Search NASA⌕ Search

SEARCH · Search NASA

Results for “transmission system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

Embedded, Real-Time, and Distributed Traveling Wave Fault Location Method Using Graph Convolutional Neural Networks

This work proposes and develops an implementation of a fault location method to provide a fast and resilient protection scheme for power distribution systems. The method analyzes the transient dynamics of traveling waves (TWs) to generate features using the discrete wavelet transform (DWT), which are then used to train several graph convolutional network (GCN) models. Faults are simulated in the IEEE 34-node system, which is divided into three protection zones (PZs). The goal is to identify the PZ in which the fault occurs. The GCN models create a distributed protection scheme, as all nodes are able to retrieve a prediction. Given that message-passing between nodes occurs both during training and in the execution of the model, the resiliency of such schemes to communication losses was analyzed and demonstrated. One of the models, which only uses voltage measurements, was implemented on a Texas Instruments F28379D development board. The execution times were monitored to assess the speed of the protection scheme. It is shown that the proposed method can be executed in approximately a millisecond, which is comparable to existing TW protection in the transmission system. For experimental purposes, a DWT-based detection method is employed. A design of a setup to playback TWs using two development boards is also addressed.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Validation of the Fault Ride-Through Response of a Generic EMT Inverter Model by Laboratory Testing

This paper presents the validation of the fault ride-through response of a large-scale inverter model using laboratory testing of a commercial inverter. First, we present the generic inverter model specifications. The generic inverter control is developed based on the fault ride-through response performance requirements of IEEE Std 2800-2022 for inverter-based resources. Next, we present laboratory tests that emulate voltages at the inverter terminal resulting from balanced and unbalanced faults on the transmission system. The tests are performed on a commercia12.2 MVA battery storage inverter at the U.S. National Renewable Energy Laboratory. Comparisons of the model's response to the laboratory measurements show the generic model presented can predict the controlled response of the commercial equipment. The differences between the model's response and the laboratory measurements during the initial transient at fault inception are discussed.

fault ride-through↗

Deploying Intra-hour Uncertainty Analysis Tools to ABB’s GridView - CRADA 445

The quickly-changing generation resource mix in the US grid, with large additions of variable resources, retirements of traditional thermal generation, distributed generation and demand response, are creating new challenges on the traditional operation of both the generation and transmission systems. The ability to perform intra-hour high fidelity production cost modeling (PCM) is needed to allow grid operators and grid planners to integrate high penetration (more than 50%) of variable energy resources, and to make prompt well informed decisions in market operations and planning. In the last decade, PNNL has developed several stand-alone tools to enable grid operators and planners to understand the impact of high variable generation on their systems. These tools have been used is studies such as: (1) Evaluation the benefits of WECC balancing authorities coordination under high variable generation penetration , (2) Benefits of Energy Imbalance Market in the North West Power Pool and (3) Duke Energy and NV Energy solar integration studies. ABB’s GridView is a widely used commercial PCM tool. It is the tool used by WECC and their stakeholders to develop the WECC PCM planning model on bi-annual basis. This proposal is focused on the integrating of PNNL intra-hour uncertainty analysis tools to GridView.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Failure Probability Constrained AC Optimal Power Flow

Despite cascading failures being the central cause of blackouts in power transmission systems, existing operational and planning decisions are made largely by ignoring their underlying cascade potential. This paper posits a reliability-aware AC Optimal Power Flow formulation that seeks to design a dispatch point which has a low operator-specified likelihood of triggering a cascade starting from any single component outage. By exploiting a recently developed analytical model of the probability of component failure, our Failure Probability-constrained ACOPF (FP-ACOPF) utilizes the system's expected first failure time as a smoothly tunable and interpretable signature of cascade risk. Here, we use techniques from bilevel optimization and numerical linear algebra to efficiently formulate and solve the FP-ACOPF using off-the-shelf solvers. Extensive simulations on the IEEE 118-bus case show that, when compared to the unconstrained and N-1 security-constrained ACOPF, our probability-constrained dispatch points can significantly lower the probabilities of long severe cascades and of large demand losses, while incurring only minor increases in total generation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life Cycle Cost Analysis of Prestressed Concrete Poles Subjected to Wind, Surges, and Waves

Prestressed concrete (PC) poles are becoming popular choices to support coastal power transmission systems. However, the existing literature does not offer a detailed analysis of the effectiveness of PC poles in terms of long-term vulnerabilities and the direct and indirect costs. This is due to (1) lack of fragility models for PC poles and (2) lack of probabilistic wind, storm surge, and wave models in coastal settings. In this study, we address these gaps through a series of Monte Carlo simulations to estimate fragility of PC poles as a function of age and hazard (wind, surges, and waves) intensity, and the development of a probabilistic hazard model based on 10,000 years of synthetic tropical cyclone data. The probabilistic hazard model is used in conjunction with high-resolution hydrodynamic models to generate realizations of coastal wind, storm surges, and waves for the Louisiana and Mississippi coasts. A comprehensive life cycle cost analysis for a service life of 70 years considering direct and indirect losses is conducted to compare the performance of a transmission line located in Pascagoula, Mississippi, when wood poles are replaced by PC poles. Results showed that aging has a minor effect on the reliability of PC poles, highlighting the advantages of replacing wood poles with PC poles, especially in coastal areas. In addition, PC poles are significantly more cost-effective compared with wood poles over their life cycle, leading to an estimated saving of $11.55 million (68.17% reduction). The results of this study provide key insight to inform decision-making processes to keep the coastal power grids resilient and cost-effective against future storm hazards.

