Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Trigonometric Parallaxes of Two T Dwarfs With Keck and ShaneAO Astrometry

We present trigonometric parallax and proper motion measurements for two T-type brown dwarfs. We derive our measurements from infrared laser guide star adaptive optics observations spanning five years from the ShaneAO/SHARCS and NIRC2/medium-cam instruments on the Shane and Keck telescopes, respectively. To improve our astrometric precision, we measure and apply a distortion correction to our fields for both instruments. We also transform the Keck and ShaneAO astrometric reference frames onto the ICRS using five-parameter parallax and proper motion solutions for background reference stars from Gaia DR2. Fitting for parallax and proper motion, we measure parallaxes of 73.5 ± 9.2 mas and 70.1 ± 6.7 mas for WISEJ19010703+47181688 (WISE1901) and WISEJ21543294+59421370 (WISE2154), respectively. We utilize Monte Carlo methods to estimate the error in our sparse field methods, taking into account overfitting and differential atmospheric refraction. Comparing to previous measurements in the literature, all of our parallax and proper motion values fall within 2σ of the published measurements, and 4 of 6 measurements are within 1σ. These data are among the first parallax measurements of these T dwarfs and serve as precise measurements for calibrating stellar formation models. These two objects are the first results of an ongoing survey of T dwarfs with Keck/NIRC2 and the Shane Adaptive Optics system at Lick Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Chromatic effects on the PSF and shear measurement for the Roman Space Telescope High-Latitude Wide Area Survey

Weak gravitational lensing (WL) is a key cosmological probe that requires precise measurement of galaxy images to infer shape distortions, or shear, and constrain cosmology. Accurate estimation of the point spread function (PSF) is crucial for shear measurement, but the wavelength dependence of the PSF introduces chromatic biases that can systematically impact shear inference. We focus on biases arising from spectral energy distribution (SED) differences between stars, used for PSF modelling, and galaxies, used for shear measurement. We investigate these effects in Roman’s four design reference mission WL bands (Y106, J129, H158, F184) and wide filter (W146). Using Roman-like image simulations, we quantify the induced shear biases and compare them to requirements on those biases. Multiplicative biases over all galaxies hover around ~0.2 per cent in the WL bands and 2 per cent in the wide filter, exceeding the mission requirement of |m| < 0.032 per cent and relaxed requirement of |m| < 0.1 per cent⁠. In individual redshift bins, biases can reach 0.4–0.9 per cent for the WL bands and 3–6 per cent for the wide filter. Additive biases remain acceptable in the WL bands but exceed systematic limits in the wide filter. We develop and test PSF-level corrections, showing that a first-order correction reduces biases within survey requirements for the WL bands; however, higher-order terms are necessary for the wide filter. Our results highlight the necessity of chromatic corrections for precision WL with Roman and provide a framework for mitigating these biases. Finally, we compare analytical colour-based corrections to self-organizing maps and find that both methods effectively reduce biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of interstellar He parameters using five years of data from the IBEX: Beyond closed form approximations

Interstellar He represents a key sample of interstellar matter that, due to its high first ionization potential, survives the journey from beyond our solar system’s heliospheric boundaries to Earth. Ongoing analysis of interstellar neutral (ISN) He atoms by the Interstellar Boundary Explorer (IBEX) has resulted in a growing sophistication in our understanding of the local interstellar flow. A key feature of the IBEX observations near perihelion of the ISN trajectories is a narrow “tube” of approximately degenerate interstellar parameters. These degenerate solutions provide a tightly coupled relationship between the interstellar flow longitude and latitude, speed, and temperature. However, the IBEX analysis resulting in a specific solution for the inflow longitude, inflow speed, temperature, and inflow latitude was accompanied by a sizeable uncertainty along the parameter tube. Here, we use the three-step method to find the interstellar parameters: (1) the ISN He peak rate in ecliptic longitude uniquely determines a relation (as part of the tube in parameter space) between the longitude λ{sub ISN∞} and the speed V{sub ISN∞} of the He ISN flow at infinity; (2) the ISN He peak latitude (on the great circle swept out in each spin) is compared to simulations to derive unique values for λ{sub ISN∞} and V{sub ISN∞} along the parameter tube; and (3) the angular width of the He flow distributions as a function of latitude is used to derive the interstellar He temperature. For simulated peak latitudes, we use a relatively new analytical tool that traces He atoms from beyond the termination shock into the position of IBEX and incorporates the detailed response function of IBEX-Lo. By varying the interstellar parameters along the IBEX parameter tube, we find the specific parameters that minimize the chi-square difference between observations and simulations. The new computational tool for simulating neutral atoms through the integrated IBEX-Lo response function makes no assumptions or expansions with respect to the spin-axis pointing or frame of reference. Thus, we are able to move beyond closed-form approximations and utilize observations of interstellar He during the complete five year period from 2009 to 2013 when the primary component of interstellar He is most prominent. Chi-square minimization of simulations compared to observations results in a He ISN flow longitude of 75.°6 ± 1.°4, latitude of −5.°12 ± 0.°27, speed of 25.4 ± 1.1 km s{sup −1}, and temperature of 8000 ± 1300 K, where the uncertainties are related and apply along the IBEX parameter tube. This paper also provides documentation for a new release of ISN data and associated model runs.

