Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background

Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300–1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10{sup −5}M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced laser absorption from radiation pressure in intense laser plasma interactions

The reflectivity of a short-pulse laser at intensities of 2 x 10 21 Wcm -2 with ultra-high contrast (10 -15 ) on sub-micrometer silicon nitride foilswas studied experimentally using varying polarizations and target thicknesses. Furthermore, the reflected intensity and beam quality were found to be relatively constant with respect to intensity for bulk targets. For submicron targets, the measured reflectivity drops substantially without a corresponding increase in transmission, indicating increased conversion of fundamental to other wavelengths and particle heating. The experimental results and trends we observed in 3D particle-in-cell simulations emphasize the critical role of ion motion due to radiation pressure on the absorption process. Ion motion during ultra-short pulses enhances the electron heating, which subsequently transfers more energy to the ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-D-18C-01: Art of Imaging: Diagnostic Ultrasound Image Artifacts

Assumptions followed during construction of B-mode and color flow images are that the pulse-echo transit time can be converted to reflector depth through uniform tissue models, echoes originate only from locations along the transmit-receive axes of pulse propagation, and first order correction schemes adequately account for acoustic wave attenuation and absorption. The latter allows the display brightness to encode tissue echogenicity. This course will challenge participants to identify imaging artifacts whose origins stem from the more complex and realistic propagating and scattering conditions common in clinical ultrasound. Speckle, a very common artifact but a clinically employed feature, originates from simultaneous echoes from diffuse scatterers and is a result of coherent detection of signals. One of the most bothersome artifacts are those due to reverberations especially that originating from superficial tissue interfaces. Methods to overcome these will be discussed. This presentation also will describe and illustrate speed of sound, refraction, enhancement, shadowing, mirroring, beam width, beam-forming, and slice thickness artifacts. All are useful examples of limitations introduced by acoustic waves propagating through complex tissue paths. New formats for physician board certification exams are demanding the inclusion of image-based examples of ultrasound physics. Instructors' knowledge of, and access to examples of ultrasound artifacts are important in this effort. The presentation will incorporate an audience response system to challenge participants in correct identification of some of these artifacts. Learning Objectives: Review basic mechanisms for producing ultrasound images. Identify the etiology of speckle, reverberation noise, beam width and slice thickness artifacts, and artifacts associated with pulse propagation. Discuss methods that reduce the impact of artifacts OR employ artifacts effectively to facilitate clinical diagnosis.

60 APPLIED LIFE SCIENCES↗

Development of processing algorithms to enable high-rate microcalorimeter array operation

The millisecond-scale decay constants of microcalorimeter gamma-ray pulses present challenges for operation at high count rates needed to compete with semiconductor HPGe detectors. If using conventional optimal filtering methods, pulse records with pileup events are simply discarded, leading to a large fraction of data unused when count rates are large. For single pixel rates exceeding 1-2 Hz, improved pulse processing algorithms are needed to better deal with pileup and increase the filter throughput. A 256-pixel array operating at 10 Hz per pixel would provide a total counting rate of 2.5 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled Multimodal Dynamics of Hydrogen-Containing Ion Networks in Water-Deficient, Sodium Hydroxide-Aluminate Solutions

The (meta)stability of low water activity sodium hydroxide/aluminate (Na + OH–/Al(OH) 4 –) electrolytes dictates kinetics in the Bayer process for aluminum refining and high-level nuclear waste processing. We utilized quasi-elastic neutron scattering (QENS) and proton nuclear magnetic resonance spectroscopy ( 1 H NMR) in extremely concentrated sodium aluminate solutions to investigate the picosecond (ps) to microsecond (ms) timescale motions of H-bearing species (Al(OH) 4 – monomers/clusters, OH– and H 2 O). In the QENS data, in contrast to typical liquids, no short-time translational diffusion was observed at 293 K, but two types of localized motions were found: (i) local backbone tumbling or a formation of large hydrated ion clusters on the order of 40–60 ps; and (ii) much slower, complex, and collective dynamics of the ensemble of H-bearing species on the order of 350–750 ps. Variable temperature, pulsed field gradient, diffusion-ordered 1H NMR was used to determine the ensemble translational motion along with relaxometry to calculate rotational correlation coefficients. The ensemble rotational correlation times were on the order of 184–300 ps from 1 H NMR, which is consistent with the timescale of the QENS components. Complementary molecular dynamics simulation of NaOH solutions exhibit extensive ion networks potentially responsible for the observed dynamical coupling of water with the motion of large hydrated ion clusters. Understanding these collective motions will aid in predicting the behavior of complex solutions during aluminum production and during nuclear waste processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Implementation of the thermonuclear process in D{sup 3}He-{sup 9}Be plasma on the basis of a Z pinch with an ultrafast laser ignition

