Performance of the PARCS Testbed Cesium Fountain Frequency Standard

A cesium fountain frequency standard has been developed as a ground testbed for the PARCS (Primary Atomic Reference Clock in Space) experiment, an experiment intended to fly on the International Space Station. We report on the performance of the fountain and describe some of the implementations motivated in large part by flight considerations, but of relevance for ground fountains. In particular, we report on a new technique for delivering cooling and trapping laser beams to the atom collection region, in which a given beam is recirculated three times effectively providing much more optical power than traditional configurations. Allan deviations down to 10 have been achieved with this method.

cesium↗

Calibration of the MSL/ChemCam/LIBS Remote Sensing Composition Instrument

The ChemCam instrument suite on board the 2011 Mars Science Laboratory (MSL) Rover, Curiosity, will provide remote-sensing composition information for rock and soil samples within seven meters of the rover using a laser-induced breakdown spectroscopy (LIBS) system, and will provide context imaging with a resolution of 0.10 mradians using the remote micro-imager (RMI) camera. The high resolution is needed to image the small analysis footprint of the LIBS system, at 0.2-0.6 mm diameter. This fine scale analytical capability will enable remote probing of stratigraphic layers or other small features the size of "blueberries" or smaller. ChemCam is intended for rapid survey analyses within 7 m of the rover, with each measurement taking less than 6 minutes. Repeated laser pulses remove dust coatings and provide depth profiles through weathering layers, allowing detailed investigation of rock varnish features as well as analysis of the underlying pristine rock composition. The LIBS technique uses brief laser pulses greater than 10 MW/square mm to ablate and electrically excite material from the sample of interest. The plasma emits photons with wavelengths characteristic of the elements present in the material, permitting detection and quantification of nearly all elements, including the light elements H, Li, Be, B, C, N, O. ChemCam LIBS projects 14 mJ of 1067 nm photons on target and covers a spectral range of 240-850 nm with resolutions between 0.15 and 0.60 nm FWHM. The Nd:KGW laser is passively cooled and is tuned to provide maximum power output from -10 to 0 C, though it can operate at 20% degraded energy output at room temperature. Preliminary calibrations were carried out on the flight model (FM) in 2008. However, the detectors were replaced in 2009, and final calibrations occurred in April-June, 2010. This presentation describes the LIBS calibration and characterization procedures and results, and details plans for final analyses during rover system thermal testing, planned for early March.

Wiens, R. C.↗

Performance and heat transfer characteristics of the laser-heated rocket - A future space transportation system

The application of advanced liquid-bipropellant rocket engine analysis techniques has been utilized for prediction of the potential delivered performance and the design of thruster wall cooling schemes for laser-heated rocket thrusters. Delivered specific impulse values greater than 1000 lbf-sec/lbm are potentially achievable based on calculations for thrusters designed for 10-kW and 5000-kW laser beam power levels. A thruster wall-cooling technique utilizing a combination of regenerative cooling and a carbon-seeded hydrogen boundary layer is presented. The flowing carbon-seeded hydrogen boundary layer provides radiation absorption of the heat radiated from the high-temperature plasma. Also described is a forced convection thruster wall cooling design for an experimental test thruster.

Shoji, J. M.↗

Adaptively controlled fast production of defect-free beryllium ion crystals using pulsed laser ablation

Trapped atomic ions find wide applications ranging from precision measurement to quantum information science and quantum computing. Beryllium ions are widely used due to the light mass and convenient atomic structure of beryllium; however, conventional ion loading from thermal ovens exerts undesirable gas loads for a prolonged duration. Here, we demonstrate a method to rapidly produce pure linear chains of beryllium ions with pulsed laser ablation, serving as a starting point for large-scale quantum information processing. Our method is fast compared to thermal ovens, reduces the gas load to only 10 -12 Torr (10 -10 Pa) level, yields a short recovery time of a few seconds, and also eliminates the need for a deep ultraviolet laser for photoionization. We also study the loading dynamics, which show non-Poissonian statistics in the presence of sympathetic cooling. In addition, we apply feedback control to obtain defect-free ion chains with desirable lengths.