79 ASTRONOMY AND ASTROPHYSICS↗

Signature analysis of high-throughput transcriptomics screening data for mechanistic inference and chemical grouping

Abstract High-throughput transcriptomics (HTTr) uses gene expression profiling to characterize the biological activity of chemicals in in vitro cell-based test systems. As an extension of a previous study testing 44 chemicals, HTTr was used to screen an additional 1,751 unique chemicals from the EPA’s ToxCast collection in MCF7 cells using 8 concentrations and an exposure duration of 6 h. We hypothesized that concentration-response modeling of signature scores could be used to identify putative molecular targets and cluster chemicals with similar bioactivity. Clustering and enrichment analyses were conducted based on signature catalog annotations and ToxPrint chemotypes to facilitate molecular target prediction and grouping of chemicals with similar bioactivity profiles. Enrichment analysis based on signature catalog annotation identified known mechanisms of action (MeOAs) associated with well-studied chemicals and generated putative MeOAs for other active chemicals. Chemicals with predicted MeOAs included those targeting estrogen receptor (ER), glucocorticoid receptor (GR), retinoic acid receptor (RAR), the NRF2/KEAP/ARE pathway, AP-1 activation, and others. Using reference chemicals for ER modulation, the study demonstrated that HTTr in MCF7 cells was able to stratify chemicals in terms of agonist potency, distinguish ER agonists from antagonists, and cluster chemicals with similar activities as predicted by the ToxCast ER Pathway model. Uniform manifold approximation and projection (UMAP) embedding of signature-level results identified novel ER modulators with no ToxCast ER Pathway model predictions. Finally, UMAP combined with ToxPrint chemotype enrichment was used to explore the biological activity of structurally related chemicals. The study demonstrates that HTTr can be used to inform chemical risk assessment by determining in vitro points of departure, predicting chemicals’ MeOA and grouping chemicals with similar bioactivity profiles.

Toxicology↗

Three-Stage Adjusted Regression Forecasting for Software Defect Prediction

In this paper, a three-stage adjusted regression forecasting model is proposed to forecast the local regression model [6]. This is a growth curve approximation model that predicts the parameters for a future linear model based on a sliding window of previous linear models. The three stages of the model are as follows: • Initial fit: train regression models on a sliding window of the date and record model coefficients. • Prediction: fit new regression models to the coefficient lists and predict the value of the next coefficient. • Error correction: correct coefficient prediction error using the residual of the last point of the coefficient list and moving average. The resulting model from the multi-stage process is a forecast of the local regression model that represents the future window of data and is referred to as the predicted line. Results suggest the three-stage model demonstrates better prediction capability compared to existing solutions.

Pritchard, Shadow↗

Initial Verification and Validation Assessment for VERA

The Virtual Environment for Reactor Applications (VERA) code suite is assessed in terms of capability and credibility against the Consortium for Advanced Simulation of Light Water Reactors (CASL) Verification and Validation Plan (presented herein) in the context of three selected challenge problems: CRUD-Induced Power Shift (CIPS), Departure from Nucleate Boiling (DNB), and Pellet-Clad Interaction (PCI). Capability refers to evidence of required functionality for capturing phenomena of interest while capability refers to the evidence that provides confidence in the calculated results. For this assessment, each challenge problem defines a set of phenomenological requirements against which the VERA software is assessed. This approach, in turn, enables the focused assessment of only those capabilities relevant to the challenge problem. The evaluation of VERA against the challenge problem requirements represents a capability assessment. The mechanism for assessment is the Sandia-developed Predictive Capability Maturity Model (PCMM) that, for this assessment, evaluates VERA on 8 major criteria: (1) Representation and Geometric Fidelity, (2) Physics and Material Model Fidelity, (3) Software Quality Assurance and Engineering, (4) Code Verification, (5) Solution Verification, (6) Separate Effects Model Validation, (7) Integral Effects Model Validation, and (8) Uncertainty Quantification. For each attribute, a maturity score from zero to three is assigned in the context of each challenge problem. The evaluation of these eight elements constitutes the credibility assessment for VERA.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