natural disasters↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources: Preprint

This study addresses the compliance of Inverter-based Resources (IBRs) with the IEEE Std 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a comprehensive controller development framework. This framework caters to maintaining ride-trhough operation or implementing strategic disconnections in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

grid↗

Distributed Energy Resource Interconnection Roadmap

Adopting strategic reforms to DER interconnection can help reduce interconnection delays, fairly allocate costs, improve transparency and equity, and support efficient and strategic investment in distribution and sub-transmission grids that can accommodate a rapidly evolving energy landscape. The Interconnection Innovation e-Xchange envisions this roadmap and its transmission system companion volume as collaborative resources to facilitate continued stakeholder discussions, problem-solving, and innovation as the U.S. works together to enable simpler, faster, and fairer interconnection of clean energy resources all while enhancing the reliability, resiliency, and security of our electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Design Process for Networked Microgrids

Changes in economic, technology, and environmental policies are resulting in a re-evaluation of the dependence on large central generation facilities and their associated transmission networks. Emerging concepts of smart communities/cities are examining the potential to leverage cleaner sources of generation, and the potential to integrate electricity generation with other municipal functions. When grid-connected, these generation assets can supplement the existing interconnections with the bulk transmission system, and in the event of an extreme event, they can provide power via networks of microgrids. While the design process for a single stand-alone microgrid is relatively well understood, the process of designing the infrastructure for networked microgrid operations has not been well studied. Because of the wide range of potential operational goals for microgrids, it is typical to follow the engineering process of developing an initial conceptual design, a preliminary design, a detailed design, and then a final as-built design. The conceptual design is typically completed without detailed engineering analysis, and the preliminary design is the first stage that requires it. This paper presents a process for developing the preliminary design for networked microgrids, which can then be used as a basis for the final as-built design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Smart Silicon Carbide Power Module With Pulse Width Modulation Over Wi-Fi and Wireless Power Transfer-Enabled Gate Driver, Featuring Onboard State of Health Estimator and High-Voltage Scaling Capabilities: Preprint

A wide range of utility applications require controllable switches with features such as high-voltage (HV) blocking and high-current carrying capacity especially at high pulse width modulation (PWM) frequency. Low and medium voltage utility applications such as motor drives and flexible AC transmission systems (FACTS) as well as solid state transformers (SST) could also benefit from a low-cost HV switching module. Wide band gap (WBG) semiconductors such as SiC and GaN MOSFETs are considered to be the present and next generation device choices, although they have their own limitations. For relatively HV applications with demanding thermal management, SiC is still the only choice, and GaN dominates the low voltage regime. This manuscript proposes a new half bridge power MOSFET module that is suitable for conventional H-bridge of multilevel configurations used in HV applications. Constructed from bare SiC dies, this half bridge module takes advantage of (1) optimized MOSFET placement inside the module, (2) customized heat exchanger, manifold and cooling, (3) integrated gate driver module with PWM over wi-fi to eliminate the need for low voltage signals, (4) wireless power transfer (WPT) enabled gate driver and other ancillary circuits, (5) and the option to incorporate an onboard state of health (SOH) estimator module onboard. The entire architecture has been designed and built at National Renewable Energy Laboratory (NREL), Golden, CO.

baseplate design↗

A Smart Silicon Carbide Power Module With Pulse Width Modulation Over Wi-Fi and Wireless Power Transfer-Enabled Gate Driver, Featuring Onboard State of Health Estimator and High-Voltage Scaling Capabilities

A wide range of utility applications require controllable switches with features such as high-voltage blocking and high-current carrying capacity, especially at high pulse width modulation (PWM) frequency. Low- and medium-voltage utility applications such as motor drives and flexible AC transmission systems as well as solid state transformers could also benefit from a low-cost high-voltage switching module. Wide-bandgap semiconductors such as silicon carbide (SiC) and gallium nitride (GaN) metal oxide semiconductor field effect transistors (MOSFETs) are considered to be the present and next-generation device choices, although they have limitations. For relatively high-voltage applications with demanding thermal management, SiC is still the only choice, and GaN dominates the low-voltage regime. This manuscript proposes a new half-bridge power MOSFET module that is suitable for conventional H-bridge of multilevel configurations used in high-voltage applications. Constructed from bare SiC dies, this half-bridge module takes advantage of (1) optimized MOSFET placement inside the module, (2) customized heat exchanger, manifold, and cooling, (3) integrated gate driver module with pulse width modulation (PWM) over wi-fi to eliminate the need for low-voltage signals, (4) wireless power transfer (WPT)-enabled gate driver and other ancillary circuits, (5) and the option to incorporate an onboard state-of-health (SOH) estimator module. The entire architecture has been designed and built at the National Renewable Energy Laboratory (NREL) in Golden, CO.

