Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid (AVC-TeDP)

The purpose of this effort was to advance the selection, characterization, and modeling of a propulsion electric grid for a Turboelectric Distributed Propulsion (TeDP) system for transport aircraft. The TeDP aircraft would constitute a miniature electric grid with 50 MW or more of total power, two or more generators, redundant transmission lines, and multiple electric motors driving propulsion fans. The study proposed power system architectures, investigated electromechanical and solid state circuit breakers, estimated the impact of the system voltage on system mass, and recommended DC bus voltage range. The study assumed an all cryogenic power system. Detailed assumptions within the study include hybrid circuit breakers, a two cryogen system, and supercritical cyrogens. A dynamic model was developed to investigate control and parameter selection.

power↗

Online Static Load Model Estimation in Distribution Systems: Preprint

The paper focuses on parameter identification for time varying voltage dependent polynomial load models, namely the constant impedance (Z), constant current (I), and constant power (P), in the distribution systems. Typically, parameter identification has been done for aggregated loads at substations for the transmission planning studies. Given the higher voltage volatility faced by active distribution systems, this paper takes the load model estimation to the distribution networks. The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. Least squares estimation (LSE) method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations of the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system due to varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data, and the use of dynamic simulations to create synthetic measurement data in the absence of real ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of solar photovoltaic energy curtailment due to volt–watt control

The widespread deployment of autonomous inverter‐based solutions for mitigating voltage and frequency excursions caused by high‐penetration photovoltaic (PV) systems has drawn increased attention due to their potential impact on PV production. It is now important to quantify the amount of solar energy curtailed as a result of the activation of inverter‐based grid support functions (GSFs). This study proposes a methodology for estimating the impact of volt–watt on customer PV energy curtailment using smart meter voltage data. This method estimates maximum possible curtailment for a given volt–watt curve based on the customer smart meter voltage during the time period of interest. This study compares the proposed methodology with field measurements using irradiance and customer inverter data from Hawaii as well as with results from a previous simulation‐driven study on the impact of advanced inverter GSF activation on PV energy curtailment. Results show that the proposed method for estimating lost PV production caused by volt–watt control aligns reasonably well with field measurements and computer simulations for hundreds of customers. The proposed method could be used to estimate customer energy curtailment, which could inform future compensation mechanisms for utilities leveraging customer‐sited resources to mitigate high voltage and defer infrastructure upgrades.

Emmanuel, Michael↗

Determining circuit model parameters from operation data for PV system degradation analysis: $\mathrm{PVPRO}$

Physics-based circuit parameters like series and shunt resistance are essential to provide insights into the degradation status of photovoltaic (PV) arrays. However, calculating these parameters typically requires a full current-voltage characteristic (I-V curve), the acquisition of which involves specific measurement devices and costly methods. Thus, I-V curves of the PV system level are often not available. Here this paper proposes a methodology (PVPRO) to estimate these I-V curve parameters using only operation (string-level DC voltage and current) and weather data (irradiance and temperature). PVPRO first performs multi-stage data pre-processing to remove noisy data. Next, the time-series DC data are used to fit an equivalent circuit single-diode model (SDM) to estimate the circuit parameters by minimizing the differences between the measured and estimated values. In this way, the time evolutions of the SDM parameters are obtained. We evaluate PVPRO on synthetic datasets and find an excellent estimation of both SDM and the key I-V parameters (e.g., open-circuit voltage, short-circuit current, maximum power, etc.) with an average relative error of 0.55%. The performance, especially the extracted degradation rate of parameters, is robust to various measurement noises and the presence of faults. In addition, PVPRO is applied to a 271 kW PV field system. The relative error between the real and estimated operation voltage and current is less than 1%, suggesting that degradation trends are well captured. PVPRO represents a promising open-source tool to extract the time-series degradation trends of key PV parameters from routine operation data.

14 SOLAR ENERGY↗

A Voltage Inference Framework for Real-Time Observability in Active Distribution Grids

Active distribution grids are gaining traction to meet the growing environmental, socio-economic, and sustainability targets. Various advanced smart grid technologies facilitate the integration of Distributed Energy Resources (DERs) by supporting the bi-directional power flow. The limited observability of distribution grids, primarily related to their location at the very edge of power system infrastructure, brings challenges to optimal grid management. Moreover, only a limited number of measurements at regular intervals are usually available. This paper presents a novel inference framework, referred to as “Voltage Inference”, to overcome the observability issues. The proposed framework employs a prediction step based on the Multivariate Taylor series approximation, followed by a corrector step that minimizes the estimation error to infer the otherwise unknown voltages from the available measurements. Furthermore, numerical results on the IEEE 13-bus test feeder validate the accuracy and computational performance of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microporous SiO{sub 2} with huge electric-double-layer capacitance for low-voltage indium tin oxide thin-film transistors

