Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

247 records · Page 14

Efficient Measurement-Driven Eigenenergy Estimation with Classical Shadows

Quantum algorithms exploiting real-time evolution under a target Hamiltonian have demonstrated remarkable efficiency in extracting key spectral information. However, the broader potential of these methods, particularly beyond ground-state calculations, is underexplored. In this work, we introduce the framework of multiobservable dynamic mode decomposition (MODMD), which combines the observable dynamic mode decomposition (DMD), a measurement-driven eigensolver tailored for near-term implementation, with classical shadow tomography. MODMD leverages random scrambling in the classical shadow technique to construct, with exponentially reduced resource requirements, a signal subspace that encodes rich spectral information. Notably, we replace typical Hadamard-test circuits with a protocol designed to predict low-rank observables, thereby broadening the use of classical shadow tomography for predicting many low-rank observables. We establish theoretical guarantees on the spectral approximation from MODMD, taking into account distinct sources of error. In the ideal case, we prove that the spectral error scales as exp (−Δ⁢𝐸⁢𝑡 max ), where Δ⁢𝐸 is the Hamiltonian spectral gap and 𝑡 max is the maximal simulation time. This analysis provides a rigorous justification of the rapid convergence observed across simulations. To demonstrate the utility of our framework, we consider its application to fundamental tasks, such as determining the low-lying, i.e., ground or excited, energies of representative many-body systems. Our work paves the path for efficient designs of measurement-driven algorithms on near-term and early fault-tolerant quantum devices.

quantum algorithms & computation↗

Profiling the Quito basin (Ecuador) using seismic ambient noise

SUMMARY Quito, the capital of Ecuador, with more than 2.5 M inhabitants, is exposed to a high seismic hazard due to its proximity to the Pacific subduction zone and active crustal faults, both capable of generating significant earthquakes. Furthermore, the city is located in an intermontane piggy-back basin prone to seismic wave amplification. To understand the basin’s seismic response and characterize its geological structure, 20 broad and medium frequency band seismic stations were deployed in Quito’s urban area between May 2016 and July 2018 that continuously recorded ambient seismic noise. We first compute horizontal-to-vertical spectral ratios to determine the resonant frequency distribution in the entire basin. Secondly, we cross-correlate seismic stations operating simultaneously to retrieve interstations surface-wave Green’s functions in the frequency range of 0.1–2 Hz. We find that Love waves travelling in the basin’s longitudinal direction (NNE–SSW) show much clearer correlograms than those from Rayleigh waves. We then compute Love wave phase-velocity dispersion curves and invert them in conjunction with the HVSR curves to obtain shear-wave velocity profiles throughout the city. The inversions highlight a clear difference in the basin’s structure between its northern and southern parts. In the centre and northern areas, the estimated basin depth and mean shear-wave velocity are about 200 m and 1800 ms−1, respectively, showing resonance frequency values between 0.6 and 0.7 Hz. On the contrary, the basement’s depth and shear-wave velocity in the southern part are about 900 m and 2500 ms−1, having a low resonance frequency value of around 0.3 Hz. This difference in structure between the centre-north and the south of the basin explains the spatial distribution of low-frequency seismic amplifications observed during the Mw 7.8 Pedernales earthquake in April 2016 in Quito.

Pacheco, D. (ORCID:0000000282355096)↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗

Classification and regression models of audio and vibration signals for machine state monitoring in precision machining systems

Here we present a data-driven method for monitoring machine status in manufacturing processes. Audio and vibration data from precision machining are used for inference in two operating scenarios: (a) variable machine health states (anomaly detection); and (b) settings of machine operation (state estimation). Audio and vibration signals are first processed through Fast Fourier Transform and Principal Component Analysis to extract transformed and informative features. These features are then used in the training of classification and regression models for machine state monitoring. Specifically, three classifiers (K-nearest neighbors, convolutional neural networks and support vector machines) and two regressors (support vector regression and neural network regression) were explored, in terms of their accuracy in machine state prediction. It is shown that the audio and vibration signals are sufficiently rich in information about the machine that 100% state classification accuracy could be accomplished. Data fusion was also explored, showing overall superior accuracy of data-driven regression models.

