Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Study of Corrosion Behavior of Oil Gathering Facilities with Co{sub 2} Flooding In Low-Permeability Oilfields

Carbon dioxide (CO{sub 2}) gas flooding for enhancement of oil recovery is known to face challenges such as corrosion and scaling of oil-gathering facilities and environmental pollution. The corrosion behavior of the gathering facilities must be studied to select the optimum measures for protecting them from the corrosive effect of CO{sub 2}. Surface corrosion of the separator, a key problem with using CO{sub 2}, is evaluated in the present work. The corrosion characteristics, corrosion rate, and corrosion products in different functional areas of the facility were determined by the weight-loss method, scanning electron microscopy (SEM), and x-ray diffraction (XRD) analysis. The results indicate that pitting corrosion is the main characteristic of Fe-360 A steel facilities and that the average corrosion rate in vulnerable areas can reach 0.1358 mm/yr with formation of Fe{sub 2}O{sub 3} and FeS. The combined effects of contact time and CO{sub 2} volume in conjunction with the activity of sulfate-reducing bacteria influence the corrosion kinetics and mechanism of Fe-360 A steel. The results are of great significance for minimizing corrosion using chemical inhibition and proper selection of materials that come into contact with CO{sub 2}.

36 MATERIALS SCIENCE↗

Effect of chloride content of molten nitrate salt on corrosion of A516 carbon steel.

The corrosion behavior of A516 carbon steel was evaluated to determine the effect of the dissolved chloride content in molten binary Solar Salt. Corrosion tests were conducted in a molten salt consisting of a 60-40 weight ratio of NaNO{sub 3} and KNO{sub 3} at 400{sup o}C and 450{sup o}C for up to 800 hours. Chloride concentrations of 0, 0.5 and 1.0 wt.% were investigated to determine the effect on corrosion of this impurity, which can be present in comparable amounts in commercial grades of the constituent salts. Corrosion rates were determined by descaled weight losses, corrosion morphology was examined by metallographic sectioning, and the types of corrosion products were determined by x-ray diffraction. Corrosion proceeded by uniform surface scaling and no pitting or intergranular corrosion was observed. Corrosion rates increased significantly as the concentration of dissolved chloride in the molten salt increased. The adherence of surface scales, and thus their protective properties, was degraded by dissolved chloride, fostering more rapid corrosion. Magnetite was the only corrosion product formed on the carbon steel specimens, regardless of chloride content or temperature.

36 MATERIALS SCIENCE↗

DETERMINATION OF CORROSION INHIBITOR CRITERIA FOR TYPE III/IIIA TANKS DURING SALT DISSOLUTION OPERATIONS SUMMARY DOCUMENT

