Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mars Science (MSL) Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Rover Low Gain Antenna Qualification for Deep Space Thermal Environments

A method to qualify the Rover Low Gain Antenna (RLGA) for use during the Mars Science Laboratory (MSL) mission has been devised. The RLGA antenna must survive all ground operations, plus the nominal 670 Martian sol mission that includes the summer and winter seasons of the Mars thermal environment. This qualification effort was performed to verify that the RLGA design, its bonding, and packaging processes are adequate. The qualification test was designed to demonstrate a survival life of three times more than all expected ground testing, plus a nominal 670 Martian sol missions. Baseline RF tests and a visual inspection were performed on the RLGA hardware before the start of the qualification test. Functional intermittent RF tests were performed during thermal chamber breaks over the course of the complete qualification test. For the return loss measurements, the RLGA antenna was moved to a test area. A vector network analyzer was calibrated over the operational frequency range of the antenna. For the RLGA, a simple return loss measurement was performed. A total of 2,010 (3 670 or 3 times mission thermal cycles) thermal cycles was performed. Visual inspection of the RLGA hardware did not show any anomalies due to the thermal cycling. The return loss measurement results of the RLGA antenna after the PQV (Package Qualification and Verification) test did not show any anomalies. The antenna pattern data taken before and after the PQV test at the uplink and downlink frequencies were unchanged. Therefore, the developed design of RLGA is qualified for a long-duration MSL mission.

Ramesham, Rajeshuni↗

Chemical and Mineralogical Characterization of a Hematite-bearing Ridge on Mauna Kea, Hawaii: A Potential Mineralogical Process Analog for the Mount Sharp Hematite Ridge

The Mars Science Laboratory (MSL) rover Curiosity landed in Gale Crater in August 2012 and is currently roving towards the layered central mound known as Mount Sharp [1]. Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) hyperspectral data indicate Mount Sharp contains an ~5 km stratigraphic sequence including Fe-Mg smectites, hematite, and hydrated sulfates in the lower layers separated by an unconformity from the overlying anhydrous strata [1,2,3]. Hematite was initially detected in CRISM data to occur in the lower sulfate layers on the north side of the mound [2]. [3] further mapped a distinct hematite detection occurring as part of a ~200 m wide ridge that extends ~6.5 km NE-SW, approximately parallel with the base of Mount Sharp. It is likely a target for in-situ analyses by Curiosity. We document here the occurrence of a stratum of hematite-bearing breccia that is exposed on the Puu Poliahu cinder cone near the summit of Mauna Kea volcano (Hawaii) (Fig.1). The stratum is more resistant to weathering than surrounding material, giving it the appearance of a ridge. The Mauna Kea hematite ridge is thus arguably a potential terrestrial mineralogical and process analog for the Gale Crater hematite ridge. We are acquiring a variety of chemical and mineralogical data on the Mauna Kea samples, with a focus on the chemical and mineralogical information already available or planned for the Gale hematite ridge.

Graff, T. G.↗

Mass Spectrometry on Future Mars Landers

Mass spectrometry investigations on the 2011 Mars Science Laboratory (MSL) and the 2018 ExoMars missions will address core science objectives related to the potential habitability of their landing site environments and more generally the near-surface organic inventory of Mars. The analysis of complex solid samples by mass spectrometry is a well-known approach that can provide a broad and sensitive survey of organic and inorganic compounds as well as supportive data for mineralogical analysis. The science value of such compositional information is maximized when one appreciates the particular opportunities and limitations of in situ analysis with resource-constrained instrumentation in the context of a complete science payload and applied to materials found in a particular environment. The Sample Analysis at Mars (SAM) investigation on MSL and the Mars Organic Molecule Analyzer (MOMA) investigation on ExoMars will thus benefit from and inform broad-based analog field site work linked to the Mars environments where such analysis will occur.

Brinckerhoff, W. B.↗

Searching for Reduced Carbon on the Surface of Mars: The SAM Combustion Experiment

