Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARTICLE COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

249 records · Page 14

Reduced bandwidth Compton photons from a laser-plasma accelerator using tailored plasma channels

It has been demonstrated experimentally that laser plasma accelerators can produce multi-100 MeV electron bunches with a few percent energy spread, and from these electrons, multi-MeV quasi-monoenergetic photons have been demonstrated based on Compton up-scattering from a counter-propagating laser. This offers the potential of a high-quality, narrow-bandwidth, compact, photon source with broad application. The bandwidth of the resulting photons depends directly on the distribution of the electron bunch and is limited, in particular, by the bunch divergence (i.e., the spread in transverse velocity angle). At the same time, the ability to decelerate electrons after scattering is important to source deployment. We describe a series of plasma structures that expand and then collimate the electron bunch, reducing its divergence and thus reducing the bandwidth of the scattered photons while enabling both high performance scattering and deceleration. Furthermore, these plasma structures are demonstrated in simulations of the accelerator system, showing the potential to reach few-percent photon spread which is important for applications using nuclear resonance fluorescence.

42 ENGINEERING↗

Exploring solar neutrino oscillation parameters with the liquid scintillator counter at Yemilab with a comparison to JUNO

We investigate the sensitivities of the liquid scintillator counter (LSC) at Yemilab and JUNO to solar neutrino oscillation parameters, focusing on θ 12 and Δ m 21 2 . We compare the potential of JUNO with LSC at Yemilab utilizing both reactor and solar data in determining those parameters. We find that the solar neutrino data of LSC at Yemilab is highly sensitive to θ 12 enabling its determination with a higher precision compared to reactor experiments. Our study also reveals that if Δ m 21 2 is larger, with a value close to the best-fit value of KamLAND, JUNO reactor data will have about two times better precision than the reactor LSC at Yemilab. On the other hand, if Δ m 21 2 is smaller and closer to the best-fit value of solar neutrino experiments, the precision of the reactor LSC at Yemilab will be better than JUNO. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measuring the growth of Alfvén wave parametric decay instability using counter-propagating waves: Theory and simulations

The parametric decay instability (PDI) of Alfvén waves—where a pump Alfvén wave decays into a backward-propagating child Alfvén wave and a forward ion acoustic wave—is a fundamental nonlinear wave-wave interaction and holds significant implications for space and laboratory plasmas. However, to date there has been no direct experimental measurement of PDI. Here, we propose a novel and experimentally viable scheme to quantify the growth of Alfvén wave PDI on a linear device using a large pump Alfvén wave and a small counter-propagating seed Alfvén wave, with the seed-wave frequency tuned to match the backward Alfvén wave generated by standard PDI. Using hybrid simulations, we show that energy transfer from the pump to the seed reduces the latter's spatial damping. By comparing seed-wave amplitudes with and without the pump wave, this damping reduction can be used as a direct and reliable proxy for PDI growth. The method is validated in our simulations across a range of plasma and wave parameters and agrees well with theoretical predictions. Notably, the scheme exhibits no threshold for PDI excitation and is, in principle, readily implementable under current laboratory conditions. Finally, this scheme is a critical step toward solving the challenge of experimentally accessing Alfvén wave PDI and provides an elegant method that may be used to validate fundamental theories of parametric instabilities in controlled laboratory settings.

heliosphere↗

Search for electron-neutrino transitions to sterile states in the BEST experiment

The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the 71 Ge production rates within the two zones, as well as a possible rate difference between the zones. From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi 51 Cr neutrino source 10 times for a total of 20 independent 71 Ge extractions from the two Ga targets. The 71 Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with 71 Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured 71 Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the 4⁢𝜎 deviations from unity consistent with the previously reported gallium anomaly. Finally, if interpreted in the context of neutrino oscillations, the deficits give best-fit oscillation parameters of Δ⁢𝑚 2 = 3.3$^{+∞}{−2.3}$ eV 2 and sin 2 ⁡2⁢𝜃 = 0.42$^{+0.15}{−0.17}$, consistent with 𝜈 𝑒 →𝜈 𝑠 oscillations governed by a surprisingly large mixing angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of humidity sensitivity of silicon strip sensors for ATLAS upgrade tracker, pre- and post-irradiation