Dissolution of salt from Type III/IIIA waste tanks at the Savannah River Site may create solutions with inhibitor concentrations below those currently required (0.6M OH{sup -} and 1.1M OH{sup -} + NO{sub 2}{sup -}) per the Corrosion Control Program for high nitrate salt solutions (5.5 to 8.5M NO{sub 3}{sup -}). An experimental program was conducted to evaluate the corrosion susceptibility of grade A537 carbon steel for waste simulants containing 4.5-8.5M NaNO{sub 3} with maximum inhibitor concentrations of 0.6M NaOH and 0.2M NaNO{sub 2}. These maximum inhibitor concentrations used in this program are at a reduced level from those currently required. Current requirements were initially established for the Types I, II and IV tanks made of A285 carbon steel. The experimental program involved corrosion testing to evaluate the pitting and stress corrosion stress corrosion cracking (SCC) susceptibility of the Type III/IIIA waste tank materials. The program was conducted in two phases; the results of the first phase were reported previously (WSRC-STI-2006-00029). In this second phase, the corrosion specimens were modified to represent the 'as-fabricated' condition of the tank wall, and included specimens with mill scale, ground welds and stress-relief heat treatments. The complete description of the corrosion testing and the results are reported herein. The collective corrosion test results for A537 carbon steel in high nitrate waste simulants (4.5 - 8.5M) with the maximum inhibitor concentrations of 0.6M NaOH and 0.2M NaNO{sub 2} were as follows: (1) In long-term non-polarized U-bend testing, heat treatment, similar to the waste tank stress relief regime, reduced the incidence of cracking over the 18-month test period. Vapor space SCC was found to initiate on non-heat treated U-bend coupons. (2) In polarized U-bend testing, cracking occurred on U-bend coupons that had welds prepared similar to those in the waste tanks, i.e. ground and heat treated. (3) In electrochemical testing, pitting occurred on all coupons independent of heat treatment, inhibitor concentration, temperature, surface preparation, or welding. (4) In slow strain rate testing, cracking occurred on samples tested in solutions containing up to the maximum inhibitor concentration. The primary conclusion derived from this experimental program is that A537 carbon steel exposed to high nitrate (> 5.5M) solutions at inhibitor levels below the current specifications (0.6M OH{sup -} and 1.1M OH{sup -} + NO{sub 2}{sup -}) are susceptible to localized corrosion in the form of pitting and stress corrosion cracking. Long-term storage (e.g., greater than 100 days) of dissolved salt solutions not meeting the current inhibitor specifications for high nitrate salt chemistries in Type III waste tanks shall be avoided. Short term storage (e.g., less than 100 days) at low temperatures (e.g., less than 50 C) in these tanks is permissible for waste removal purposes. The stress relief process reduces the risk of SCC in the Type III waste tanks. On the other hand, the current inhibitor specifications should be strictly followed for the Type I, II and IV waste chemistry to prevent initiation of localized corrosion mechanisms. These tanks were not stress relieved and are more susceptible to SCC.

36 MATERIALS SCIENCE↗

Development of Corrosion Resistant Coatings for Structural Materials for Liquid Fueled Molten Salts Reactors Applications (Final Report)

Current structural alloys, code certified for the MSRs temperature ranges, contain high levels of chromium, making them highly susceptible to molten halide salt corrosion. One potential solution to circumvent the need for code certification of novel alloys, which is expensive and time consuming, is to design claddings that will protect the underlying code certified materials from corrosion damage during operation. In this work, we examined the corrosion of Ni and Cu electroplated, Ni and CuNi weld overlay, Mo-laser clad, and carburized claddings on SS316H for use in molten salt reactor environments. After characterization of the cladded materials (Task 1), static corrosion tests were used to assess corrosion resistance of the claddings in typical molten fluoride salts (Task 2). The corrosion tests were performed in molten FLiNaK at 700°C up to 1000 hours. Pre- and post-corrosion Scanning Electron Microscopy (SEM), energy-dispersive-spectroscopy (EDS), Transmission Electron Microscopy (TEM), X-ray Diffraction (XRD) and glow-discharge-optical-emission-spectroscopy (GDOES) were performed on cladding cross-sections and surfaces to evaluate degradation. The Cu and Ni electroplated samples, as well as the carburized samples, showed excellent corrosion resistance relative to the bare SS316H. To assess high temperature cladding stability, ageing experiments were performed at temperatures up to 900 C in inert atmosphere for the electroplated and carburized samples and a diffusion model was developed to predict long term cladding behavior (Task 3). It was found that the Cu cladding was basically insensitive to the high temperature ageing, except for small secondary phases forming at the interface. On the other hand, the Ni electroplated cladding experienced significant interdiffusion. Nevertheless, the gain in corrosion resistance for a 100μm Ni electroplated cladding is phenomenal, with more than 50% reduction in chromium dissolution from the substrate material for the first 15 years of salt exposure at 700°C. To assess radiation resistance and phase stability, high-temperature 4MeV Ni heavy ion irradiation was performed across the cladding/substrate interface up to 50 displacement-per-atom (DPA) at 500°C and 700°C to assess the phase stability and irradiation behaviors of the electroplated systems (Task 4). The Ni and Cu electroplated systems did not experience void swelling at the contrary to the SS316H substrate due to their nanocrystalline nature. Some level of recrystallization was observed in the cladding, as well as radiation induced segregation and enhanced diffusion. The interface acted as a potent sink for point defects with the presence of a void denuded zone. The mechanical properties of the claddings were assessed using thermal shock, micro-indentation, nano-indentation, and four-point bend testing experiments (Task 5). These experiments were performed on the claddings in as-received, corroded, irradiated, and thermally aged states to determine the effects of typical molten salt reactor environments on cladding integrity. No significant mass loss was observed after repeated thermal shocks. While the electroplated samples softened after high-temperature ageing, irradiation hardening compensate this effect, such that there is little different with the as-received materials. The results of these experiments suggest that the electroplated (copper/nickel) show the greatest promise for application in molten salt reactor development. These claddings prevented any chromium dissolution from occurring during the static corrosion experiments. Additionally, they demonstrated favorable properties for high temperature diffusion, phase stability, interfacial mechanical properties, and irradiation resistance. Weld-overlay cladding are also of great interest and could reach properties similar to the electroplated samples upon optimization (especially with multiple weld passes). The carburized SS316H showed excellent behavior as well, but more work needs to be done to assess their long-term stability. Finally, the Mo-laser clad system was not pursued further due to the manufacturing challenges. It is also worth noting that the Ni cladding systems should behave relatively well in terms of weldability since the Ni-weld overlay microstructure and associated corrosion rate are sound. While the NiCu weld-overlay has even lower corrosion rates than the Ni-weld overlay, more studies on welding of Cu-electroplated systems are necessary since Cu clusters are known to embrittle steels.

