Protocol for Determining Actual Flow Rate in FTWC Duct Systems

This paper is intended to document the theory and methods to determine the actual flow rate in the exhaust system used to ventilate the Flanged Tritium Waste Containers based on realtime instrument readings. Section 1 provides introductory and background material; Section 2 details the various correction factors used to adjust flow readings for ambient air pressure and temperature and other operational parameters. Section 3 provides guidance on implementing this process during venting operations, and Section 4 provides supporting documentation and also a field checklist that can be used by personnel during venting. For Revision 1, a summary of editorial changes made to the paper was added as Section 4.4, as well as a section documenting peer review (Section 4.5).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Analysis of a Membrane-based Ionic Liquid Desiccant (ILD) Dehumidifier

Air dehumidification through cooling is an energy-intensive process, which consumes about 20-40% of the overall energy for air-conditioning. Liquid desiccant dehumidification can separate dehumidification from space cooling and has potential to improve the cooling efficiency and reduce the overall energy consumption for air-conditioning. However, the drawbacks such as liquid carryover and corrosion, membrane contamination and blocking, limit its application. To eliminate these problems, a new dehumidifier using nonporous membrane and ionic liquid desiccant (ILD) was developed. The dehumidification performance of the new dehumidifier was characterized through a series of lab tests. Test results indicate that the new dehumidifier can achieve a moisture removal rate up to 180.3 g/h and a dehumidification effectiveness up to 12.7%. A parametric study found that the dehumidification performance is sensitive to the flowrates of the air and the ILD solution. A higher mass flow ratio between the ILD solution and the air could result in better dehumidification performance.

Wang, Lingshi↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

Roles of Mn and Co in the Air Synthesizability of Layered Oxide Cathodes for Lithium-Based Batteries

High-nickel layered oxides (LiNi 1-x-y Mn x Co y O 2 ) are the prevailing cathode materials for high-energy-density lithium-based batteries, but they are plagued with deleterious surface air instabilities stemming from residual lithium formation. These issues severely hinder mass production as cathode calcination is limited to a flowing oxygen atmosphere, which entails high manufacturing costs as opposed to simpler and more economical air calcination. Here, while higher Ni contents are known to worsen air instabilities, the influence of Mn and Co contents on impacting these phenomena are less elucidated. We herein present the synthesis in ambient air and flowing oxygen atmospheres of three cathode variants with the same Ni contents, but varying Mn and Co contents: LiNi 0.7 Mn 0.3 O 2 , LiNi 0.7 Mn 0.15 Co 0.15 O 2 , and LiNi 0.7 Co 0.3 O 2 . It is found that the critical parameter influencing the air stability of the cathodes is the average Ni oxidation state, which is greatly dependent on the Mn and Co contents. Substitution of Mn for Ni drives down the Ni oxidation state as Mn exists as Mn4 + and reduces surface residual lithium formation, which vastly improves the overall air stability and, therefore, the synthesizability in air, but with a penalty of lowered capacity. In contrast, substitution of Co for Ni maintains Ni 3+ as Co exists as Co 3+ , offering increased initial capacity, but worsens the air stability and cyclability as the driving force for residual lithium formation and surface reactivity is increased.

25 ENERGY STORAGE↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

Non-destructive evaluation of specific surface area of porous powder systems using experimental and virtual air permeametry

The correlation of flow-permeable surface area (FSSA) of porous initiator powder to its performance is well-established. More specifically, with age, such powders tend to coarsen (i.e., lose surface area), with an accompanying deterioration in performance. Commercially available permeametry apparatuses, such as that from Fisher Scientific or a more modern version from Micromeritics suffers from a few drawbacks, including: (1) the need to work with a fixed mass equivalent of 1 cm 3 of solid material; (2) the need to re-compact the material to monitor aging effects (which can introduce unwanted errors in the derived results); (3) a superfluous design that involves a reference plug, and for the older Fisher Scientific model, the need to eyeball water meniscus height that can lead to inaccuracies; (4) calibrated and tested only for samples packed in cylindrical geometries.

