Modeling and Design Parameter Optimization to Improve the Sensitivity of a Bimorph Polysilicon-Based MEMS Sensor for Helium Detection

Abstract

Helium is integral in several industries, including nuclear waste management and semiconductors. Thus, developing a sensing method for detecting helium is essential to ensure the proper operation of such facilities. Several approaches can be used for helium detection, including based on the high thermal conductivity of helium, which is several times higher than air. This work utilizes the high thermal conductivity of helium to design and analyze a bimorph MEMS sensor for helium sensing applications. COMSOL Multiphysics software (version 6.2) is used to carry out this investigation. The sensor is constructed from poly-silicon and SiO 2 materials with a trenched cantilever beam configuration. The sensor is electrically heated, and its morphed displacement depends on the surrounding gas’s composition, which decreases in the presence of helium. Several factors were investigated to probe their effect on the sensor’s sensitivity to helium, including the thickness of the poly-silicon layer, the configuration of the trench, and the thickness and location of SiO 2 layer. The simulations showed that the best performance, up to 2 ppm helium detection level, can be achieved with thinner beams and medium trench lengths.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mohaidat, Sulaiman, Alsaleem, Fadi. 2024-06-04. Modeling and Design Parameter Optimization to Improve the Sensitivity of a Bimorph Polysilicon-Based MEMS Sensor for Helium Detection. https://doi.org/10.3390/s24113626

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