Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Proton exchange membrane material and methods of making the same

Hydrocarbon proton exchange membranes are disclosed that are composed of a material including a hydrophobic main chain, and acidic side chains. The main chain includes a polyaryl structure that is substantially free of ether linkages and also includes a fluoromethyl substituted carbon. The acidic side chains include a hydrocarbon tether terminated by a strongly acidic group, such as a fluoroalkyl sulfonate group. Chemical stability of the material is increased by removing the ether linkages from the main chain. The hydrophobic main chain and substantially hydrophilic side chains create a phase-separated morphology that affords enhanced transport of protons and water across the membrane even at low relative humidity levels. These materials are advantageous as membranes for use in fuel cells, redox flow batteries, water hydrolysis systems, sensors, electrochemical hydrogen compressors, actuators, water purifiers, gas separators, etc.

Bae, Chulsung↗

Comparative Performance of Gaussian Plume and Backward Lagrangian Stochastic Models for Near-Field Methane Emission Estimation Using a Single Controlled Release Experiment

Methane (CH 4 ) is a major component of natural gas and a potent greenhouse gas. Increasing atmospheric methane concentrations are attributed to emissive anthropogenic activities by an average of 13 ppb per yr since 2020 and are linked to a changing global climate. Mitigating CH 4 emissions from oil and gas production sites has recently become a target to reduce overall greenhouse gas emissions; however, monitoring the efficacy of mitigation strategies depends on accurate quantification of CH 4 emissions at the facility-level. Near-field quantification of methane (CH 4 ) emissions from oil and gas (O&G) facilities remains challenging due to the effects of atmospheric variability and sensor configuration on atmospheric dispersion models. This study evaluates the performance of two atmospheric dispersion models, the Gaussian plume (GP) and backward Lagrangian stochastic (bLS), by comparing calculated CH 4 emissions to controlled single-point emissions between 0.4 and 5.2 kg CH 4 h −1 . Emissions were calculated by both models using 121 individual sets of measurements comprising five-minute averaged downwind methane mixing ratios and matching meteorological data. The comparison shows that the bLS approach achieved a higher proportion of emission estimates within a factor of two (FAC2) of the known emission rates compared to the GP approach. The emissions calculated by the bLS model also had a lower multiplicative error and reduced bias relative to GP. Other error-based metrics further confirmed the bLS model performed better, as it yielded lower RMSE and MAE than GP. Statistical analysis of the emission data shows that the lateral and vertical alignment of the source and the sensor plays a critical role in emission estimations, as measurements made closer to the plume centerline and at a distance between 40 and 80 m downwind yielded the best FAC2 agreement. High wind meander degraded the ability of both approaches to generate representative emissions, particularly with the GP approach, as it violates the modeling approach’s assumption of steady-state emissions. Data suggest emissions calculated by the bLS model are comprehensively in better agreement, but the computational demands of the modeling approach and integration into fenceline systems limit real-time applicability. While these results provide insight into model performance under controlled near-field conditions, their applicability to more complex or heterogeneous oil and gas production environments (e.g., the regions Marcellus or Unita Basins) remains limited and uncertain.

gaussian plume↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Doped-LaCrO3 ceramics for high temperature sensor applications

The main objective of this work was to investigate the applicability of the doped-LaCrO3 system for electrical interconnects and sensor applications at temperatures >800°C. Various A- and B-site doping strategies were investigated, and the effect on their electrical conductivity, Seebeck coefficient, and thermal coefficient of expansion were characterized up to 1500ºC. Solid-state, co-precipitation and sol gel methods were used to synthesize the compositions, and the chemical/thermal stability, microstructural evolution, sintering and grain growth kinetics were investigated for these compositions by XRD, SEM and Rietveld methods. The materials showing the greatest promise were included within thick film thermistor and thermocouple sensor designs that were tested to 1500ºC in various gas environments (various pO2 concentrations).

20 FOSSIL-FUELED POWER PLANTS↗

Recent Developments in Sensor Technologies for Enabling the Hydrogen Economy

Efforts to create a sustainable hydrogen economy are gaining momentum as governments all over the world are investing in hydrogen production, storage, distribution, and delivery technologies to develop a hydrogen infrastructure. This involves transporting hydrogen in gaseous or liquid form or using carrier gases such as methane, ammonia, or mixtures of methane and hydrogen. Hydrogen is a colorless, odorless gas and can easily leak into the atmosphere leading to economic loss and safety concerns. Therefore, deployment of robust low-cost sensors for various scenarios involving hydrogen is of paramount importance. Here, we review some recent developments in hydrogen sensors for applications such as leak detection, safety, process monitoring in production, transport and use scenarios. The status of methane and ammonia sensors is covered due to their important role in hydrogen production and transportation using existing natural gas and ammonia infrastructure. This review further provides an overview of existing commercial hydrogen sensors and also addresses the potential for hydrogen as an interferent gas for currently used sensors. This review can help developers and users make informed decisions about how to drive hydrogen sensor technology forward and to incorporate hydrogen sensors into the various hydrogen deployment projects in the coming decade.