The search for reduced carbon has been a major focus of past and present missions to Mars. Thermal evolved gas analysis was used by the Viking and Phoenix landers and is currently in use by the Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) to characterize volatiles evolved from solid samples, including those associated with reduced organic species. SAM has the additional capability to perform a combustion experiment, in which a sample of Mars regolith is heated in the presence of oxygen and the composition of the evolved gases is measured using quadrupole mass spectrometry (QMS) and tunable laser spectrometry (TLS) [1]. Organics detection on the Martian surface has been complicated by oxidation and destruction during heating by soil oxidants [2], including oxychlorine compounds, and terrestrial organics in the SAM background contributed by one of the SAM wet chemistry reagents MTBSTFA (N-Methyl-N-tertbutyldimethylsilyl- trifluoroacetamide) [3,4]. Thermal Evolved Gas Analysis (TEGA) results from Phoenix show a mid temperature CO2 release between 400 C - 680 C speculated to be carbonate, CO2 adsorbed to grains, or combustion of organics by soil oxidants [5]. Low temperature CO2 evolutions (approx. 200 C - 400 C) were also present at all three sites in Gale Crater where SAM Evolved Gas Analysis (EGA) was performed, and potential sources include combustion of terrestrial organics from SAM, as well as combustion and/or decarboxylation either indigenous martian or exogenous organic carbon [4,6]. By performing an experiment to intentionally combust all reduced materials in the sample, we hope to compare the bulk abundance of CO2 and other oxidized species evolved by combustion to that evolved during an EGA experiment to estimate how much CO2 could be contributed by reduced carbon sources. In addition, C, O, and H isotopic compositions of CO2 and H2O measured by TLS can contribute information regarding the potential sources of these volatiles.

Stern, J. C.↗

Isotopic Composition of Carbon Dioxide Released from Confidence Hills Sediment as Measured by the Sample Analysis at Mars (SAM) Quadrupole Mass Spectrometer

In October 2014, the Mars Science Laboratory (MSL) "Curiosity" rover drilled into the sediment at the base of Mount Sharp in a location namsed Cionfidence Hills (CH). CH marked the fifth sample pocessed by the Sample Analysis at Mars (SAM) instrument suite since Curiosity arrived in Gale Crater, with previous analyses performed at Rocknest (RN), John Klein (JK), Cumberland (CB), and Windjana (WJ). Evolved gas analysis (EGA) of all samples has indicated H2O as well as O-, C- and S-bearing phases in the samples, often at abundances that would be below the detection limit of the CheMin instrument. By examining the temperatures at which gases are evolved from samples, SAM EGA data can help provide clues to the mineralogy of volatile-bearing phases when their identities are unclear to CheMin. SAM may also detect gases evolved from amorphous material in solid samples, which is not suitable for analysis by CheMin. Finally, the isotopic composition of these gases may suggest possible formation scenarios and relationships between phases. We will discuss C isotope ratios of CO2 evolved from the CH sample as measured with SAM's quadrupole mass spectrometer (QMS) and draw comparisons to samples previously analyzed by SAM.

Franz, H. B.↗

Detection of Siderite (FeCO3) in Glen Torridon Samples by the Mars Science Laboratory Rover

Siderite (FeCO3) has been detected in Gale Crater for the first time by the Mars Science Laboratory (MSL) Curiosity and is seen in multiple samples in the Glen Torridon (GT) region. The identification of siderite is based on evolved gas analysis (EGA) data from the Sample Analysis at Mars (SAM) instrument and X-ray diffraction (XRD) data from the Chemistry and Mineralogy (CheMin) instrument. Curiosity descended off of the Vera Rubin ridge (VRR) into the Glen Torridon region on Sol 2300. Glen Torridon is of particular interest because a strong clay mineral signature had been detected by orbital instruments [1]. To date, four drilled samples have been collected at two different drill locations: Kilmarie and Aberlady from adjacent blocks at the base of the south side of VRR in the Jura member and Glen Etive 1 and 2 on the same block in the Knockfarril member.

Archer, P. D.↗

In Situ Analysis of Martian Phyllosilicates Using the Chemin Minerological Instrument on Mars Science Laboratory

The CheMin minerological instrument on Mars Science Laboratory (MSL'09) [1] will return quantitive Xray diffraction data (XRD) and quantative X-ray fluorescence data (XRF;14<Z<92) from scooped soil samples and drilled rock powders collected from the Mars surface. Samples of 45-65 mm 3 from material sieved to less than 150 micrometers will be delivered through a funnel to one of 27 reusable sample cells (five additional cells on the sample wheel contain diffraction of fluorescence standards). Sample cells are 8-mm diamater discs with 7-micrometer thick Mylar or Kapton windows spaced 170 micrometers apart. Within this volume, the sample is shaken by piezoelectric vibration at sonic frequencies, causing the powder to flow past a narrow, collimated -ray beam in random orientation can be obtained even from minnerals exhibiting strong preferred orientation such as phylosilicates.