47 OTHER INSTRUMENTATION↗

The Ductility of 49Fe-49Co-2V Soft Magnetic Alloy Bar: Surface Effects and Test Methods

The tensile ductility of 49Fe-49Co-2V (Hiperco® 50A) bar was investigated in both as-received and heat-treated conditions. The as-received/machined specimens exhibit very low ductility compared to samples where heat treatment was the final step prior to testing. Microstructural characterization showed that internal residual strain from bar processing and, most importantly, surface machining damage, cause lower elongation in the as-received material. Because fracture of this intermetallic alloy initiates at the surface, it is particularly susceptible to surface machining damage, i.e., the near-surface region has already exhausted most of its ability to accumulate tensile strain. During heat treatment, the internal residual strain and near-surface machining damage are eliminated and ductility is improved, despite a higher degree of crystallographic ordering in the heat-treated condition (which typically lowers ductility). Furthermore, if machining is again performed after heat treatment, the material again exhibits brittle behavior, even with only light touch-up machining passes. Here, in this work, methods of tensile strain measurement were investigated, namely conventional knife-edge extensometry and noncontact digital image correlation (DIC) on heat-treated material. For clip-on knife-edge extensometry, the range of failure strain was 2.5-5.5% for heat-treated Hiperco. For noncontact methods, ductility up to 7% was observed. The results highlight the tendency for the alloy to fail at surface imperfections, even those produced by application of the extensometer itself. Noncontact laser extensometry is recommended for determining the intrinsic ductility of the alloy. A method of laser surface modification was developed which increased ductility by ~ 100% compared to unmodified samples. The high cooling rates achieved during laser surface processing can bypass the ordering reaction and produce a ductile disordered structure at the surface that exhibits ductile fracture characteristics.

EBSD↗

Qualification of Laser Diode Arrays for Mercury Laser Altimeter Mission

NASA's requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. The MESSENGER mission is flying the Mercury Laser Altimeter (MLA) which is a diode-pumped Nd:YAG laser instrument designed to map the topography of Mercury. The environment imposed on the instrument by the orbital dynamics places special requirements on the laser diode arrays. In order to limit the radiative heating of the satellite from the surface of Mercury, the satellite is designed to have a highly elliptical orbit. The satellite will heat near perigee and cool near apogee. The laser power is cycled during these orbits so that the laser is on for only 30 minutes (perigee) in a 12 hour orbit. The laser heats 10 C while powered up and cools while powered down. In order to simulate these operational conditions, we designed a test to measure the LDA performance while being temperature and power cycled. Though the mission requirements are specific to NASA and performance requirements are derived from unique operating conditions, the results are general and widely applicable. We present results on the performance of twelve LDAs operating for several hundred million pulses. The arrays are 100 watt, quasi-CW, conductively-cooled, 808 nm devices. Prior to testing, we fully characterize each device to establish a baseline for individual array performance and status. Details of this characterization can be found in reference. Arrays are divided into four groups and subjected to the temperature and power cycling matrix are shown.

Stephen, Mark↗

New Techniques to Test Spin-Gravity Coupling with Atomic Clock

Recent advances in laser technology have produced the opportunity to realize more stable and accurate atomic clocks, by laser excitation, manipulation and cooling of atoms. In this paper we will describe a new scheme based on the use of lasers with atomic clocks to increase the sensitivity of experimental search for a spin-gravity coupling.

atomic clocks↗

Laser Incident in the NASA Unitary Plan Wind Tunnel

A viewgraph presentation describing the laser incident in the NASA Unitary Plan Wind Tunnel (UPWT) is shown. The topics include: 1) Unitary Plan Wind Tunnel (UPWT); 2) UPWT 11' x 11' Transonic Wind Tunnel; 3) UPWT 9' x 7' Supersonic Wind Tunnel; 4) 3D Particle Image Velocimetry (PIV); 5) PIV System in 11' x 11' Transonic Test Section; 6) PIV installation in 11' x 11' TWT; 7) 3% Space Shuttle Ascent Configuration Test in UPWT 9' x 7' Test Section; 8) PIV installation in 9' x 7' SWT; 9) PIV Laser System in 9' x 7' SWT; 10) PIV Laser System Access Window; 11) Cooling Water Leak at Rear of Power Supply; 12) PIV Laser Safety Interlock System; 13) Safety Interlock Cable; 14) Q-Switch located on top of 9' x 7' Test Section; 15) Investigation Findings and Recommendations; and 16) PIV Results for 3% Space Shuttle Model in UPWT 9' x 7'.

