Search NASA⌕ Search

SEARCH · Search NASA

Results for “operational integrated energy system models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Integrated energy balance analysis for Space Station Freedom

An integrated simulation model is described which characterizes the dynamic interaction of the energy transport subsystems of Space Station Freedom for given orbital conditions and for a given set of power and thermal loads. Subsystems included in the model are the Electric Power System (EPS), the Internal Thermal Control System (ITCS), the External Thermal Control System (ETCS), and the cabin Temperature and Humidity Control System (THC) (which includes the avionics air cooling, cabin air cooling, and intermodule ventilation systems). Models of the subsystems were developed in a number of system-specific modeling tools and validated. The subsystem models are then combined into integrated models to address a number of integrated performance issues involving the ability of the integrated energy transport system of Space Station Freedom to provide power, controlled cabin temperature and humidity, and equipment thermal control to support operations.

Tandler, John↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Marine energy supported multi-energy system planning and operation optimization for sustainable coastal community

The growing need for sustainable energy solutions in coastal areas necessitates the development of integrated systems that leverage abundant marine resources. In this study, a standalone Marine Energy Supported Multi-Energy System (MRE-MES) is designed for sustainable coastal community development, utilizing renewable marine resources, including offshore wind, wave, and solar energy, to address the energy needs of electricity, heat, freshwater, and hydrogen. The proposed MRE-MES incorporates a co-optimization model that simultaneously balances capacity planning and operational efficiency to minimize costs and environmental impacts. The system is tested under different renewable energy penetration levels and demand uncertainties, using a two-stage stochastic programming to account for variability in renewable resources and consumption needs. The experimental results indicate that in the optimal system capacity configuration, the percentage of total renewable energy generation is around 80 %, with or without capacity limitation constraints on PV, water tank, and hydrogen storage. Compared to the worst-case scenario in Monte Carlo experiments, two-stage stochastic optimization results in a more robust decision that effectively mitigates the risks posed by future uncertain demand conditions. In conclusion, the findings highlight the viability of marine energy for providing a resilient, comprehensive energy solution to coastal communities.

Capacity planning↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

“Best” Iterative Coupled-Cluster Triples Model? More Evidence for 3CC

To follow up on the unexpectedly good performance of several coupled-cluster models with approximate inclusion of 3-body clusters we performed a more complete assessment of the 3CC method for accurate computational thermochemistry in the standard HEAT framework. New spin-integrated implementation of the 3CC method applicable to closed- and open-shell systems utilizes a new automated toolchain for derivation, optimization, and evaluation of operator algebra in many-body electronic structure. We found that with a double-ζ basis set the 3CC correlation energies and their atomization energy contributions are almost always more accurate (with respect to the CCSDTQ reference) than the CCSDT model as well as the standard CCSD(T) model. The mean absolute errors in cc-pVDZ {3CC, CCSDT, and CCSD(T)} electronic (per valence electron) and atomization energies relative to the CCSDTQ reference for the HEAT data set, were {24, 70, 122} μE h /e and {0.46, 2.00, 2.58} kJ/mol, respectively. The mean absolute errors in the complete-basis-set limit {3CC, CCSDT, and CCSD(T)} atomization energies relative to the HEAT model reference, were {0.52, 2.00, and 1.07} kJ/mol, The significant and systematic reduction of the error by the 3CC method and its lower cost than CCSDT suggests it as a viable candidate for post- CCSD(T) thermochemistry applications, as well as the preferred alternative to CCSDT in general.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and Trade Space for Fuel Cell Powered Aircraft

Hydrogen has gained significant traction in research as a potential carbon-neutral fuel for future aircraft propulsion. The focus of this paper is on the hydrogen-electric aircraft (HEA) propulsion system which is a highly integrated network of high-power electrical, mechanical, fluidic, cryogenic, and thermal management components. These systems require careful analysis to determine the most efficient and light-weight design that ultimately reduces carbon emissions and operating cost. Fuel cell and energy storage sizing and optimization will be major factors that contribute to the aircraft feasibility independent of hydrogen storage. This paper describes the framework and modeling approach for the analysis of hydrogen-electric aircraft (HEA) propulsion systems for a under the National Aeronautics and Space Administration (NASA) Commercially-viable Hydrogen Aircraft for Reduction of Greenhouse Emissions (CH 2 ARGE) Project. For the first time, the Electrical Power System – Sizing and Analysis Tool (EPS-SAT) is used to conduct the sizing and trade studies on the hydrogen-electric aircraft propulsion system.

