Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHARGE-COUPLED DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

CCD Star Tracker Experience -- Key Results from Astro 1 flight

Charge-coupled devices (CCDs) have now flown successfully in a number of space scientific and engineering instruments, and have rapidly become the preferred technology for most imaging applications. One of their earliest planned applications in space was in the precision (subarcsecond) star tracker for the Astro series of UV missions.

Astro↗

Application of the Active Pixel Sensor Concept to Guidance and Navigation

Charge-coupled devices (CCDs) have been used extensively in the past in star trackers and fine guidance systems. A new technology, the active pixel sensor, is a possible successor to CCDs. This technology potentially features the same sensitivity and performance of the CCD with additional improvements. These improvements include random access capability, easy window-of-interest readout, non-destructive readout for signal-to-noise improvement, high radiation tolerance, simplified clocking voltages, and easy integration with other on-chip signal processing circuitry. The state-of-the-art of this emerging technology and its potential application to guidance and navigation systems is discussed.

Eisenman, Allan R.↗

A broadband superconducting detector suitable for use in large arrays

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths.

Crogenic↗

Solid state television camera

The design, fabrication, and tests of a solid state television camera using a new charge-coupled imaging device are reported. An RCA charge-coupled device arranged in a 512 by 320 format and directly compatible with EIA format standards was the sensor selected. This is a three-phase, sealed surface-channel array that has 163,840 sensor elements, which employs a vertical frame transfer system for image readout. Included are test results of the complete camera system, circuit description and changes to such circuits as a result of integration and test, maintenance and operation section, recommendations to improve the camera system, and a complete set of electrical and mechanical drawing sketches.

Source record↗

Development of InSb charge-coupled infrared imaging devices: Linear imager

The following results were accomplished in the development of charge coupled infrared imaging devices: (1) a four-phase overlapping gate with 9 transfers (2-bits) and 1.0-mil gate lengths was successfully operated, (2) the measured transfer efficiency of 0.975 for this device is in excellent agreement with predictions for the reduced gate length device, (3) mask revisions of the channel stop metal on the 8582 mask have been carried out with the result being a large increase in the dc yield of the tested devices, (4) partial optical sensitivity to chopped blackbody radiation was observed for an 8582 9-bit imager, (5) analytical consideration of the modulation transfer function degradation caused by transfer inefficiency in the CCD registers was presented, and (6) for larger array lengths or for the insertion of isolated bits between sensors, improvements in InSb fabrication technology with corresponding decrease in the interface state density are required.

Phillips, J. D.↗

Further development of an indium antimonide (InSb)Charge-Coupled Infrared Imaging Device (CCIRID), 20-element linear imager

Problems encountered in the development of an indium antimonide charge coupled device for infrared imaging and real time signal processing on the focal plane are summarized. A new generation chip is described which contains, 2, 4, and 20-element imagers, a 4-element TDI array, a monolithic gated charge integrator, and test devices. A system study of a future LANDSAT sensor system configured around an InSb TDi array is considered.

Source record↗

Charge-coupled differential amplifier

Device solves problem of differential voltage gain in sampled-data metal-oxide semiconductor, producing gain at any frequency compatible with CCD operation, with low noise, low power, good linearity, and high stability.

Hewes, C. R.↗

Development of a Shuttle Infrared Telescope Facility /SIRTF/ fine guidance sensor

Fine guidance technology development for the Shuttle Infrared Telescope Facility (SIRTF) centers upon the use of a single multiple-star-tracking sensor to provide the position information necessary to produce three-axis attitude control signals for precision payload pointing. The effort described in this paper is concerned with the development of a fine guidance sensor that employs a high-density charge-coupled imaging device for producing position information signals by using star fields. Multiple star position information produces three-axis position error signals that are used to update inertial reference gyros. The sensor employs advanced position interpolation algorithms to enhance field-of-view resolution and to correct for optical aberrations inherent in spatially chopped star images resulting from the telescope's movable secondary mirror. Operation of the sensor is under the control of a high-performance microcomputer that provides both autonomy and flexibility in a guidance application.

Salomon, P. M.↗

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Electron-Induced Displacement Damage Effects in CCDs

We compare differences in parametric degradation for CCDs irradiated to the same displacement damage dose with 10-MeV and 50-MeV electrons. Charge transfer efficiency degradation was observed to not scale with NIEL for small signals.

Juno Mission↗

Assessment of Image Sensor Technology for Future NASA Missions

An assessment of solid-state UV/visible image sensor technology for future NASA missions is presented. The paper will attempt to summarize the state of the art in image sensor technology in the United States, Canada, Japan, and Europe. The state of the art and future trends will be compared to a forecast of future NASA needs in scientific image sensors for planetary exploration, earth science, astrophysics, and spacecraft systems such as star trackers and optical communications.

solid-state↗

Cassini Stellar Reference Unit: Performance Test Approach and Results

The Cassini Stellar Reference Unit (SRU) is the prime attitude determination sensor on the Cassini spacecraft...To ensure that the SRU will operate within specification for the entire mission, an extensive test program has been undertaken to characterize the SRU performance prior to launch and to quantify any expected performance degradation. Results from several eomplimentary test programs are presented and compared with pre-test performance predictions.

star↗

Improved Charge-Coupled Imager For X Rays

Device proposed to improve imaging of x rays. Features thin layer of oxide in virtual phase to increase quantum efficiency and depletion layer nearly as thick as epitaxial silicon layer to increase resolution. Applications include imaging spectrometers for x-ray astronomy, investigations of plasmas, and x-ray crystallography.