36 MATERIALS SCIENCE↗

Detection of Intergranular Corrosion in Cold Plate Face Sheets

Cold plates are critical for cooling electronic systems in the shuttle. As a result of the environmental conditions in which they operate, water can condense between them and a support shelf. In some cases, this water results in intergranular corrosion in the face sheet. If the intergranular corrosion sufficiently penetrates the face sheet, a coolant leak could occur and jeopardize cold plate operation. This paper examines techniques for detecting and characterizing the intergranular corrosion, to enable recertification of cold plates that have been in operation for 15 plus years. Intergranular corrosion was artificially induced in the face sheets of a series of cold plate specimens using an electrochemical process. Some of the cold plate specimens were separated for destructive characterization of the extent of corrosion produced by the electrochemical process and to insure the induced corrosion was intergranular. The rest of the specimens were characterized nondestructively using several techniques. X-ray tomography and ultrasonic techniques provided the best indication of corrosion in these specimens and will be the focus of this paper. An x-ray tomography technique was shown to be the most effective technique for characterizing depth of the intergranular corrosion. From these measurements, corrosion profile maps were developed that were consistent with subsequent destructive evaluations of the specimens. This enabled the assessment of NDE (ondestructive evaluation) standards to evaluate the viability of other NDE techniques. Due to system constraints, a different technique must be used to inspect an entire cold plate. An ultrasonic technique was shown to be very reliable for detection of corrosion in the unbacked regions of the face sheet. The ultrasonic technique was performed in an alcohol bath to avoid additional corrosion during the NDE evaluation. A pulse echo technique that focuses on the RMS value of the signal is shown to be very sensitive to the presence of intergranular corrosion.

Winfree, William P.↗

A Multifunctional Coating for Autonomous Corrosion Control

Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where they are needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into the microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy.

