Search NASA⌕ Search

SEARCH · Search NASA

Results for “information loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Detection of regional air pollution episodes utilizing satellite data in the visual range

A comparative analysis of satellite-observed haze patterns and ground-based aerosol measurements is carried out for July 20-23, 1978. During this period, a significant regional air pollution episode existed across the northeastern United States, accompanied by widespread haze, reduced surface visibility, and elevated sulfate levels measured by the Sulfate Regional Experiment (SURE) network. The results show that the satellite-observed haze patterns correlate closely with the area of reported low surface visibility (less than 4 mi) and high sulfate levels. Quantitative information on total aerosol loading derived from the satellite-digitized data, using an atmospheric radiative transfer model, agrees well with the results obtained from the ground-based measurements.

Bowley, C. J.↗

The boundary layer on compressor cascade blades

The flow field about an airfoil in a cascade at chord Reynolds number (R sub C) near 50,000. The program is experimental and combines laser Doppler anemometry (LDA) with flow visualization techniques in order to obtain detailed flow data (e.g., boundary layer profiles, points of separation and the transition zone) on a cascade of highly-loaded compressor blades. The information provided is to serve as benchmark data for the evaluation of current and future compressor cascade predictive models, in this way aiding in the compressor design process. The completed pressure surface mean velocity profiles, as well as two detailed near wake velocity profiles, all at a single incidence angle are provided.

Deutsch, S.↗

The boundary layer on compressor cascade blades

The purpose of NASA Research Grant NSG-3264 is to characterize the flowfield about an airfoil in a cascade at chord Reynolds number(R sub C)near 5 x 10 to the 5th power. The program is experimental and combines laser Doppler velocimeter (LDV) measurements with flow visualization techniques in order to obtain detailed flow data, e.g., boundary layer profiles, points of separation and the transition zone, on a cascade of highly-loaded compressor blades. The information provided by this study is to serve as benchmark data for the evaluation of current and future compressor cascade predictive models, in this way aiding in the compressor design process. Summarized is the research activity for the period 1 December 1985 through 1 June 1986. Progress made from 1 June 1979 through 1 December 1985 is presented. Detailed measurements have been completed at the initial cascade angle of 53 deg. (incidence angle 5 degrees). A three part study, based on that data, has been accepted as part of the 1986 Gas Turbine Conference and will be submitted for subsequent journal publication. Also presented are data for a second cascade angle of 45 deg (an incidence angle of 3 degrees).

Deutsch, S.↗

Power quality load management for large spacecraft electrical power systems

In December, 1986, a Center Director's Discretionary Fund (CDDF) proposal was granted to study power system control techniques in large space electrical power systems. Presented are the accomplishments in the area of power system control by power quality load management. In addition, information concerning the distortion problems in a 20 kHz ac power system is presented.

Lollar, Louis F.↗

Elevated temperature fracture of RS/PM aluminum alloy 8009

The fracture behavior of advanced powder metallurgy Al-Fe-V-Si alloy 8009 (previously called FVS0812) is being characterized under monotonic loads, as a function of temperature. Particular attention is focused on contributions to the fracture mechanism from the fine grained dispersoid strengthened microstructure, dissolved solute from rapid solidification, and the moist air environment. Time-dependent crack growth is characterized in advanced aluminum alloys at elevated temperatures with the fracture mechanics approach, and cracking mechanisms are examined with a metallurgical approach. Specific tasks were to obtain standard load crack growth experimental information from a refined testing system; to correlate crack growth kinetics with the j-integral and time dependent C(sub t)(t); and to investigate the intermediate temperature embrittlement of 8009 alloy in order to understand crack growth mechanisms.