36 MATERIALS SCIENCE↗

CISCC Countermeasures for Spent Fuel Canisters in Concrete Casks

Aging management of spent fuel is an important issue worldwide. Chloride-induced stress corrosion cracking (CISCC) of welded canisters is particularly important for concrete casks, where it occurs in response to a combination of environmental, material, and residual stress factors. In this paper, we introduce a countermeasure to prevent the occurrence of CISCC by adjusting the flow rate of the cooling air into the concrete cask so that the canister surface temperature does not decrease below 100°C, which is a conservative deliquesce temperature threshold for CISCC occurrence. The flow adjustment device was installed in a cask model, and two tests were conducted under the heat rate conditions corresponding to those of an actual canister. In the first test, the device was operated under a condition where the canister surface temperature was below 100°C to verify whether it could increase the canister surface temperature to above 100°C. In the second test, the heat rate was decreased from a state where the canister surface temperature was above 100°C, to verify whether the device could maintain the canister surface temperature above 100°C. Good results were obtained in both cases. However, in the case of a low decay heat rate of spent fuel after extended dry storage, the temperature of the canister surface may decrease below 100°C even if no air supply is provided. Therefore, in this case, it may be necessary to take measures such as blocking air outlets.

Takeda, Hirofumi↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An effective air–liquid contactor for CO 2 direct air capture using aqueous solvents

Here, the development of a cost-effective, corrosion resistant, high-flux direct air capture (HiDAC) contactor for a solvent-based direct air capture (DAC) process is reported. Literature technoeconomic analyses suggest that the air–liquid contactor can cost over 20 % of the overall DAC plant’s annualized capital costs. To bring down the overall cost of DAC, it is imperative that an effective contactor is developed. A hybrid contactor consisting of a commercial polyvinylchloride structured packing enhanced with stainless-steel 410 random packing has been developed to provide a high surface area for air–liquid contact. The contactor geometry, wettability, corrosion resistance, pressure drop, along with its CO 2 uptake efficiency, CO 2 uptake rates, and extended loading potential using potassium sarcosinate solutions are investigated. Results show that the HiDAC contactor has a relatively high specific surface area (885 m 2 /m 3 ), which allows for CO 2 uptake efficiencies of up to 75 % and capture rates of up to 550 g of CO 2 per day for a 0.3 × 0.25 × 0.3 m contactor. The contactor also exhibits high levels of wettability and corrosion resistance with amino acid-based DAC solvents. A CO 2 uptake model was developed, and modeling results are compared to experimental data to simulate and predict the performance of the contactor in a DAC process using potassium sarcosinate solvent. The system’s overall mass transfer coefficient and theoretical pressure drop were also calculated, and these results were compared to DAC data found in literature. The results presented indicate that the HiDAC contactor is well suited for DAC due to its high specific surface area, resistance to corrosion, and high degree of wettability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"