Calle, Luz M.↗

A Multifunctional Smart Coating for Autonomous Corrosion Control

Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on micro-encapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy. This

Calle, Luz Marina↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

aqueous environment↗

Corrosion Resistance of Cu-Ni-Si Alloy Under High-Temperature, High-Pressure H{sub 2}S and Cl{sup −} Environments

In this study, Cu-Ni-Si alloy was subjected to corrosion resistance tests under simulated high-temperature, high-pressure H{sub 2}S and Cl{sup −} environments. The corrosion rates, electrochemical performance, surface morphologies, and chemical compositions of the Cu-Ni-Si alloy after corrosion were analyzed by the mass loss method, electrochemical impedance spectroscopy, scanning electron microscopy, energy-dispersive x-ray spectrometry, and x-ray diffraction. The results showed that, at the initial stage of corrosion, because of the loose corrosion product layer initially formed on the surface, a high corrosion rate was observed for the Cu-Ni-Si alloy under high-temperature, high-pressure environments. With the progress of corrosion, the corrosion rate gradually decreased and reached a steady state. Because at the later stage, a passive film was formed on the alloy surface, further inhibiting the corrosion of the alloy and improved its corrosion resistance. The Cu-Ni-Si alloy exhibited good corrosion resistance under high-temperature, high-pressure H{sub 2}S and Cl{sup −} environments.

36 MATERIALS SCIENCE↗

Characterization of Encapsulated Corrosion Inhibitors Containing Microparticles for Environmentally Friendly Smart Coatings

This poster presents the results obtained from experiments designed to evaluate the release properties, as well as the corrosion inhibition effectiveness, of several encapsulated corrosion inhibitors. Microencapsulation has been used in the development of environmentally friendly multifunctional smart coatings. This technique enables the incorporation of autonomous corrosion detection, inhibition and self-healing functionalities into many commercially available coating systems. Select environmentally friendly corrosion inhibitors were encapsulated in organic and inorganic pH-sensitive microparticles and their release in basic solutions was studied. The release rate results showed that the encapsulation can be tailored from fast, for immediate corrosion protection, to slow, which will provide continued long-term corrosion protection. The incorporation of several corrosion inhibitor release profiles into a coating provides effective corrosion protection properties. To investigate the corrosion inhibition efficiency of the encapsulated inhibitors, electrochemical techniques were used to obtain corrosion potential, polarization curve and polarization resistance data. These measurements were performed using the free as well as the encapsulated inhibitors singly or in combinations. Results from these electrochemical tests will be compared to those obtained from weight loss and other accelerated corrosion experiments.

Coatings↗

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Corrosion of 907 Steel Influenced by Sulfate-Reducing Bacteria

The effect of sulfate-reducing bacteria (SRB) on the corrosion of 907 steel was investigated. Results demonstrated that the chemical composition of corrosion products, the corrosion rate, and corrosion type were altered due to the adherence of SRB and the subsequent formation of biofilm on the 907 steel surface. Different from the case in sterile medium that ferrous oxides predominated in the corrosion products, ferrous sulfide was an important component in SRB-containing medium. Meanwhile, corrosion of 907 steel was enhanced by SRB, and the corrosion rate was dependent on their metabolic activity, which increased, stabilized, and decreased in the exponential growth, death, and residual phases, respectively. Furthermore, the corrosion type was changed from uniform corrosion to localized corrosion with the introduction of SRB, and the development process was analyzed based on the current distribution map of wire beam electrodes. In sterile medium, the maximum current density decreased with the immersion time extended, and there were no significant anodic current peaks in the late period, while in SRB-containing medium, the ratio between cathodic areas and anodic areas was high in the exponential growth phase, and stable anodic sites formed gradually in death and residual phases, which facilitated the development of localized corrosion.