Ga2O3 devices↗

Catalyzed oxidation of IG-110 nuclear graphite by simulated fission products Ag and Pd nanoparticles

To evaluate the stability of nuclear materials in high temperature gas reactors under air ingress conditions, catalytic oxidation of IG-110 graphite by two simulated fission products, metallic Pd and Ag, was studied in oxidative atmosphere and at temperatures up to 1000°C using an integrated furnace, mass spectroscopy and infrared spectroscopy system. Transmission electron microscopy and X-ray diffraction studies show that Pd and Ag nanoparticles were successfully introduced onto powdery IG-110 graphite through an impregnation and subsequent heat-treatment process. The combined mass spectroscopy and infrared spectroscopy methods allow simultaneous analysis of two gaseous products, CO and CO 2 , and separate measurements of activation energy for their formation reactions. It was found that the introduction of Pd or Ag to IG-110 graphite substantially catalyzed the oxidation of graphite, characteristic of decreased onset temperatures for the oxidation of graphite. Moreover, the catalytic effects by Pd and Ag are considerably different based on measured concentration ratios of CO 2 to CO as a function of oxidation temperatures. Ag makes the graphite oxidation commence at approximately 400°C with CO 2 being the dominant product. In contrast, Pd significantly increases the concentration ratio of CO 2 to CO at temperatures higher than approximately 690°C, although it decreases the onset temperature for the oxidation reaction to around 525°C. To understand the catalytic difference, the mechanism of the graphite oxidation was discussed based on the changes of surface oxygen species on Ag and Pd.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wave energy converter buoy for Arctic observations

Ocean observation buoys are currently powered-constrained by battery storage capacity or available solar power. Power constraints limit the number of measurements that can be made and the lifetime of the buoys. Ocean surface wave energy could be used for power production, but wave energy converters are not yet commercially available for ocean observation buoys. Here we present the design and testing of a drifting wave energy converter buoy using a pendulum transmission system (PTS). The wave energy converter buoy was designed to operate in Arctic temperatures and wave conditions, but it could be used in areas with warmer temperatures and larger waves. Field tests measured a maximum power production of 5 watts in waves with a significant wave height of 0.42 meters and a ten minute average power production of 37 milliwatts. Power production increased with the energy period and significant wave height. The energy harvesting capabilities of the PTS showed the utility of adding a wave energy conversion device to a drifting ocean observation buoy.

Arctic observations↗

What Technical Choices Matter to Characterize Heat Wave and Cold Snap Events in Support of Bulk Power Grid Reliability Studies?

Extreme weather events, such as Heat Waves (HW) and Cold Snaps (CS), pose significant risks to the power grid. The United States (U.S.) Federal Energy Regulatory Commission Order No. 896 mandates regional coordination standards that account for extreme thermal events. However, the lack of a universal definition for extreme thermal events may lead to inconsistent compliance efforts among neighboring entities, undermining the reliability of the transmission system. This study directly addresses this challenge by systematically evaluating how varying technical choices in defining HW and CS fundamentally impact the characterization and ranking of extreme events for power grid reliability studies. We used 12 event definitions and multiple temperature spatial aggregation approaches to construct historical (1980–2024) regional extreme thermal event libraries across North American Electric Reliability Corporation (NERC) subregions in the conterminous U.S. We examined the sensitivity of event characteristics (e.g., duration, frequency, intensity, and spatial coverage) to different definitions. While some definitions produced similar libraries and top event rankings, definitions based on moving-window-averaged temperatures yielded markedly different characteristics. Spatial aggregation methods had minimal impact on heat wave or cold snap intensity, frequency and duration but significantly influenced spatial coverage. The top events identified across different aggregation methods were consistent, but their ranking order varied. These findings offer critical insights for characterizing and selecting extreme thermal events and for supporting local and cross-regional coordination as required by reliability standards.

Wan, Heng [Pacific Northwest National Laboratory (↗

Distributed Load Shedding Application Architecture and Bi-Level Predictive Estimator Algorithm

Increasing penetrations of distributed renewables are decreasing the effectiveness of traditional decentralized under-frequency load shedding (UFLS) schemes. As more distribution circuits begin to back-feed the transmission system, operation of traditional UFLS may exacerbate frequency instability. This paper presents the conceptual framework for a data-rich environment to coordinate UFLS across multiple distribution providers based on the laminar coordination framework in order to ensure optimal adaptive setting of UFLS relays. Communication and control are enabled through a distributed implementation of the IEC 61968-1 Common Information Model message bus structure. In addition to the proposed architecture, a novel adaptive UFLS scheme informed by a bi-level state estimator to create optimal relay setpoints is introduced. Initial simulation results are presented for the IEEE 14-bus test system on scenarios leading to mis-operation of traditional UFLS.

Anderson, Alexander A.↗