Evaluating Crystallinity in Thermoplastic Composites for Aerospace Applications

Polymer matrix composites (PMCs) offer many benefits for the aerospace industry due to their potential for weight reduction when compared to metal or ceramic based materials. Most PMCs currently in flight use thermoset matrices, however, thermoplastic resins are being explored as alternatives due to their ability to be remelted, which is of particular interest due to the potential for in-situ repair and faster production. Most thermoplastic resins are semicrystalline polymers. The properties of semicrystalline thermoplastics are directly influenced by their crystallinity, which can vary due to many factors including thermal treatments, environmental conditions, and mechanical deformation. Within thermoplastic PMC parts, crystallinity gradients can arise due to variations in part geometry, across part thicknesses, and along bonded joints. Monitoring the crystallinity of thermoplastic composites is key to ensuring these materials meet the high demands required for aerospace. Several different analytical techniques exist that can be used to characterize the bulk crystallinity of thermoplastic materials. However, many existing methods lack the specificity required to identify the subtle variations in crystallinity that may play a significant role in the performance and durability of PMC parts. Because of this, a significant amount of work is still required to fully characterize and understand the crystallinity profiles of thermoplastic PMCs and the resulting impact to material properties. This talk discusses the use of multiple techniques such as Differential Scanning Calorimetry, Polarized Light Optical Microscopy, and Fourier-Transform Infrared Spectroscopy to characterize the crystallinity in carbon fiber/thermoplastic composites. Samples of different crystallinity profiles were manufactured using various cooling procedures. This work aims to provide the fundamental data necessary to understand the effects of crystallinity on thermoplastic PMCs, which is key to advancing their use in aerospace applications.

Thermoplastics

Adapter Signaling Evaluations on EVs [Slides]

In case J3400 and J3400/1 define a basic analog signaling approach for DC charging adapters to communicate over-temperature events to both the EV and EVSE. They also require the EV to implement mitigation and corrective actions in cases where the EVSE does not respond to adapter thermal signals. In this study, multiple production vehicles were evaluated for responsiveness to assess field readiness and ensure consistent performance in accordance with the SAE J1772, J3400 and J3400/1 standards. A series of test cases were developed and executed across different vehicles, using an adapter thermal breakout fixture designed by NLR for evaluations. The results revealed notable variations in behavior: some vehicles expected to comply with J1772 were found to be non-responsive under certain conditions. Additionally, while some EV OEMs appear to align with the J3400 standard, discrepancies exist due to its evolving nature, resulting in inconsistent implementation of the latest requirements. These findings highlight the need for alignment within standards organizations to ensure consistent interpretation, encourage compliance, and reduce potential confusion across implementations.

33 ADVANCED PROPULSION SYSTEMS

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Mechanisms of Protonic Nonvolatile Memory Device

A nonvolatile memory device based on protonic transport in oxides has been proposed. The mobile H+ ions are introduced into the SiO2 layer by annealing Si/SiO2/Si structures in H2 at temperatures greater than 500 deg C. This effect has only been observed for confined oxides that have been annealed at greater than or equal to 1100 C prior to the hydrogenation anneal. This includes buried oxides such as Unibond and SIMOX as well as thermal oxides annealed with a polysilicon cap. An applied field moves the charge within the oxide and the charge stops moving when the field is removed. In a memory device, the hydrogen-annealed oxide is the gate oxide and the position of the mobile charge is sensed by the shift of the I-V curve. Much is still not understood about the motion of the charge across the buried oxide. Previous work has assumed that H+ transport and the time it takes to traverse the oxide is governed by interactions within the bulk of the oxide. Based on parameters that affect the transport time, we conclude that H+ trapping and detrapping at the Si/SiO2 interface are more important than H+ interactions within the oxide bulk. These parameters include the applied field, the H+ concentration and the oxide thickness. One consequence is that projections of device write-time based on the previous assumptions of H+ transport mechanisms may be overly optimistic.