Electric-double-layer (EDL) effect is observed in microporous SiO{sub 2} dielectric films deposited at room temperature by plasma-enhanced chemical vapor deposition method. Indium tin oxide thin-film transistors gated by such microporous SiO{sub 2} gate dielectric are fabricated at room temperature, and a low operating voltage of 1.5 V is obtained due to the huge EDL specific capacitance (2.14 {mu}F/cm{sup 2}). The field-effect electron mobility is estimated to be 118 cm{sup 2} V{sup -1} s{sup -1}. Current on/off ratio and subthreshold gate voltage swing are estimated to be 5x10{sup 6} and 92 mV/decade, respectively. Room-temperature deposited microporous SiO{sub 2} dielectric is promising for low-power field-effect transistors on temperature sensitive substrates.

36 MATERIALS SCIENCE↗

Period Modulation For Telemetry

In innovative telemetry scheme, time between pulses of light transmitted along optical fiber represents measured quantity. In period modulator, time varied by varying control-input voltage, which serves as critical voltage of relaxation oscillator. Demodulator is simple state estimator, no discriminator or phase-locked loop needed. Applicable to radio or wire transmission. Pulses proportional to temperature, pressure, voltage, or other variable monitored remotely.

Kirkham, Harold↗

Electric properties and carrier multiplication in breakdown sites in multi-crystalline silicon solar cells

This paper studies the effective electrical size and carrier multiplication of breakdown sites in multi-crystalline silicon solar cells. The local series resistance limits the current of each breakdown site and is thereby linearizing the current-voltage characteristic. This fact allows the estimation of the effective electrical diameters to be as low as 100 nm. Using a laser beam induced current (LBIC) measurement with a high spatial resolution, we find carrier multiplication factors on the order of 30 (Zener-type breakdown) and 100 (avalanche breakdown) as new lower limits. Hence, we prove that also the so-called Zener-type breakdown is followed by avalanche multiplication. We explain that previous measurements of the carrier multiplication using thermography yield results higher than unity, only if the spatial defect density is high enough, and the illumination intensity is lower than what was used for the LBIC method. The individual series resistances of the breakdown sites limit the current through these breakdown sites. Therefore, the measured multiplication factors depend on the applied voltage as well as on the injected photocurrent. Both dependencies are successfully simulated using a series-resistance-limited diode model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Substation Cable Layouts for EMP Coupling Analysis

Direct coupling of early-time high-altitude electromagnetic pulse (HEMP) to substation control cables is simulated for cable layouts based on surveys of seven electrical substations in the United States. An analytic transmission line modeling code is used to estimate worst-case coupled current at the terminations of cable segments in or near the control shack. Where applicable, an induced voltage due to cable shield grounding is also estimated. Various configurations are simulated, including cables with different elevations, lengths, radii, and terminations. Plots of the coupled HEMP effects are given, and general relationships between these effects and the substations geometric and material parameters are highlighted and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Plasma sheath effects and voltage distributions of large high-power satellite solar arrays

Knowledge of the floating voltage configuration of a large array in orbit is needed in order to estimate various plasma-interaction effects. The equilibrium configuration of array voltages relative to space depends on the sheath structure. The latter dependence for an exposed array is examined in the light of two finite-sheath effects. One effect is that electron currents may be seriously underestimated. The other is that a potential barrier for electrons can occur, restricting electron currents. A conducting surface is assumed on the basis of a conductivity argument. Finite-sheath effects are investigated. The results of assuming thin-sheath and thick-sheath limits on the floating configuration of a linearly connected array are studied. Sheath thickness and parasitic power leakage are estimated. Numerically computed fields using a 3-D code are displayed in the thick-sheath limit.

Parker, L. W.↗

Aggregated DER_A Model Parameterization via Online Moving Horizon Estimation

Here, this paper introduces a methodology for parameterizing the DER_A model using a novel smooth mathematical representation, simplifying the process and preserving accuracy in modeling inverter-based generator (IBG). The methodology employs an online parameterization process that can operate in real-time. The model parameterization process is structured into five sequential steps, each targeting a specific aspect of the DER_A model through moving horizon estimation. This approach adapts to systems with varying voltage and frequency support requirements by selectively applying each step. Simulation results on systems with both known and unknown parameters validate the methodology’s effectiveness. The online moving horizon estimation technique accurately captures the dynamics of the overall system and ensures that the parameterized DER_A model closely mirrors the real system’s voltage, current, and power dynamics. The findings highlight the potential of this methodology to substantially improve and simplify the dynamic modeling of power systems, paving the way for more reliable and robust IBG and grid integration.

