High-temperature-materials study
Chemical vapor deposition of aluminum phosphides onto single crystals of silicon and gallium arsenide for producing high temperature operating solid state electronic devices
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Chemical vapor deposition of aluminum phosphides onto single crystals of silicon and gallium arsenide for producing high temperature operating solid state electronic devices
Battery of tests determines the primary dimensions of perceptual-motor performance. Eighteen basic measures range from simple tests to sophisticated electronic devices. Improved system has one unit for the subject containing test display and response elements, and one for the experimenter where test setups, programming, and scoring are accomplished.
Heat pipe is used in the primary heat exchanger for nuclear power plants, as a heat sink for high-power electronic devices, and in a closed-cycle heat rejection mechanism for cryogenic storage tanks. It serves simultaneously as a heat transfer device and as a structural member.
Portable electronic device, based on the design of an eddy current gage, detects ferrous and nonferrous metal fragments. Device is more easily transported than X-ray equipment and does not present a radiation hazard.
OAO thermal subsystem design to provide temperature control for experiments and spacecraft electronic devices
Development of materials for encapsulating electronic devices used in biotelemetry is discussed. Chemical resistance of materials to effects of animal fluids is described. Silicone rubber is recommended as basic material with polymers applied to outer surface for protective coating.
A wide variety of simple test calibration circuits are compiled for the engineer and laboratory technician. The majority of circuits were found inexpensive to assemble. Testing electronic devices and components, instrument and system test, calibration and reference circuits, and simple test procedures are presented.
Electronic devices and instruments currently used to track animals in order to determine their migratory and navigational behavior are discussed. Passive and active transducers in use for this purpose are described. The characteristics of the data received by the transducers and the equipment used to process the data are explained.
The locations of various parts of the Surveyor camera are presented. Tables were prepared with emphasis on: (1) exterior parts and surfaces that are directly exposed to space, (2) parts that shield others from space radiation, (3) representative or unique materials, and (4) electronic devices that may contain unique or well-characterized materials.
Ohmmeter is used to indicate positive contact between electrodes and workpiece. This permits good soldering and prevents damage to electronic devices.
The problem statements presented relate mostly to research on prosthetic equipment and means of attaching biomedical and electronic devices to the human body. A patent application for a reliable switching element in a patient assist control units is also described.
The present work describes three electronic devices designed for use in the Skylab airlock module: the teleprinter system, the quartz crystal microbalance contamination monitor (QCM), and the speaker. Design considerations, operation, characteristics, and system development are described for these systems, with accompanying diagrams, graphs, and photographs. The teleprinter is a thermal dot printer used to produce hard copy messages by electrically heating print elements in contact with heat-sensitive paper. The QCM was designed to estimate contamination buildup on optical surfaces of the earth resources experiment package. A vibrating quartz crystal is used as a microbalance relating deposited mass to shifts in the crystal's resonant frequency. Audio devices provide communication between crew members and between crew and STDN, and also provide audible alarms, via the caution and warning system, of out-of-limit-conditions.
Autotest is a flexible, fully automatic, programmable test system. It is externally controlled by a mnemonic test language. Once started, tests can run to completion without further manual intervention. Autotest can be operated manually as well as in automatic mode. Autotest can be adapted to a wide variety of test requirements. Though originally designed to test the Atmosphere Explorer (AE) spacecraft and experiments, autotest can easily be modified to test any electronic device suitable for automated computer testing.
Digital electronic device uses superconducting filaments as sensors. Simple solid-state circuitry combined with filaments comprise highly-reliable temperature monitor. Device has ability to track very fast thermal transients and "on/off" output is adaptable to remote sensing and telemetry.
The aligned structures which result from the directional solidification (DS) of ceramic eutectics are of interest because of their potential for use in electronic devices and as structural materials. Techniques for growing DS ceramic eutectics are briefly discussed. The principles and controlling parameters of DS eutectic growth are described. The criteria for plane-front growth and the effect of growth rate on interlamellar or interfiber spacing are discussed. Examples of the effect of growth parameters on the alignment of the microstructure are given. Examples of the mechanical properties of directionally solidified oxide-oxide ceramics are also cited.
The concept of reducing the losses in an induction motor by electronically controlling the time interval between the zero crossing of the applied voltage and the zero crossing of the armature current was evaluated. The effect on power losses and power factor of reducing the applied sinusoidal voltages below the rated value was investigated experimentally. The reduction in power losses was measured using an electronic controller designed and built at MSFC. Modifications to the MSFC controller are described as well as a manually controlled electronic device which does not require that the motor be wye connected and the neutral available. Possible energy savings are examined.
The conceptual design of the Jupiter probe spectrometer is presented. Block and circuit diagrams are presented along with tabulated parts lists. Problem areas are considered to be (1) the schedule, (2) weight limitations for the electronic systems, and (3) radiation hardness of the electronic devices.
The potential hazard to electrical and electronic devices should there be a release of free carbon fibers due to an aircraft crash and fire was assessed. Exposure and equipment sensitivity data were compiled for a risk analysis. Results are presented in the following areas: DC-9/DC-10 electrical/electronic component characterization; DC-9 and DC-10 fiber transfer functions; potential for transport aircraft equipment exposure to carbon fibers; and equipment vulnerability assessment. Results reflect only a negligible increase in risk for the DC-9 and DC-10 fleets either now or projected to 1993.