George, Michael W.↗

Exploring mounting solutions for cryogenically cooled thin crystal optics in high power density x-ray free electron lasers

This study investigates three mounting methods—clamping, soldering, and a hybrid clamping–soldering approach—for cryogenically cooled thin diamond crystals crucial to stable operation of X-ray Free Electron Laser (XFEL) systems. While clamping methods exhibit temperature resilience and flexibility, meticulous design is required to prevent stress-induced warping and reduce thermal contact area. Soldering methods offer reliable mechanical and thermal bonding but encounter challenges due to the coefficient of thermal expansion mismatch at cryogenic temperatures. The hybrid method, integrating clamping and soldering with strain relief cuts, effectively mitigates overall distortion caused by mounting and XFEL thermal loads. These findings offer a novel mounting solution for high-performance x-ray optics in XFEL research and applications, ensuring stability and optimal functionality in cryogenic conditions.

Instruments & Instrumentation↗

Laser Patterning Assisted Devitrification and Domain Engineering of Amorphous and Nanocrystalline Alloys

We have investigated laser-patterning and devitrification as a novel method to realize emergent properties in modified regions at the ribbon surface consisting of periodic localized laser spots thermally treated under rapid heating and cooling conditions. Fe-based amorphous ribbons were annealed for systematically varied laser power. Extremely high heating and cooling rates on the order of 10(exp 8)-10(exp 10)K/s have been estimated by finite element analysis simulations. Observations suggest surface melting followed by rapid solidification fast enough to quench and form an amorphous structure upon cooling. Diffusion of heat occurs from the laser irradiated surface region so that a finite volume of material surrounding this region rises in temperature above the crystallization temperature relevant for conventional isothermal annealing experiments. The underlying mechanism of laser annealing and consequences of heat transients involved are discussed in terms of impacts upon micro/nanostructure, residual stresses, and magnetic domain structure surrounding the laser irradiated region. The study illustrates the potential to exploit spatially optimized phase transformations in a scalable manufacturing process of amorphous and nanocrystalline alloys to locally access otherwise inaccessible extreme heating and cooling rates.

Amorphous ribbons↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

Advanced and Additive Manufacturing Technologies for Liquid Rocket Engine Components

Overview of advanced manufacturing and additive manufacturing development at NASA for liquid rocket engines. Presentation includes various material, process, design, and hot-fire testing developments demonstrating the use of advanced components for liquid rocket engines on launch vehicles and in-space systems.

Additive Manufacturing↗

"Application of Tunable Diode Laser Spectrometry to Isotopic Studies for Exobiology"

Computer-controlled electrically-activated valves for rapid gas-handling have been incorporated into the Stable Isotope Laser Spectrometer (SILS) which now permits rapid filling and evacuating of the sample and reference gas cells, Experimental protocols have been developed to take advantage of the fast gas handling capabilities of the instrument and to achieve increased accuracy which results from reduced instrumental drift during rapid isotopic ratio measurements. Using these protocols' accuracies of 0.5 del (0.05%) have been achieved in measurements of 13C/12C in carbon dioxide. Using the small stable isotope laser spectrometer developed in a related PIDDP project of the Co-I, protocols for acquisition of rapid sequential calibration spectra were developed which resulted in 0.5 del accuracy also being achieved in this less complex instrument. An initial version of software for automatic characterization of tunable diode lasers has been developed and diodes have been characterized in order to establish their spectral output properties. A new state-of-the-art high operating temperature (200 K) mid infrared diode laser was purchased (through NASA procurement) and characterized. A thermo-electrically cooled mid infrared tunable diode laser system for use with high temperature operation lasers was developed. In addition to isotopic ratio measurements of carbon and oxygen, measurements of a third biologically important element (15N/14N in N2O gas) have been achieved to a preliminary accuracy of about 0.2%. Transfer of the basic SILS technology to the commercial sector is proceeding under an unfunded Space Act Agreement between NASA and SpiraMed, a medical diagnostic instrument company. Two patents have been issued. Foreign patents based on these two US patents have been applied for and are expected to be issued. A preliminary design was developed for a thermo-electrically cooled SILS instruments for application to planetary space flight exploration missions.