Porr, William C., Jr.↗

A new scheme for multidimensional line transfer. II - ETLA method in one dimension with application to iron K-alpha lines

The 1D version of the radiation hydrodynamics computer code ALTAIR is discribed. It is an implementation of the equivalent two-level atom method, and also incorporates a variety of other iterative techniques to achieve a fast, accurate solution of the problem of coupled atomic kinetics and radiative transfer. All the techniques are described in sufficient detail to enable their use by others. The application of the program is illustrated by a set of calculations of the iron X-ray emission spectrum from intercloud hot gas that may exist in the broad-line region of active galactic nuclei. These calculations demonstrate that such spectra may be a rich load to mine for information about the hot gas in AGNs, and also that the concept of 'the iron K-alpha line' inadequately depicts the spectrum.

Castor, John I.↗

Effects of Range of Stress and of Special Notches on Fatigue Properties of Aluminum Alloys Suitable for Airplane Propellers

Laboratory tests were made to obtain information on the load-resisting properties of X76S-T aluminum alloy when subjected to static, impact, and repeated loads. Results are presented from static-load test of unnotched specimens in tension and in torsion and of notched specimens in tension. Charpy impact values obtained from bend tests on notched specimens and tension impact values for both notched and unnotched specimens tested at several different temperatures are included. The endurance limits obtained from repeated bending fatigue tests made on three different types of testing machine are given for unnotched polished specimens, and the endurance limits of notched specimens subjected to six different ranges of bending stress are also reported. The results indicated that: (a) polished rectangular specimens had an endurance limit about 30 percent less than that obtained for round specimens; (b) a comparison of endurance limits obtained from tests on three different types of machine indicated that there was no apparent effect of speed of testing on the endurance limit for the range of speeds used (1,750 to 13,000 rpm). (c) the fatigue strength (endurance limit) of the X76S-T alloy was greatly decreased by the presence of a notch in the specimens; (d) no complete fractures of the entire specimens occurred in notched fatigue specimens when subjected to stress cycles for which the mean stress at the notch during the cycle was a compressive stress; for this test condition a microscopic cracking occurred near the root of the notch and was used as a criterion of failure of the specimen. (e) as the mean stress at the notch was decreased from a tensile (+) stress to a compressive (-) stress, it was found that the alternating stress that could be superimposed on the mean stress in the cycle without causing failure of the specimens was increased.

ALUMINUM ALLOYS-ALCOA X76ST-FATIGUE↗

DSMC calculations for 70-deg blunted cone at 3.2 km/s in nitrogen

Numerical results obtained with the direct simulation Monte Carlo (DSMC) method are presented for Mach 15.6 nitrogen flow about a 70-deg spherically blunted cone at zero incidence. This flow condition is one of several generated in the Large Energy National Shock (LENS) tunnel during tests of a 15.24 cm diameter model with an afterbody sting. The freestream Knudsen number, based on model diameter, is 0.0023. The focus of the DSMC calculations is to characterize the near wake flow under conditions where rarefaction effects may influence afterbody aerothermal loads. This report provides information concerning computational details along with flowfield and surface quantities. Calculations show that the flow enveloping the test model is in thermal nonequilibrium and a sizable vortex develops in the near wake. Along the model baseplane the heating rates are about 0.6 percent of the forebody stagnation value while the maximum heating along the sting is about 4.2 percent of the forebody stagnation value. Comparison of a Navier-Stokes solution with the present calculations show good agreement for surface heating, pressure, and skin friction results.

Moss, J. N.↗

Transition Documentation on a Three-Element High-Lift Configuration at High Reynolds Numbers: Analysis

A 2-D high-lift system experiment was conducted in August of 1996 in the Low Turbulence Pressure Tunnel at NASA Langley Research Center, Hampton, VA. The purpose of the experiment was to obtain transition measurements on a three element high-lift system for CFD code validation studies. A transition database has been created using the data from this experiment. The present report contains the analysis of the surface hot film data in terms of the transition locations on the three elements. It also includes relevant information regarding the pressure loads and distributions and the wakes behind the model to aid in the interpretation of the transition data. For some of the configurations the current pressure data has been compared with previous wind tunnel entries of the same model. The methodology used to determine the regions of transitional flow is outlined and each configuration tested has been analyzed. A discussion of interference effects, repeatability, and three-dimensional effects on the data is included.