P J Macfarlane

Sample Return Science by Hayabusa Near-Earth Asteroid Mission

Assigning the material species to each asteroid spectral type and finding out the corresponding meteorite category is crucial to make the global material map in the whole asteroid belt and to understand the evolution of the asteroid belt. Recent direct observations by spacecrafts are revealing new intriguing aspects of asteroids which cannot be obtained solely from ground-based observations or meteorite studies. However identification of the real material species constituting asteroids and their corresponding meteorite analogs are still ambiguous. Space weathering makes difficult to identify the true material, and there is still a great gap between the remote sensing data on the global surface and the local microscopic data from meteorites. Sample return from asteroids are inevitable to solve these problems. For this purpose sample return missions to asteroids belonging to various spectral classes are required. The HAYABUSA spacecraft (prelaunch name is MUSESC) launched last year is the first attempt on this concept. This report presents outline of the mission with special stress on its science.

A Fujiwara

Internally Catalyzed Hydrogen Atom Transfer (I-CHAT)—A New Class of Reactions in Combustion Chemistry

The current paradigm of low-T combustion and autoignition of hydrocarbons is based on the sequential two-step oxygenation of fuel radicals. The key chain-branching occurs when the second oxygenation adduct (OOQOOH) is isomerized releasing an OH radical and a key ketohydroperoxide (KHP) intermediate. The subsequent homolytic dissociation of relatively weak O–O bonds in KHP generates two more radicals in the oxidation chain leading to ignition. Based on the recently introduced intramolecular “catalytic hydrogen atom transfer” mechanism (J. Phys. Chem. 2024, 128, 2169), abbreviated here as I-CHAT, we have identified a novel unimolecular decomposition channel for KHPs to form their classical isomers—enol hydroperoxides (EHP). The uncertainty in the contribution of enols is typically due to the high computed barriers for conventional (“direct”) keto–enol tautomerization. Remarkably, the I-CHAT dramatically reduces such barriers. The novel mechanism can be regarded as an intramolecular version of the intermolecular relay transfer of H-atoms mediated by an external molecule following the general classification of such processes (Catal. Rev.-Sci. Eng. 2014, 56, 403). Here, we present a detailed mechanistic and kinetic analysis of the I-CHAT-facilitated pathways applied to n-hexane, n-heptane, and n-pentane models as prototype molecules for gasoline, diesel, and hybrid rocket fuels. We particularly examined the formation kinetics and subsequent dissociation of the γ-enol-hydroperoxide isomer of the most abundant pentane-derived isomer γ-C5-KHP observed experimentally. To gain molecular-level insight into the I-CHAT catalysis, we have also explored the role of the internal catalyst moieties using truncated models. All applied models demonstrated a significant reduction in the isomerization barriers, primarily due to the decreased ring strain in transition states. In addition, the longer-range and sequential H-migration processes were also identified and illustrated via a combined double keto–enol conversion of heptane-2,6-diketo-4-hydroperoxide as a potential chain-branching model. To assess the possible impact of the I-CHAT channels on global fuel combustion characteristics, we performed a detailed kinetic analysis of the isomerization and decomposition of γ-C5-KHP comparing I-CHAT with key alternative reactions—direct dissociation and Korcek channels. Calculated rate parameters were implemented into a modified version of the n-pentane kinetic model developed earlier using RMG automated model generation tools (ACS Omega, 2023, 8, 4908). Simulations of ignition delay times revealed the significant effect of the new pathways, suggesting an important role of the I-CHAT pathways in the low-T combustion of large alkanes.

Biochemistry & Molecular Biology

High-Performance Reactionless Scan Mechanism

A high-performance reactionless scan mirror mechanism was developed for space applications to provide thermal images of the Earth. The design incorporates a unique mechanical means of providing reactionless operation that also minimizes weight, mechanical resonance operation to minimize power, combined use of a single optical encoder to sense coarse and fine angular position, and a new kinematic mount of the mirror. A flex pivot hardware failure and current project status are discussed.

