Search NASA⌕ Search

SEARCH · Search NASA

Results for “readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

SALSA: a new versatile readout chip for MPGD detectors

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other usages of MPGD detectors like TPC or photon detectors. It integrates a frontend block and an ADC for each of the 64 channels, associated to a configurable DSP processor meant to correct data and reduce the raw data flux to limit the output bandwidth. It will be compatible with the continuous readout foreseen for the EPIC DAQ, but will also work in a triggered environment. Several prototypes are already produced in order to qualify the different blocks of the chip, in particular the frontend, the ADC and the clock generation. The next 32-channel prototype is currently under development and is planed to be produced in 2025. In conclusion, the final prototype will be produced and tested from 2026 for a production of the SALSA chip at the horizon of 2027.

Data processing↗

Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade

The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.

Osei Boakye, Prince [Grambling State U.]↗

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.

42 ENGINEERING↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

Electronic heterodyne moire deflectometry: A method for transient and three dimensional density fields measurements

Effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are investigated. The deferred deflectometry is used for measurements of nonsteady phase objects where it is difficult to complete the analysis of the field in real time. The sensitivity, accuracy and resolution of the system are calculated and it is shown that they are weakly affected by diffraction and by nonlinear recording. The feactures of the system are significantly improved compared with the conventional deferred intensity moire technique, and are comparable with the online heterodyne moire. The system was evaluated experimentally by deferred measurements of the refractive index gradients of a weak phase object consisting of a large KD*P crystal. This was done by photographing the phase object through a Ronchi grating and analyzing the tranparency with the electronic heterodyne readout system. The results are compared with the measurements performed on the same phase object with online heterodyne moire deflectometry and with heterodyne holographic interferometry methods. Some practical considerations for system improvement are discussed.

Stricker, Josef↗

Sensing strategies for toxic vapor detection

This work was motivated by the recommendations of the American Conference of Governmental Industrial Hygienists (ACGIH) that threshold limits for hydrazine, H2N-NH2 in air be lowered from 100 to 10 parts-per-billion (ppb) concentration levels. Hydrazine is one of the high-energy propellants used in large volumes in Space Shuttle, Titan, payloads, and other aerospace operations. Since analytical methods presently available for hydrazine detection and/or determination do not satisfy such low levels of detection, the ultimate goal of this research is the development and characterization of a portable and compact chemical sensor ideally capable to detect (in real time) 1 ppb of hydrazine, continuously and reversibly. The laboratory prototype developed as part of this project is comprised of: (1) a reactor part in which H2N-NH2 reacts, generating chemiluminescence emission, with tris(2,2'-bipyridine)ruthenium(III), which is immobilized on an ion-exchange polymeric materials of a perfluorinated hydrocarbon containing sulfonate groups as exchange centers (Nafion); (2) an electrochemical three-electrode cell posed at a potential at which the immobilized ruthenium complex could be reoxidized to the 3-oxidation state (as to provide reversible and continuous detection); and (3) a low power consumption photomultiplier tube to collect and quantitatively integrate the emitted photons with the help of auxiliary electronics and readout device.

Mottola, Horacio A.↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗

Smart-readout of the Skipper-CCD: Achieving Sub-electron Noise Levels in Regions of Interest

The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by counting the exact number of electrons. The total readout time is proportional to the number of measurements of the charge in each pixel. For some applications this time may be too long; however, researchers usually are interested only on certain region within the matrix of pixels. In this paper we present the development of a smart skipper readout technique that allows the user to specify regions of interest of the CCD matrix where an arbitrary (high) number of measurements of the same charge can taken to obtain the desired noise level, and far less measurements are performed in those regions that are less interesting to the researcher, therefore reducing the total readout time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

Ga:Ge array development

Work at the University of Arizona and at Lawrence Berkeley Laboratory on the development of a far infrared array camera for the Multiband Imaging Photometer on the Space Infrared Telescope Facility (SIRTF) is discussed. The camera design uses stacked linear arrays of Ge:Ga photoconductors to make a full two-dimensional array. Initial results from a 1 x 16 array using a thermally isolated J-FET readout are presented. Dark currents below 300 electrons s(exp -1) and readout noises of 60 electrons were attained. Operation of these types of detectors in an ionizing radiation environment are discussed. Results of radiation testing using both low energy gamma rays and protons are given. Work on advanced C-MOS cascode readouts that promise lower temperature operation and higher levels of performance than the current J-FET based devices is described.

Young, Erick T.↗

Electronic Tongue for Quantitation of Contaminants in Water

An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.

Buehler, Marlin↗