Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A novel data gaps filling method for solar PV output forecasting

This study proposes a modified gaps filling method, expanding the column mean imputation method and evaluated using randomly generated missing values comprising 5%, 10%, 15%, and 20% of the original data on power output. The XGBoost algorithm was implemented as a forecasting model using the original and processed datasets and two sources of solar radiation data, namely, Shortwave Radiation (SWR) from Advanced Himawari Imager 8 (AHI-8) and Surface Solar Radiation Downward (SSRD) from ERA5 global reanalysis data. Further, the accuracy of the two sets of forecasted power output was evaluated using Root Mean Square Error (RMSE) and Mean Absolute Error (MAE). Results show that by applying the proposed gap filling method and using SWR in forecasting solar photovoltaic (PV) output, the improvement in the RMSE and MAE values range from 12.52% to 24.30% and from 21.10% to 31.31%, respectively. Meanwhile, using SSRD, the improvement in the RMSE values range from 14.01% to 28.54% and MAE values from 22.39% to 35.53%. To further evaluate the accuracy of the proposed gap-filling method, the proposed method could be validated using different datasets and other forecasting methods. Future studies could also consider applying the said method to datasets with data gaps higher than 20%.

Energy & Fuels↗

Toward “super-scintillation” with nanomaterials and nanophotonics

Abstract Following the discovery of X-rays, scintillators are commonly used as high-energy radiation sensors in diagnostic medical imaging, high-energy physics, astrophysics, environmental radiation monitoring, and security inspections. Conventional scintillators face intrinsic limitations including a low extraction efficiency of scintillated light and a low emission rate, leading to efficiencies that are less than 10 % for commercial scintillators. Overcoming these limitations will require new materials including scintillating nanomaterials (“nanoscintillators”), as well as new photonic approaches that increase the efficiency of the scintillation process, increase the emission rate of materials, and control the directivity of the scintillated light. In this perspective, we describe emerging nanoscintillating materials and three nanophotonic platforms: (i) plasmonic nanoresonators, (ii) photonic crystals, and (iii) high-Q metasurfaces that could enable high performance scintillators. We further discuss how a combination of nanoscintillators and photonic structures can yield a “super scintillator” enabling ultimate spatio-temporal resolution while enabling a significant boost in the extracted scintillation emission.

Carr Delgado, Hamish↗

BLOOD-BASED MULTI-SCALE MODEL FOR CANCER RISK FROM GCR IN GENETICALLY DIVERSE POPULATIONS

OBJECTIVES AND METHODS This project addresses the challenge of understanding and predicting individual radiation sensitivity by integrating genetics, demographics and biomarker characteristics across species (mice and humans). We hypothesize that ex vivo DNA repair response to GCR components is a central determinant of cancer risk from space radiation and can serve as a biomarker of radiation risk in combination with genetics. Automated image quantification of 53BP1+ radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET in non-immortalized primary skin fibroblasts derived from 76 mice across 15 strains (5 inbred reference strains and 10 collaborative-cross strains) exposed to X rays (0.1, 1 and 4 Gy), 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100μm2), as well as in peripheral blood mononuclear cells (PBMCs) from 768 healthy donors (matched ethnicity, 50/50 male/female, 18-70 years old) exposed to gamma rays (0.1 and 1 Gy), 350 MeV/n 28Si, 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100μm2). QUANTIFICATION OF 53BP1+ FOCI IN VITRO AND ASSOCIATIONS TO IN VIVO RADIATION SUSCEPTIBILITY IN 15 MOUSE STRAINS We reported in vitro repair kinetic and repairable fractions of RIF for the 15 mouse strains and introduced a mathematical model for RIF as a function of time, dose and LET. We noted that the metabolic activity of cells modulates the RIF response, and we introduced the open access tool terRIFic (Tool for Enhanced Results of RIF In Cells, https://radbiolab.shinyapps.io/terrific/) to correct for such bias using confluence level. Notably, at 4h post-irradiation, RIF/Gy decreased with dose or LET: as the dose or LET increases, so does the proximity of DNA double-strand-breaks (DSB) and our data suggest that proximal DSBs are brought together inside isolated RIF for repair. The RIF/Gy trend was inverted at 24h, suggesting RIF with high DSB content are more difficult to repair. We showed that in vitro metrics correlate with in vivo measurements in the same 15 mouse strains, such as survival levels of immune cells or spontaneous cancer incidence, suggesting a relationship between the efficiency of DSB repair and cancer risk or radiation toxicity. In addition to the efficiency of repair and persistent RIF, the amount of spontaneous foci before irradiation was also found to be strain dependent. Finally, we performed genome-wide association study in the same 15 mouse strains using all RIF phenotypes measured in vitro, identifying genes of interest and validating RIF as an ideal biomarker for individual radiation sensitivity. BASELINE 53BP1+ FOCI PREDICTS INDIVIDUAL HUMAN RESPONSE TO GCR COMPONENTS Based on the analysis of radiation responses of 576 donor PBMCs (using quantification of 53BP1+ foci, oxidative stress and cell death), we observed a wide variability of subject- and LET-dependent radiation responses, with radiation-induced DNA repair foci increasing with LET, though oxidative stress being notably reduced by high-LET irradiation, potentially due to a switch between hydrogen peroxide and oxygen radical-based mechanisms. We identified a relationship between few spontaneous DNA foci at baseline and increased DNA repair after irradiation, accompanied by an alteration in immunoregulatory cytokine secretion, which might be adapted as biomarkers to predict ionizing radiation sensitivity. Among demographic variables, only latent cytomegalovirus infection and age were predictive of high baseline foci formation. Finally, we have performed low-throughput whole genome sequencing of all samples and are currently in the process of identifying the genes and pathways associated with low and high-LET ionizing radiation sensitivity in humans.