Ellen I Williams

Optical characterization of solar concentrator mirrors using the solar beam of the JPL 25-foot space simulator

The Jet Propulsion Laboratory 25-foot space simulator with its 5.8-m (19-ft) diameter simulated solar beam provides an excellent facility for measuring the optical characteristics of parabolic solar concentrator panels and gores. The virtual source position and size were determined by using a single lamp of the 37 xenon 30-kW source array with only the center lens in the 19-channel optical mixer. This data was used to define the optical test geometry, and it allowed accurate measurement of focal length and surface deviations of the mirror under test. A flux distribution of a typical solar concentrator placed directly on the solar beam gives measurements of performance at the focal point of the parabolic surface.

Maurice J Argoud

Green Era Anaerobic Digester

Green Era Educational NFP constructed and commissioned the Green Era Renewable Energy & Urban Farming Campus in Chicago’s Auburn Gresham neighborhood. The project transformed a long-vacant brownfield site into a commercial-scale anaerobic digestion facility that converts food waste into renewable natural gas and nutrient-rich material for agricultural use. The facility can process up to 80,000 wet tons of food waste annually and supports approximately 15 permanent jobs while advancing food waste diversion, renewable energy production, nutrient recovery and community revitalization.

03 NATURAL GAS

Performance of Two Battery Prognostic Applications used by Two Octocopters for Safe Low Altitude Autonomous Flight Operations

This paper addresses the problem of building trust in online predictions of the remaining available flying time for two different electric Unmanned Aerial Vehicles (eUAVs) powered by lithium-ion-polymer batteries. Flight tests for various automation research missions for the two vehicles were monitored using two on-board battery health management applications to make predictions of the remaining flying time (RFT) for each eUAV and to predict the state of the battery. Playback of the voltage, current and temperature profiles of the battery discharge were used to assess the accuracy of the estimation of the voltage and the charge states of the models as well as the estimate of the RFT. The reference ground truth values were the observed landing time and the measured battery pack resting pack voltage 20 minutes after the flight. The predicted RFT, state of charge (SoC), and state of energy (SoE) were compared with the observed results. Noise values of one standard deviation from the mean values of the internal charge states of the battery model during a reference run were used to vary the states during simulation. One application used an equivalent circuit model of the electrical dynamics of the battery pack, and the other application used a reduced-order electrochemistry model. The variation of the model state components was compared to the variation in the estimate of the RFT and the variation in the SoE to estimate a confidence factor. Variation in the estimates caused by factors affecting the off-line laboratory parameter identification experiments is considered. Variation in the estimates due to environmental factors are discussed.

Assurance

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Performance of the Lester battery charger in electric vehicles

Tests are performed on an improved battery charger. The primary purpose of the testing is to develop test methodologies for battery charger evaluation. Tests are developed to characterize the charger in terms of its charge algorithm and to assess the effects of battery initial state of charge and temperature on charger and battery efficiency. Tests show this charger to be a considerable improvement in the state of the art for electric vehicle chargers.

Vivian, H. C.

Prevention of Coupled Structure-Propulsion Instability (POGO) On The Space Shuttle

Many liquid-propellant rocket vehicles have experienced longitudinal vibration, nicknamed pogo after the jumping stick, due to an instability arising from interaction of the vehicle structure with the propulsion system. These vibrations can produce an intolerable environment for astronauts and equipment, can overload vehicle structure, and can lead to loss of propulsion performance. A NASA monograph concerned with the prevention of pogo is well on its way toward publication and should serve as a useful guide to design for the Space Shuttle. The paper will briefly describe the nature of the pogo phenomenon, present a summary of past instabilities, relate the possible deleterious effects of pogo, and discuss the contents of the design criteria monograph. Finally, research tasks are recommended for support of pogo development activities on the Space Shuttle.

