Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid jets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Fluid spray simulation with two-fluid nozzles

Two-phase interacting flow inside a two-fluid fuel atomizer was investigated and a correction of aerodynamic and liquid-surface forces with characteristic drop diameter was obtained for liquid-jet breakup in Mach 1 gas flow. Nitrogen gas mass-flux was varied from 6 to 50 g/sq cm sec by using four differently sized two-fluid atomizers with nozzle diameters varyig from 0.32 to 0.56 cm. The correlation was derived by using the acoustic gas velocity, V sub c, as a basic parameter in defining and evaluating the dimensionless product of the Weber (We) and Reynolds (Re) numbers. By using the definition of WeRe, it was found that the ratio of orifice diameter to Sauter mean drop diameter could be correlated with the dimensionless ratio WeRe and the gas to liquid density ratio.

Ingebo, Robert D.↗

Fuel spray simulation with two-fluid nozzles

Two-phase interacting flow inside a two-fluid fuel atomizer was investigated and a correction of aerodynamic and liquid-surface forces with characteristic drop diameter was obtained for liquid-jet breakup in Mach 1 gas flow. Nitrogen gas mass-flux was varied from 6 to 50 g/sq cm sec by using four differently sized two-fluid atomizers with nozzle diameters varying from 0.32 to 0.56 cm. The correlation was derived by using the acoustic gas velocity, V sub c, as a basic parameter in defining and evaluating the dimensionless product of the Weber (We) and Reynolds (Re) numbers. By using the definition of WeRe, it was found that the ratio of orifice diameter to Sauter mean drop diameter could be correlated with the dimensionless ratio WeRe and the gas to liquid density ratio.

Ingebo, Robert D.↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sequence2Self: Self-supervised image sequence denoising of pixel-level spray breakup morphology

Optical imaging of fast and transient phenomena such as the turbulent breakup of liquid sprays exhibit low signal-to-noise ratios due to the limited illumination intensity relative to the short exposure time. Image denoising is required to facilitate physical studies over these data but is challenging due to the absence of clean ground-truths and the stringency of the denoising task (e.g., strong and complex noise, limited resolution, preserving physical fidelity), preventing supervised and existing un-/self-supervised deep learning methods. To this end, Sequence2Self (Seq2S) is proposed, an extension of Self2Self (S2S) to image sequences that leverages both the signal’s spatial and temporal correlation. Seq2S is demonstrated on time-resolved x-ray phase contrast imaging of liquid jet fuel sprays in a gas turbine combustor, which possesses all of challenges detailed above. Experiments are conducted across four fuels with different breakup morphology using various state-of-the-art methods. Overall, many of the methods failed and Seq2S was most successful: (1) Accurate spray structures were reconstructed with consistent evolution across frames void of artifacts. (2) The performance was robust, invariant to the hyperparameter choice. (3) Computational time is short and can be made eligible for real-time denoising. In particular, the images denoised by Seq2S showed spray droplet diameter distributions with near-zero Kullback–Leibler divergence (0.01 ± 0.01) to a cleaner reference, whereas the second best method yielded 0.06 ± 0.03. In conclusion, this suggests that Seq2S can be reliably used prior to subsequent quantitative spray analyses as it retains (if not, improves) the statistical physical properties of the data.

97 MATHEMATICS AND COMPUTING↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

A self-referenced in-situ arrival time monitor for X-ray free-electron lasers

We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the supercontinuum pulses are temporally overlapped to yield near-perfect destructive interference in the absence of the X-ray pulse. Stimulation of the sample with an X-ray pulse delivers non-zero contributions at certain optical wavelengths, which serve as a measure of the relative arrival time of the X-ray pulse with an accuracy of better than 25 fs. We find an excellent agreement of our monitor with the existing timing diagnostics at the SACLA XFEL with a Pearson correlation value of 0.98. We demonstrate a high sensitivity to measure X-ray pulses with pulse energies as low as 30 μJ. Using a free-flowing liquid jet as interaction sample ensures the full replacement of the sample volume for each X-ray/optical event, thus enabling its utility even at MHz repetition rate XFEL sources.

47 OTHER INSTRUMENTATION↗

Advanced manufacturing provides tailor-made solutions for crystallography with x-ray free-electron lasers

Serial crystallography at large facilities, such as x-ray free-electron lasers and synchrotrons, evolved as a powerful method for the high-resolution structural investigation of proteins that are critical for human health, thus advancing drug discovery and novel therapies. However, a critical barrier to successful serial crystallography experiments lies in the efficient handling of the protein microcrystals and solutions at microscales. Microfluidics are the obvious approach for any high-throughput, nano-to-microliter sample handling, that also requires design flexibility and rapid prototyping to deal with the variable shapes, sizes, and density of crystals. Here, we discuss recent advances in polymer 3D printing for microfluidics-based serial crystallography research and present a demonstration of emerging, large-scale, nano-3D printing approaches leading into the future of 3D sample environment and delivery device fabrication from liquid jet gas-dynamic virtual nozzles devices to fixed-target sample environment technology.

