Search NASA⌕ Search

SEARCH · Search NASA

Results for “municipal use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

An AI-driven framework for evaluating local and state authorities’ permitting processes

The demand for new energy infrastructure is increasing across the United States, but heterogenous permitting processes and embedded requirements across different local jurisdictions can cause project delays, increase “soft costs,” and hinder developer expansion. This study analyzes the variability in local permitting requirements across the U.S. and develops a quantitative approach to describe their clarity and effectiveness in enabling infrastructure project development. By using an Energy Language Model (ELM), a large language model (LLM) for energy technologies, we systematically gathered permitting information from nearly 300 state-, county-, and city-level documents, creating a structured dataset of requirements and procedures on an unprecedented scale and speed. Our analysis revealed that local (city and county) permitting requirement documents are underrepresented compared to state-level guidance documents, which can impede timely and cost-effective installation of new electric infrastructure. Our validation process showed that the final database has an accuracy of approximately 95%. We, further, created a new quantitative method to score permitting requirements for clarity and efficiency, with electric vehicle supply equipment as an initial use case. The average local permitting document scored a 1.8 out of 5, which we interpret as meaning that half of the requirements developers face when installing electric infrastructure are ambiguous, increasing both cost and time. We also created a “Generalized Permit Process”, highlighting common procedural steps and identifying specific opportunities for municipalities to improve their documentation. This research establishes a systematic and scalable framework for evaluating the complexities of local infrastructure permitting processes by combining LLM-powered data collection and quantitative scoring. The framework enables policymakers and developers to identify and mitigate procedural bottlenecks, with the expectation that these improvements can accelerate application review and approval, reduce project costs, and expedite connection to utility distribution grids. As a foundational approach for streamlining local project development processes, this study’s methods are intended to be extended to a wide range of energy applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Alternating, Current-Induced Electromagnetic Field for Membrane Fouling and Scaling Control during Desalination of Secondary Effluent from Municipal Wastewater

Membrane treatment of secondary effluent for reuse applications is a promising approach to expand water supplies and provide flexibility to water resources management. However, effective control of membrane fouling and scaling is crucial for cost-effective treatment and system resilience. This study compared the performance of antiscalants to an alternating, current-induced electromagnetic field (EMF) as an alternative pretreatment method to reverse osmosis. Compared to the no-EMF control experiments, the EMF device resulted in 13% higher water recovery and 366% lower flux decline at 60% of water recovery, along with 2–8 times lower precipitation of fouling and scaling, as evidenced by scanning electron microscope, energy dispersive X-ray spectroscopy, and chemical extraction analysis. The combination of the EMF with antiscalant was more effective for reducing membrane fouling and scaling, increasing water recoveries up to 89.3%, as compared to the EMF (67.5%) and antiscalant-only (73.6%) configurations. This is the first study to demonstrate synergistic effects of using an EMF in combination with antiscalants and could lead to lower pretreatment costs. Additional research is required to quantify the economics of this approach and to fully understand the fundamental mechanisms governing fouling and scaling control by an EMF.

42 ENGINEERING↗

Use of MODIS Terra Imagery to Estimate Surface Water Quality Standards, Using Lake Thonotosassa, Florida, as a Case Study

Lake Thonotosassa is a highly eutrophied lake located in an area with rapidly growing population in the Tampa Bay watershed, Florida. The Florida Administrative Code has designated its use for "recreation, propagation and maintenance of a healthy, well-balanced population of fish and wildlife." Although this lake has been the subject of efforts to improve water quality since 1970, overall water quality has remained below the acceptable state standards, and has a high concentration of nutrients. This condition is of great concern to public health since it has favored episodic blooms of Cyanobacteria. Some Cyanobacterial species release toxins that can reach humans through drinking water, fish consumption, and direct contact with contaminated water. The lake has been historically popular for fishing and water sports, and its overflow water drains into the Hillsborough River, the main supply of municipal water for the City of Tampa, this explains why it has being constantly monitored in situ for water quality by the Environmental Protection Commission of Hillsborough County (EPC). Advances in remote sensing technology, however, open the possibility of facilitating similar types of monitoring in this and similar lakes, further contributing to the implementation of surveillance systems that would benefit not just public health, but also tourism and ecosystems. Although traditional application of this technology to water quality has been focused on much larger coastal water bodies like bays and estuaries, this study evaluates the feasibility of its application on a 46.6 km2 freshwater lake. Using surface reflectance products from Moderate-Resolution Imaging Spectroradiometer (MODIS) Terra, this study evaluates associations between remotely sensed data and in situ data from the EPC. The parameters analyzed are the surface water quality standards used by the State of Florida and general indicators of trophic status.