During the prototyping phase of the new ATLAS Inner-Tracker (ITk) strip sensors, a degradation of the device breakdown voltage at high humidity was observed. Although the degradation was temporary, showing a fast recovery in dry conditions, the study of the influence of humidity on the sensor performance was critical to establish counter-measures and handling protocols during production testing in order to ensure the proper performance of the upgraded detector. The work presented here has the objective to study for the first time the breakdown voltage deterioration in presence of ambient humidity of ATLAS ITk production-layout strip sensors with different surface properties, before and after proton, neutron and gamma irradiations. A study of the humidity sensitivity of miniature ATLAS ITk strip sensors, before and after proton irradiations, is also presented to compare the sensitivity of devices with different sizes. The sensors were also exposed for several days to high humidity with the aim to recreate and evaluate the influence of the detector integration environment expected during the Large Hadron Collider (LHC) Long Shutdown 3 (LS3) in 2026, where the sensors will be exposed to ambient humidity for prolonged times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel plasma actuator for mitigation of dynamic stall

A novel plasma actuator, the Linear Counter-flow using a Point Embedded Electrode (LCPEE), is developed for the prevention of dynamic stall for a sinusoidal pitching movement between α = 4° and α = 18°. The LCPEE is implemented on a NACA0012 airfoil and tested at a Reynolds Number of Re c = 2 × 105 and reduced frequency of k = π/16. Prior investigations using a standard linear actuator showed that the exposed electrode introduced perturbations passively which delayed dynamic stall when the actuator was off. For the LCPEE actuator, when turned off, there is least passive delay. When the LCPEE is turned on at St f = 50, the dynamic stall is prevented for the sinusoidal pitching motion of the airfoil. The LCPEE actuator is also tested for the same sinusoidal motion between α = 6° and α = 20°. Four cases are considered for the higher α range of motion: actuator off, actuator on at St f = 50 with a sinusoidal input waveform, actuator on at St f = 50 with a triangular input waveform, and actuator on at Stf = 100 with a sinusoidal input waveform. Specifically for the last case, experiment shows no flow reversal demonstrating the efficacy of LCPEE in controlling the dynamic stall. The effects of LCPEE on the flow energy distribution have also been studied by using proper orthogonal decomposition (POD) method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ Decay at the J-PARC KOTO Experiment

We performed a search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ decay using the data taken in 2021 at the J-PARC KOTO experiment. With newly installed counters and new analysis method, the expected background was suppressed to 0.252 ± 0.055 stat ⁢ $^{+0.052}_{{−0.067^{syst}}}$. With a single event sensitivity of (9.33 ± 0.0⁢6 stat ±0.8⁢4 syst ) × 10 −10 , no events were observed in the signal region. An upper limit on the branching fraction for the decay was set to be 2.2 ×10 −9 at the 90% confidence level (C.L.), which improved the previous upper limit from KOTO by a factor of 1.4. With the same data, a search for 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was also performed, where 𝑋 0 is an invisible boson with a mass ranging from 1 to 260 MeV/𝑐 2 . For 𝑋 0 with a mass of 135 MeV/𝑐 2 , an upper limit on the branching fraction of 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was set to be 1.6 ×10 −9 at the 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a new CEDAR for kaon identification at the NA62 experiment at CERN

The NA62 experiment at CERN utilises a differential Cherenkov counter with achromatic ring focus (CEDAR) for tagging kaons within an unseparated monochromatic beam of charged hadrons. The CEDAR-H detector was developed to minimise the amount of material in the path of the beam by using hydrogen gas as the radiator medium. The detector was shown to satisfy the kaon tagging requirements in a test-beam before installation and commissioning at the experiment. The CEDAR-H performance was measured using NA62 data collected in 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