36 MATERIALS SCIENCE↗

Nonuniform Flow Dynamics Probed by Nanosecond X-Ray Speckle Visibility Spectroscopy

We report observations of nanosecond nonuniform colloidal dynamics in a free flowing liquid jet using ultrafast x-ray speckle visibility spectroscopy. Utilizing a nanosecond double-bunch mode, the Linac Coherent Light Source free electron laser produced pairs of femtosecond coherent hard x-ray pulses. By exploring anisotropy in the visibility of summed speckle patterns which relates to the correlation functions, we evaluate not only the average particle flow rate in a colloidal nanoparticle jet, but also the nonuniform flow field within. The methodology presented here establishes the foundation for the study of nano- and atomic-scale inhomogeneous fluctuations in complex matter using x-ray free electron laser sources.

47 OTHER INSTRUMENTATION↗

Fragmentation of faceted crystalline wires

The reduction of surface energy is a well-known driving force for the fragmentation of nanowires. Fragmentation can limit the service life of those small low-dimensional building blocks or can be controlled to induce beneficial shape changes. For isotropic surface energy, fragmentation is analogous to the classic Rayleigh-Plateau instability of liquid jets. However, commonly synthesized crystalline nanowires have strongly anisotropic surface energies and exhibit facets coinciding with cusps in the Wulff plot. Depending on growth orientation, different fragmentation behaviors have been seen in nanowires. Using phase-field simulations, we show that fragmentation of faceted nanowires with cubic crystal symmetry may occur by a finite-amplitude nonlinear instability, as opposed to a Rayleigh-Plateau-like linear instability, depending on nanowire growth orientation. Here, we carry out a weakly nonlinear analysis based on sharp interface theory to characterize the faceted nanowire shape corresponding to a surface-energy saddle point. The analysis predicts that the minimum amplitude of a periodic shape perturbation to trigger fragmentation increases with cusp strength but decreases inversely proportionally to the perturbation wavelength for long wavelengths, in good quantitative agreement with phase-field predictions. The results provide the theoretical foundation to predict nanowire stability as a function of length and surface energy in diverse applications.

36 MATERIALS SCIENCE↗

Speed of sound in methane under conditions of planetary interiors

We present direct observations of acoustic waves in warm dense matter. We analyze wave-number- and energy-resolved x-ray spectra taken from warm dense methane created by laser heating a cryogenic liquid jet. X-ray diffraction and inelastic free-electron scattering yield sample conditions of 0.3 ± 0.1 eV and 0.8 ± 0.1 g/ cm − 3 , corresponding to a pressure of ∼ 13 GPa. Inelastic x-ray scattering was used to observe the collective oscillations of the ions. With a highly improved energy resolution of ∼ 50 meV, we could clearly distinguish the Brillouin peaks from the quasielastic Rayleigh feature. Data at different wave numbers were utilized to derive a sound speed of 5.9 ± 0.5 km/s, marking a high-temperature data point for methane and demonstrating consistency with Birch's law in this parameter regime. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ePix10k 2-megapixel hard X-ray detector at LCLS

The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel −1 pulse −1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray Pump-Probe Measurements using a Laser-Plasma Accelerator (Final Report)

This project funded one graduate student, Mario Balcazar, to perform experiments on high power laser facilities to study the application of X-rays generated by laser wakefield accelerated electrons for advanced radiography, in particular X-ray phase contrast imaging of hydrodynamic shocks/instabilities. The work made use of the DOE’s LaserNetUS facilities. We performed dynamic phase-contrast X-ray imaging of the shock generated by a 200 ps duration laser pulse (E = 1 J, I = 10 15 Wcm –2 ) with a 30 µm diameter liquid target, with unprecedented spatio-temporal resolution. This includes multi-shock generation within the liquid jet and plasma instability formation. Innovative electron-beam radiography was used to probe the laser-plasma interplay finding evidence of bilateral heating of the water followed by strong electric field generation. These measurements help explain some of the discrepancies between simulation and experiment and pave the way to better plasma diagnostic systems in HED and ICF physics experiments. This work was performed in collaboration with researchers from Michigan, LLNL, LBL and Sandia National Laboratories, Queen’s University Belfast and Imperial College.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlled droplet spray generator

Spray generator produces streams of uniform-size droplets issuing at uniform rate by applying an oscillatory disturbance to free liquid jets. Jets of varying diameters can be grouped together and oscillated as a group to produce simultaneous streams of uniform-size droplets.

Nicholls, J. A.↗