Moreno, Max J.↗

Techno-economic analysis of bioplastic and biofuel production from a high-ash microalgae biofilm cultivated in effluent from a municipal anaerobic digester

Rotating Algae Biofilm Reactors (RABRs) are a promising technology for efficient treatment of wastewater and production of algae-based bioproducts. However, RABR-grown algae can contain a high content of ash (30–60 wt%, dry basis), which influences the technical and economic feasibility of bioproduct conversion processes. In this report, experimental studies and economic analysis were conducted to compare different processes for bioproduct conversion of a high-ash microalgae biofilm grown using a RABR treating 0.6 million gallons per day of anaerobic digestion centrate at the Central Valley Water Reclamation Facility in Salt Lake City, UT. Process and economic models were developed and compared for three conversion processes: 1) the production of bioplastics, 2) the production of bioplastics with a lipid-extraction pretreatment, and 3) the production of biocrude via hydrothermal liquefaction. Techno-economic analysis was performed for each conversion process, including three cases for algae productivity: 231, 391, and 577 metric tons per year (dry basis). The calculated value for the minimum plastic selling price (MPSP) of bioplastics produced from algae ranges from $\$4050$ to $\$3520$ per metric ton based on the baseline and final productivity cases of the RABR, respectively. The extraction of lipids in addition to bioplastic production results in an MPSP of $\$4570$ to $\$4000$ per metric ton for the same productivity cases. The relatively small production scale and complex processing for hydrothermal liquefaction results in a minimum fuel selling price of the biocrude of $\$5.32$ per gallon of gasoline equivalent. In conclusion, the conversion process for bioplastic production from whole algae has the highest income:expense ratio and the most cost-competitive pricing of the three modeled processes.

09 BIOMASS FUELS↗

Automated pilot advisory system test and evaluation at Manassas Municipal Airport

In cooperation with the Federal Aviation Administration, NASA developed an experimental automated pilot advisory system (APAS) to provide airport and air traffic advisories at high density uncontrolled airports. The APAS concept is to utilize low cost automated systems to provide the necessary information for pilots to more safely plan and execute approach and landing at uncontrolled high density airports. The system is designed to be a natural extension of the procedural visual flight rules system used at uncontrolled airports and, as an advisory system, will enhance the "see-and-be-seen" rule and an evaluation of the APAS concept was obtained from pilots who used the system at the Manassas, Virginia airport. These evaluations and the system performance are presented.

Parks, J. L., Jr.↗

Development of a Liquid Bridge Model for Particle Agglomeration and Defluidization in Plastic Pyrolysis

Molten plastic that forms during the pyrolysis of plastic or municipal solid waste feedstock can lead to particle agglomeration. A liquid bridge model is developed in MFiX-DEM and validated against a cold flow experiment with glass beads coated with silicone oil. The liquid bridge model is then extended to support an evolving liquid layer thickness for pyrolysis applications. The extended model is used to study the sensitivity of the pyrolysis reactor to solids holdup, flow conditions, and plastic properties.

Banerjee, Subhodeep↗

Mineral-hydrogel composites for mitigating harmful algal bloom and supplying phosphorous for photo-biorefineries

Harmful algal blooms (HAB) are a major environmental concern in eutrophic aquatic systems. To mitigate HABs and recover the phosphorus that drives algal growth, this study developed hydrogel composites seeded with calcium phosphate and wollastonite particles, which first adsorb phosphate (P) and then precipitate it as calcium phosphate. Using a fast-growing cyanobacterium, Synechococcus elongatus 2973, as a model microalga, we found that the mineral-hydrogel composites reduced dissolved P in BG11 media from 5.1 mg/L to 0.31 mg/L, initially reducing the biomass growth rate by up to 73 % and ultimately reducing the total biomass concentration by 75 %. When applied to municipal wastewater and agricultural run-off, the composites removed 96 % and 91 % of the dissolved P, respectively. Moreover, when the recovered P-enriched composites were reused as a slow-release bio-compatible fertilizer in a photobioreactor, they effectively supported algal growth without blocking light and interfering with photosynthesis. The P-enriched composites could tune the P concentration in the culture medium and significantly promote algal lipid accumulation. Finally, this study demonstrates the mineral-hydrogel composites' potential to treat point sources of P pollution and subsequently facilitate photoautotrophic biofuel production as a nutrient, effectively recycling the captured P.