I. Final Report for DOE SBIR Phase I Project DE-SC0013795 Final Report for DOE SBIR Phase I Project DE-SC0013795 Microtron-based Compact, Portable Gamma-Ray Source

Microtron-based Compact, Portable Gamma-Ray Source. The objective of Phase I of this project was to produce a conceptual design of a prototype compact microtron electron accelerator, which could be designed, built, and demonstrated in Phase II of the project. The conceptual design study included an analysis of the parameters of the microtron and its components, and the expected performance of the prototype microtron as a source of x-rays and/or RF neutrons in the MeV energy range. The major components of the microtron are the magnet, the accelerating system, the power system, the vacuum system, the control system, the beam extraction system and the targets to produce x-rays (and/or neutrons). Our objectives for the design of the prototype were for it to be compact, cost-effective, capable of producing high intensity x-ray (an/or neutron) fluxes. In addition, the prototype was to be easily assembled and disassembled so that components could be easily replaced. The main parameters for the prototype are the following: the range of electron kinetic energies, the output power, the RF frequency band (X-band, C-band, or S-Band), the type of injection (Type I or Type II), the magnet type, i.e. permanent magnet, electromagnet, or a hybrid combination of permanent and electromagnet. The results of the Phase I study and analysis for a prototype microtron are the following: The electron energy range can be varied from below 6 MeV to 9 MeV, the optimal frequency range is S-Band (2-4 GHz) RF frequency, Type II injection (described below), and the magnet type is the hybrid version. The prototype version will be capable of producing gamma ray doses of ~1800 R/min-m and neutron fluxes of up to ~6 x 10 10 n/s with appropriate targets. The results of the Phase I study and analysis are provided below. The proposed Phase II plan was to demonstrate the prototype at low beam power. In the subsequent Phase III, high power tests would be performed, and the design of commercial versions of microtrons with various energies, sizes and types would be produced and marketed, including a more compact and more portable 6 MeV battery-powered model that more closely meets the requirements in the original FOA topic description. In the course of the Phase I study, we also identified another microtron version, one that was larger (not compact) and more powerful than that of the Phase II prototype, which could serve as an intense source of photo- neutrons, up to 4 x 10 12 n/s for use in nuclear medicine, short-lived isotope production, or other applications. In addition, it could produce gamma dose rates up to 130 kR/min-m with a heavy metal bremsstrahlung target. The results and specifications of this were submitted to IPAC16 (Reference [12]) the paper is included in Addendum B. Because this version was beyond the scope of the Phase I project, there is no additional description in the Final Report.

43 PARTICLE ACCELERATORS↗

Updated Verification and Validation Assessment for VERA

The Virtual Environment for Reactor Applications (VERA) code suite is assessed in terms of capability and credibility against the Consortium for Advanced Simulation of Light Water Reactors (CASL) Verification and Validation Plan (presented herein) in the context of three selected challenge problems: CRUD-Induced Power Shift (CIPS), Departure from Nucleate Boiling (DNB), and Pellet-Clad Interaction (PCI). Capability refers to evidence of required functionality for capturing phenomena of interest while credibility refers to the evidence that provides confidence in the calculated results. For this assessment, each challenge problem defines a set of phenomenological requirements against which the VERA software is assessed. This approach, in turn, enables the focused assessment of only those capabilities relevant to the challenge problem. The evaluation of VERA against the challenge problem requirements represents a capability assessment. The mechanism for assessment is the Sandia-developed Predictive Capability Maturity Model (PCMM) that, for this assessment, evaluates VERA on 8 major criteria: (1) Representation and Geometric Fidelity, (2) Physics and Material Model Fidelity, (3) Software Quality Assurance and Engineering, (4) Code Verification, (5) Solution Verification, (6) Separate Effects Model Validation, (7) Integral Effects Model Validation, and (8) Uncertainty Quantification. For each attribute, a maturity score from zero to three is assigned in the context of each challenge problem. The evaluation of these eight elements constitutes the credibility assessment for VERA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Updated Verification and Validation Assessment for VERA