Bertelrud, Arild↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗

Fission Product Gas Monitoring During Fuel Drying Operations - 20094

The goal of the project was to devise and implement a method of accurately qualifying any noble gas emitted during fuel drying operations (part of the dry fuel storage process) in order to provide the data needed to validate the off-site dose calculations. The imputes of the project was the NRC publishing Information Notice 18-01, 'Noble Fission Gas Releases During Spent Fuel Cask Loading Operations' in February 2018. The information notice describes some industry events that occurred during vacuum drying operations as part of a dry fuel campaign. The solution was devised by Fort Calhoun Station staff in partnership with Mirion Technologies technical staff. The monitoring was accomplished by directing all the effluent from the fuel storage cask vacuum drying machine through a sample chamber containing a compact ISOCS characterized CZT based gamma spectrometer connected to a Mirion Data Analyst. This resulted near real-time quantification of the radionuclides of concern. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Pump and Treat Impacts on Aquifer Conditions and the Development of System-wide Performance Strategies - 19077

The 200 West pump-and-treat (P and T) system on the Hanford Site's Central Plateau currently treats multiple contaminants within the 200-ZP-1 Operable Unit (OU). Initially designed to support the 200-ZP1 Remedial Action Objectives, the use of the P and T system has evolved over time to address contaminants from other regions of the aquifer as well. The P and T system currently receives water from other regions within the Central Plateau that are biogeochemically distinct, treating groundwater with elevated concentrations of carbon tetrachloride, cyanide, uranium, technetium-99, and nitrate. Given the varying geochemical signatures from current and potential future sources, combined with the operational conditions and amendments used for treatment processes, there is a need to identify the impacts of the P and T system on the aquifer and aquifer impacts on P and T performance. To this end, initial laboratory analyses and geochemical modeling efforts focused on characterizing the baseline geochemical environment for the aquifer in the 200-ZP-1 OU. Several sediment characterization techniques, including geologic descriptions, water and acid extractions, and microbiological measurements were selected to determine key geochemical and microbiological constituents for the baseline, prior to injection of the effluent from the treatment plant. Different geochemical components within sediment samples from the aquifer were identified that may significantly affect how the sediments react to P and T injection water. Batch experiments were also used to identify aquifer impacts on operational performance and support development of some column studies. These experiments were designed to test and evaluate variable P and T effluents using actual effluent solutions from the treatment plant as well as simulated Hanford groundwater at different temperatures to identify the important geochemical and biological reactions that might occur within the aquifer. Initial results were used for geochemical modeling of the effluents and batch experiments. These results, along with the baseline data obtained from the initial sediment characterization, are intended to feed into the design of the column studies and inform conceptual models and modeling efforts for evaluating the fate and transport of introduced contaminants and co-injectates, and their short- and long-term impact on the aquifer-system injection capacity. This evaluation is designed to provide additional information on the major geochemical and microbiological reactions that are driven by the injection of the P and T effluent into the aquifer. Reactive transport modeling of the laboratory experiments and extrapolation to a larger-scale modeling domain provide information that can be used for predictive evaluations of system performance based on P and T operational changes and aquifer mass loading and capacity estimates. This information can be used to address combined subsurface and operational challenges, such as the need for frequent well redevelopment to maintain injection capacity. This information also provides the technical basis for decisions related to the P and T system operations that support remedy optimization efforts and short- and long-term remedy decisions related to multiple OUs on the Hanford Site Central Plateau. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scenarios for Consuming Standardized Automated Demand Response Signals