Wadsworth, Mark↗

Indium antimonide infrared CCD linear imaging arrays with on-chip preprocessing

A description is presented of the fabrication of a new InSb CCD chip based on an improved process which eliminates the limitations inherent with the earlier techniques. This process includes planar junction formation and an aluminum and SiO2 material system which is amenable to state-of-the-art chemical and plasma delineation techniques. Further, the new chip integrates for the first time in monolithic format InSb IR detectors with an InSb CCD. The reported experiments represent the first operation of an InSb infrared CCD array. In addition to fuller characterization of the 20-element charge-coupled infrared imaging device, several factors which influence device performance are currently being addressed. These include surface state density, the CCD output circuit, and storage time (dark current).

Thom, R. D.↗

Physics of Hard Spheres Experiment: Significant and Quantitative Findings Made

Direct examination of atomic interactions is difficult. One powerful approach to visualizing atomic interactions is to study near-index-matched colloidal dispersions of microscopic plastic spheres, which can be probed by visible light. Such spheres interact through hydrodynamic and Brownian forces, but they feel no direct force before an infinite repulsion at contact. Through the microgravity flight of the Physics of Hard Spheres Experiment (PHaSE), researchers have sought a more complete understanding of the entropically driven disorder-order transition in hard-sphere colloidal dispersions. The experiment was conceived by Professors Paul M. Chaikin and William B. Russel of Princeton University. Microgravity was required because, on Earth, index-matched colloidal dispersions often cannot be density matched, resulting in significant settling over the crystallization period. This settling makes them a poor model of the equilibrium atomic system, where the effect of gravity is truly negligible. For this purpose, a customized light-scattering instrument was designed, built, and flown by the NASA Glenn Research Center at Lewis Field on the space shuttle (shuttle missions STS 83 and STS 94). This instrument performed both static and dynamic light scattering, with sample oscillation for determining rheological properties. Scattered light from a 532- nm laser was recorded either by a 10-bit charge-coupled discharge (CCD) camera from a concentric screen covering angles of 0 to 60 or by sensitive avalanche photodiode detectors, which convert the photons into binary data from which two correlators compute autocorrelation functions. The sample cell was driven by a direct-current servomotor to allow sinusoidal oscillation for the measurement of rheological properties. Significant microgravity research findings include the observation of beautiful dendritic crystals, the crystallization of a "glassy phase" sample in microgravity that did not crystallize for over 1 year in 1g (Earth's gravity), and the emergence of face-centered-cubic (FCC) crystals late in the coarsening process (as small crystallites lost particles to the slow ripening of large crystallites). Significant quantitative findings from the microgravity experiments have been developed describing complex interactions among crystallites during the growth process, as concentration fields overlap in the surrounding disordered phase. Time-resolved Bragg scattering under microgravity captures one effect of these interactions quite conclusively for the sample at a volume fraction of 0.528. From the earliest time until the sample is almost fully crystalline, the size and overall crystallinity grow monotonically, but the number of crystallites per unit volume (number density) falls. Apparently nucleation is slower than the loss of crystallites because of the transfer of particles from small to large crystals. Thus, coarsening occurs simultaneously with growth, rather than following the completion of nucleation and growth as is generally assumed. In the same sample, an interesting signature appears in the apparent number density of crystallites and the volume fraction within the crystallites shortly before full crystallinity is reached. A brief upturn in both indicates the creation of more domains of the size of the average crystallite simultaneous with the compression of the crystallites. Only the emergence of dendritic arms offers a reasonable explanation. The arms would be "seen" by the light scattering as separate domains whose smaller radii of curvature would compress the interior phase. In fiscal year 1999, numerous papers, a doctoral dissertation, and the PHaSE final report were produced. Although this flight project has been completed, plans are in place for a follow-on colloid experiment by Chaikin and Russel that employs a light microscope within Glenn's Fluids and Combustion Facility on the International Space Station. PHaSE is providing us with a deeper understanding of the nure of phase transitions. The knowledge derived has added to the understanding of condensed matter. In addition, the burgeoning study of the dynamics of colloidal self-assembly may lead to the development of a range of photonic materials that control the desirable properties of light. Thus, applications of ordered colloidal structures include not only ultrastructure ceramics, but also photonic crystals and photothermal nanosecond light-switching devices. Industries dealing with semiconductors, electro-optics, ceramics, and composites stand to benefit from such advancements.

Doherty, Michael P.↗

Cooled slow-scan performance of a 512 by 320 element charge-coupled imager

A 512 x 320 element charge coupled imager has been fabricated and tested under cooled slow scan conditions to evaluate the device's performance under a variety of long integration and slow scan readout conditions. Operation in a low blooming mode of operation enables the sensor to be exposed with portions of the image heavily overexposed, without those areas spreading into adjacent picture areas. Device design, layout, and operating mode are described, and presents experimental results, including displayed images taken under cooled slow scan operation, are reported.

Rodgers, R. L., III↗