Hydrogen Electric Aircraft↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Implementing multi-settlement decentralized electricity market design for transactive communities with imperfect communication

Recent advances in information and communication technologies and smart metering, provides strategic opportunities for ``prosumers" to reform their conventional energy practices towards more consumer-centric economies. From an operational perspective, managing power distribution networks is becoming more difficult with such active grid-edge systems providing limited to no visibility or control. Transactive Energy (TE) has been emerging as a key enabler towards effectively and efficiently integrating prosumers into competitive electricity markets. This work presents a transactive implementation of community-centric markets. A co-simulation framework is developed for evaluating the proposed market structure with high-fidelity models. Case studies on the IEEE-123 node test system demonstrate that community-centric transactive markets can enable communities of prosumers to operate collaboratively as grid-edge systems. The potential benefits of implementing community-centric TE systems are also illustrated.

Mukherjee, Monish↗

Transactive Implementation of Decentralized Electricity Market for Grid-Edge Systems

The electricity landscape is evolving towards more decentralized approaches due to the proliferation of distributed energy resources and the participation of increasingly smart consumers and producers (prosumers). Recent advances in information and communication technologies and smart metering, provides strategic opportunities for “prosumers” to reform their conventional energy practices towards more consumer-centric economies. From an operational perspective, managing power distribution networks is becoming more difficult with such active grid-edge systems providing limited to no visibility or control. Transactive Energy (TE) has been emerging as a key enabler towards effectively and efficiently integrating prosumers into competitive electricity markets. This work presents a transactive implementation of community-centric markets. A co-simulation framework is developed for evaluating the proposed market structure with high-fidelity models. Case studies on the IEEE-123 node test system demonstrate that community-centric transactive markets can enable communities of prosumers to operate collaboratively as grid-edge systems. The potential benefits of implementing community-centric TE systems are also illustrated.

transactive, microgrids, centralized market operat↗

Distributionally Robust Bilevel Optimization Model for Distribution Network With Demand Response Under Uncertain Renewables Using Wasserstein Metrics

Here, we consider a distribution network integrating demand response (DR) participants in the presence of uncertain renewable suppliers and outdoor temperatures. A bilevel optimization model is proposed to capture the intricate dynamics between price-incentivized DR participants and distribution system operations, including energy procurement and active/reactive power flows. The model is formulated as a distributional robust bilevel optimization using Wasserstein metrics. We show favorable data-driven properties including out-of-sample guarantee and asymptotic consistency. Furthermore, we present a tractable mixed-integer linear programming reformulation and characterize the worst-case distribution. Computational experiments are conducted on a modified 33-bus system. Our findings underscore the efficacy of the pricing strategies derived from the proposed bilevel optimization model. These strategies not only effectively manage DR participants' behavior but also bring equity considerations among households with various characteristics to light. The results contribute to a deeper understanding of the interplay between distribution system operators and DR participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Thermal Expansion Coefficient, Viscosity and Melting Range in Simulation of PCM Embedded Heat Exchangers With and Without Fins

Phase change material heat exchangers (PCMHX) have an important role in integrating renewable energy systems. PCMHX can offer high storage density at various temperatures of interest and can be used for grid load shifting purposes. Numerical models enable engineers to estimate PCMHX performance for different design parameters and operating conditions. Modeling phase change phenomena is challenging due to the complex time-dependent nature of the process. The accuracy of models is highly sensitive to PCM thermo-physical properties. Thermal expansion coefficient (β), viscosity (μ) and melting temperature range (MR) of a PCM are important properties, especially when natural convection is not negligible. In PCMHX modeling, using less than accurate values for these properties can have significant impact on the simulation outcomes. These properties and discussions thereof are not readily available in the literature. This paper presents a brief review of the literature and a numerical study investigating the model sensitivity to the above-mentioned properties for PCMHX with and without fins. CFD is used to evaluate the charging (melting) phenomena. The study quantifies the impact of uncertainty in these properties on the melting rate and temperature profile. Constant wall temperature was considered as heat source with no heat loss to ambient. Here, the results show that β and μ has significant effect on the melting rate and evolution of the melting front. For a non-finned domain when comparing results for different published values of β and μ, the deviation in melting time can be up to 12.9% and 57.6% respectively. For high wall temperatures, change in melting range did not impact melting time. But when the wall temperature is reduced, up to 9.8% deviation in melting time is observed.

CFD↗

Piecewise Linear Optimization for Public EV Charging Depots in Different Utility Environments

With the proliferation of electric vehicles (EVs), EV supply equipment technology is being pushed to increasingly higher power levels, such as extreme fast charging (XFC) at 300kW or more. As more public XFC depots are connected to electric distribution systems, utility operators will mitigate their impact with pricing schemes and programs such as demand response, demand charges, and time-varying prices. In this paper we describe an XFC management system that combines an on-site battery energy storage system and an optimization application that minimizes the cost to operate the depot in light of the utility pricing programs. We have designed the optimizer specially to use fast and simple linear programming so that it can be deployed to low-cost computing platforms. We also describe how several utility pricing schemes are integrated into a single piecewise model, reducing the engineering effort to implement the optimizer in different utility environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