Automated Demand Response (DR) programs require that Utility/ISO's deliver DR signals to participants via a machine to machine communications channel. Typically these DR signals constitute business logic information (e.g. prices and reliability/shed levels) as opposed to commands to control specific loads in the facility. At some point in the chain from the Utility/ISO to the loads in a facility, the business level information sent by the Utility/ISO must be processed and used to execute a DR strategy for the facility. This paper explores the various scenarios and types of participants that may utilize DR signals from the Utility/ISO. Specifically it explores scenarios ranging from single end user facility, to third party facility managers and DR Aggregators. In each of these scenarios it is pointed out where the DR signal sent from the Utility/ISO is processed and turned into the specific load control commands that are part of a DR strategy for a facility. The information in these signals is discussed. In some cases the DR strategy will be completely embedded in the facility while in others it may be centralized at a third party (e.g. Aggregator) and part of an aggregated set of facilities. This paper also discusses the pros and cons of the various scenarios and discusses how the Utility/ISO can use an open standardized method (e.g. Open Automated Demand Response Communication Standards) for delivering DR signals that will promote interoperability and insure that the widest range of end user facilities can participate in DR programs regardless of which scenario they belong to.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microscopy and microstructure of Shuttle thermal protection system materials

Examples of the contribution of microstructural analysis to the development of the Space Shuttle tile insulation system are presented, with photographic examples of the scanning electron microscope (SEM) investigations. After the basic thermal protection system materials had been selected, it was neccessary to analyze the mechanical responses of the combined materials; which included: (1) the polymer strain isolation pad (SIP), (2) the room temperature-vulcanizing silicone rubber bond, (RTV), and (3) rigid ceramic fiber reusable surface insulation (RSI). Microstructural analysis was used to provide information on deformation and fracture mechanisms, load transfer mechanisms, and structural alterations occurring before final failure. Both quantitative and qualitative information was obtained in the open, three-dimensional fibrous structures of the ceramic tiles by means of novel techniques of encapsulation and dissolution.

Newquist, C. W.↗

Evidence for mass-loading of the Venus magnetosheath

The observed magnetic field configuration in the Venus magnetosheath contains information about the solar wind mass-loading processes occurring as a result of the extension of the neutral atmosphere into the magnetosheath. In this paper, magnetic field signatures of various mass-loading processes are discussed and experimental results from the Pioneer Venus Orbiter magnetometer experiment are examined for evidence of these signatures. The data suggest that the -V(bar)XB(bar) acceleration process, stochastic pickup of ionospheric ions, and J(bar)XB(bar) force 'scavenging' at the ionopause all occur at various times.

Luhmann, J. G.↗

Advanced Load Identification and Management for Buildings: Cooperative Research and Development Final Report

The goal of this CRADA work is to support Eaton Innovation Center (Eaton) efforts to develop advanced load identification, management technologies, and solutions to reduce building energy consumption by providing fine granular visibility of energy usage information and safety protection of miscellaneous electric loads (MELs) in commercial and residential buildings. MELs load identification and prediction technology will be employed in a novel "Smart eOutlet*" to provide critical intelligence and information to improve the capability and functionality of building load analysis and design tools and building power management systems. The work scoped in this CRADA involves the following activities: development and validation of business value proposition for the proposed technologies through voice of customer investigation, market analysis, and third-party objective assessment; development and validation of energy saving impact as well as assessment of environmental and economic benefits; "smart eOutlet" concept design, prototyping, and validation; field validation of the developed technologies in real building environments. (*Another name denoted as "Smart Power Strip (SPS)" will be used as an alternative of the name "Smart eOutlet" for a clearer definition of the product market position in future work.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Workplace Charge Management with Aggregated Building Loads

This paper describes a workplace charge management system developed to control plug-in electric vehicle charging stations based on aggregated building loads. A system to collect information from drivers was also developed for better charge management performance since the present AC charging station standard does not provide battery state of charge information. First, simulations with uncontrolled charging data were conducted to investigate several scenarios and control methods, and then one method with the most power curtailment during peak load was selected for verification tests. This paper illustrates load reduction test results for 36 charging stations and real-time campus net load data.

25 ENERGY STORAGE↗