42 ENGINEERING↗

Online Static Load Model Estimation in Distribution Systems

This paper focuses on parameter identification for time-varying voltage-dependent polynomial load models in distribution systems—namely, the constant impedance (Z), constant current (I), and constant power (P). The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. The least- squares estimation method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations on the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system caused by varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data. Finally, the paper uses dynamic simulations data (synthetic high-resolution measurements) to further improve the estimation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Temporal Ni K-Edge X-ray Absorption Spectroscopy Study Reveals the Kinetics of the Ni Redox Behavior of the Iron-Nickel Oxide Bimetallic OER Catalyst

Operando X-ray absorption spectroscopy (XAS) can be utilized to probe the phase and structural changes of FeNiOx and similar transition metal oxide electrocatalysts during electrocatalytic reactions. However, capturing the temporal changes occurring in the operando chemistry of electrocatalysts has been little studied. Here, in this work, we successfully capture the time-resolved changes at the Ni K-edge for both the X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) regions of an aqueous phase synthesized FeNiO x bimetallic nanoparticle electrocatalyst. During a stepped voltage experiment, the temporal change in the Ni K-edge was observed as the applied voltage was stepped from 0.7 to 0.8 V versus the silver/silver chloride reference electrode, and the change observed is associated with the Ni redox transition from the 2+ to 3+/4+ oxidation state. Individual XAS spectra were obtained in 90 s, and a total of 9 scans post voltage step showed a unique transition from a hydroxide to an oxyhydroxide phase. The shift in absorption edge energy position and the changes in spectral shape for individual scans explain the typically observed broadening of the Ni K-edge XANES spectrum during time-averaged operando XAS, and a kinetic analysis revealed a first-order observed rate constant, |k obs |, of 0.00426 s –1 and a half-life (t 1/2 ) of 163 s. Multivariate curve resolution-alternating least squares analysis followed by linear combination fitting analysis for time-averaged versus time-resolved Ni K-edge changes upon voltage step show distinct differences in estimated contributions from Ni 2+ oxide/hydroxide phases. Detailed EXAFS modeling shows the phase transition from hydroxide to oxyhydroxide on top of the unchanged metallic core.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of nonlinear interaction between bunched beam and intermediate cavities in a relativistic klystron amplifier

In intermediate cavities of a relativistic klystron amplifier (RKA) driven by intense relativistic electron beam, the equivalent circuit model, which is widely adopted to investigate the interaction between bunched beam and the intermediate cavity in a conventional klystron design, is invalid due to the high gap voltage and the nonlinear beam loading in a RKA. According to Maxwell equations and Lorentz equation, the self-consistent equations for beam-wave interaction in the intermediate cavity are introduced to study the nonlinear interaction between bunched beam and the intermediate cavity in a RKA. Based on the equations, the effects of modulation depth and modulation frequency of the beam on the gap voltage amplitude and its phase are obtained. It is shown that the gap voltage is significantly lower than that estimated by the equivalent circuit model when the beam modulation is high. And the bandwidth becomes wider as the beam modulation depth increases. An S-band high gain relativistic klystron amplifier is designed based on the result. And the corresponding experiment is carried out on the linear transformer driver accelerator. The peak output power has achieved 1.2 GW with an efficiency of 28.6% and a gain of 46 dB in the corresponding experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SiGe quantum dots for fast hole spin Rabi oscillations

We report on hole g-factor measurements in three terminal SiGe self-assembled quantum dot devices with a top gate electrode positioned very close to the nanostructure. Measurements of both the perpendicular as well as the parallel g-factor reveal significant changes for a small modulation of the top gate voltage. From the observed modulations, we estimate that, for realistic experimental conditions, hole spins can be electrically manipulated with Rabi frequencies in the order of 100 MHz. This work emphasises the potential of hole-based nano-devices for efficient spin manipulation by means of the g-tensor modulation technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Common features of particle beams and x-rays generated in a low energy dense plasma focus device

Features of energetic charged particle beams and x-ray emission in a low energy (1–2 kJ) plasma focus (DPF) device are described and the possible mechanism are explained based on circuit analyses and energy balance in the DPF system. In particular, the resistance and the voltage across the plasma column are estimated to explain the mechanisms of the generation of particle beams and hard x-ray. The analysis shows that the total inductance of a DPF might have played a role for enhancement of the particle beams and x-ray emissions during the phase of anomalous resistance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