Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)

The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculating a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the security of treatments. They also showed that the dose delivery processes in the cancer center were in control for prostate and head-and-neck treatments. In parallel, long term process performance indices (P{sub p}, P{sub pk}, and P{sub pm}) have been analyzed. Their analysis helped defining which actions should be undertaken in order to improve the performance of the process. The prostate dose delivery process has been shown statistically capable (0.08% of the results is expected to be outside the clinical tolerances) contrary to the head-and-neck dose delivery process (5.76% of the results are expected to be outside the clinical tolerances).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Filling the gaps in meteorological continuous data measured at FLUXNET sites with ERA-Interim reanalysis

In this study, exchanges of carbon, water and energy between the land surface and the atmosphere are monitored by eddy covariance technique at the ecosystem level. Currently, the FLUXNET database contains more than 500 registered sites, and up to 250 of them share data (free fair-use data set). Many modelling groups use the FLUXNET data set for evaluating ecosystem models' performance, but this requires uninterrupted time series for the meteorological variables used as input. Because original in situ data often contain gaps, from very short (few hours) up to relatively long (some months) ones, we develop a new and robust method for filling the gaps in meteorological data measured at site level. Our approach has the benefit of making use of continuous data available globally (ERA-Interim) and a high temporal resolution spanning from 1989 to today. These data are, however, not measured at site level, and for this reason a method to downscale and correct the ERA-Interim data is needed. We apply this method to the level 4 data (L4) from the La Thuile collection, freely available after registration under a fair-use policy. The performance of the developed method varies across sites and is also function of the meteorological variable. On average over all sites, applying the bias correction method to the ERA-Interim data reduced the mismatch with the in situ data by 10 to 36 %, depending on the meteorological variable considered. In comparison to the internal variability of the in situ data, the root mean square error (RMSE) between the in situ data and the unbiased ERA-I (ERA-Interim) data remains relatively large (on average over all sites, from 27 to 76 % of the standard deviation of in situ data, depending on the meteorological variable considered). The performance of the method remains poor for the wind speed field, in particular regarding its capacity to conserve a standard deviation similar to the one measured at FLUXNET stations.

58 GEOSCIENCES↗

Long-Term Effects of Power Quality and Power Cycling on Thermoelectric Module Performance

Thermoelectric (TE) modules used in a heat pumping mode are increasingly being used for various applications involving heating and cooling. As their use becomes more prevalent and extends to lower cost applications using inexpensive commodity power supplies, it is important to characterize the long-term effects of power cycling and power quality on their performance. Two power supplies were evaluated with different levels of periodic and random deviations (PARD) from ideal DC power. This paper presents the results of an accelerated aging experimental study on intermittent power cycling of TE modules over the span of 5 actual months with each power supply. TE performance metrics that were monitored at specific time intervals are the AC resistance and figure of merit. The applied voltage, power consumption, TE hot and cold side temperatures and air temperatures were continuously measured. The experimental results indicate that the low-quality power supply quality had only a minor influence on properties and integrity of the TE modules, and is suitable for applications requiring intermittent use without a substantial reduction in performance.

Patel, Viral↗

Air-Flow Navigated Crystal Growth for TIPS Pentacene-Based Organic Thin-Film Transistors

6,13-bis(triisopropylsilylethynyl)pentacene (TIPS pentacene) is a promising active channel material of organic thin-film transistors (OTFTs) due to its solubility, stability, and high mobility. However, the growth of TIPS pentacene crystals is intrinsically anisotropic and thus leads to significant variation in the performance of OTFTs. In this paper, air flow is utilized to effectively reduce the TIPS pentacene crystal anisotropy and enhance performance consistency in OTFTs, and the resulted films are examined with optical microscopy, grazing-incidence X-ray diffraction, and thin-film transistor measurements. Under air-flow navigation (AFN), TIPS pentacene drop-cast from toluene solution has been observed to form thin films with improved crystal orientation and increased areal coverage on substrates, which subsequently lead to a four-fold increase of average hole mobility and one order of magnitude enhancement in performance consistency defined by the ratio of average mobility to the standard deviation of the field-effect mobilities.

