Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The 3D Lyman- α forest power spectrum from eBOSS DR16

We measure the three-dimensional power spectrum (P3D) of the transmitted flux in the Lyman-α (Ly α) forest using the complete extended Baryon Oscillation Spectroscopic Survey data release 16 (eBOSS DR16). This sample consists of ~205 000 quasar spectra in the redshift range 2 ≤ z ≤ 4 at an effective redshift z = 2.334. We propose a pair-count spectral estimator in configuration space, weighting each pair by exp( i k ∙ r), for wave vector k and pixel pair separation r, effectively measuring the anisotropic power spectrum without the need for fast Fourier transforms. This accounts for the window matrix in a tractable way, avoiding artefacts found in Fourier-transform based power spectrum estimators due to the sparse sampling transverse to the line of sight of Ly α skewers. We extensively test our pipeline on two sets of mocks: (i) idealized Gaussian random fields with a sparse sampling of Ly α skewers, and (ii) log-normal LyaCoLoRe mocks including realistic noise levels, the eBOSS survey geometry and contaminants. On eBOSS DR16 data, the Kaiser formula with a non-linear correction term obtained from hydrodynamic simulations yields a good fit to the power spectrum data in the range $(0.02 ≤ k ≤ 0.35)$ h Mpc -1 at the 1–2σ level with a covariance matrix derived from LyaCoLoRe mocks. We demonstrate a promising new approach for full-shape cosmological analyses of Ly α forest data from cosmological surveys such as eBOSS, the currently observing Dark Energy Spectroscopic Instrument and future surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST.

79 ASTRONOMY AND ASTROPHYSICS↗

Spread spectrum communication link using surface wave devices

A fast lock-up, 8-MHz bandwidth 8,000 bit per second data rate spread spectrum communication link breadboard is described that is implemented using surface wave devices as the primary signal generators and signal processing elements. It uses surface wave tapped delay lines in the transmitter to generate the signals and in the receiver to detect them. The breadboard provides a measured processing gain for Gaussian noise of 31.5 dB which is within one dB of the theoretical optimum. This development demonstrates that spread spectrum receivers implemented with surface wave devices have sensitivities and complexities comparable to those of serial correlation receivers, but synchronization search times which are two to three orders of magnitude smaller.

Hunsinger, B. J.↗

A surface wave spread spectrum communication link.

This development has resulted in a fast lock-up, 8-MHz bandwidth, 8-KHz data rate, spread spectrum communication link breadboard that is implemented using surface wave devices as the primary signal generators and signal processing elements. It uses surface wave tapped delay lines (SWTDL's) in the transmitter to generate the signals and in the receiver to match filter detect them. The system also incorporates a re-entry delay line (circulating integrator) which increases the effective code length per data bit by eight-fold.

Fugit, B. R.↗

Critical response to M. Worrall et al. Published in Annals of Nuclear Energy 207 (2024) 110731

M. Worrall et al. recently published a manuscript titled “Fast neutron irradiation capability in existing thermal test reactors” (Worrall, 2024) that summarizes an irradiation vehicle design that would boost the fast neutron flux in the Advanced Test Reactor (ATR) for testing of nonfuel materials in a neutron flux energy spectrum that is more representative of fast reactors. Here, the authors compare their design with a separate vehicle design that they conceived of that would be implemented within the High Flux Isotope Reactor (HFIR). They analyzed both designs and drew conclusions on the most realistic near-term options for shielded nonfuel material irradiations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Longwave infrared (6.6–11.4 µm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate

Using sub-3-cycle pulses from mode-locked Cr:ZnS lasers at λ ≈ 2.4 µm as a driving source, we performed high-resolution dual-frequency-comb spectroscopy in the longwave infrared (LWIR) range. A duo of highly coherent broadband (6.6–11.4 µm) frequency combs were produced via intrapulse difference frequency generation in zinc germanium phosphide (ZGP) crystals. Fast (up to 0.1 s per spectrum) acquisition of 240,000 comb-mode-resolved data points, spaced by 80 MHz and referenced to a Rb clock, was demonstrated, resulting in metrology grade molecular spectra of N 2 O (nitrous oxide) and CH 3 OH (methane). The key to high-speed massive spectral data acquisition was low intensity and phase noise of the LWIR combs and high (7.5%) downconversion efficiency, resulting in a LWIR power of 300 mW for each comb.

Vasilyev, Sergey (ORCID:0000000225203547)↗

IUE observations of the 1981 outburst of nova Cr A

Low dispersion spectrum observations are analyzed. The light curve of nova Cr A, indicating a moderately fast nova, is presented. Flux calibrated, merged spectrum graphs of April 21, 1981 and September 13, 1981 are presented, demonstrating very strong lines of Al and Si. Additional strong C, Ni, O, and Ne emission lines were identified. Emission lines due to highly ionized species such as Mg VII and Al Vl were observed for short times in May and June 1981. Preliminary analysis of spectra obtained 200 days after maximum indicate that the nebula is still in transition and has not yet reached the nebula state. An over abundance of N and Ne are suggested.