Sauke, Todd B.↗

Single-mode, All-Solid-State Nd:YAG Laser Pumped UV Converter

In this paper, the status of a high-energy, all solid-state Nd:YAG laser pumped nonlinear optics based UV converter development is discussed. The high-energy UV transmitter technology is being developed for ozone sensing applications from space based platforms using differential lidar technique. The goal is to generate greater than 200 mJ/pulse with 10-50 Hz PRF at wavelengths of 308 nm and 320 nm. A diode-pumped, all-solid-state and single longitudinal mode Nd:YAG laser designed to provide conductively cooled operation at 1064 nm has been built and tested. Currently, this pump laser provides an output pulse energy of >1 J/pulse at 50 Hz PRF and a pulsewidth of 22 ns with an electrical-to-optical system efficiency of greater than 7% and a M(sup 2) value of <2. The single frequency UV converter arrangement basically consists of an IR Optical Parametric Oscillator (OPO) and a Sum Frequency Generator (SFG) setups that are pumped by 532 nm wavelength obtained via Second Harmonic Generation (SHG). In this paper, the operation of an inter cavity SFG with CW laser seeding scheme generating 320 nm wavelength is presented. Efforts are underway to improve conversion efficiency of this mJ class UV converter by modifying the spatial beam profile of the pump laser.

Prasad, Narasimha S.↗

Neutron Characterization of 3D Printed Gas Turbine Alloy With Internal Cooling Structure

The objective of this research work is to investigate the residual strains induced by the presence of a exit hole and internal hollow geometry present in a 3D printed IN718 similar to that seen in a gas turbine blade. The specimens were manufactured with an internal hollow structure that ended with an exit hole, and fabricated by direct metal laser sintering additive manufacturing technique. Using this technique, metal powder was melted by a laser source and rapidly cooled to form the part layer by layer. Rapid heating and cooling generate large thermal gradients and residual stresses in the 3D printed material. To be aligned with industry standards, specimens were heat-treated to relieve most of the residual stresses as well as to investigate whether IN718 still preserved a nonhomogeneous stress state after the thermal treatment. Roughness and microstructure analysis was performed to understand the heat-treated sample properties. To investigate the volumetric residual strain, the neutron diffraction technique was used with a definite neutron wavelength. Bragg’s law was used to determine lattice spacing. Interplanar lattice spacing and stress-free state lattice spacings were measured to calculate the strains. Residual strains were measured in the x and y direction to understand the impact of the presence of a exit hole and internal hollow geometry. The results of volumetric residual strain in the x and y directions showed no significant variations in the distribution of the strain due to the presence of a hollow structure as well as the exit hole. Overall, no significant stress concentration was observed in the heat treated sample. Sample geometry, instrumentation for neutron diffraction, and material properties are discussed in detail in this paper.

Raju, Nandhini↗

Analysis of sublimation-cooled coated mirrors in convective and radiative environments.

Analytical solutions were obtained for the thermal response of a transpiration- or sublimation-cooled spherical mirror coating exposed to convective and radiative heating. The solutions allow unlimited spectral detail to be accounted for. Results indicate that transpiration-cooled thick coatings (1 cm) may withstand up to 10 kW/sq cm on a steady basis without excessive temperature rise for quartzlike materials with an internal absorption coefficient of 0.01 per cm. On a transient basis, fluxes up to 20 kW/sq cm can be accommodated for a second (cW laser exposure time), 4 kW/sq cm for 5 sec (planetary entry heating time), and of the order of MW/sq cm for millisecond times (short-duration laser bursts) without transpiration cooling for a material with an absorption coefficient of 0.1 per cm. Proportionately higher fluxes can be accommodated with lower absorption coefficients. Thermal stresses produced by the heat pulse are found to be high but within the strength of the materials. The regime in which meaningful solutions may be obtained is mapped in detail.

Howe, J. T.↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