Blake, David F.↗

Analysis of MSL/MEDLI Entry Data with Coupled CFD and Material Response

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on OpenFOAM (PATO) [4,5,6] using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA [7], is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Thermal Protection Systems↗

Fluorocarbon Contamination from the Drill on the Mars Science Laboratory: Potential Science Impact on Detecting Martian Organics by Sample Analysis at Mars (SAM)

Polytetrafluoroethylene (PTFE or trade name: Teflon by Dupont Co.) has been detected in rocks drilled during terrestrial testing of the Mars Science Laboratory (MSL) drilling hardware. The PTFE in sediments is a wear product of the seals used in the Drill Bit Assemblies (DBAs). It is expected that the drill assembly on the MSL flight model will also shed Teflon particles into drilled samples. One of the primary goals of the Sample Analysis at Mars (SAM) instrument suite on MSL is to test for the presence of martian organics in samples. Complications introduced by the potential presence of PTFE in drilled samples to the SAM evolved gas analysis (EGA or pyrolysisquadrupole mass spectrometry, pyr-QMS) and pyrolysis- gas chromatography mass spectrometry (Pyr- GCMS) experiments was investigated.

fluorocarbon contamination↗

Detection Limit of Smectite by Chemin IV Laboratory Instrument: Preliminary Implications for Chemin on the Mars Science Laboratory Mission

The CheMin instrument on the Mars Science Laboratory (MSL) is an miniature X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of detecting the mineralogical and elemental compositions of rocks, outcrops and soils on the surface of Mars. CheMin uses a microfocus-source Co X-ray tube, a transmission sample cell, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CRISM and OMEGA have identified the presence of phyllosilicates at several locations on Mars including the four candidate MSL landing sites. The objective of this study was to conduct preliminary studies to determine the CheMin detection limit of smectite in a smectite/olivine mixed mineral system.

Archilles, Cherie↗

Effects of Kapton Sample Cell Windows on the Detection Limit of Smectite: Implications for CheMin on the Mars Science Laboratory Mission

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CheMin has two different window materials used for sample cells -- Mylar and Kapton. Instrument details are provided elsewhere. Fe/Mg-smectite (e.g., nontronite) has been identified in Gale Crater, the MSL future landing site, by CRISM spectra. While large quantities of phyllosilicate minerals will be easily detected by CheMin, it is important to establish detection limits of such phases to understand capabilities and limitations of the instrument. A previous study indicated that the (001) peak of smectite at 15 Ang was detectable in a mixture of 1 wt.% smectite with olivine when Mylar is the window material for the sample cell. Complications arise when Kapton is the window material because Kapton itself also has a diffraction peak near 15 Ang (6.8 deg 2 Theta). This study presents results of mineral mixtures of smectite and olivine to determine smectite detection limits for Kapton sample cells. Because the intensity and position of the smectite (001) peak depends on the hydration state, we also analyzed mixtures with "hydrated" and "dehydrated"h smectite to examine the effects of hydration state on detection limits.

Achilles, C. N.↗

X-Ray Diffraction Reference Intensity Ratios of Amorphous and Poorly Crystalline Phases: Implications for CheMin on the Mars Science Laboratory

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. Piezoelectric vibration of the cell is used to randomize the sample to reduce preferred orientation effects. Instrument details are provided in [1, 2, 3]. Analyses of rock and soil samples by the Mars Exploration Rovers (MER) show nanophase ferric oxide (npOx) is a significant component of the Martian global soil [4] and is thought to be one of the major contributing phases that the Curiosity rover will encounter if a soil sample is analyzed in Gale Crater. Because of the nature of this material, npOx will likely contribute to an X-ray amorphous or short-order component of a XRD pattern measured by the CheMin instrument.

Morris, R. V.↗

Determination of Aerothermal Environment and Ablator Material Response Using Inverse Methods

The Mars Science Laboratory (MSL) was protected during entry into the Martian atmosphere by a thermal protection system that used NASA’s Phenolic Impregnated Carbon Ablator (PICA). The heat shield of the probe was instrumented with the Mars Entry Descent and Landing Instrument (MEDLI) suite of sensors. MEDLI Integrated Sensor Plugs (MISP) included thermocouples that measured in-depth temperatures at various locations on the heatshield. The flight data has been used as a benchmark for validating ablation codes within NASA. This work seeks to refine the estimate of the material properties for the MSL heat shield and the aerothermal environment during Mars entry using estimation methods in DAKOTA on the temperature data obtained from MEDLI.

Thornton, John M.↗

ANALYSIS OF THE MSL/MEDLI ENTRY DATA WITH COUPLED CFD AND MATERIAL RESPONSE.