Sparks, W. M.↗

The High-Frequency Signature of Slow and Fast Laboratory Earthquakes

Tectonic faults fail through a spectrum of slip modes, ranging from slow aseismic creep to rapid slip during earthquakes. Understanding the seismic radiation emitted during these slip modes is key for advancing earthquake science and earthquake hazard assessment. In this work, we use laboratory friction experiments instrumented with ultrasonic sensors to document the seismic radiation properties of slow and fast laboratory earthquakes. Stick-slip experiments were conducted at a constant loading rate of 8 μm/s and the normal stress was systematically increased from 7 to 15 MPa. We produced a full spectrum of slip modes by modulating the loading stiffness in tandem with the fault zone normal stress. Acoustic emission data were recorded continuously at 5 MHz. We demonstrate that the full continuum of slip modes radiate measurable high-frequency energy between 100 and 500 kHz, including the slowest events that have peak fault slip rates <100 μm/s. The peak amplitude of the high-frequency time-domain signals scales systematically with fault slip velocity. Stable sliding experiments further support the connection between fault slip rate and high-frequency radiation. Experiments demonstrate that the origin of the high-frequency energy is fundamentally linked to changes in fault slip rate, shear strain, and breaking of contact junctions within the fault gouge. Our results suggest that having measurements close to the fault zone may be key for documenting seismic radiation properties and fully understanding the connection between different slip modes.

58 GEOSCIENCES↗

Nuclear response of additive manufactured GRCop-84 copper for use in Lower hybrid launchers in a fusion environment

Recent advances in selective laser melting (SLM) 3D printing technology allow additive manufacture of lower hybrid current drive (LHCD) RF launchers from a new material, Glenn Research Copper 84 (GRCop-84), a Cr 2 Nb (8 at. % Cr, 4 at. % Nb) precipitation hardened alloy, in configurations unachievable with conventional machining. Tensile strength and thermal conductivity are compared to other competing high conductivity copper alloys for fusion use. Swelling and conductivity at 100 DPA when exposed to the Hanford Fast Flux Test Facility neutron spectrum is predicted in the 1–2 % and 65-70% IACS range, respectively, by comparison to copper alloys with similar precipitate and grain size. Finally, self-similar ion irradiation of a GRCop-84 target at 430 °C to 20 DPA resulted in no noticeable void formation in FIB cross sections or TEM lamella.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of COTS Electronics by Power Spectrum Analysis and Multivariate Data Analysis

Power spectrum analysis (PSA) is a fast, non-destructive, sensitive method for examining commercial off-the-shelf ( COTS ) electronic components. These features make PSA attractive for both component screening and surveillance in support of component reliability efforts. Current analysis methods limit the utility of PSA due to the need to manually examine the results of analysis to identify anomalous parts. This study demonstrates the development and application of a workflow to automate the screening of COTS electronic components. Further, this study demonstrates the use of multivariate algorithms to assess aging of Zener diodes. These workflows can be readily extended to other components, combining the benefits of PSA and multivariate analysis to screen and evaluate COTS electronic components.

42 ENGINEERING↗

Automated Algorithms for Screening Electronic Parts for Aging using Power Spectra Analysis (PSA) Data

Understanding the age of semiconductor parts being built into devices and systems is of interest for manufacturing quality control. Power spectrum analysis (PSA) is a fast, non-destructive, sensitive method for examining semiconductor parts. This talk will cover the use of multivariate analysis on both PSA data and conventional current-voltage data generated prior to PSA analysis to create algorithms that can be automated to screen semiconductor parts for aging.

Multari, Rosalie A↗

Numerical evaluation of the radiation from unbaffled, finite plates using the FFT

An iteration technique is described which numerically evaluates the acoustic pressure and velocity on and near unbaffled, finite, thin plates vibrating in air. The technique is based on Rayleigh's integral formula and its inverse. These formulas are written in their angular spectrum form so that the fast Fourier transform (FFT) algorithm may be used to evaluate them. As an example of the technique the pressure on the surface of a vibrating, unbaffled disk is computed and shown to be in excellent agreement with the exact solution using oblate spheroidal functions. Furthermore, the computed velocity field outside the disk shows the well-known singularity at the rim of the disk. The radiated fields from unbaffled flat sources of any geometry with prescribed surface velocity may be evaluated using this technique. The use of the FFT to perform the integrations in Rayleigh's formulas provides a great savings in computation time compared with standard integration algorithms, especially when an array processor can be used to implement the FFT.

