Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Life Science Research Facility materials management requirements and concepts

The Advanced Programs Office at NASA Ames Research Center has defined hypothetical experiments for a 90-day mission on Space Station to allow analysis of the materials necessary to conduct the experiments and to assess the impact on waste processing of recyclable materials and storage requirements of samples to be returned to earth for analysis as well as of nonrecyclable materials. The materials include the specimens themselves, the food, water, and gases necessary to maintain them, the expendables necessary to conduct the experiments, and the metabolic products of the specimens. This study defines the volumes, flow rates, and states of these materials. Process concepts for materials handling will include a cage cleaner, trash compactor, biological stabilizer, and various recycling devices.

Johnson, Catherine C.↗

A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing

Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).

Laser↗

The NASA OSIRIS-REx Sample Catalog: Samples Returned from Investigators

OSIRIS-REx is a sample return mission that collected carbon-rich material from B-type asteroid Bennu. After landing on September 24th, 2023, the science canister was transported to NASA Johnson Space Center (JSC) in Houston, Texas where it was opened and samples were processed by the curation team in pristine sample nitrogen gloveboxes. As the sample analysis phase of the OSIRIS-REx mission concludes, the Sample Analysis Team (SAT) has returned the majority of mission samples to NASA JSC curation and will return the remaining samples on a defined timetable. The curation team processed and documented as many of these samples as possible to include in the spring 2026 catalog update and are steadily working to process hundreds of more samples to include in the fall 2026 catalog update.

OSIRIS-REx↗

Networks for image acquisition, processing and display

The human visual system comprises layers of networks which sample, process, and code images. Understanding these networks is a valuable means of understanding human vision and of designing autonomous vision systems based on network processing. Ames Research Center has an ongoing program to develop computational models of such networks. The models predict human performance in detection of targets and in discrimination of displayed information. In addition, the models are artificial vision systems sharing properties with biological vision that has been tuned by evolution for high performance. Properties include variable density sampling, noise immunity, multi-resolution coding, and fault-tolerance. The research stresses analysis of noise in visual networks, including sampling, photon, and processing unit noises. Specific accomplishments include: models of sampling array growth with variable density and irregularity comparable to that of the retinal cone mosaic; noise models of networks with signal-dependent and independent noise; models of network connection development for preserving spatial registration and interpolation; multi-resolution encoding models based on hexagonal arrays (HOP transform); and mathematical procedures for simplifying analysis of large networks.

Ahumada, Albert J., Jr.↗

Stand Up of Uranium Capability for Swipe Analysis

The INL has established the capability to process and analyze swipe samples to determine if the amount of U and Pu present on equipment and facilities are at the level typical for natural background, to quantify their isotopic composition and to determine if any off-normal isotopic ratio present in the sample is statistically relevant. A previous report detailed this capability for Pu and preliminarily for U; this report describes the measurements and analysis that were performed to demonstrate the INL capability for U.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of digestion, chemical separation, and deposition on Po-210 quantitative analysis

Polonium-210 is a radioactive isotope often used to study sedimentation processes, food chains, aerosol behavior, and atmospheric circulations related to environmental sciences. Materials for the analysis of Po-210 range from tobacco leaves or cotton fibers, to soils and sediments. The purpose of this work was to determine polonium losses from a variety of sample types (soil, cotton fiber, and air filter) due to digestion technique, chemical separation, and deposition method for alpha energy analysis. Results demonstrated that yields from a perchloric acid wet-ash were similar to that from a microwave digestion. Both were greater than the dry-ash procedure. The polonium yield from the perchloric acid wet ash was 87 ± 5%, the microwave digestion had a yield of 100 ± 7%, and the dry ash had a yield of 38 ± 5%. The chemical separation of polonium by an anion exchange resin was used only on the soil samples due to the complex nature of this sample. The yield of Po-209 tracer after chemical separation and deposition for alpha analysis was 83 ± 7% for the soil samples. Spontaneous deposition yields for the cotton and air filters were 87 ± 4% and 92 ± 6%, respectively. Based on the overall process yields for each sample type the amount of Po-210 was quantified using alpha energy analysis. The soil contained 0.18 ± 0.08 Bq/g, the cotton swipe contained 0.7 mBq/g, and the air filter contained 0.04 ± 0.02 mBq/g. High and robust yields of polonium are possible using a suitable digestion, separation, and deposition method.

