. Physics-based broadband (0-10Hz) ground motion simulations were used to estimate the near-fault ground motion amplitudes and within event and between-event variabilities associated with fault rupture characteristics. In our simulations we used a 3D regional velocity model that was based on Saikia’s 1D velocity model (1994). In simulations performed during the first stage of this project the Saikia’s velocity model demonstrated better performance in modelling high frequency regional wave propagation for the CEUS region recorded during the Mw5.0 November 7, 2016, Cushing Oklahoma (Taylor et al., 2017), and Mw5.8 September 3, 2016, Pawnee Oklahoma earthquakes. The proposed regional 3D model includes random perturbations to the 1D background model using the stochastic scheme of Pitarka and Mellors (2021). In addition, validation analysis of the rupture generator and regional wave propagation models, using comparisons with different GMMs for Mw6.5 and Mw7.0 scenario earthquakes in the CEUS region resulted in a very good match between the simulated and empirical ground motion models. For the purposes of seismic hazard assessment at the existing and planned nuclear power plants, NRC is interested in studies aimed at improving the current ground motion models (GMM) for both Stable Continental Regions (SCR) in the Central and Eastern US and Active Crustal Regions (ACR) in the Western US. Due to lack of recorded data, these improvements require synthetic data for short fault distances and large magnitude earthquakes for which the existing recorded data is not enough to uniquely constrain the GMMs. The need for simulations and strong motion data is especially critical for the CEUS region where we do not have recorded data from potentially large damaging earthquakes with moment magnitudes 6.0 and higher. In this the project, we focused on 10Hz simulations of Mw7.0 scenario earthquakes with strike slip and thrust faulting mechanisms. We used more than 50 Mw7.0 earthquake rupture scenarios to investigate the ground motion uncertainty due to unknown earthquake rupture parameters, in particular, the slip distribution, rupture velocity, and faulting mechanism, and their implication on ground motion amplification due to forward rupture directivity effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

Geothermal Reservoir Characterization at Wattenberg Area in Denver Basin

The geothermal potential of the Denver-Julesburg (D-J) Basin is largely overlooked. This study focuses on characterizing the geothermal potential in the greater Wattenberg area within the Denver Basin, using available well data and subsurface information and gas wells drilled to above 2500 m deep. The review reveals that the main structures comprise ENE-trending wrench faults, along with NNE, N, and NNW trending normal faults. A thermal anomaly is present bonded by Lafayette and Longmont wrench faults and overlying vitrinite reflectance anomaly. The geometry of thermal anomaly suggests that it is influenced by Longmont wrench fault and Lafayette fault, as well as the basin margin fault. Bottom hole temperatures are of 160 Degrees Celsius, with thermal gradients of and 62 Degrees Celsius/km. Reservoir temperature estimates from thermal gradients suggest a range of >200 Degrees Celsius at depths of 3 km.

Denver basin↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microstructural evolution of compositionally complex solid-solution alloys under in-situ dual-beam irradiation

Here, this work attempts to link the microstructural evolution of single-phase compositionally complex alloy (CCA) compositions under dual-beam irradiation to their Mn-content via the stacking-fault energy (SFE) and vacancy migration energies. Two alloys, Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 , along with less compositionally complex pure Ni and Fe 56 Ni 44 binary were irradiated at 500 and 600 °C under dual-beam 1 MeV Kr 2+ and 16 keV He + heavy-ions up to 7 displacements per atom (dpa) with a He/dpa ratio of 0.75 %/dpa using in situ transmission electron microscopy (TEM). Due to the bubble-stabilizing effect of implanted He, bubbles were observed in all irradiations, and populations of faulted interstitial loops were characterized in Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 . A reduction in swelling was observed in the two CCAs compared to pure Ni and Fe 56 Ni 44 . Although swelling increased from 500 to 600 °C in Fe 56 Ni 44 , Cr 15 Fe 35 Mn 15 Ni 35 and Cr 18 Fe 27 Mn 27 Ni 28 both swelled slightly more at 500 °C. This was attributed to the difference in vacancy mobility, stronger pinning effect of vacancies on He, and the sink strength of faulted dislocation loops. Faulted interstitial loops nucleated with a higher number density and dislocation line density in Cr 15 Fe 35 Mn 15 Ni 35 at both temperatures, and at 600 °C in both materials. The differences in faulted loop population and temperature effect on swelling are correlated to the Mn-content and the measured SFE (20.2 ± 6.7 mJ/m 2 for Cr 18 Fe 27 Mn 27 Ni 28 and 9.2 ± 3.4 mJ/m 2 for Cr 15 Fe 35 Mn 15 Ni 35 ).

36 MATERIALS SCIENCE↗

Continental rift evolution and drainage reorganization along the Dead Sea rift since the Miocene

The Dead Sea fault is a section of the Arabian-African plate boundary. Widespread field relations indicate that three major drainage systems (stages) occupied the landscape west of the Dead Sea fault since its initiation at ca. 20 Ma. Specifically, (1) an early to middle Miocene drainage system, only minorly reconfigured by the fault (all sediments of this system belong to the Hazeva Formation); (2) a late Miocene to early Pleistocene fault-parallel drainage system named Paran-Neqarot (all sediments of this system belong to the Arava and Zehiha Formations; and (3) the early Pleistocene to present drainage configuration. The temporal and spatial frameworks of drainage stage 1 are generally constrained by radiometric dating of interfingering volcanic units, and the onset and temporal and spatial frameworks of drainage stage 3 are well constrained by cosmogenic 10 Be surface exposure ages. The timing and longevity of the rift-parallel drainage (stage 2) have until now been evasive to direct dating. The overall time gap between stages 1 and 3 is ~12–13 million years. Thus, an early age (within this time gap) of stage 2 would imply an immediate response of drainage reorganization to rift tectonics, while a later age of this drainage system would imply a delayed response. We present 11 10 Be- 26 Al cosmogenic burial ages of alluvial and colluvial units related to the fault-parallel drainage system (stage 2), which collectively constrain the time of deposition of the Arava Formation sediments in the central Negev to ca. 8 Ma. The general lack of stratigraphic order, together with the large dispersion of ages both across and within the sampling sites, attests to significant recycling of sediments from drainage stage 1 into the Arava Formation deposits. The termination of Arava and Zehiha Formation sediment deposition at ca. 1.8 Ma was determined previously using cosmogenic exposure ages of desert pavements that cover the formations. Combining the previously published data with our new data, we established the longevity and character of the Paran-Neqarot drainage system. In conlcusion, this framework highlights the temporal aspect of drainage system build-up and collapse as it responded to transform and extensional plate boundary tectonics during the Neogene.