36 MATERIALS SCIENCE↗

SU-E-T-163: Characterization of a Novel High Resolution 1D Silicon Monolithic Array for Small Field Commissioning and Quality Assurance

Purpose: To study the suitability of a novel 1D silicon monolithic array for dosimetry of small radiation fields and for QA of high dose gradient treatment modalities (IMRT and SBRT). Methods: A 1D array composed of 4 monolithic silicon modules of 64 mm length and 1 mm pixel pitch was developed by IBA Dosimetry. Measurements were carried out for 6MV and 15MV photons on two commercial different linacs (TrueBeam and Clinac iX, Varian Medical Systems, Palo Alto, CA) and for a CyberKnife G4 (Accuray Inc., Sunnyvale, CA). The 1D array was used to measure output factors (OF), profiles and off axis correction factors (OACF) for the Iris CyberKnife variable collimator (5–60 mm). In addition, dose profiles (at the isocenter plane) were measured for multiple IMRT and SBRT treatment plans and compared with those obtained using EDR2radiographic film (Carestream Health, Rochester NY), a commercial 2D diode array and with the dose distribution calculated using a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA). Results: Due to the small pixel pitch of the detector, IMRT and SBRT plan profiles deviate from film measurements by less than 2%. Similarly, the 1D array exhibits better performance than the 2D diode array due to the larger (7 mm) pitch of that device. Iris collimator OFs measured using the 1D silicon array are in good agreement with the commissioning values obtained using a commercial stereotactic diode as well as with published data. Maximum deviations are < 3% for the smallest field (5 and 7.5mm) and below 1% for all other dimensions. Conclusion: We have demonstrated good performances of the array for commissioning of small photon fields and in patient QA, compared with diodes and film typically used in these clinical applications. The technology compares favorably with existing commercial solutions The presenting author is founded by a Marie Curie Early Initial Training Network Fellowship of the European Communitys Seventh Framework Programme under contract number (PITN-GA-2011-289198-ARDENT). The research activity is hosted by IBA Dosimetry, Gmbh.

60 APPLIED LIFE SCIENCES↗

R and DE Robotic Sensor Intern Team: Advanced Sensor Suite Prototype

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel is an example of such an environment where a biannual inspection is currently performed. Presently inspections are performed by teleoperated robotic crawlers which provide low-res video feedback to the structural engineers. Advanced sensors: including Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. Possible sensors were a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The Hokuyo UTM-30LX-EW shown below provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. Along with the Lidar, a camera sensor, IMU sensor, pan-tit unit, and on board computer needed to be identified. The two panospheric cameras allow for full 360 deg. FOV. The IMU will give data on the state of the robot inside the tunnel. The computer is used to gather and process data on board and to control the pan-tilt system. Mounts were designed and 3D printed to build the prototype of the sensor suite. It was designed to have the Lidar on top With its full FOV free while having the camera below and as close to together as possible while still leaving much of their FOV visible. The design also managed the cables such that they were unlikely to be damaged if in tension and so that they did not intrude much on the cameras vision. The sensor tree developed for the H-Canyon tunnel inspection project produces a large quantity of camera and Lidar data. a postprocessing pipeline was created to facilitate the analysis of these data. The pipeline follows the following routine: 1) Registration - Salient local features in subsequent scans are identified and used to align the scans With one another. This allows production of a single cohesive map of the tunnel. 2) Sensor Fusion - RGB camera data is 'painted' onto the depth data created by the Lidar. 3) Segmentation - Individual surfaces from within the scene are segmented out separately for individual analysis. 4) Degradation Analysis - Automatic mapping of local deviation from the plane in position or surface normal is performed, as is detection of exposed rebar using Lidar return intensity. 2) Obstacle Detection - Lidar data is also used in real time to detect obstacles in the environment. This could give feedback to the operator to successfully drive in the tunnel. 6) Graphic User Interface - a custom GUI was created to facilitate customer use of the system. The system provides real-time feedback from both the cameras and Lidar. The Lidar point-cloud data is also used for obstacle detection. As the Lidar spins, various algorithms are run to analyze the current 'slice' and obstacles in the environment are determined and registered on a cost-map. A Graphical User Interface (GUI) was developed to allow the user to easily command the crawler to set the rotational speed of the Lidar, perform a scan, and register and save the 3D generated cloud after a scan is done. For the good of the crawler, a critical aspect of the GUI design is to allow the user to cancel a scan any time after it is commanded and before it is saved. The sensor trees depth accuracy was evaluated in comparison to a high end commercial FARO Terrestrial Laser Scanner (TLS) with specifications for millimeter accuracy at distances above 10 m. For the purposes of these tests, the depth measurements produced by the TLS were taken as ground truth. Example test wall panels were scanned with the TLS and postprocessed with its proprietary software, and subsequently scanned with the sensor tree system. The two scans were manually aligned and for each point in the output cloud from the sensor tree, the distance to the nearest ground truth point in the FARO cloud was determined. 98.7% of all produced points were within the specified target range of 6 mm, with an average deviation of 1.75 mm. The test walls used have an overall in-wall depth variation of around 40 mm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector

Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High vacuum cells for classical surface techniques

Novel glass cells were designed and built to be able to perform surface potential and surface tension measurements in a contained environment. The cells can withstand pressures of approximately 1x10{sup -6} Torr, providing a reasonable level of control in terms of the amounts of volatile contaminants during experimentation. The measurements can take several hours; thus the cells help maintain the integrity of the sample in the course of the experiment. To test for the feasibility of the cell design, calibration measurements were performed. For the surface potential cell, the modified TREK 6000B-7C probe exhibited performance comparable to its unmodified counterpart. The correlation measurements between applied potential on the test surface and the measured potential showed R-values very close to 1 as well as standard deviation values of less than 1. Results also demonstrate improved measurement values for experiments performed in vacuum. The surface tension cell, on the other hand, which was used to perform the pendant drop method, was tested on common liquids and showed percentage errors of 0.5% when compared to literature values. The fabricated cells redefine measurements using classical surface techniques, providing unique and novel methods of sample preparation, premeasurement preparation, and sample analysis at highly beneficial expenditure cost.

36 MATERIALS SCIENCE↗

Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Results: Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system’s ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. Conclusions: The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.

07 ISOTOPE AND RADIATION SOURCES↗

Measuring and monitoring KIPT Neutron Source Facility Reactivity

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on developing and constructing a neutron source facility at Kharkov, Ukraine. The facility consists of an accelerator-driven subcritical system. The accelerator has a 100 kW electron beam using 100 MeV electrons. The subcritical assembly has k eff less than 0.98. To ensure the safe operation of this neutron source facility, the reactivity of the subcritical core has to be accurately determined and continuously monitored. A technique which combines the area-ratio method and the flux-to-current ratio method is purposed to determine the reactivity of the KIPT subcritical assembly at various conditions. In particular, the area-ratio method can determine the absolute reactivity of the subcritical assembly in units of dollars by performing pulsed-neutron experiments. It provides reference reactivities for the flux-to-current ratio method to track and monitor the reactivity deviations from the reference state while the facility is at other operation modes. Monte Carlo simulations are performed to simulate both methods using the numerical model of the KIPT subcritical assembly. It is found that the reactivities obtained from both the area-ratio method and the flux-to-current ratio method are spatially dependent on the neutron detector locations and types. Numerical simulations also suggest optimal neutron detector locations to minimize the spatial effects in the flux-to-current ratio method. The spatial correction factors are calculated using Monte Carlo methods for both measuring methods at the selected neutron detector locations. Monte Carlo simulations are also performed to verify the accuracy of the flux-to-current ratio method in monitoring the reactivity swing during a fuel burnup cycle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quality Control Analysis in Real-time (QC-ART): A Tool for Real-time Quality Control Assessment of Mass Spectrometry-based Proteomics Data