08 HYDROGEN↗

Recent Developments in Sensor Technologies for Enabling the Hydrogen Economy

Efforts to create a sustainable hydrogen economy are gaining momentum as governments all over the world are investing in hydrogen production, storage, distribution, and delivery technologies to develop a hydrogen infrastructure. This involves transporting hydrogen in gaseous or liquid form or using carrier gases such as methane, ammonia, or mixtures of methane and hydrogen. Hydrogen is a colorless, odorless gas and can easily leak into the atmosphere leading to economic loss and safety concerns. Therefore, deployment of robust low-cost sensors for various scenarios involving hydrogen is of paramount importance. Here, we review some recent developments in hydrogen sensors for applications such as leak detection, safety, process monitoring in production, transport and use scenarios. The status of methane and ammonia sensors is covered due to their important role in hydrogen production and transportation using existing natural gas and ammonia infrastructure. This review further provides an overview of existing commercial hydrogen sensors and also addresses the potential for hydrogen as an interferent gas for currently used sensors. This review can help developers and users make informed decisions about how to drive hydrogen sensor technology forward and to incorporate hydrogen sensors into the various hydrogen deployment projects in the coming decade.

08 HYDROGEN↗

Coolant Pressure Evaluations for a MEMS Sensor-Array Quench Detection in REBCO CICC Superconducting Cables

Here, the initial quench pressure developments for a CICC cable of REBCO tapes have been investigated by numerical analyzing the first law of thermodynamics. The temperature and pressure rise due to the quench has been evaluated for a REBCO CICC conductor operated in helium gas coolant at 26 K. Additionally, a MEMS sensor-in-tube array method has been proposed and discussed for quench detection.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time monitoring of trace noble gases using laser-induced breakdown spectroscopy—An investigation of the impact of bulk gas on plasma properties and sensitivity

The impact of Ar and He bulk gases on laser-induced breakdown spectroscopy (LIBS) real-time monitoring of trace Xe and Kr was assessed. LIBS is being developed as a monitoring tool for measuring noble gas transport in molten salt systems, in which traditional sensors may face challenges associated with radiation, corrosive materials, and/or mixed phases. The plasma temperature and electron densities of LIBS plasmas were measured in both static and various flowing Ar and He streams (0–5 L min −1 ). The use of an Ar bulk gas resulted in higher plasma temperature, greater electron densities by an order of magnitude, and extended plasma lifetime compared with when He bulk gas was used. Gas flow rate was found to have little impact on plasma temperature; however, its effect on electron density was significant, indicating the need to consider flow rate–specific models. Matrix effects on emission peaks were reported for both bulk gases. Due to these matrix effects, multivariate models were developed for Xe and Kr ranging from 0 to 700 ppm in both bulk gases. Although the predictive behavior was similar (root mean square error of prediction ranging from 11.1 to 20.6 ppm), the limits of detection were superior in He (Xe: 22.9 ppm, Kr: 30.4 ppm). Furthermore, these models were employed in demonstrative real-time tests (>1 h), which showed strong predictive precision (relative standard deviation <5 %) regardless of the bulk gas. Ultimately, this study provides a guide for the considerations required when developing gaseous LIBS models for real-time monitoring.

Gas flow effects↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

Modeling and Design Parameter Optimization to Improve the Sensitivity of a Bimorph Polysilicon-Based MEMS Sensor for Helium Detection

Helium is integral in several industries, including nuclear waste management and semiconductors. Thus, developing a sensing method for detecting helium is essential to ensure the proper operation of such facilities. Several approaches can be used for helium detection, including based on the high thermal conductivity of helium, which is several times higher than air. This work utilizes the high thermal conductivity of helium to design and analyze a bimorph MEMS sensor for helium sensing applications. COMSOL Multiphysics software (version 6.2) is used to carry out this investigation. The sensor is constructed from poly-silicon and SiO 2 materials with a trenched cantilever beam configuration. The sensor is electrically heated, and its morphed displacement depends on the surrounding gas’s composition, which decreases in the presence of helium. Several factors were investigated to probe their effect on the sensor’s sensitivity to helium, including the thickness of the poly-silicon layer, the configuration of the trench, and the thickness and location of SiO 2 layer. The simulations showed that the best performance, up to 2 ppm helium detection level, can be achieved with thinner beams and medium trench lengths.