36 MATERIALS SCIENCE↗

Corrosion of Al-Fe self-pierce riveting joints with multiphysics-based modeling and experiments

Self-piercing riveting (SPR) is an extensively used joining technique to assemble dissimilar materials. However, this joining of the dissimilar materials can generate galvanic/crevice corrosion, which can drastically impact the mechanical properties and the service life of the joint. In this study, a multiphysics-based hybrid modeling approach is developed for the galvanic corrosion of the Al-Fe SPR joints, which can consider the corrosion initiation and corrosion evaluation jointly. Experimental studies are first performed to extract information regarding the corrosion initiation sites, corrosion evolution and overall corrosion induced material loss in SPR joints. The initiation information is then passed onto the multiphysics FE model thus making it a hybrid model. This model can help understand the influences of metal microstructure on the corrosion propagation while the morphology changes can also be analyzed. Using the developed hybrid modeling approach, thorough parametric studies can be performed to explore the coupled impacts of multiple corrosion factors on the corrosion behavior of the joints. The developed hybrid model is validated on the prediction of galvanic corrosion for the SPR joints by comparing with experimental observations.

36 MATERIALS SCIENCE↗

SiC cladding corrosion and mitigation

Silicon carbide (SiC) is a leading candidate for accident tolerant fuel. Testing of SiC in autoclaves at 360 C. degrees in simulated coolant resulted in little corrosion. However, testing of SiC tubes in the Massachusetts Institute of Technology (MIT) reactor manufactured in the same way had unacceptable corrosion levels. This in-reactor SiC corrosion issue is now being addressed by Westinghouse in tests being carried out at our Churchill, PA facility and in tests in the MIT reactor. The suspected driver for the excessive corrosion is the generation of oxidative water radiolysis products in the core. The MIT reactor was identified as running at H{sub 2} levels of ∼20 to 22 cc/kg coolant (cubic centimeters standard temperature and pressure per kilogram coolant) which were below those normally specified in operating pressurized water reactors (PWRs) of 25 to 50 cc/kg. Hydrogen is used to react with the radiolysis products to reduce them to water. The current MIT reactor tests will be run at H{sub 2} concentration levels of ∼50 cc/kg. The applicability of this approach has been supported by recent papers in the literature. Parallel testing at Churchill is being carried out to verify the efficacy of this approach using autoclaves operating at 345 C.degrees with H{sub 2}O{sub 2} injection to simulate the water radiolysis products. Various concentrations of H{sub 2} are being tested to determine the effect on SiC corrosion rate. Further studies are underway to investigate the effects of different SiC fabrication and structural parameters and to optimize for improved corrosion performance. This paper compares the results of the corrosion tests in the MIT reactor and the autoclave tests with H{sub 2}O{sub 2} injection and the effect of H{sub 2} injection on the SiC corrosion rate. The results of the autoclave tests with H{sub 2}O{sub 2} addition indicate that corrosion rates for SiC can be achieved that are much higher than those achieved in a reactor. It appears that the use of H{sub 2}O{sub 2} addition in flow through loops to simulate the corrosion rate of SiC samples in reactor is feasible. The use of H{sub 2} addition to reduce the corrosion rate in-reactor of SiC appears to be feasible.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Corrosion of Carbon Steel Inside Used Nuclear Fuel Containers - 19492

This paper presents an overview of the carbon steel (CS) corrosion research being conducted by the Radiation Assisted Materials Performance Science (RAMPS) group at Western University, in collaboration with the Canadian Nuclear Waste Management Organization (NWMO) and Canada Natural Science and Engineering Research Council (NSERC). The objective of our studies is to develop a high-fidelity CS corrosion dynamic model that can be used to assess the integrity of the current Canadian used fuel container (UFC) design with confidence. Our key findings, the implications of the findings on corrosion science in general, and the potential consequences of these results on the predictions for long-term UFC integrity are described. Results are presented on the following five themes: chemical kinetics of γ-radiolysis of liquid water and humid air, aqueous corrosion of CS under γ-radiation, corrosion of CS under small water volumes and water filled gaps, Liesegang ring formation in a gel medium, and radiation-induced iron oxide nanoparticle formation from dissolved metal ions. These studies together represent a detailed and integrated examination of the whole CS corrosion system, and in particular, its behaviour under γ-radiation. The key finding of this research is that under certain conditions, the CS corrosion system can exhibit non-linear dynamic behaviours - which can be seen in periodic precipitation patterns and oscillations in measurable system properties such as corrosion potential. This throws into question existing corrosion models that do not account for these types of behaviours. We describe the preliminary steps we have taken in integrating these new understandings into a CS corrosion dynamic model that will be able to make long-term predictions of CS corrosion in the UFC environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid Interfacial Electron Microscopy Identifies Nanogalvanic Corrosion in Pearlitic Steel