The Virtual Environment for Reactor Applications (VERA) code suite is assessed in terms of capability and credibility against the Consortium for Advanced Simulation of Light Water Reactors (CASL) Verification and Validation Plan (presented herein) in the context of three selected challenge problems: CRUD-Induced Power Shift (CIPS), Departure from Nucleate Boiling (DNB), and Pellet-Clad Interaction (PCI). Capability refers to evidence of required functionality for capturing phenomena of interest while credibility refers to the evidence that provides confidence in the calculated results. For this assessment, each challenge problem defines a set of phenomenological requirements against which the VERA software is assessed. This approach, in turn, enables the focused assessment of only those capabilities relevant to the challenge problem. The evaluation of VERA against the challenge problem requirements represents a capability assessment. The mechanism for assessment is the Sandia-developed Predictive Capability Maturity Model (PCMM) that, for this assessment, evaluates VERA on 8 major criteria: (1) Representation and Geometric Fidelity, (2) Physics and Material Model Fidelity, (3) Software Quality Assurance and Engineering, (4) Code Verification, (5) Solution Verification, (6) Separate Effects Model Validation, (7) Integral Effects Model Validation, and (8) Uncertainty Quantification. For each attribute, a maturity score from zero to three is assigned in the context of each challenge problem. The evaluation of these eight elements constitutes the credibility assessment for VERA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Siena Galaxy Atlas 2020

Abstract We present the 2020 version of the Siena Galaxy Atlas (SGA-2020), a multiwavelength optical and infrared imaging atlas of 383,620 nearby galaxies. The SGA-2020 uses optical grz imaging over ≈20,000 deg 2 from the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys Data Release 9 and infrared imaging in four bands (spanning 3.4–22 μ m) from the 6 year unWISE coadds; it is more than 95% complete for galaxies larger than R (26) ≈ 25″ and r < 18 measured at the 26 mag arcsec −2 isophote in the r band. The atlas delivers precise coordinates, multiwavelength mosaics, azimuthally averaged optical surface-brightness profiles, model images and photometry, and additional ancillary metadata for the full sample. Coupled with existing and forthcoming optical spectroscopy from the DESI, the SGA-2020 will facilitate new detailed studies of the star formation and mass assembly histories of nearby galaxies; enable precise measurements of the local velocity field via the Tully–Fisher and fundamental plane relations; serve as a reference sample of lasting legacy value for time-domain and multimessenger astronomical events; and more.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of pseudo-random binary arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown Point-Spread Function (PSF) of the instruments [1] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in a spatial frequency domain as a Power Spectral Density (PSD) distribution [2]. For example, the measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [3], [4]. The distortion of the surface PSD distribution due to the PSF can be modeled with the Modulation Transfer Function (MTF), which is defined over the spatial frequency bandwidth of the instrument [1], [2]. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the System Under Test (SUT). Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. In previous work [5], [6] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on Binary Pseudo-Random (BPR) gratings. Here, we present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription [7] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples. [8] Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

36 MATERIALS SCIENCE↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Aircraft measurements of BrO, IO, glyoxal, NO 2 , H 2 O, O 2 –O 2 and aerosol extinction profiles in the tropics: comparison with aircraft-/ship-based in situ and lidar measurements