Seiner, Brienne N.↗

High-Throughput Microfluidics Platform for Intracellular Delivery and Sampling of Biomolecules from Live Cells

Nondestructive cell membrane permeabilization systems enable the intracellular delivery of exogenous biomolecules for cell engineering tasks as well as the temporal sampling of cytosolic contents from live cells for the analysis of dynamic processes. Here, in this paper, we report a microwell array format live-cell analysis device (LCAD) that can perform localized-electroporation induced membrane permeabilization, for cellular delivery or sampling, and directly interfaces with surface-based biosensors for analyzing the extracted contents. We demonstrate the capabilities of the LCAD via an automated high-throughput workflow for multimodal analysis of live-cell dynamics, consisting of quantitative measurements of enzyme activity using self-assembled monolayers for MALDI mass spectrometry (SAMDI) and deep-learning enhanced imaging and analysis. By combining a fabrication protocol that enables robust assembly and operation of multilayer devices with embedded gold electrodes and an automated imaging workflow, we successfully deliver functional molecules (plasmid and siRNA) into live cells at multiple time-points and track their effect on gene expression and cell morphology temporally. Furthermore, we report sampling performance enhancements, achieving saturation levels of protein tyrosine phosphatase activity measured from as few as 60 cells, and demonstrate control over the amount of sampled contents by optimization of electroporation parameters using a lumped model. Lastly, we investigate the implications of cell morphology on electroporation-induced sampling of fluorescent molecules using a deep-learning enhanced image analysis workflow.

59 BASIC BIOLOGICAL SCIENCES↗

Scaling Up Data-Parallel Analytics Platforms: Linear Algebraic Operation Cases

Linear algebraic operations such as matrix manipulations form the kernel of many machine learning and other crucial algorithms. Scaling up as well as scaling out such algorithms are key to supporting large scale data analysis that require efficient processing over millions of data samples. To this end, we present, ARION, a hardware acceleration based approach for scaling-up individual tasks of Spark, a popular data-parallel analytics platform. We support both linear algebraic operations of between two dense matrices, and between sparse and dense matrices in distributed environments. ARION provides a flexible control of acceleration according to matrix density, along with efficient scheduling based on runtime resource utilization. We demonstrate the benefit of our approach for general matrix multiplication operations over large matrices with up to four billion elements by using Gramian matrix computation that is commonly used in machine learning. Experiments show that our approach achieves more than 2× and 1.5× end-to-end performance speedups for dense and sparse matrices, respectively, and up to 57.04× faster computation compared to MLlib, a state of the art Spark-based implementation. This work is sponsored in part by the NSF under the grants: CNS-1565314, CNS-1405697, and CNS-1615411. The manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). This research used resources of the Oak Ridge Leadership Computing Facility at the Oak Ridge National Laboratory, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725.

Xu, Luna↗

Total Mercury Analysis Comparison: Deployment of Analytical Method for the Savannah River Site Liquid Waste System

A direct mercury analyzer (DMA; EPA 7473) and Cold Vapor Atomic Absorption Spectroscopy (CVAAS; EPA 245.2) have been used to analyze samples high in methylmercury and other forms of mercury with oxidation states of Hg o (elemental), Hg 1+ (mercurous), and/or Hg 2+ (mercuric) to determine analytical data equivalency for total mercury. The DMA instrument has been determined to be the preferred method based on both simulated and radioactive sample testing due to analytical results and ease of use in a radiological hood. SRNL made a number of modifications to the DMA instrument and analysis method to limit the amount of time personnel are required to work in a radiological environment. Equivalency is based on comparative statistical evaluation of the results from: spike solutions/simulants, Tank 50 samples, Mixed Analyte Performance Evaluation Program (MAPEP) samples, and Modular Caustic-Side Solvent Extraction Unit (MCU) solvent samples. SRNL performed a cross-comparison of results using CVAAS, DMA, and Inductively Coupled Plasma Mass Spectrometer (ICP-MS), as well as independent analysis from an offsite laboratory (using cold vapor sample processing with atomic fluorescence detection, EPA 1631). All data were within the combined uncertainty (2σ ± 20%) of the CVAAS and DMA methods

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Total, Organic, and Inorganic Carbon in Biological Cultures and Liquid Fraction Process Samples

This procedure describes a method for analyzing dissolved and suspended total carbon, in organic and inorganic form in biological cultures, in the presence or absence of cells, and liquid fraction conversion process samples. This method calculates total organic carbon by subtraction of inorganic carbon, derived from sample acidification, from total dissolved carbon by combustion at 680°C with detection of derived gaseous CO 2 by a non-dispersive infrared (NDIR) sensor. The inclusion of details on a process step of heat treating biologically active samples before analysis can potentially halt biological activity, preserving carbon stores and allowing for accurate quantification of the carbon content at the time of sample collection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human Lung Fibroblast Response to HCoV-229E Infection, Top-down Proteomics of Histones (ACS-TZ-DP7)

The purpose of this experiment was to evaluate the human host cellular response to wild type human coronavirus strain 229E (HCoV-229E) infection, specifically how histones are modified following infection. Sample data was obtained from mock-infected and HCoV-229E-infected immortalized human lung fibroblasts (MRC-5) (MOI 3). Whole cell lysates were collected at 24 hours post infection and histones from all samples were enriched and were processed for proteoform identification analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Laser-zone growth in a Ribbon-To-Ribbon, RTR, process silicon sheet growth development for the large area silicon sheet task of the low cost silicon solar array project

A ribbon-to-ribbon process was used for routine growth of samples for analysis and fabrication into solar cells. One lot of solar cells was completely evaluated: ribbon solar cell efficiencies averaged 9.23% with a highest efficiency of 11.7%. Spherical reflectors have demonstrated significant improvements in laser silicon coupling efficiencies. Material analyses were performed including silicon photovoltage and open circuit photovoltage diffusion length measurements, crystal morphology studies, modulus of rupture measurements, and annealing/gettering studies. An initial economic analysis was performed indicating that ribbon-to-ribbon add-on costs of $.10/watt might be expected in the early 1980's.