53BP1↗

An Open-Science Approach to Address Individual Response to Simulated GCR In Genetically Diverse Populations of Mice and Humans

This project addresses the challenge of understanding and predicting individual radiation sensitivity by integrating genetics, demographics and biomarker characteristics across species (mice and humans). We hypothesize that ex vivo DNA repair response to GCR components is a central determinant of cancer risk from space radiation and can serve as a biomarker of radiation risk in combination with genetics. Automated image quantification of 53BP1+ radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET in non-immortalized primary skin fibroblasts derived from 76 mice across 15 strains (5 inbred reference strains and 10 collaborative-cross strains) exposed to X rays (0.1, 1 and 4 Gy), 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100sq. μm), as well as in peripheral blood mononuclear cells (PBMCs) from 768 healthy donors (matched ethnicity, 50/50 male/female, 18-70 years old) exposed to gamma rays (0.1 and 1 Gy), 350 MeV/n 28Si, 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100sq. μm). A genome-wide association study (GWAS) was performed on the mouse strains between DNA damage responses to space radiation and single nucleotide polymorphisms (SNPs). We found SNPs, which were significantly associated to the RIF phenotype, mapped to genes and pathways that are functionally linked to health hazards for deep space exploration (e.g. carcinogenesis, nervous system damage and immune dysfunction). Some of these SNPs were located within protein coding regions, potentially interfering with protein functions and providing promising genetic targets for countermeasures. We also found correlations between both spontaneous and radiation-induced DNA damage and SNPs mapped to pathways associated with cellular metabolism. GWAS is undergoing for the human data. All data have been made available via the NASA Space Biology Open-Science database (genelab.nasa.gov) and we will discuss how various genomic and transcriptomic datasets can be accessed for modeling and integrated using machine learning methods for discovering new radiation biology.

Sylvain V Costes↗

Measurement Via Optical Near-Nulling and Subaperture Stitching

A subaperture stitching interferometer system provides near-nulling of a subaperture wavefront reflected from an object of interest over a portion of a surface of the object. A variable optical element located in the radiation path adjustably provides near-nulling to facilitate stitching of subaperture interferograms, creating an interferogram representative of the entire surface of interest. This enables testing of aspheric surfaces without null optics customized for each surface prescription. The surface shapes of objects such as lenses and other precision components are often measured with interferometry. However, interferometers have a limited capture range, and thus the test wavefront cannot be too different from the reference or the interference cannot be analyzed. Furthermore, the performance of the interferometer is usually best when the test and reference wavefronts are nearly identical (referred to as a null condition). Thus, it is necessary when performing such measurements to correct for known variations in shape to ensure that unintended variations are within the capture range of the interferometer and accurately measured. This invention is a system for nearnulling within a subaperture stitching interferometer, although in principle, the concept can be employed by wavefront measuring gauges other than interferometers. The system employs a light source for providing coherent radiation of a subaperture extent. An object of interest is placed to modify the radiation (e.g., to reflect or pass the radiation), and a variable optical element is located to interact with, and nearly null, the affected radiation. A detector or imaging device is situated to obtain interference patterns in the modified radiation. Multiple subaperture interferograms are taken and are stitched, or joined, to provide an interferogram representative of the entire surface of the object of interest. The primary aspect of the invention is the use of adjustable corrective optics in the context of subaperture stitching near-nulling interferometry, wherein a complex surface is analyzed via multiple, separate, overlapping interferograms. For complex surfaces, the problem of managing the identification and placement of corrective optics becomes even more pronounced, to the extent that in most cases the null corrector optics are specific to the particular asphere prescription and no others (i.e. another asphere requires completely different null correction optics). In principle, the near-nulling technique does not require subaperture stitching at all. Building a near-null system that is practically useful relies on two key features: simplicity and universality. If the system is too complex, it will be difficult to calibrate and model its manufacturing errors, rendering it useless as a precision metrology tool and/or prohibitively expensive. If the system is not applicable to a wide range of test parts, then it does not provide significant value over conventional null-correction technology. Subaperture stitching enables simpler and more universal near-null systems to be effective, because a fraction of a surface is necessarily less complex than the whole surface (excepting the extreme case of a fractal surface description). The technique of near-nulling can significantly enhance aspheric subaperture stitching capability by allowing the interferometer to capture a wider range of aspheres. More over, subaperture stitching is essential to a truly effective near-nulling system, since looking at a fraction of the surface keeps the wavefront complexity within the capability of a relatively simple nearnull apparatus. Furthermore, by reducing the subaperture size, the complexity of the measured wavefront can be reduced until it is within the capability of the near-null design.