A new concept of inertial-magnetic confinement fusion is proposed. This concept is based on a high-current Z pinch combined with a femtosecond laser. The fusion target is composed of a D{sup 3}He fuel contained under a high pressure inside a sealed cylindrical capsule made from metallic {sup 9}Be. An electric discharge along the capsule preheats the target and transforms it into a state of compressed liner. A subsequent TW femtosecond-laser pulse focused on a target end face causes ultrafast cold ignition of a small portion of the D{sup 3}He fuel. This laser impact generates energetic electrons and ions, which trigger a nuclear-physics mechanism of a catalytic heating of the fuel and also creates a detonation shock wave capable of propagating along the plasma filament. It is shown that the self-sustaining fusion burn wave can appear in the D{sup 3}He-{sup 9}Be plasma, in which case the bulk of the energy release is carried by nonradioactive ions, with the energy gain being in excess of 50. The possibility of probing the fusion process by means of gamma-ray spectroscopy is also discussed. The radiative-capture reactions {sup 3}He(d, {gamma}), D(d, {gamma}), and {sup 3}He({sup 3}He, {gamma}) naturally accompanying the burning of the D{sup 3}He fuel are shown to serve as a convenient diagnostic tool. A nuclear 'marker' of D{sup 3}He fusion on the basis of the detection of monochromatic gamma rays produced in the reaction {sup 9}Be({alpha}, {gamma}n), which is induced in the liner beryllium shell by energetic fusion alpha particles, is also examined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Nd ions on the chemical kinetic behavior of radiolytic transients in molten LiCl-KCl-NdCl3 salt mixtures

Pyrochemical reprocessing technologies can be used to recover valuable materials from used nuclear fuel (UNF), such as uranium. However, other critical materials, such as fission product neodymium, are challenging to recover from molten chloride eutectic mixtures (LiCl-KCl) due to the presence of multivalent states (Nd2+/Nd3+), disproportionation reactions, and re-dissolution in the molten chloride salt. Understanding, predicting, and controlling these processes is further complicated by the presence of ionizing radiation fields, for which little is known on the interaction of neodymium ions with the radiolytic transients (es– and Cl2.–) in molten LiCl-KCl salt mixtures. Here, chemical kinetics, from integrated electron pulse irradiation and transient absorption spectroscopy, are presented for the reaction of Nd3+ ions with es– and Cl2.– as a function of temperature (400–600 ?).

36 - MATERIALS SCIENCE↗

TRINIDI: Time-of-Flight Resonance Imaging With Neutrons for Isotopic Density Inference

Accurate reconstruction of 2D and 3D isotope densities is a desired capability with great potential impact in applications such as evaluation and development of next-generation nuclear fuels. Neutron time-of-flight (TOF) resonance imaging offers a potential approach by exploiting the characteristic neutron absorption spectra of each isotope. However, it is a major challenge to compute quantitatively accurate images due to a variety of confounding effects such as severe Poisson noise, background scatter, beam non-uniformity, absorption non-linearity, and extended source pulse duration. We present the TRINIDI algorithm which is based on a two-step process in which we first estimate the neutron flux and background counts, and then reconstruct the areal densities of each isotope and pixel. Both components are based on the inversion of a forward model that accounts for the highly non-linear absorption, energy-dependent emission profile, and Poisson noise, while also modeling the substantial spatio-temporal variation of the background and flux. Further, to do this, we formulate the non-linear inverse problem as two optimization problems that are solved in sequence. We demonstrate on both synthetic and measured data that TRINIDI can reconstruct quantitatively accurate 2D views of isotopic areal density that can then be reconstructed into quantitatively accurate 3D volumes of isotopic volumetric density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preface to the Special Issue on Signal Processing, Data Acquisition and Front-end Systems for Radiation Detection and Measurements

This special issue of the Journal of Signal Processing Systems focuses on advancement of signal processing and data-acquisition for radiation detection and measurements. The seven articles included cover diverse topics within the scope of radiation detection ranging from understanding of fundamental fission process, instrumentation, and application of radiation interaction (e.g., tomography and imaging). The articles focus on signal processing for fission spectrometer, neutron and gamma-ray computed tomography and artificial intelligence methods, dynamic neutron imaging system, pulse-pileup correction in x-ray spectroscopy and calibration methods in radiation measurement.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Integrated system modeling analysis of a cryogenic multi-cell deflecting-mode cavity resonator