Williams, E. G.↗

Plural-wavelength flame detector that discriminates between direct and reflected radiation

A flame detector employs a plurality of wavelength selective radiation detectors and a digital signal processor programmed to analyze each of the detector signals, and determine whether radiation is received directly from a small flame source that warrants generation of an alarm. The processor's algorithm employs a normalized cross-correlation analysis of the detector signals to discriminate between radiation received directly from a flame and radiation received from a reflection of a flame to insure that reflections will not trigger an alarm. In addition, the algorithm employs a Fast Fourier Transform (FFT) frequency spectrum analysis of one of the detector signals to discriminate between flames of different sizes. In a specific application, the detector incorporates two infrared (IR) detectors and one ultraviolet (UV) detector for discriminating between a directly sensed small hydrogen flame, and reflections from a large hydrogen flame. The signals generated by each of the detectors are sampled and digitized for analysis by the digital signal processor, preferably 250 times a second. A sliding time window of approximately 30 seconds of detector data is created using FIFO memories.

Hall, Gregory H.↗

Electro-Optical Imaging Fourier-Transform Spectrometer

An electro-optical (E-O) imaging Fourier-transform spectrometer (IFTS), now under development, is a prototype of improved imaging spectrometers to be used for hyperspectral imaging, especially in the infrared spectral region. Unlike both imaging and non-imaging traditional Fourier-transform spectrometers, the E-O IFTS does not contain any moving parts. Elimination of the moving parts and the associated actuator mechanisms and supporting structures would increase reliability while enabling reductions in size and mass, relative to traditional Fourier-transform spectrometers that offer equivalent capabilities. Elimination of moving parts would also eliminate the vibrations caused by the motions of those parts. Figure 1 schematically depicts a traditional Fourier-transform spectrometer, wherein a critical time delay is varied by translating one the mirrors of a Michelson interferometer. The time-dependent optical output is a periodic representation of the input spectrum. Data characterizing the input spectrum are generated through fast-Fourier-transform (FFT) post-processing of the output in conjunction with the varying time delay.

Chao, Tien-Hsin↗

JPL 2-to-the-20th-power channel 300 MHz bandwidth digital spectrum analyzer

A million (two to the 20th power) channel, 300 MHz bandwidth, digital spectrum analyzer was considered. The design, fabrication, and maintenance philosophy of the modular, pipelined, fast fourier transform (FFT) hardware are described. The spectrum analyzer will be used to examine the region from 1.4 GHz to 26 GHz for radio frequency interference which may be harmful to present and future tracking missions of the Deep Space Network. The design has application to the search for extraterrestrial intelligence signals and radio science phenomena.

Morris, G. A., Jr.↗

New Approach to Ultrasonic Spectroscopy Applied to Flywheel Rotors

Flywheel energy storage devices comprising multilayered composite rotor systems are being studied extensively for use in the International Space Station. A flywheel system includes the components necessary to store and discharge energy in a rotating mass. The rotor is the complete rotating assembly portion of the flywheel, which is composed primarily of a metallic hub and a composite rim. The rim may contain several concentric composite rings. This article summarizes current ultrasonic spectroscopy research of such composite rings and rims and a flat coupon, which was manufactured to mimic the manufacturing of the rings. Ultrasonic spectroscopy is a nondestructive evaluation (NDE) method for material characterization and defect detection. In the past, a wide bandwidth frequency spectrum created from a narrow ultrasonic signal was analyzed for amplitude and frequency changes. Tucker developed and patented a new approach to ultrasonic spectroscopy. The ultrasonic system employs a continuous swept-sine waveform and performs a fast Fourier transform on the frequency spectrum to create the spectrum resonance spacing domain, or fundamental resonant frequency. Ultrasonic responses from composite flywheel components were analyzed at Glenn to assess this NDE technique for the quality assurance of flywheel applications.

Harmon, Laura M.↗

Progress in Interferometric Rayleigh Scattering to Measure Fluctuations Spectra of Velocity and Temperature in High Speed Flows

A new, spectrally-resolved, Rayleigh scattering setup at NASA Ames is further developed to measure fluctuations in velocity and temperature. Using a combination of a continuous-wave laser, a stabilized Fabry-Perot interferometer (FPI), an EMCCD camera, and a photo-multiplier tube, the setup was demonstrated to provide fairly accurate measurements of time-averaged velocity, temperature, density and spectrum of density fluctuations in a high-speed free jet (Panda & White, 2018). This paper describes further progress in fast measurement of the Rayleigh-Brillouin spectrum via a 16-anode linear-array of photo-multiplier tube and a multi-channel, photo-electron counter. Rayleigh scattered light from a 0.4mm long probe volume was directly imaged through the FPI and was imaged on the linear array. Synchronous photo-electron counting over a series of short, contiguous gates provided time-evolution of the fringes at a 10 kHz sampling rate. Sample spectra collected from a Mach 0.98 jet show spectral content floating on high noise-floor. Efforts to collect longer time series of data and different schemes of extracting velocity and temperature information are now in progress.

Panda, J.↗

A computer program for estimating the power-density spectrum of advanced continuous simulation language generated time histories

A computer program for performing frequency analysis of time history data is presented. The program uses circular convolution and the fast Fourier transform to calculate power density spectrum (PDS) of time history data. The program interfaces with the advanced continuous simulation language (ACSL) so that a frequency analysis may be performed on ACSL generated simulation variables. An example of the calculation of the PDS of a Van de Pol oscillator is presented.

Dunn, H. J.↗