The nanoscale mechanisms of localized corrosion in low carbon steels have remained elusive due to the complexity of studying the degradative material behavior at nanoscale solid-liquid interfaces. We identified various steps in the nanogalvanic corrosion processes using in-situ liquid-cell scanning transmission electron microscopy (STEM) using a microfluidic holder by Hummingbird Scientific. Initial work, performed at low magnification, identified the initiation point on a 1018 low-carbon steel surface. This initiation point was determined to be a triple junction of two ferrite grains bridging a cementite grain in contact with a baseline electrolyte of 6 uM CO2 dissolved in a buffered (2.78 uM Na2SO4) aqueous solution, pH 6.1. The pre-etched low-carbon steel surface was prepared using focused ion beam lift-out procedures to extract a cross-section of the low-carbon steel surface, which then was thinned to about 150 nm and transferred to a SiN membrane microfluidic window. The transfer was made using a lift-out needle to attach the low-carbon steel lamella to the corner of the SiN window, and then Pt/C deposition held the lamella in contact with the window while it was released from the lift out needle. To identify the triple point on the low carbon steel lamella, prior to attachment on the SiN window, the sample was characterized for compositional variations with energy dispersive x-ray spectroscopy mapping, grain orientation and phase mapping with precession electron diffraction, and thickness mapping with energy filtered transmission electron microscopy. This pre-characterization prior to the in-situ experiment provided a map of the multiphase and multigrain structure, where the in-situ liquid cell imaging provided a clear understanding of the initiation point on the sample. These data were cross-correlated to paint a holistic picture of the triple junction site, enabling low electron-fluence in-situ snapshot imaging to avoid dominating the native corrosion reactions with effects from the incident electron beam. This initial result identified that localized, nanogalvanic corrosion at the phase interface was the dominant corrosion process in the low-carbon steel, so we next targeted the observation of an array of these nanogalvanic features phase boundaries in a pearlite grain. Near-surface ferrite/cementite phase interfaces that typify pearlitic low-carbon steel were extracted, pre-characterized, and imaged for the in-situ corrosion processes. The sample was a cross-section from a pearlite grain, with alternating ferrite and cementite grains that extended microns down from the pre-etched low-carbon steel pipe surface. After contact with a buffered aqueous solution, the phase boundaries between the ferrite and cementite began to dissolve, with observable material loss and thickness changes in the dark-field and bright-field STEM images. Within minutes, the corrosion front proceeded deeper into the material, claiming a thin layer of ferrite around all exposed phase boundaries before progressing laterally into the ferrite matrix, converting the ferrite to corrosion product normal to each buried cementite grain. Formation of the corrosion product causes a volumetric expansion, creating a lateral wedging force that mechanically ejects the cementite grains from their grooves and leaves behind percolation channels into the steel substructure. Rapid and deleterious, this nanogalvanic corrosion pathway represents an important target for understanding and preventing run-away degradation in this common building material. Observation of this corrosion mechanism was enabled by the combination of pre-characterization using standard structural, grain, and compositional analysis in the TEM, which provides maps for understanding the reaction propagation captured in low-dose, in-situ, liquid-cell STEM.

corrosion↗

Aging Hanford Nuclear Waste Using Carbon Dioxide to Evaluate Corrosion at Lower pH Limits - 18467