A deflecting mode cavity is the integral element for six-dimensional phase-space beam control in bunch compressors and emittance transformers at high energy beam test facilities. RF performance of a high-Q device is, however, highly sensitive to operational conditions, in particular in a cryo-cooling environment. Using analytic calculations and RF simulations, we examined cavity parameters and deflecting characteristics of TM{sub 110,π} mode of a 5 cell resonator in a liquid nitrogen cryostat, which has long been used at the Fermilab A0 Photoinjector (A0PI). The sensitivity analysis indicated that the cavity could lose 30%–40% of deflecting force due to defective input power coupling accompanying non-uniform field distribution across the cells with 40 ∼ 50 MeV electron beam and 70–80 kW klystron power. Vacuum-cryomodules of the 5 cell cavity are planned to be installed at the Fermilab Advanced Superconducting Test Accelerator facility. Comprehensive modeling analysis integrated with multi-physics simulation tools showed that RF loading of 1 ms can cause a ∼5 K maximum temperature increase, corresponding to a ∼4.3 μm/ms deformation and a 1.32 MHz/K maximum frequency shift. The integrated system modeling analysis will improve design process of a high-Q cavity with more accurate prediction of cryogenic RF performance under a high power pulse operation.

43 PARTICLE ACCELERATORS↗

Pulse Mode Calibration of the Micro Pocket Fission Detector

The Micro-Pocket Fission Detector (MPFD) is a neutron sensor currently under development in the High Temperature Test Laboratory (HTTL) for use as a supporting instrument during material testing experiments performed at TREAT. The detector has the capability to observe the real-time neutron population while surviving the harsh radiation, and temperature conditions, which sets it apart from most neutron sensitive devices. The next step in the instrument development process is to define a method of calibrating pulse-mode operations. This procedure will allow the detector to be calibrated to allow for absolute measurements of localized neutron population in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature peaking at beginning of breakdown in 2.45 GHz pulsed off-resonance electron cyclotron resonance ion source hydrogen plasma

An experimental study of temperature and density evolution during breakdown in off-resonance ECR hydrogen plasma is presented. Under square 2.45 GHz microwave excitation pulses with a frequency of 50 Hz and relative high microwave power, unexpected transient temperature peaks that reach 18 eV during 20 {mu}s are reported at very beginning of plasma breakdown. Decays of such peaks reach final stable temperatures of 5 eV at flat top microwave excitation pulse. Evidence of interplay between incoming power and duty cycle giving different kind of plasma parameters evolutions engaged to microwave coupling times is observed. Under relative high power conditions where short microwave coupling times are recorded, high temperature peaks are measured. However, for lower incoming powers and longer coupling times, temperature evolves gradually to a higher final temperature without peaking. On the other hand, the early instant where temperature peaks are observed also suggest a possible connection with preglow processes during breakdown in ECRIS plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous negative electrocaloric effect in a relaxor/normal ferroelectric polymer blend with controlled nano- and meso-dipolar couplings

In general, a dielectric material will eject (or absorb) heat when an electric field is applied and absorb (or eject) heat when the field is removed, under isothermal condition, which is known as the normal (or negative) electrocaloric (EC) effect. For some applications, it is highly desired that an EC material will absorb heat (cooling the surrounding) without subsequent heating under an electric pulse. Here, we show that such an EC material can be realized in a properly designed hybrid normal ferroelectric/relaxor ferroelectric polymer blend in which the normal ferroelectric component induces dipole ordering in the relaxor polymer in the poled state, which can be switched to a de-poled state by an external field. More importantly, the de-poled state can be maintained by the relaxor component when the de-poling field is removed. Consequently, the hybrid blend exhibits a large cooling (an isothermal entropy change ΔS = 11.5 J kg -1 K -1 ) without the subsequent heating upon the application of an electric pulse.

36 MATERIALS SCIENCE↗

Promising lines of investigations in the realms of laboratory astrophysics with the aid of powerful lasers

The results of work on choosing and substantiating promising lines of research in the realms of laboratory astrophysics with the aid of powerful lasers are presented. These lines of research are determined by the possibility of simulating, under laboratory conditions, problematic processes of presentday astrophysics, such as (i) the generation and evolution of electromagnetic fields in cosmic space and the role of magnetic fields there at various spatial scales; (ii) the mechanisms of formation and evolution of cosmic gamma-ray bursts and relativistic jets; (iii) plasma instabilities in cosmic space and astrophysical objects, plasma jets, and shock waves; (iv) supernova explosions and mechanisms of the explosion of supernovae featuring a collapsing core; (v) nuclear processes in astrophysical objects; (vi) cosmic rays and mechanisms of their production and acceleration to high energies; and (vii) astrophysical sources of x-ray radiation. It is shown that the use of existing powerful lasers characterized by an intensity in the range of 10{sup 18}-10{sup 22} W/cm{sup 2} and a pulse duration of 0.1 to 1 ps and high-energy lasers characterized by an energy in excess of 1 kJ and a pulse duration of 1 to 10 ns makes it possible to perform investigations in laboratory astrophysics along all of the chosen promising lines. The results obtained by experimentally investigating laser plasma with the aid of the laser facility created at Central Research Institute of Machine Building (TsNIIMash) and characterized by a power level of 10 TW demonstrate the potential of such facilities for performing a number of experiments in the realms of laboratory astrophysics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear fuels for transient test reactors