59 BASIC BIOLOGICAL SCIENCES↗

Electrocoagulation in Water Treatment: Targeted Contaminant Removal and Laboratory Best Practices

Electrocoagulation for water treatment offers many advantages over traditional treatment technologies, including improved energy efficiency and modularity. One challenge with electrocoagulation is the lack of standardization in the methodology and reporting. This review provides a novel contribution by examining the past literature using a uniform metric (charge loading) as a basis for comparison, highlighting the importance of uniform reporting practices in this field. Furthermore, this review provides practical guidance for experimentalists in standardizing the electrocoagulation design and operating procedures. First, we present a comprehensive overview of contaminant-specific electrocoagulation as an electrochemical treatment technology for processing industrial, municipal, and agricultural water, with a focus on aluminum and iron electrocoagulation. We detail the fundamental mechanisms that allow for constituent removal during pretreatment. Specifically, we highlight electrocoagulation’s potential for organics, metalloids, microbes, and hardness remediation, examining the optimal removal conditions in terms of charge loading and current density. We conclude this work with some experimental best practices for lab-scale electrocoagulation experiments.

aluminum↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Data-driven modeling of municipal water system responses to hydroclimate extremes

Sustainable western US municipal water system (MWS) management depends on quantifying the impacts of supply and demand dynamics on system infrastructure reliability and vulnerability. Systems modeling can replicate the interactions but extensive parameterization, high complexity, and long development cycles present barriers to widespread adoption. To address these challenges, we develop the Machine Learning Water Systems Model (ML-WSM) – a novel application of data-driven modeling for MWS management. We apply the ML-WSM framework to the Salt Lake City, Utah water system, where we benchmark prediction performance on the seasonal response of reservoir levels, groundwater withdrawal, and imported water requests to climate anomalies at a daily resolution against an existing systems model. The ML-WSM accurately predicts the seasonal dynamics of all components; especially during supply-limiting conditions (KGE > 0.88, PBias < ±3%). Extreme wet conditions challenged model skill but the ML-WSM communicated the appropriate seasonal trends and relationships to component thresholds (e.g., reservoir dead pool). The model correctly classified nearly all instances of vulnerability (83%) and peak severity (100%), encouraging its use as a guidance tool that complements systems models for evaluating the influences of climate on MWS performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reducing Pb and Cl Mobility in Waste-to-Energy Fly Ashes via Chlorellestadite Formation

Sustainably sourced development minerals are vital to meeting the demand for low-carbon construction materials. A potential waste material that can be a low-carbon construction material for cementitious systems is waste-to-energy fly ash (WTE ash), a by-product of waste incineration. WTE ash contains chloride-bearing species and heavy metals, which can promote steel reinforcement corrosion and present long-term leaching risks. Here, we present a new multi-step ash treatment protocol involving dissolution and heating to transform the non-readily removable chlorides in WTE ash to Chlorellestadite (Ca 10 (SiO 4 ) 3 (SO 4 ) 3 Cl 2 ). Our results suggest that this transformation significantly reduces chloride release from WTE ash in an alkaline cement-like environment by over two orders of magnitude, from 1500 mg/l to less than 10 mg/l. This transformation also significantly reduces Pb mobility after treatment (from > 5 mg/l to < 0.5 mg/l), likely caused by the crystallo-chemical incorporation of Pb in Chlorellestadite. In contrast to the existing ash treatment methods, the proposed ash treatment protocol minimizes heavy metals volatilization while simultaneously reducing Pb mobility and chloride release through Chlorellestadite formation. Furthermore, these findings overcome limitations preventing the commercial use of WTE ash and thus opening up pathways towards a circular economy.