S. Rubin

Battery Cell-to-Pack Scaling Laws for Electric Aircraft

Battery pack gravimetric energy density is one of the most important, yet often miss-estimated design parameters for sizing all-electric aircraft. Proper accounting for thermal, structural, and operational safety margins are frequently lost when extrapolating performance from the cell level to the aircraft level. This paper summarizes the relevant engineering and certification details needed to better account for the penalties associated when assembling battery packs. The relationship between the cell and pack energy density is not linear, as is often assumed. Furthermore, the relationship varies depending on pack requirements, cell chemistry, and architecture. Parametric, high-fidelity models are used to determine optimal battery pack sizes over a range of conditions to better quantify technology scaling effects.

Battery Electric Aircraft

Review of European Microgravity Measurements

AA In a French/Russion cooperation, CNES developed a microgravity detection system for analyzing the Mir space station micro-g-environment for the first time. European efforts to characterize the microgravity (1/9) environment within a space laboratory began in the late seventies with the design of the First Spacelab Mission SL-1. Its Material Science Double Rack was the first payload element to carry its own tri-axial acceleration package. Even though incapable for any frequency analysis, the data provided a wealth of novel information for optimal experiment and hardware design and operations for missions to come. Theoretical investigations under ESA contract demonstrated the significance of the detailed knowledge of micro-g data for a thorough experiment analysis. They especially revealed the high sensitivity of numerous phenomena to low frequency acceleration. Accordingly, the payloads of the Spacelab missions D-1 and D-2 were furnished with state-of-the-art detection systems to ensure frequency analysis between 0.1 and 100 Hz. The Microgravity Measurement Assembly (MMA) of D-2 was a centralized system comprising fixed installed as well as mobile tri-axial packages showing real-time data processing and transmission to ground. ESA's free flyer EURECA carried a system for continuous measurement over the entire mission. All EURECA subsystems and experimental facilities had to meet tough requirements defining the upper acceleration limits. In a French/Russion cooperation, CNES developed a mi crogravity detection system for analyzing the Mir space station micro-g-environment for the first time. An approach to get access to low frequency acceleration between 0 and 0.02 Hz will be realized by QSAM (Quasi-steady Acceleration Measurement) on IML-2, complementary to the NASA system Spacelab Acceleration Measurement System SAMS. A second flight of QSAM is planned for the Russian free flyer FOTON.

H Hamacher

A transport-based framework for solidification cracking in Ni-based superalloys processed by laser powder bed fusion

Solidification cracking remains a persistent barrier to laser powder bed fusion (LPBF) processing of solid-solution-strengthened (SSS) Ni-based superalloys and is commonly attributed to carbide formation, liquation-type failure, or elemental segregation. In this work, the cracking behavior of three SSS Ni-based superalloys—Inconel 625 (625), Inconel 617 (617), and Haynes 230 (230)—is examined under comparable LPBF conditions to evaluate the origins of their cracking susceptibility. Carbides were present in both 625 and 230, yet cracking behavior differed significantly. MC-type carbides in 625 remain discrete and preserve liquid connectivity, whereas Cr-rich M23C6 carbides in 230 form at cellular triple junctions that bottleneck the interdendritic liquid network, influencing cracking through liquid connectivity rather than as an independent cause. Alloy 617 exhibited anomalous segregation without resolvable secondary phases yet cracked mildly, indicating that extensive carbide formation is not a prerequisite for cracking. To rationalize these observations, a transport-limited framework is proposed in which cracking occurs when terminal-liquid feeding cannot accommodate solidification-induced strain; among the mechanisms evaluated, this framework is most consistent with the physical constraints imposed by LPBF solidification. Transport-based crack-susceptibility indexes incorporating permeability, viscosity, and solidification kinetics distinguish the alloy hierarchy; permeability ratios Krat increased from approximately 7 (625) to 11.5 (617) and 14.5 (230), with corresponding increases in the μ-weighted mushy zone risk index (CSIMZRM). These results are consistent with transport-limited liquid feeding as a rate-limiting contributor to solidification cracking in LPBF-processed SSS Ni-based superalloys, providing a physically grounded basis for alloy and process design.

Hyer, Holden [ORNL] (ORCID:0000000343915561)