42 ENGINEERING↗

Cascadia Subduction Zone Fault Heterogeneities From Newly Detected Small Magnitude Earthquakes

The Cascadia subduction zone (CSZ) is known to host M9 megathrust ruptures; however, no such event has occurred in historical observation. The distribution and characteristics of small- to moderate-sized earthquakes can be used to determine the behavior of the megathrust fault but are notably absent offshore the CSZ due to the distance from onshore seismometers. We use automated subspace detection coupled with an onshore-offshore seismic deployment to find small-magnitude earthquakes in the offshore seismogenic zone and analyze their locations in the context of interseismic locking and seismogenic zone extent. Here we detected and located 5,282 earthquakes, 4,096 of which had been previously undetected. We find that the downdip extent of the seismogenic zone as defined by interplate seismicity agrees with the 20% locking contour of the Schmalzle et al. (2014, https://doi.org/10.1002/2013GC005172) geodetic model and extends deeper than predicted by previous thermal models. We cannot determine the updip extent of the seismogenic zone; this may be due to a lack of templates for detection in the updip source area, stress shadows updip of asperity loading, and/or strong locking to the trench. We present a map of possible asperities determined by the small earthquakes in this study. Our asperity locations and extents show some, but not complete, agreement with the asperities modeled from the 1700 M9 rupture and geodetic locking models, and good agreement with the paleo-rupture extents determined from offshore turbidites and forearc basin-based asperity estimates. This highlights the need of continued offshore observations over time, and to elucidate fine-scale variation in locking.

58 GEOSCIENCES↗

Advanced High-Performance Computational Modeling of the Seismic Response of High-Hazard and/or Nuclear Facilities and Critical Infrastructure at the NNSS

New methods for predicting the amplitude and variability of ground shaking from earthquakes (and explosions) are needed for seismic hazard analysis for buildings, nuclear power plants, and critical infrastructure at the NNSS. We are comparing existing 1-D and new 3-D geophysical methods for estimating the shear-wave velocity structure in the upper 30 meters of the ground surface (Vs30), which plays a major role in ground motion amplification and seismic response of buildings. We evaluate the performance of these methodologies at the U1a Complex at the NNSS and develop simple 1-D and high-resolution 3-D Vs30 models. We then emplace these high-resolution models into a background seismic velocity model. We will collaborate with Lawrence Livermore National Laboratory (LLNL) to conduct numerical modeling of the ground shaking at the NNSS using their high-performance computing technology and state-of-the-art ground motion simulation methodology. The primary work that was completed in FY 2019 was to acquire the seismic systems and familiarize staff at the NNSS with their use. We also worked on developing a collection plan with the Device Assembly Facility (DAF) at the NNSS, but due to time constraints and other ongoing projects at the DAF, we had to use U1a as a backup. We were able to coordinate the seismic survey, and we will complete the collection of seismic data in FY 2020. Additionally, during FY 2019, we completed the geologic framework model (GFM) for the U1a Complex and modeled the Yucca fault. LLNL worked with us through FY 2019 to prepare the data files for their modeling software and tested the software for reliability. In FY 2020 we will develop the end-to-end capability so that any facility could easily be modeled and the expected shaking from a local earthquake understood. The work in FY 2020 will include building fault models from the GFM and finalizing the velocity model analysis. The final simulations will be run for multiple rupture models, and final assessments will demonstrate the seismic hazard at the U1a Complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$S$ Hmax orientation in the Alpine region from observations of stress-induced anisotropy of nonlinear elasticity

The orientation of $S$ Hmax is commonly estimated from in situ borehole breakouts and earthquake focal mechanisms. Borehole measurements are expensive, and therefore sparse, and earthquake measurements can only be made in regions with many well-characterized earthquakes. Here, we derive the stress-field orientation using stress-induced anisotropy in nonlinear elasticity. In this method, we measure the strain derivative of velocity as a function of azimuth. We use a natural pump-probe (NPP) approach which consists of measuring elastic wave speed using empirical Green’s functions (probe) at different points of the earth tidal strain cycle (pump). The approach is validated using a larger data set in the Northern Alpine Foreland region where the orientation of maximum horizontal compressive stress is known from borehole breakouts and drilling-induced fractures. The technique resolves NNW-SSW to N-S directed $S$ Hmax which is in good agreement with conventional methods and the recent crustal stress model. We confirm that the NPP method can be applied to dense large-scale seismic arrays. The technique is then applied to the Southern Alps to understand the contemporary stress pattern associated with the ongoing deformation due to counterclockwise rotation of the Adriatic plate with respect to the European plate. Our results explain why the two major faults in Northeastern Italy, the Giudicarie Fault and the Periadriatic Line (Pustertal–Gailtal Fault) are currently inactive, while the currently acting stress field allows faults in Slovenia to deform actively. We have demonstrated that the pump-probe method has the potential to fill in the measurement gap left by conventional approaches, both in terms of regional coverage and in depth.