36 MATERIALS SCIENCE↗

Optimal Operation of PV Sources in DC Grids for Improving Technical, Economical, and Environmental Conditions by Using Vortex Search Algorithm and a Matrix Hourly Power Flow

This document presents a master–slave methodology for solving the problem of optimal operation of photovoltaic (PV) distributed generators (DGs) in direct current (DC) networks. This problem was modeled using a nonlinear programming model (NLP) that considers the minimization of three different objective functions in a daily operation of the system. The first one corresponds to the minimization of the total operational cost of the system, including the energy purchasing cost to the conventional generators and maintenance costs of the PV sources; the second objective function corresponds to the reduction of the energy losses associated with the transport of energy in the network, and the third objective function is related to the minimization of the total emissions of CO2 by the conventional generators installed on the DC grid. The minimization of these objective functions is achieved by using a master–slave optimization approach through the application of the Vortex Search algorithm combined with a matrix hourly power flow. To evaluate the effectiveness and robustness of the proposed approach, two test scenarios were used, which correspond to a grid-connected and a standalone network located in two different regions of Colombia. The grid-connected system emulates the behavior of the solar resource and power demand of the city of Medellín-Antioquia, and the standalone network corresponds to an adaptation of the generation and demand curves for the municipality of Capurganá-Choco. A numerical comparison was performed with four optimization methodologies reported in the literature: particle swarm optimization, multiverse optimizer, crow search algorithm, and salp swarm algorithm. The results obtained demonstrate that the proposed optimization approach achieved excellent solutions in terms of response quality, repeatability, and processing times.

14 SOLAR ENERGY↗

Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

Source record↗

The Application of Remote Sensing and Machine Learning to Improve Early Warning Systems for Harmful Algal Events in the Highland Lake Chain, TX

Beginning in 2019, harmful algal events have caused canine deaths in both Lady Bird Lake and Lake Travis located near Austin, Texas. These two reservoirs are part of the larger Highland Lakes chain, managed by the City of Austin Department of Watershed Protection (COA DWP) and the Lower Colorado River Authority (LCRA), which fulfill municipal, commercial, and agricultural water demands. Given the recent increase in favorable environmental conditions for algal events in central Texas, NASA DEVELOP partnered with LCRA and COA DWP to improve monitoring and early detection of algal events, utilizing satellite remote sensing and machine learning. Spatially and temporally varied chlorophyll a concentrations, cyanobacteria detections, turbidity, and water surface temperature products are used as environmental proxies. Landsat 8 Operational Land Imager (OLI) and the Sentinel-2 MultiSpectral Instrument (MSI) data were used to provide a combined revisit time of up to ~3 days and < 30 m per pixel products. Chlorophyll a concentrations were estimated using a pre-trained Mixture Density Network, and cyanobacteria detection was accomplished using the Broad Wavelength Algae Index, which can differentiate algal blooms from algal proliferations (mats). In situ data were used to validate remotely sensed measurements and quantify uncertainties. Preliminary results show a good fit between the modeled output and in situ observations, suggesting that remote sensing data can be used to retrieve biogeochemical properties and/or inherent optical properties (IOPs) of water columns in these inland human-made lakes. Uncertainties were introduced from the sensitivity to atmospheric correction, inherent mismatch between satellite and sampling data, and a relatively lower signal-to-noise ratio over water. The resulting products enable near real-time monitoring of environmental proxies relevant to algal event presence in the Highland Lakes chain, and will ultimately support water management, decision making, and risk communication.

Shuyu Chang↗

City and County Vehicle Inventories

This light-duty vehicle inventory dataset provides information on vehicle registrations by vehicle type (car vs. truck), fuel type, and model year showing the changes in adoption trends over time and average fuel economies. This data is part of a suite of state and local energy profile data available at the "State and Local Energy Profile Data Suite" link below and builds on Cities-LEAP energy modeling, available at the "EERE Cities-LEAP Page" link below. Examples of how to use the data to inform energy planning can be found at the "Example Uses" link below.