Samples of Hanford Nuclear Reservation (HNR) tank waste and simulated Hanford tank waste were exposed to carbon dioxide gas (CO{sub 2}) in the laboratory in order to decrease the pH of the solution. Sodium hydroxide is required to be added to some tanks according to waste handling specifications to keep tanks protected from pitting corrosion, but the maximum-allowed volume in some tanks is currently approaching capacity. Decreasing the pH of tank solutions using CO{sub 2} gas mimics the environmental exposure chemistry, does not add sodium, and allows for testing on solutions currently categorized as out-of-specification according to technical waste handling documents. Legacy alloy A537 Class 1 carbon steel was used to construct the AN tanks on the HNR and was utilized for this testing. The planned testing of three solutions included a simulant for feasibility and a waste solution from Tank 241-AN-102 (AN-102), taken in 2013, which was run in duplicate. The solutions were evaluated for corrosion potential using cyclic potentiodynamic polarization (CPP) scans to determine the propensity for stress corrosion cracking and pitting corrosion. Results in all solutions showed that pitting potential was low when the pH was above 11 and temperatures were below 40 deg. C. As solution pHs dipped into the 10- 10.5 range, there were mixed results. CPP scans were initially run at the higher temperature of 50 deg. C, accelerating corrosion rates. Solution pHs that did not indicate corrosion were further exposed to CO{sub 2}. Solutions with mixed or positive pitting results were rerun at 40 deg. C. The first failed run on the tank solution was seen when testing the duplicate sample at 50 deg. C and a pH of 13.01. When this solution was retested at 40 deg. C, the CPP scan did not show corrosion. A mixed corrosion result was obtained from a scan run at the final pH of 10 when tested at 50 deg. C. Upon completion of testing a visual inspection of the coupon did not show corrosion products on its surface. These results provide assurance that tanks containing slightly reduced pHs are still protected from pitting corrosion. Tank integrity assurance at a lower pH limit in Tank AN-102 could slow sodium addition and the rising volume of hazardous waste. Other benefits of reducing the pH specification would be reduced costs associated with retrieving and storing smaller volumes of hazardous waste, a reduced number of radiation exposure events (required for pH modification of tank waste), and a potential for a decreased volume required to be immobilized for long-term storage in a vitrified (glass) phase. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncertainty Quantification for Dissimilar Material Joints Under Corrosion Environment

Abstract Self-Piercing Riveting (SPR) is one of the most commonly used methods for joining dissimilar materials in the automotive industry. These joints are popular due to their adaptability, high performance and short cycle time. However, since these joints involve two dissimilar materials, they are susceptible to galvanic corrosion in the presence of an electrolyte which is driven by the difference in the equilibrium potential of the metals. This can affect the safety and resilience of these joints. In this paper, we focus on galvanic corrosion in Al-Fe SPR joints. A Machine learning (ML) based surrogate model, which is based off of FE simulations, for statistical corrosion analysis is developed. This model enables the resilience and reliability analysis of SPR joints under corrosion environment. In this study, first a physics-based finite element (FE) corrosion model has been developed to simulate the galvanic corrosion between a Fe cathode and an Al anode of a SPR joint. This model takes into account the effect of the crystal microstructure of the Al anode and the precipitation of the corrosion product. Several geometric and environmental factors including crevice gap, roughness of anode, conductivity, pH and the temperature of the electrolyte that effect corrosion are investigated. A thorough Uncertainty Quantification (UQ) analysis is conducted for the overall corrosion behavior of the Fe-Al SPR joints using a novelistic Probabilistic Confidence-Based Adaptive Sampling (PCAS) technique. PCAS is used to train the surrogate model by identifying the critical sampling points and thus reducing the overall computational costs. It is found that the electrolyte temperature has the largest effects on the material loss and needs to be managed closely for better corrosion control. By understanding the corrosion performance and resultant uncertainty impact on SPR joints, the reliability and resilience of these joints can be improved.

36 MATERIALS SCIENCE↗