Forbes, Greg↗

Image analysis used to count and measure etched tracks from ionizing radiation

We have developed techniques to use digitized scanning electron micrographs and computer image analysis programs to measure track densities in lunar soil grains and plastic dosimeters. Tracks in lunar samples are formed by highly ionizing solar energetic particles and cosmic rays during near surface exposure on the Moon. The track densities are related to the exposure conditions (depth and time). Distributions of the number of grains as a function of their track densities can reveal the modality of soil maturation. We worked on two samples identified for a consortium study of lunar weathering effects, 61221 and 67701. They were prepared by the lunar curator's staff as polished grain mounts that were etched in boiling 1 N NaOH for 6 h to reveal tracks. We determined that backscattered electron images taken at 10 percent contrast and approximately 50 percent brightness produced suitable high contrast images for analysis. We used the NIH Image program to cut out areas that were unsuitable for measurement such as edges, cracks, etc. We ascertained a gray-scale threshold of 25 to separate tracks from background. We used the computer to count everything that was two pixels or greater in size and to measure the area to obtain track densities. We found an excellent correlation with manual measurements for track densities below 1 x 10(exp 8) cm(exp -2). For track densities between 1 x 10(exp 8) cm(exp -2) to 1 x 10(exp 9) cm(exp -2) we found that a regression formula using the percentage area covered by tracks gave good agreement with manual measurements. We determined the track density distributions for 61221 and 67701. Sample 61221 is an immature sample, but not pristine. Sample 67701 is a submature sample that is very close to being fully mature. Because only 10 percent of the grains have track densities less than 10(exp 9) cm(exp -2), it is difficulty to determine whether the sample matured in situ or is a mixture of a mature and a submature soil. Although our analysis of plastic dosimeters is at an early stage of development, results are encouraging. The dosimeter was etched in 6.25 N NaOH at 70 deg C for 16 h. We took 200x secondary electron images of the sample and used the NIH Image software to count and measure major and minor diameters of the etched tracks. We calculated the relative track etch rate from a formula that relates it to the major and minor diameters. We made a histogram of the number of tracks versus their relative etch rate. The relative track etching rate is proportional to the linear energy transfer of the particle. With appropriate calibration experiments, the histogram could be used to calculate the radiation dose.

Blanford, George E.↗

Hubble Space Telescope images of the Seyfert galaxies NGC 5929 and MCG 8-11-11

We present the initial results of a program to obtain high resolution images of Seyfert galaxies with the Planetary Camera aboard the Hubble Space Telescope (HST). In this paper we discuss the images of the type 2 Seyfert NGC 5929 and the type 1.5 Seyfert MCG 8-11-11 (= UGC 3374). The images were obtained in the emission lines of (O III) lambda lambda 4959 and 5007 A and H alpha + (N II) lambda lambda 6548 and 6583 A and their adjacent continua. The high-excitation gas in the narrow line region (NLR) of NGC 5929 is resolved into individual clouds in the central 1 sec .5. Although the (O III) emission is clearly not spherically symmetric with respect to the nucleus, it does not define a distinct 'bicone' morphology, as observed by the HST in a few other Seyfert galaxies. We find no direct evidence for the reddening and/or obscuration effects characteristic of a dusty torus, which, in the context of 'unified models', is expected to obscure the active galactic nucleus (AGN) in type 2 Seyfert galaxies. The correspondence between the emission line gas and the radio morphology suggests that the structure of the NLR in NGC 5929 is governed by matter ejected from the AGN. A comparison of the recombination rate of hydrogen in the brightest emission line cloud with an upper limit on the ionizing luminosity emitted toward Earth provides no evidence that the central ionizing source radiates anisotropically. The images of MCG 8-11-11 show only an unresolved nuclear source. No emission line gas associated with the extended radio source is detected. We estimate upper limits on the intensity of extended line emission in this galaxy and examine their significance.