Alternative Fuel↗

Waste management strategies for military-generated waste in the United States

Sustainable and energy efficient municipal solid waste (MSW) management is vital for the health and performance of deployed soldiers, as they play an important role in the safety and dignity of a country. As the United States targets net-zero carbon-free emission goals, research and development are essential to surpassing current practices for management of MSW at military installations, both at home and abroad. To achieve this, it is important to act upon and implement the policies and instructions set by government agencies such as the Environmental Protection Agency (EPA), the Department of Energy (DOE), and the Department of Defense (DoD). Understanding the composition of waste and disposal methods that are in use at military installations is a crucial step to success. Here, the authors show this through analyzed data from trusted sources, such as government agencies, reports, magazines, journals, and other publications on MSW management techniques. By defining these challenges, possible solutions can be better understood for improved management of MSW at military installations in the United States. Finally, an integrated approach with deployable units capable of waste-to-energy technology using waste reduction, diversion, and recycling strategies shows to be an effective pathway for MSW conversion into energy and other useful products.

09 BIOMASS FUELS↗

Preprocessing of municipal solid waste towards thermal insulating material

Municipal solid waste (MSW) is one of the significant challenges in today’s world. A continuous surge in population, increasing living standards, and rapid urbanization are generating an enormous quantity of MSW. For example, the Environmental Protection Agency (EPA) reported that the total generation of MSW in the United States in 2018 was 292.4 million tons. Improper management of this MSW often leads to the release of greenhouse gases, emission of particulate matters, and formation of dioxins, which all ultimately contributes to climate change. Recycling these wastes via landfills with gas recovery and/or energy and material production via thermal and chemical conversions could be viable options to manage these challenges. Depending on the inherent chemical and structural properties of unrecycled wastes, the carbon structures can be tailored for processing and reuse in manufacturing of structural composites, building materials such as insulation, carbon dense reactant materials such as activated carbon, and so on. According to the EPA’s estimation, MSW in the United States is approximately 23% paper and paperboard, 12% plastics, 6% wood and 6% is textiles. Thus, this research focused on the feasibility of using the MSW as insulation material for the construction sector. The goal of this work was to determine the range of particle sizes, consolidation ratios, and component blends that can achieve insulation R-values within at least 70% that of traditional blown cellulose fiber. To achieve this goal, we designed the testing matrix based on five different component blends, three different particle sizes, and three different compaction level. An American Society for Testing and Materials (ASTM) method (C-739) was used to measure the R-value of the insulation material. Results showed that, adding more paper component in addition to smaller particle size and loose compaction made the insulation similar to the traditional blown cellulose fiber insulation as the R-value was within a range of 2.5-3.0 per inch.

42 ENGINEERING↗

Electrochemically recovered struvite matches conventional fertilizers in soil nutrient supply

Phosphorus (P) is an essential macronutrient for agriculture, yet global reliance on finite phosphorite reserves raises concerns about long-term food and nutrient security. Struvite (MgNH 4 PO 4 ·6H 2 O), a mineral recovered from municipal wastewater, represents a sustainable and circular source of P, but uncertainty remains regarding its nutrient availability relative to conventional fertilizers. This study evaluated the fertilizer value and environmental safety of electrochemically recovered struvite (RecoP) in comparison with diammonium phosphate (DAP), triple superphosphate (TSP), and rock phosphate (RockP). Nutrient availability, potential contaminant concentrations, and soil P and nitrogen (N) dynamics were assessed using standardized chemical analyses and an 8-week incubation experiment across three soils with contrasting soil types. RecoP contained 14.7% citrate-soluble P, significantly greater than RockP and comparable to DAP and TSP. Across all soils, RecoP increased both readily available and moderately labile P pools (p < 0.01), matching the performance of conventional fast-release fertilizers. Despite containing approximately half the total of DAP, RecoP stimulated nitrification rates that were 2.2 times greater than the control and exceeded those of TSP, suggesting that fertilizer-derived N bioavailability, rather than total N loading, governed microbial N transformation responses. Concentrations of potentially toxic elements in RecoP were consistently well below US Environmental Protection Agency regulatory limits thresholds. Collectively, these results indicate that RecoP functions as a readily available source of both P and N, comparable to widely used conventional fertilizers, while meeting environmental safety standards. RecoP therefore represents a viable component of sustainable nutrient management strategies that support P recycling and agricultural productivity.

Kharal, Sudarshan [Ohio Univ., Athens, OH (United ↗