This data package contains the associated data and scripts for Nagamoto, E., Ombadi, M., Ciulla, F. et al. Widespread drought-driven declines in streamflows and water quality in the Upper Colorado River Basin during 1998-2022. Commun Earth Environ 7, 734 (2026). https://doi.org/10.1038/s43247-026-03890-5. This purpose of this study was to investigate the impact of the 21st century drought on water quantity and quality at catchments throughout the Upper Colorado River Basin (UCRB). We used stream flow, water temperature, specific conductance, air temperature, precipitation, and catchment attribute data for over 200 sites in the UCRB, collected from the National Water Information System using Basin3D (Varadharajan, 2023), GAGESII (Falcone, 2010), and the Google Earth Engine. We identified years of severe drought between 1998 and 2022 using the Standardized Precipitation Evaporation Index (SPEI), then calculated the relative change percentage of the stream flow, water temperature, and specific conductance from drought versus non-drought years. We used the attribute information from GAGESII to investigate what physical traits of catchments are associated streamflow vulnerability (greater relative change) or resilience to drought. We used land cover data from the National Land Cover Database (USGS, 2024) to assess any changes to physical attributes that may not be represented in the static attributes information in GAGESII. To increase data availability, we modeled stream temperature using methods from Willard, 2023. While the study period is water years 1998 to 2022, the raw water quantity and quality data extends to 1950 and the meteorological data extends to 1980. The data and code can be downloaded via the UCRB_drought.zip. Within the zip, the files are organized as follows: - INPUTS: Contains all input data used in UCRB_Drought_Workflow.ipynb - OUTPUTS: Contains all intermediate data created from UCRB_Drought_Workflow.ipynb as well as final products including the calculated Standardized Evapotranspiration Index (SPEI) - climatic_variables: The code used to collect meteorologic data from Google Earth Engine - feature_importance: The code used for the catchment attributes analysis - preprocessing: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - pyeto: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - calculations: Code used in UCRB_Drought_Workflow_Impacts.ipynb - plotting: Code used in UCRB_Drought_Workflow_Impacts.ipynb - README.md - UCRB_Drought_Workflow_Preprocessing.ipynb: The code used to prep raw data for the analysis - UCRB_Drought_Workflow_Impact.ipynb: The code which uses the prepped raw data for analysis, and plots all figures - requirements_ucrb-drought_v2.yml: The requirements file to create a virtual environment and Jupyter Lab kernel to run the code The INPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_RAW" folder contains raw data for streamflow, water temperature, and specific conductance in a ".h5" file. The "NLCD_RAW" folder contains ".csv" files with annual land cover percentages for counties within the UCRB. The "MET_RAW" folder contains a ".csv" file with monthly meteorological data (air temperature and precipitation) for the sites in the UCRB which was obtained from code in the climatic_variables folder. The "GAGESII" folder contains ".csv" files with physical catchment attribute variables for catchments across the country. The "WT_LSTM_data" folder contains ".csv" files with calculated WT (Willard, 2023) and the associated RMSEs. The "Upper_Colorado_River_Basin_Boundary" folder contains geographic data including a shapefile for plotting in the UCRB_Drought_Workflow.ipynb. The "RESERVOIRS_RAW" folder contains ".csv" files for each reservoir in the UCRB with daily reservoir storage. There are also two files in the INPUTS folder that have combined reservoir storage data and reservoir metadata. The OUTPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_data" folder contains a folder "Water_year" with the associated cleaned data, metadata, and data availability information in ".csv" files, a folder "Median_Relchange" with the relative change comparing drought to non-drought years in ".csv" files, and a folder "Peak95_Min5_Relchange" that has ".csv" files for the relative change in peak (95th %) and minimum (5th %) variables. The "NLCD_data" folder contains the difference in land cover from the beginning to end of the study period and the percentage of the county that is within UCRB bounds can be found in Nagamoto et al (2025)). The "MET_data" folder contains separated monthly air temperature and precipitation data and the calculated PET in ".csv" files. The "SPEI_data" folder contains ".csv" files with calculated SPEI values (one restricted to the study period and the other with information from the entire MET data period). The "Paper_Tables" folder contains two ".csv" files containing site information and data availability and information about the GAGESII trait aggregated categories. The base directory includes the file “flmd.csv” for a list and description of all files and the file “dd.csv” for data dictionaries. Scripts for preprocessing, analysis, and figure generation are located in the associated GitHub repository found at [https://github.com/iNAIADS/drought-impacts/tree/develop/UCRB-drought]. UPDATE 1: Title and code file updated to match submitted manuscript 10-15-2025. UPDATE 2: Code and data files updated to match revised manuscript 3-4-2026. UPDATE 3: Code and data files updated to match revised manuscript 6-7-2026. ** NOTE: DD and FLMD have not been updated yet. UPDATE 4: Added associated Manuscript information and DD and FLMD have been updated. To cite this code, please use the following BibTeX: @misc{nagamoto2025drought, author = {Emily Nagamoto and Fabio Ciulla and Mohammad Ombadi and Jared Willard and Rosemary Carroll and Charuleka Varadharajan}, title = {Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"}, year = {2025}, doi = {10.15485/2551894}, publisher = {ESS-DIVE Repository}, url = {https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2551894} }