Gurtler, R. W.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

Laser-driven hydrothermal processing: a new, efficient technique to effect separation of silica from other oxides for analysis

We report on what appeared to be an unstudied regime of laser-matter interactions, when modest-intensity, modest-fluence laser pulses struck weakly-absorbing, silica-rich material that was submerged in water: material was efficiently removed from the surface and colorless particles were left behind, decorating crater's surface. One explanation for this color loss was a transient dissolution of the material, due to the pressure and temperature pulse caused by the laser absorption and thermally-driven expansion of the material. Yet, other explanations were possible. Here, we have studied this process with laser intensity and fluence so low that no crater was formed, when a sample of natural quartzite rock was submerged in deionized water and illuminated with 40 MW cm –2 , 527 nm laser pulses. After one hundred laser pulses, the treated surface of the originally colored quartzite was colorless. We cut the quartzite in cross section and examined the colorless material on the surface with x-ray fluorescence. We report that the transition element Fe was found to be significantly depleted in this colorless layer, while Si was not. This bolsters the hypothesis that the laser exposure led to a transient hydrothermal dissolution of the material, followed by a recrystallization process of the SiO 2 that preferentially released iron oxides into the submerging water.

36 MATERIALS SCIENCE↗

The Integration of Plant Sample Analysis, Laboratory Studies, and Thermodynamic Modeling to Predict Slag-Matte Equilibria in Nickel Sulfide Converting

The Kalgoorlie Nickel Smelter (KNS) produces low Fe, low Cu nickel matte in its Peirce–Smith converter operations. To inform process development in the plant, new fundamental data are required on the effect of CaO in slag on the distribution of arsenic between slag and matte. A combination of plant sample analysis, high-temperature laboratory experiments, and thermodynamic modeling was carried out to identify process conditions in the converter and to investigate the effect of slag composition on the chemical behavior of the system. The high-temperature experiments involved re-equilibration of industrial matte-slag-lime samples at 1498 K (1225 °C) and P(SO{sub 2}) = 0.12 atm on a magnetite/quartz substrate, rapid quenching in water, and direct measurement of phase compositions using electron probe X-ray microanalysis (EPMA) and laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS). A private thermodynamic database for the Ca-Cu-Fe-Mg-Ni-O-S-Si-(As) system was used together with the FactSage software package to assist in the analysis. Thermodynamic predictions combined with plant sample characterization and the present experimental data provide a quantitative basis for the analysis of the effect of CaO fluxing on the slag-matte thermochemistry during nickel sulfide converting, in particular on the spinel liquidus and the distribution of elements between slag and matte as a function of CaO addition.

36 MATERIALS SCIENCE↗

Binning is Sinning: Redemption for Hubble Diagram Using Photometrically Classified Type Ia Supernovae

Bayesian Estimation Applied to Multiple Species (BEAMS) is implemented in the BEAMS with Bias Corrections (BBC) framework to produce a redshift-binned Hubble diagram (HD) for Type Ia supernovae (SNe Ia). BBC corrects for selection effects and non–SN Ia contamination, and systematic uncertainties are described by a covariance matrix with dimension matching the number of BBC redshift bins. For spectroscopically confirmed SN Ia samples, a recent "Binning is Sinning" article showed that an unbinned HD and covariance matrix reduces the systematic uncertainty by a factor of ~1.5 compared to the binned approach. Here we extend their analysis to obtain an unbinned HD for a photometrically identified sample processed with BBC. To test this new method, we simulate and analyze 50 samples corresponding to the Dark Energy Survey (DES) with a low-redshift anchor; the simulation includes SNe Ia, and contaminants from core-collapse SNe and peculiar SNe Ia. The analysis includes systematic uncertainties for calibration and measures the dark energy equation of state parameter (w). Compared to a redshift-binned HD, the unbinned HD with nearly 2000 events results in a smaller systematic uncertainty, in qualitative agreement with BHS21, and averaging results among the 50 samples we find no evidence for a w-bias. To reduce computation time for fitting an unbinned HD with large samples, we propose an HD-rebinning method that defines the HD in bins of redshift, color, and stretch; the rebinned HD results in similar uncertainty as the unbinned case, and shows no evidence for a w-bias.

79 ASTRONOMY AND ASTROPHYSICS↗