Transient test reactors with the ability to test fissile specimens under extreme conditions have been crucial tools in the development of nuclear technologies. Less than 10 unique facility designs have ever been constructed, most of which remain operational today and still use the original nuclear fuel constructed for them more than 40 years ago. Historic fuel systems for transient test reactors vary in significant ways which have marked influences on reactor capabilities. Eventually, new fuel will be needed to support the longevity of transient test reactor missions. This paper reviews precedent transient reactor fuel systems in the context of their unique requirements. A few key conclusions are illustrated by comparing and contrasting these transient test reactors. Fuel composites which are mostly graphite can enable transient reactors with very high neutron fluence capability (>2E16 n/cm 2 ) and are amenable to longer “shaped” transients but cannot achieve pulses <10 ms in duration. Reducing the graphite-to-uranium ratio can yield a very narrow pulse capability but delivers less fluence and requires cores with considerably more fissile material. Designs based on uranium dioxide (UO 2 ) make use of readily available materials to create compact cores with narrow pulse width capabilities but with moderate neutron fluence capabilities (~2E15 n/cm 2 ). Uranium zirconium hydride (U-ZrHx) is a well-established fuel system for pulsing reactors which has been intermittently manufactured throughout the decades. U-ZrHx offers similar capabilities to UO 2 designs in terms of nuclear kinetics, but with about half the fluence capability (~1E15 n/cm 2 ). An evolution of the UO 2 system, termed “ternary ceramic” fuel, shows that dispersing UO 2 in zirconium oxide and calcium oxide can increase fluence capability greatly (~7E15 n/cm 2 ), but is not presently a commonly available fuel form. A unique composite of UO 2 and beryllium oxide (UO 2 -BeO) can be used to create a core with similar kinetics and compact core geometry as U-ZrHx designs, but with significantly higher fluence capability (~6E15 n/cm 2 ). Like ternary ceramic fuel, newly fabricated UO 2 -BeO would require reestablishing its historic manufacturing process which would be further complicated by the health hazards associated with beryllium. In conclusion, like most engineering problems, there is no perfect solution, but this paper outlines the advantages and disadvantages of candidate fuel options to help guide detailed evaluations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The potential of high-frequency forced pulsed water jet for nuclear decommissioning - 15367

Forced Pulse Water Jetting (FPWJ) has been demonstrated in other works as a credible and consistent method for removing coatings or otherwise preparing surfaces across numerous industries. Its applicability to the nuclear industry as a powerful tool for decommissioning and waste treatment has only recently being recognized and underpinning study is required before any deployment can be considered. Use of FPWJ within the nuclear sector for decommissioning and waste treatment, requires a different degree of surface finish to achieve a decontamination effect or an assured performance. This necessitates a greater erosion of the base metal than in other industries. The addition of a Forced Pulse Modulation Unit (FPMU) to a high pressure water jetting system offers performance shifts akin to the differences between High Pressure (HP) and Ultra High Pressure (UHP) water jets. Trials have been undertaken in a controlled environment to establish the number of cycles to achieve a given mass loss and or depth of penetration that would otherwise provide decontamination of mostly flat or simple geometry surfaces using a robotic arm for consistency and safety. It has also been shown that metalwork can be readily penetrated without risk of explosion, for example to allow draining of a gas cylinder. Most nuclear facilities have a plethora of pipe systems spanning various diameters. A considerable portion of the UK Sellafield site has 2 inch bore pipe. The FPMU technology is being adapted to consider applications in enclosed systems, such as decontamination of pipes. Exploratory works to date show there to be many physical attributes that influence performance that include, standoff of the jet, established propagated forced pulse jet length, interference from resultant water spray and angle of attack. Comparatively small changes to these parameters can have a profound effect on performance. The process is capable of removing 10's microns to several mms of metal progressively and repeatedly. This enables a credible potential treatment of plant and equipment at Intermediate Level Waste and High Level Waste thresholds. In considering this as a treatment method, a balance between performance, cost and environmental impact of effluents must be made and will be studied further during future active trials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for Quantifying the Uncertainties of LSIT Test Parameters, Test Results, and Full-Scale Mixing Performance Using Models Developed from Scaled Test Data

This report discusses the statistical methods for quantifying uncertainties in 1) test responses and other parameters in the Large Scale Integrated Testing (LSIT), and 2) estimates of coefficients and predictions of mixing performance from models that relate test responses to test parameters. Testing at a larger scale has been committed to by Bechtel National, Inc. and the U.S. Department of Energy (DOE) to “address uncertainties and increase confidence in the projected, full-scale mixing performance and operations” in the Waste Treatment and Immobilization Plant (WTP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