Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Kauhale 'O Kipapa: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Findings show hybrid PV and battery systems, supplemented by small wind turbines, offer cost-effective, resilient solutions. This work supports enhanced energy independence and disaster preparedness for the community.

Quiroz, Jimmy Edward [Sandia National Laboratories↗

Redox Bulk Energy Storage System Study, Volume 1

Opportunities were found for electrochemical energy storage devices in the U.S. electric utility industry. Application requirements for these devices were defined, including techno-economic factors. A new device, the Redox storage battery was analyzed. The Redox battery features a decoupling of energy storage and power conversion functions. General computer methods were developed to simulate Redox system operations. These studies showed that the Redox system is potentially attractive if certain performance goals can be achieved. Pathways for reducing the cost of the Redox system were identified.

Ciprios, G.↗

Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios

This presentation discusses the fourth report in NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This report describes the expanded capabilities of the Distributed Generation Market Demand (dGen) model to analyze the economics of distributed (behind-the-meter) PV paired with battery storage systems and presents projections of adoption for the contiguous United States out to 2050 under a range of scenarios. These scenarios use technology cost and performance assumptions consistent with the National Renewable Energy Laboratory’s 2020 Standard Scenarios paired with updated battery cost projections and existing policies. Additional scenarios evaluate sensitivities to the value of backup power and DER compensation mechanisms, collectively characterizing the future potential for behind-the-meter storage and identifying key drivers of adoption. Adoption projections of DER and battery storage at high spatial and temporal resolution, as presented in this report, can enable informed planning of technical infrastructure that can help planners capture the benefits and mitigate challenges to support the ongoing trend toward distributed electricity generation.

backup power↗

The GSFC Battery Workshop

The proceedings of a conference on electric storage batteries are presented. The subjects discussed include the following: (1) a low cost/standardization program, (2) test and flight experience, (3) materials and cell components, and (4) new developments in the nickel/hydrogen system. The application of selected batteries in specific space vehicles is examined.

Source record↗

Coordinated Wind Power Plant and Battery Control for Active Power Services

This article considers joint active power control of wind turbines and battery storage to follow a plant-level power reference signal. The joint control dynamically curtails the energy from a subset of the wind turbines and stores or withdraws energy from the battery to meet the power reference setpoint while accounting for wind plant aerodynamic interactions, such as wake losses. As a use case, we study the performance of the controller in maintaining a constant power output over hourly periods. A wind plant operating in this way would rely much less on other grid resources to meet its contractual agreements, thereby improving grid reliability, especially in grids with high penetration of wind and solar generation. We compare the operation of the wind plant under joint active power control to standard power-maximizing control with battery support. We present an analysis of the performance of the control system architecture. To study the impact of the battery size on performance, we simulate a 50-MW wind plant supported by batteries ranging from 8 to 64?MWh. We then evaluate the over and undergeneration penalties incurred by the plant during the simulation period.

17 WIND ENERGY↗

Hybrid Grid-Renewable Strategies for Green Steel Production under Electricity Market Uncertainty

Volatility in grid spot prices is expected to rise with climate change-driven demand pressures and the intermittency of renewable generation. This volatility poses financial risks for green hydrogen-based steel production. The Direct Reduced Iron− Electric Arc Furnace (H 2 -DRI-EAF) is a promising pathway to decarbonize steel, which accounts for ∼8% of global GHG emissions. This study assesses how increased grid spot price volatility influences the optimal sizing and operation of H2-DRIEAF plants under three operational scenarios: grid-connected, fully behind-the-meter (islanded), and mixed-mode (semi-islanded). Our analysis identifies the semi-islanded configuration as the most cost-effective solution, achieving a Levelized Cost of Steel (LCOS) 10−35% lower than sourcing energy solely from the grid. Modeling also shows hydrogen storage or selective electricity purchases at high prices (>$1000/MWh) generally outperform battery storage, except under extreme volatility. Additionally, the study explores cost reduction strategies to strengthen the economic viability and sustainability of green steel production.

Batteries↗

The Challenges of Modeling Distributed Energy Resources (DERs) as Blackstart Resources and for Volt-VAR Optimality

Modeling, testing and instituting Distributed Energy Resources (DERs) as Blackstart Resoucrces presents several challenges due to the fundamental differences between traditional black start resources (e.g., large generators) versus DERs like solar PV systems with battery storage. This paper addresses some of these key challenges. These include intermittency of coordinating DERs to provide continuous power during a black start event, especially during extended periods of cloud cover or when battery energy storage is depleted. This paper additionally addresses the collapsing voltage and stability control challenges specific to maintaining bulk power system stability during black start synchronization These physical and engineering limitations require careful engineering design, modeling and engineering to ensure that DERs can support critical loads and substations during black start events. A variety of additional challenges also exist. Additionally, there are challenges associated with feeder location and low voltage secondary system impacts on DER functions and settings. We compare typical functions and settings for DERs for power factor control and correction. We also demonstrate how voltag control via Volta-VAR power factor correction can be done

Mukherjee, Srijib↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Expanding NREL's Advanced Research on Integrated Energy Systems (ARIES) Capabilities

NREL's Integrated Energy Pathways vision represents a transformed, future integrated energy system that is more affordable, clean, secure, and resilient than today. Key to this vision is the unique Advanced Research on Integrated Energy Systems (ARIES) research platform. With a focus on advancing modern grid infrastructure, making investments in energy efficiency building technology research, and innovating battery storage and much more, the unique ARIES research platform can be used to accelerate the integration of new technologies into a modern grid.