58 GEOSCIENCES↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unsupervised anomaly detection in MeV ultrafast electron diffraction

MeV ultrafast electron diffraction (MUED) is a pump-probe technique used to study the dynamic structural evolution of materials. An ultrashort laser pulse triggers structural changes, which are then probed by an ultrashort relativistic electron beam. To overcome low signal-to-noise ratios, diffraction patterns are averaged over thousands of shots. However, shot-to-shot instabilities in the electron beam can distort individual patterns, introducing uncertainty. Improving MUED accuracy requires detecting and removing these anomalous patterns from large datasets. In this work, we developed a fully unsupervised methodology for the detection of anomalous diffraction patterns. Using a convolutional autoencoder, we calculate the reconstruction mean squared error of the diffraction patterns. Based on the statistical analysis of this error, we provide the user an estimation of the probability that the pattern is normal, which also allows a posterior visual inspection of the images that are difficult to classify. This method has been trained with only 100 diffraction patterns and tested on 1521 patterns, resulting in a false positive rate between 0.2% and 0.4%, with a training time of 10 s per image and a test time of about 1 s per image. Here, the proposed methodology can also be applied to other diffraction techniques in which large datasets are collected that include faulty images due to instrumental instabilities.

43 PARTICLE ACCELERATORS↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Subsurface Characterization and Machine Learning Predictions at Brady Hot Springs Results

Geothermal power plants typically show decreasing heat and power production rates over time. Mitigation strategies include optimizing the management of existing wells - increasing or decreasing the fluid flow rates across the wells - and drilling new wells at appropriate locations. The latter is expensive, time-consuming, and subject to many engineering constraints, but the former is a viable mechanism for periodic adjustment of the available fluid allocations. Data and supporting literature from a study describing a new approach combining reservoir modeling and machine learning to produce models that enable strategies for the mitigation of decreased heat and power production rates over time for geothermal power plants. The computational approach used enables translation of sets of potential flow rates for the active wells into reservoir-wide estimates of produced energy and discovery of optimal flow allocations among the studied sets. In our computational experiments, we utilize collections of simulations for a specific reservoir (which capture subsurface characterization and realize history matching) along with machine learning models that predict temperature and pressure timeseries for production wells. We evaluate this approach using an "open-source" reservoir we have constructed that captures many of the characteristics of Brady Hot Springs, a commercially operational geothermal field in Nevada, USA. Selected results from a reservoir model of Brady Hot Springs itself are presented to show successful application to an existing system. In both cases, energy predictions prove to be highly accurate: all observed prediction errors do not exceed 3.68% for temperatures and 4.75% for pressures. In a cumulative energy estimation, we observe prediction errors that are less than 4.04%. A typical reservoir simulation for Brady Hot Springs completes in approximately 4 hours, whereas our machine learning models yield accurate 20-year predictions for temperatures, pressures, and produced energy in 0.9 seconds. This paper aims to demonstrate how the models and techniques from our study can be applied to achieve rapid exploration of controlled parameters and optimization of other geothermal reservoirs. Includes a synthetic, yet realistic, model of a geothermal reservoir, referred to as open-source reservoir (OSR). OSR is a 10-well (4 injection wells and 6 production wells) system that resembles Brady Hot Springs (a commercially operational geothermal field in Nevada, USA) at a high level but has a number of sufficiently modified characteristics (which renders any possible similarity between specific characteristics like temperatures and pressures as purely random). We study OSR through CMG simulations with a wide range of flow allocation scenarios. Includes a dataset with 101 simulated scenarios that cover the period of time between 2020 and 2040 and a link to the published paper about this project, where we focus on the Machine Learning work for predicting OSR's energy production based on the simulation data, as well as a link to the GitHub repository where we have published the code we have developed (please refer to the repository's readme file to see instructions on how to run the code). Additional links are included to associated work led by the USGS to identify geologic factors associated with well productivity in geothermal fields. Below are the high-level steps for applying the same modeling + ML process to other geothermal reservoirs: 1. Develop a geologic model of the geothermal field. The location of faults, upflow zones, aquifers, etc. need to be accounted for as accurately as possible 2. The geologic model needs to be converted to a reservoir model that can be used in a reservoir simulator, such as, for instance, CMG STARS, TETRAD, or FALCON 3. Using native state modeling, the initial temperature and pressure distributions are evaluated, and they become the initial conditions for dynamic reservoir simulations 4....

15 GEOTHERMAL ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