Bower, Gary A.↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud Remote Sensing with EPIC/DSCOVR Observations: A Sensitivity Study with Radiative Transfer Simulations

The Earth Polychromatic Imaging Camera (EPIC) onboard the Deep Space Climate Observatory (DSCOVR) views nearly the whole sunlit face of the Earth with 10 spectral bands ranging from the UV to the near-infrared, including two oxygen absorbing bands centered at 764 nm (A-band) and 687.75 nm (B-band). Clouds are among the primary remote sensing targets using EPIC images because of their important impacts on the Earth’s radiation budget. In order to facilitate the EPIC cloud data product development, we have built a radiative transfer simulator featuring flexible cloud microphysical parameters, gas absorptions, and the instrument line shape functions for each EPIC band. The radiative transfer simulator is used to explore the sensitivity of EPIC observations on liquid-phase cloud microphysical parameters, including optical depth, geometric thickness, and cloud top height. We found that the ratios of the reflectances in the oxygen A and B bands to their respective continuum measurements can be used to increase the confidence level of cloud masking over scenes with sun-glint. In addition, the 388 nm band can be used to differentiate low and high clouds with the uncertainty of roughly 2–3 km. Combining this information with the oxygen absorption bands, the cloud geometric thickness can be obtained with the rough uncertainty of 3–4 km.

atmospheric and ocean optics↗

Increased AGE Cross-Linking Reduces the Mechanical Properties of Osteons

Abstract The osteon is the primary structural component of bone, contributing significantly to its unique toughness and strength. Despite extensive research on osteonal structure, the properties of osteons have not been fully investigated, particularly within the context of bone fragility diseases like type 2 diabetes mellitus (T2DM). This study aims to isolate osteons from bovine bone, simulate the effects of increased advanced glycation end-products (AGEs) in T2DM through ribosylation, and evaluate the mechanical properties of isolated osteons. Osteons extracted from the posterior section of bovine femur mid-diaphysis were processed to achieve a sub-millimeter scale for microscale imaging. Subsequently, synchrotron radiation micro-computed tomography was employed to precisely localize and isolate the osteon internally. While comparable elastic properties were observed between control and ribosylated osteons, the presence of AGEs led to decreased strain to failure. Young’s modulus was quantified (9.9 ± 4.9 GPa and 8.7 ± 3 GPa, respectively), aligning closely with existing literature. This study presents a novel method for the extraction and isolation of osteons from bone and shows the detrimental effect of AGEs at the osteonal level.

Materials Science↗

Charge collection efficiency of diamond and silicon sensors irradiated with alpha particles

To evaluate the viability of using semiconductors as sensor materials in a detector for the Associated Particle Imaging technique, the radiation hardness of silicon and diamond diodes to alpha particles has been assessed. Here, the detector lifetimes for both silicon and diamond sensors were measured under the prolonged exposure to alpha particles emitted by an 241 Am source. The silicon detector was exposed to alpha radiation for approximately two months, reaching an accumulated fluence of ~ 1.5 x 10 12 α cm –2 . Additionally, by using a high purity single-crystal diamond with coplanar electrodes operating with full charge collection, the diamond detector response was measured over approximately ten months reaching an accumulated fluence of over 6 x 10 12 α cm –2 cm.

47 OTHER INSTRUMENTATION↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

“Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation”

Radioisotopes are essential for the development and application of radiopharmaceuticals that target specific diseases, such as cancer, offering unique potential for precision medicine. The growing demand for theranostic radioisotopes underscores their critical role in personalized medicine, where they enhance diagnostic imaging, minimize patient radiation exposure, and improve targeted tissue uptake, particularly in receptor- and antigen-directed therapies. The theranostic pair terbium-155 (diagnostic) and terbium-161 (therapeutic) holds significant promise for advancing individualized, targeted, and dosimetry-driven radiotherapies. However, the United States currently lacks routine and reliable production of these isotopes. This project made significant progress toward addressing this supply issue by developing production and separation methods for terbium-155 and terbium-161 while also training the next generation of the nuclear and radiochemistry workforce. This grant also strengthened collaboration between scientists at the University of Washington, the University of Missouri and Brookhaven National Laboratory. The research effort focused on evaluating target preparation methods, optimizing irradiation parameters, and refining isolation processes. In addition, the project provided extensive hands-on training to graduate students and postdoctoral fellows, equipping them with expertise in radioisotope production technologies and fostering the growth of the nuclear science workforce.

07 ISOTOPE AND RADIATION SOURCES↗