advanced research↗

Synergies Between Building-Sited Batteries and Thermal Energy Storage

As renewable penetration increases, there is a greater need for energy storage systems located at buildings. This storage can include batteries, which directly shift the metered load, or thermal energy storage, which shifts thermal-driven electric loads like air conditioning. This presentation covers modeling results of the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. It also shows how battery storage can expand the usefulness of thermal energy storage for electric load shaving, and how thermal storage can lower the cost of the overall storage system and extend battery lifetime by reducing cycling.

batteries↗

A Review of Sandia Energy Storage Research Capabilities and Opportunities (2020 to 2030)

Large-scale integration of energy storage on the electric grid will be essential to enabling greater penetration of intermittent renewable energy sources, modernizing the grid for increased flexibility security, reliability, and resilience, and enabling cleaner forms of transportation. The purpose of this report is to summarize Sandia's research and capabilities in energy storage and to provide a preliminary roadmap for future efforts in this area that can address the ongoing program needs of DOE and the nation. Mission and vision statements are first presented followed by an overview of the organizational structure at Sandia that provides support and activities in energy storage. Then, a summary of Sandia's energy storage capabilities is presented by technology, including battery storage and materials, power conversion and electronics, subsurface-based energy storage, thermal/thermochemical energy storage, hydrogen storage, data analytics/systems optimization/controls, safety of energy storage systems, and testing/demonstrations/model validation. A summary of identified gaps and needs is also presented for each technology and capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nongassing nickel-cadmium battery electrodes and cells

The failure of nickel-cadmium storage batteries due to severe gassing during charging is discussed. In order to increase the life of such cells, nongassing positive and negative electrodes are used. The gassing characteristics of nickel electrodes were evaluated as a function of their loading, charge rate, and charge temperature.

Luksha, E.↗

Thermal energy storage for the Stirling engine powered automobile

A thermal energy storage (TES) system developed for use with the Stirling engine as an automotive power system has gravimetric and volumetric storage densities which are competitive with electric battery storage systems, meets all operational requirements for a practical vehicle, and can be packaged in compact sized automobiles with minimum impact on passenger and freight volume. The TES/Stirling system is the only storage approach for direct use of combustion heat from fuel sources not suitable for direct transport and use on the vehicle. The particular concept described is also useful for a dual mode TES/liquid fuel system in which the TES (recharged from an external energy source) is used for short duration trips (approximately 10 miles or less) and liquid fuel carried on board the vehicle used for long duration trips. The dual mode approach offers the potential of 50 percent savings in the consumption of premium liquid fuels for automotive propulsion in the United States.

Morgan, D. T.↗

Ampere-Hour Meter For Rechargeable Battery

Low-power analog/digital electronic circuit meters discharge of storage battery in ampere-hours. By metering discharge, one obtains indication of state of charge of battery and avoids unnecessary recharging, maintaining capacity of battery and prolonging life. Because of its small size and low power consumption, useful in such applications as portable video cameras, communication equipment on boats, portable audio equipment, and portable medical equipment.

Tripp, John S.↗

Disorder Dynamics in Battery Nanoparticles During Phase Transitions Revealed by Operando Single-Particle Diffraction

Structural and ion-ordering phase transitions limit the viability of sodium-ion intercalation materials in grid scale battery storage by reducing their lifetime. However, the combination of phenomena in nanoparticulate electrodes creates complex behavior that is difficult to investigate, especially on the single-nanoparticle scale under operating conditions. In this work, operando single-particle X-ray diffraction (oSP-XRD) is used to observe single-particle rotation, interlayer spacing, and layer misorientation in a functional sodium-ion battery. oSP-XRD is applied to Na 2/3 [Ni 1/3 Mn 2/3 ]O 2 , an archetypal P2-type sodium-ion-positive electrode material with the notorious P2-O2 phase transition induced by sodium (de)intercalation. Here, it is found that during sodium extraction, the misorientation of crystalline layers inside individual particles increases before the layers suddenly align just prior to the P2-O2 transition. The increase in the long-range order coincides with an additional voltage plateau signifying a phase transition prior to the P2-O2 transition. To explain the layer alignment, a model for the phase evolution is proposed that includes a transition from localized to correlated Jahn-Teller distortions. The model is anticipated to guide further characterization and engineering of sodium-ion intercalation materials with P2-O2 type transitions. oSP-XRD, therefore, opens a powerful avenue for revealing complex phase behavior in heterogeneous nanoparticulate systems.

25 ENERGY STORAGE↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

Fact sheet describes how the Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid to ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

battery storage↗

Long duration battery sizing, siting, and operation under wildfire risk using progressive hedging

Battery sizing and siting problems are computationally challenging due to the need to make long-term planning decisions that are cognizant of short-term operational decisions. This paper considers sizing, siting, and operating batteries in a power grid to maximize their benefits, including price arbitrage and load shed mitigation, during both normal operations and periods with high wildfire ignition risk. Here we formulate a multi-scenario optimization problem for long duration battery storage while considering the possibility of load shedding during Public Safety Power Shutoff (PSPS) events that de-energize lines to mitigate severe wildfire ignition risk. To enable a computationally scalable solution of this problem with many scenarios of wildfire risk and power injection variability, we develop a customized temporal decomposition method based on a progressive hedging framework. Extending traditional progressive hedging techniques, we consider coupling in both placement variables across all scenarios and state-of-charge variables at temporal boundaries. This enforces consistency across scenarios while enabling parallel computations despite both spatial and temporal coupling. The proposed decomposition facilitates efficient and scalable modeling of a full year of hourly operational decisions to inform the sizing and siting of batteries. With this decomposition, we model a year of hourly operational decisions to inform optimal battery placement for a 240-bus WECC model in under 70 min of wall-clock time.

25 ENERGY STORAGE↗