54 ENVIRONMENTAL SCIENCES↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A nudged hybrid analysis and modeling approach for realtime wake-vortex transport and decay prediction

Here, we put forth a long short-term memory (LSTM) nudging framework for the enhancement of reduced order models (ROMs) of fluid flows utilizing noisy measurements for air traffic improvements. Toward emerging applications of digital twins in aviation, the proposed approach allows for constructing a realtime predictive tool for wake-vortex transport and decay systems. We build on the fact that in realistic application, there are uncertainties in initial and boundary conditions, model parameters, as well as measurements. Moreover, conventional nonlinear ROMs based on Galerkin projection (GROMs) suffer from imperfection and solution instabilities, especially for advection-dominated flows with slow decay in the Kolmogorov n-width. In the presented LSTM nudging (LSTM-N) approach, we fuse forecasts from a combination of imperfect GROM and uncertain state estimates, with sparse Eulerian sensor measurements to provide more reliable predictions in a dynamical data assimilation framework. We illustrate our concept by solving the two-dimensional vorticity transport equation. We investigate the effects of measurements noise and state estimate uncertainty on the performance of the LSTM-N behavior. We also demonstrate that it can sufficiently handle different levels of temporal and spatial measurement sparsity, and offer a huge potential in developing next-generation digital twin technologies for aerospace applications.

42 ENGINEERING↗

Adsorption-based membranes for air separation using transition metal oxides

In this work, we use computational modeling to examine the viability of adsorption-based pore-flow membranes for separating gases when a purely size-based separation strategy is ineffective. Using molecular dynamics simulations of O 2 and N 2 , we model permeation through a nanoporous graphene membrane. Permeation is assumed to follow a five-step adsorption-based pathway, with desorption being the rate-limiting step. Using this model, we observe increased selectivity between O 2 and N 2 , resulting from increased adsorption energy differences. We explore the limits of this strategy, providing an initial set of constraints that need to be satisfied to allow for selectivity. Finally, we provide a preliminary exploration of some transition metal oxides that appear to satisfy those conditions. Using density functional theory calculations, we confirm that these oxides possess adsorption energies needed to operate as adsorption-based pore-flow membranes. These adsorption energies provide a suitable motivation to examine adsorption-based pore-flow membranes as a viable option for air separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling ammonia-fueled co-flow dual-channel protonic-ceramic fuel cells

This paper reports the model development for a dual-channel protonic-ceramic fuel cell (PCFC) operating on ammonia fuel. The model considers the coupled interactions of several physical and chemical processes, including three-dimensional heat conduction within the bipolar plates and the membrane-electrode assembly (MEA), one-dimensional flow within the fuel and air channels, detailed heterogeneous catalytic reactions within the porous composite anode structure, Butler–Volmer representation of the charge-transfer chemistry, and Nernst–Planck transport of three charged defects (protons, oxygen vacancies, and small polarons) within the dense electrolyte membrane. The membrane-electrode assembly is composed of a Ni-BCZYYb (BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ ) anode, a BCZYYb electrolyte membrane, and a BCFZY (BaCo 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3-δ ) cathode. Chemical and physical parameters for the MEA model are established using previously published button-cell data. One aspect of the study is to investigate the partial ammonia decomposition upstream of the fuel cell. Such fuel cracking increases the H 2 content of the fuel entering the PCFC, which may have benefits. However, endothermic ammonia pyrolysis within the composite anode structure assists with thermal control of the cell. The dual-channel model can be considered as the unit cell of a full fuel-cell stack.