Liquid chromatography-mass spectrometry (LC-MS)-based proteomics studies of large sample cohorts can easily require from months to years to complete. Acquiring consistent, high-quality data in such large-scale studies is challenging because of normal variations in instrumentation performance over time, as well as artifacts introduced by the samples themselves, such as those due to collection, storage and processing. Existing quality control methods for proteomics data primarily focus on post-hoc analysis to remove low-quality data that would degrade downstream statistics; they are not designed to evaluate the data in near real-time, which would allow for interventions as soon as deviations in data quality are detected. In addition to flagging analyses that demonstrate outlier behavior, evaluating how the data structure changes over time can aide in understanding typical instrument performance or identify issues such as a degradation in data quality due to the need for instrument cleaning and/or re-calibration. To address this gap for proteomics, we developed Quality Control Analysis in Real-Time (QC-ART), a tool for evaluating data as they are acquired in order to dynamically flag potential issues with instrument performance or sample quality. QC-ART has similar accuracy as standard post-hoc analysis methods with the additional benefit of real-time analysis. We demonstrate the utility and performance of QC-ART in identifying deviations in data quality due to both instrument and sample issues in near real-time for LC-MS-based plasma proteomics analyses of a sample subset of The Environmental Determinants of Diabetes in the Young cohort. We also present a case where QC-ART facilitated the identification of oxidative modifications, which are often underappreciated in proteomic experiments.

Stanfill, Bryan A.↗

NNSA ASC Exascale Environment Planning, Applications Working Group, Report February 2011

The scope of the Apps WG covers three areas of interest: Physics and Engineering Models (PEM), multi-physics Integrated Codes (IC), and Verification and Validation (V&V). Each places different demands on the exascale environment. The exascale challenge will be to provide environments that optimize all three. PEM serve as a test bed for both model development and 'best practices' for IC code development, as well as their use as standalone codes to improve scientific understanding. Rapidly achieving reasonable performance for a small team is the key to maintaining PEM innovation. Thus, the environment must provide the ability to develop portable code at a higher level of abstraction, which can then be tuned, as needed. PEM concentrate their computational footprint in one or a few kernels that must perform efficiently. Their comparative simplicity permits extreme optimization, so the environment must provide the ability to exercise significant control over the lower software and hardware levels. IC serve as the underlying software tools employed for most ASC problems of interest. Often coupling dozens of physics models into very large, very complex applications, ICs are usually the product of hundreds of staff-years of development, with lifetimes measured in decades. Thus, emphasis is placed on portability, maintainability and overall performance, with optimization done on the whole rather than on individual parts. The exascale environment must provide a high-level standardized programming model with effective tools and mechanisms for fault detection and remediation. Finally, V&V addresses the infrastructure and methods to facilitate the assessment of code and model suitability for applications, and uncertainty quantification (UQ) methods for assessment and quantification of margins of uncertainty (QMU). V&V employs both PEM and IC, with somewhat differing goals, i.e., parameter studies and error assessments to determine both the quality of the calculation and to estimate expected deviations of simulations from experiments. The exascale environment must provide a performance envelope suitable both for capacity calculations (high through-put) and full system capability runs (high performance). Analysis of the results place shared demand on both the I/O as well as the visualization subsystems.

97 MATHEMATICS AND COMPUTING↗

A computational fluid dynamics simulation framework for ventricular catheter design optimization

OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter’s small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter’s fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter’s design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter’s inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using the standard catheter hole configuration as a baseline. While the standard ventricular catheter design featuring uniform inlet hole diameters and hole spacing has a standard deviation of 14.27% for the inlet flow rates, the optimized design has a standard deviation of 0.30%. CONCLUSIONS This customizable framework, paired with high-performance computing, provides a rapid method of design testing to solve complex flow problems. While a relatively simplified ventricular catheter model was used to demonstrate the framework, the computational approach is applicable to any baseline catheter model, and it is easily adapted to optimize catheters for the unique needs of different patients as well as for other fluid-based medical devices.