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heat-shield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material. PICA is a lightweight carbon fiber/polymeric resin material that offers out-standing performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on Open-FOAM (PATO) using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA, is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Mars Science Laboratory↗

The Sample Analysis at Mars Investigation and Instrument Suite

The Sample Analysis at Mars (SAM) investigation of the Mars Science Laboratory (MSL) addresses the chemical and isotopic composition of the atmosphere and volatiles extracted from solid samples. The SAM investigation is designed to contribute substantially to the mission goal of quantitatively assessing the habitability of Mars as an essential step in the search for past or present life on Mars. SAM is a 40 kg instrument suite located in the interior of MSL's Curiosity rover. The SAM instruments are a quadrupole mass spectrometer, a tunable laser spectrometer, and a 6-column gas chromatograph all coupled through solid and gas processing systems to provide complementary information on the same samples. The SAM suite is able to measure a suite of light isotopes and to analyze volatiles directly from the atmosphere or thermally released from solid samples. In addition to measurements of simple inorganic compounds and noble gases SAM will conduct a sensitive search for organic compounds with either thermal or chemical extraction from sieved samples delivered by the sample processing system on the Curiosity rover's robotic arm,

Mahaffy, Paul↗

In Situ Strategy of the 2011 Mars Science Laboratory to Investigate the Habitability of Ancient Mars

The ten science investigations of the 2011 Mars Science Laboratory (MSL) Rover named "Curiosity" seek to provide a quantitative assessment of habitability through chemical and geological measurements from a highly capable robotic' platform. This mission seeks to understand if the conditions for life on ancient Mars are preserved in the near-surface geochemical record. These substantial payload resources enabled by MSL's new entry descent and landing (EDL) system have allowed the inclusion of instrument types nevv to the Mars surface including those that can accept delivered sample from rocks and soils and perform a wide range of chemical, isotopic, and mineralogical analyses. The Chemistry and Mineralogy (CheMin) experiment that is located in the interior of the rover is a powder x-ray Diffraction (XRD) and X-ray Fluorescence (XRF) instrument that provides elemental and mineralogical information. The Sample Analysis at Mars (SAM) suite of instruments complements this experiment by analyzing the volatile component of identically processed samples and by analyzing atmospheric composition. Other MSL payload tools such as the Mast Camera (Mastcam) and the Chemistry & Camera (ChemCam) instruments are utilized to identify targets for interrogation first by the arm tools and subsequent ingestion into SAM and CheMin using the Sample Acquisition, Processing, and Handling (SA/SPaH) subsystem. The arm tools include the Mars Hand Lens Imager (MAHLI) and the Chemistry and Alpha Particle X-ray Spectrometer (APXX). The Dynamic Albedo of Neutrons (DAN) instrument provides subsurface identification of hydrogen such as that contained in hydrated minerals

Mahaffy, Paul R.↗

Rock Hard Science: Multispectral and Mineralogical Investigations to Understand Bedrock Spectral Properties and Strength at Vera Rubin Ridge, Gale Crater, Mars

Since the beginning of the Mars Science Laboratory (MSL) mission, Vera Rubin Ridge (VRR) has been a location of interest to the MSL science team because of its apparent erosional resistance and strong near-IR (~860 nm) absorption feature seen from orbit in the Mars Reconnaissance Orbiter mission's Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) data. The strong CRISM absorption feature along VRR was hypothesized to be primarily associated with an increased abundance of crystal-line hematite compared to lower Mt. Sharp units. How-ever, surface multispectral and mineralogic data, from the Mastcam and CheMin instruments onboard the Curiosity rover, suggest hematite is not the only mineral contributing to the near-IR absorption feature measured in VRR or the reason for its relative hardness.

Jacob, S. R.↗

Constraints on Mars Aphelion Cloud Belt phase function and ice crystal geometries

This study constrains the lower bound of the scattering phase function of Martian water ice clouds (WICs) throughthe implementation of a new observation aboard the Mars Science Laboratory (MSL). The Phase Function SkySurvey (PFSS) was a multiple pointing all-sky observation taken with the navigation cameras (Navcam) aboardMSL. The PFSS was executed 35 times during the Aphelion Cloud Belt (ACB) season of Mars Year 34 over a solarlongitude range of Ls = 61:4 156:5. Twenty observations occurred in the morning hours between 06:00 and 09:30 LTST, and 15 runs occurred in the evening hours between 14:30 and 18:00 LTST, with an operationallyrequired 2.5 h gap on either side of local noon due the sun being located near zenith. The resultant WIC phasefunction was derived over an observed scattering angle range of 18.3-152.61, normalized, and compared with 9modeled phase functions: seven ice crystal habits and two Martian WIC phase functions currently being implementedin models. Through statistical chi-squared probability tests, the five most probable ice crystal geometriesobserved in the ACB WICs were aggregates, hexagonal solid columns, hollow columns, plates, and bullet rosetteswith p-values greater than or equal to 0.60, 0.57,0.56,0.56, and 0.55, respectively. Droxtals and spheres had pvaluesof 0.35, and 0.2, making them less probable components of Martian WICs, but still statistically possibleones. Having a better understanding of the ice crystal habit and phase function of Martian water ice cloudsdirectly benefits Martian climate models which currently assume spherical and cylindrical particles.

Cooper, Brittney↗