25 ENERGY STORAGE↗

Measurements of He-Ar, He-N 2 , and He-air thermal creep slip and accommodation coefficients at high temperatures

Understanding gas flows in capillaries has many applications in modeling the transport of gases in nano-structured, porous, or fractured media. A network of capillaries can often approximate these media, and also information on gas-surface interactions obtained from capillary experiments can be used for modeling flows in these media. Experimental data on flows of different mixtures of He-Ar, He-N 2 , and He-air in the slip regime and in stainless steel capillaries at high temperatures were obtained by using a two-bulb apparatus. An accurate expression for the thermal creep slip coefficients with the Lennard-Jones potential parameters and diffuse-specular reflection gas-surface interaction conditions were then used to obtain the accommodation coefficients for the different gases. The experimental data are best described with values of accommodation coefficients in the range of 0.1–0.3 for He and 0.5–1.0 for Ar, N 2 , and air. Further, the use of values in this range is suggested for modeling gaseous flows in capillaries and nano-structured, porous, or fractured media if other direct measured values for a particular medium are unavailable.

42 ENGINEERING↗

Integration and validation of some modules for modelling of high-speed chemically reactive flows in two-phase gas-droplet mixtures

Three modules are integrated into the built-in OpenFOAM rhoCentralFoam solver towards accurate and efficient modelling of high-speed chemically reactive flows in two-phase gas-droplet mixtures within the OpenFOAM 10.0 framework. The first module is the mixture-averaged diffusion model. The second module is the built-in OpenFOAM Lagrangian solver coupled with optimised droplet drag coefficient and convective heat transfer coefficient sub-models. The last module is a sparse stiff chemistry solver based on dynamic adaptive hybrid integration (AHI-S). The optimised droplet sub-models are first verified in correct implementation for subsequent simulations in this work. Further, they show good accuracy against experimental and analytical data in the modelling of ammonia droplet acceleration and cooling in the flowing and/or low-temperature air. The accuracy and efficiency gains related to the mixture-averaged diffusion model and the AHI-S chemistry solver are examined by simulating 1-D detonation propagation in ammonia droplet-free/laden ammoniaoxygen mixtures. Numerical results of detonation propagation speed, gaseous temperature, density, and species distributions around the induction zone show good agreement with experimental data and analytical solutions. Compared to the built-in OpenFOAM diffusion model, the mixture-averaged diffusion model provides different numerical predictions of pulsating instabilities in detonation propagation. It shows better accuracy in depicting the detonation structure within the droplet-free section attributed to improved multi-component diffusion modelling. Compared to the built-in OpenFOAM solver EulerImplicit (backward Euler), the AHI-S chemistry solver reduces the computational cost by around 50%. It achieves satisfactory accuracy in calculating detonation propagation speed within the droplet-free section with the optimal efficiency when the safety factor, β, equals 0.5.

42 ENGINEERING↗

Sensitivity Analysis of an Electrospray Dehumidification System

Electrically enhanced condensation achieved by an electrospray system can enhance dehumidification in HVAC applications if successfully scaled up. The first step towards scale-up is identifying critical design and operating parameters that significantly impact dehumidification for the electrospray system. Sensitivity analysis is one approach for identifying critical parameters. This paper presents a methodology that can efficiently perform quantitative sensitivity analysis on a computationally expensive high fidelity simulation model, which is a computational fluid dynamics (CFD) model of the electrospray system. The methodology employs surrogate modeling and Sobol sensitivity analysis. We estimate the main and total effect Sobol sensitivity indices of four operating parameters of the electrospray system. The results reveal that the most important parameter is the size of the sprayed droplets, followed by the volumetric flow rate of the bulk air and injected water in the system. The water injection velocity of the spray was found to have little to no impact on dehumidification.

Young, David↗