Neurosciences & Neurology↗

Cone Beam Computed Tomography: The Challenges and Strategies in Its Application for Dose Accumulation

Online image guidance using cone beam computed tomography (CBCT) has greatly improved the geometric precision of radiotherapy. Changes in anatomy are common during a course of fractionated treatment, resulting in dose deviation from the planned distribution. There is increased interest in performing dose accumulation to compute the actual delivered dose and to adapt the treatment when necessary. This can be achieved by delineating the volume of interest and by generating “dose of the day” through dose computation on the CBCT. However, the image quality and the accuracy of the CT number of CBCT are deemed to be inferior to fan beam CT, which increases the uncertainty associated in this process. A review of literature was conducted to assess the reliability of and to examine strategies for overcoming the challenges in using CBCT for volume delineation and dose computation. The review demonstrates that the uncertainty varies across body sites, and different strategies have been recommended to generate comparable results to images from CT simulators. This facilitates a better understanding of the potential and the limitation of using CBCT for dose accumulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

K-shell radiation and bright spot characteristics of high-energy-density Fe-Cr-Ni plasmas influenced by X-pinch load geometry

K-shell radiation is diagnostically advantageous for the study of high-energy-density plasmas. Here, the current work investigates the influence of load geometry on K-shell x-rays in Z-pinch plasmas produced on the 1-MA Zebra generator. Stainless steel (Fe: 69%, Cr: 20%, Ni: 9%) X-pinch wire loads are fielded with an interwire angle of 31° (small-angle) or 62.5° (large-angle), respectively and studied using various x-ray diode, imaging, and spectroscopic diagnostics. The large-angle geometry produced large, individual x-ray-emitting bright spots (> 3 keV) at the wire cross-point averaging areas ≥ 1 mm 2 , with noteworthy soft x-ray (> 0.75 keV) bursts and radiation yields ≤ 14.6 kJ. The small-angle geometry produced multiple x-ray-emitting bright spots extending the pinch axis with smaller average sizes (≤ 0.5 mm 2 ), consistent with stronger current, increased radiation yield (≥ 15.5 kJ), and notable hard x-ray (> 9 keV) bursts, which peak with largest cumulative bright spot size. Spectroscopic analysis is performed with non-LTE collisional-radiative modeling, indicating a cold, nonthermal plasma region radiating from neutral to Ne-like ions, a hot, thermal region radiating from Fe and Cr He- and Li-like ions, and an intermediate region radiating Kα satellites from Li-like to O-like ions. Modeling of the nonthermal and satellite features imply a fractional hot electron abundance ~0.1% and ~0.5% for large- and small-angle geometries, respectively. Relative intensity analysis is performed on Heα and Kα lines, revealing intensity ratios that deviate from the original wire composition. Optical depth estimates allude to optically thick, thermal K-shell plasmas with densities consistent with non-LTE modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of the setup margins for cone beam computed tomography–guided cranial radiosurgery: A phantom study

The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square field and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigating growth to detonation in vapor-deposited hexanitrostilbene and pentaerythritol tetranitrate films using high-throughput methods

In this work, a high-throughput experimental setup was used to characterize initiation threshold and growth to detonation in the explosives hexanitrostilbene (HNS) and pentaerythritol tetranitrate (PETN). The experiment sequentially launched an array of laser-driven flyers to shock samples arranged in a 96-well microplate geometry, with photonic Doppler velocimetry diagnostics to characterize flyer velocity and particle velocity at the explosive–substrate interface. Vapor-deposited films of HNS and PETN were used to provide numerous samples with various thicknesses, enabling characterization of the evolution of growth to detonation. One-dimensional hydrocode simulations were performed with reactions disabled to illustrate where the experimental data deviate from the predicted inert response. Prompt initiation was observed in 144 μm thick HNS films at flyer velocities near 3000 m/s and in 125 μm thick PETN films at flyer velocities near 2400 m/s. This experimental setup enables rapid quantification of the growth of reactions in explosive materials that can reach detonation at sub-millimeter length scales. These data can subsequently be used for parameterizing reactive burn models in hydrocode simulations, as discussed in Paper II [D. E. Kittell, R. Knepper, and A. S. Tappan, J. Appl. Phys. 131, 154902 (2022)].

36 MATERIALS SCIENCE↗