47 OTHER INSTRUMENTATION↗

Aerosol-Jet Printed Sensors for Environmental, Safety, and Health Monitoring: A Review

An emergent direct-write approach, aerosol-jet printing (AJP), is gaining attention for the deployment of rapid and affordable microadditively manufactured energy-efficient sensors and printed electronics. AJP enables a broad range of ink viscosities (0.001–1 Pa s) for printing diverse materials ranging from ceramics and metals to polymers and biological matter. Reproducible, high-spatial-resolution features (≈10 µm), and wide standoff distances (1–11 mm) between the nozzle and the substrate facilitate conformal printing of complex geometrical designs on nonplanar—e.g., stepped or curved—surfaces. Here this paper aims to provide a comprehensive overview of state-of-the-art AJP-based sensors (e.g., strain and temperature gauges, biosensors, photosensors, humidity and surface acoustic wave sensors, dielectric elastomer actuators, and motion, smoke, and hazardous gas detectors) and to discuss prospective applications. The drive toward cost-effective devices that are smaller, lighter, and better-performing remains a frontier challenge in the field of printed electronics. Consequently, as AJP becomes increasingly utilized in the high-volume manufacturing of miniaturized active and passive sensors, it opens a pathway for facile large-scale fabrication of devices for a wide range of consumer and industrial applications, including transportation, agriculture, infrastructure, aerospace, national defense, and healthcare.

3-dimensional↗

Porous Membranes for Moisture Probe Protection (SR18024)

In the presence of contaminants, moisture probes can give false moisture readings and have shorter lifetimes. Absolute humidity probes are composed of porous, hygroscopic metallic oxide thin films (Al 2 O 3 ) coupled to electrodes (e.g. Au and Al). While these materials provide absolute humidity readings at low water levels at a relatively low cost, they are sensitive to the presence of contaminants, especially ammonia, due to its high hygroscopicity and ability to bind to the probe. Without frequent recalibration, especially in the presence of contaminants, the humidity levels are inaccurately reported due to measurement drift that occurs when the pores close, changing the impedance of the probe. The goal of this project was to improve the stability and reliability of these moisture probes by incorporating a molecular sieve into the probe to allow only the water to reach the sensor. Molecular sieves contain pores that allow molecule specific permeation. Two dimensional inorganic nanosheets (e.g. BN, MoO 2 , MoS 2 ) have recently been shown to behave as molecular sieves for water. Compared to zeolites, nanoporous materials have higher flux rates through the pores, leading to faster water permeation. Graphene oxide sheets have also been successfully employed for unimpeded water permeation; however, at lower humidity levels, the structure is unstable and the pores shrink, preventing the sieving of molecules. Compared to graphene oxide, sheets based off of inorganic materials, such as molybdenum, have been found to be more stable at lower humidity levels and have faster permeation rates. By creating a barrier in before the Al 2 O 3 sensor chip to prevent the permeation of contaminants into the probe, the lifetime of the probe will be extended. While the molybdenum sheets are a promising material for this application, their performance against ammonia and tritiated compounds have not yet been evaluated. This technology can be applied to other applications, including gas and liquid purification for environmental remediation, single molecule sensors, field effect transistors, and catalysts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was approximately 80, 65, 50 and 35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of approximately 95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was approximately 105, 90, 85, 80, and 70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion, using Fe as corrosion proxy, under harsh corrosive environment.

Mainali, Badri↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was ~80, ~65, ~50 and ~35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of ~95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was ~105, ~90, ~85, ~ 80, and ~70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion occurs.

Mainali, Badri↗

Monitor for measuring mercury emissions

A mercury emissions monitor includes a mercury sensor tape configured to be fed in a reel-to-reel manner between first and second tape reels, wherein the mercury sensor tape includes a thin metallic film configured to form an amalgam with detected mercury. A mercury collection unit is configured to receive into a chamber a sample of a gas containing mercury, wherein the mercury collection unit is further configured to permit passage of portions of the mercury sensor tape through the chamber containing the gas sample so that the amalgam is formed with the thin metallic film. A mercury analysis unit includes a total reflection x-ray fluorescence (“TXRF”) system configured to perform a TXRF analysis of the amalgam, wherein the mercury analysis unit is configured to permit passage of the mercury sensor tape within a proximity of an XRF detector of the TXRF system. The mercury collection unit and the mercury analysis unit are positioned between the first and second tape reels so that the mercury sensor tape can move in a continuous manner from the first tape reel through the chamber of the mercury collection unit, then within sufficient proximity to the XRF detector, to be then taken up onto the second tape reel.

Kumar, Nalin↗