Here, tropospheric chemistry of halogens and organic carbon over tropical oceans modifies ozone and atmospheric aerosols, yet atmospheric models remain largely untested for lack of vertically resolved measurements of bromine monoxide (BrO), iodine monoxide (IO) and small oxygenated hydrocarbons like glyoxal (CHOCHO) in the tropical troposphere. BrO, IO, glyoxal, nitrogen dioxide (NO 2 ), water vapor (H 2 O) and O 2 –O 2 collision complexes (O 4 ) were measured by the University of Colorado Airborne Multi-AXis Differential Optical Absorption Spectroscopy (CU AMAX-DOAS) instrument, aerosol extinction by high spectral resolution lidar (HSRL), in situ aerosol size distributions by an ultra high sensitivity aerosol spectrometer (UHSAS) and in situ H 2 O by vertical-cavity surface-emitting laser (VCSEL) hygrometer. Data are presented from two research flights (RF12, RF17) aboard the National Science Foundation/National Center for Atmospheric Research Gulfstream V aircraft over the tropical Eastern Pacific Ocean (tEPO) as part of the "Tropical Ocean tRoposphere Exchange of Reactive halogens and Oxygenated hydrocarbons" (TORERO) project (January/February 2012). We assess the accuracy of O 4 slant column density (SCD) measurements in the presence and absence of aerosols. Our O 4 -inferred aerosol extinction profiles at 477 nm agree within 6% with HSRL in the boundary layer and closely resemble the renormalized profile shape of Mie calculations constrained by UHSAS at low (sub-Rayleigh) aerosol extinction in the free troposphere. CU AMAX-DOAS provides a flexible choice of geometry, which we exploit to minimize the SCD in the reference spectrum (SCD REF , maximize signal-to-noise ratio) and to test the robustness of BrO, IO and glyoxal differential SCDs. The RF12 case study was conducted in pristine marine and free tropospheric air. The RF17 case study was conducted above the NOAA RV Ka'imimoana (TORERO cruise, KA-12-01) and provides independent validation data from ship-based in situ cavity-enhanced DOAS and MAX-DOAS. Inside the marine boundary layer (MBL) no BrO was detected (smaller than 0.5 pptv), and 0.2–0.55 pptv IO and 32–36 pptv glyoxal were observed. The near-surface concentrations agree within 30% (IO) and 10% (glyoxal) between ship and aircraft. The BrO concentration strongly increased with altitude to 3.0 pptv at 14.5 km (RF12, 9.1 to 8.6° N; 101.2 to 97.4° W). At 14.5 km, 5–10 pptv NO 2 agree with model predictions and demonstrate good control over separating tropospheric from stratospheric absorbers (NO 2 and BrO). Our profile retrievals have 12–20 degrees of freedom (DoF) and up to 500 m vertical resolution. The tropospheric BrO vertical column density (VCD) was 1.5 × 10 13 molec cm –2 (RF12) and at least 0.5 × 10 13 molec cm –2 (RF17, 0–10 km, lower limit). Tropospheric IO VCDs correspond to 2.1 × 10 12 molec cm –2 (RF12) and 2.5 × 10 12 molec cm –2 (RF17) and glyoxal VCDs of 2.6 × 10 14 molec cm –2 (RF12) and 2.7 × 10 14 molec cm –2 (RF17). Surprisingly, essentially all BrO as well as the dominant IO and glyoxal VCD fraction was located above 2 km (IO: 58 ± 5%, 0.1–0.2 pptv; glyoxal: 52 ± 5%, 3–20 pptv). To our knowledge there are no previous vertically resolved measurements of BrO and glyoxal from aircraft in the tropical free troposphere. The atmospheric implications are briefly discussed. Future studies are necessary to better understand the sources and impacts of free tropospheric halogens and oxygenated hydrocarbons on tropospheric ozone, aerosols, mercury oxidation and the oxidation capacity of the atmosphere.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling a generic TRISO-fueled heat pipe microreactor using SCALE: Depletion, transportation criticality, and shielding

This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.

Criticality↗

SU-D-9A-03: STAMP: Simulator for Texture Analysis in MRI/PET

Purpose: To develop a convenient simulation platform to facilitate PET/MR image analysis with the prospect of gaining a better understanding of the influence of acquisition parameters on PET/MRI textural features. The simulation platform is demonstrated by showing textural variations of a representative case study using different image acquisition parameters. Methods: The simulation platform is composed of MRI simulators JEMRIS and SIMRI to achieve simulations of customized MRI sequences on sample tumor models. The PET simulator GATE is used to get 2D and 3D Monte Carlo acquisitions of voxelized PET sources using a phantom geometry and a customized scanner architecture. The platform incorporates a series of graphical user interfaces written in Matlab. Two GUIs are used to facilitate communication with the simulation executables installed on a computer cluster. A third GUI is used to collect and display the clinical and simulated images, as well as fused PET/MRI images, and perform computation of textural features.To illustrate the capabilities of this platform, one FDG-PET and T1-weighted (T1w) digitized tumor models were generated from clinical images of a soft-tissue sarcoma patient. Numerically simulated MR images were produced using 3 different echo times (TE) and 5 different repetition times (TR). PET 2D images were simulated using an OSEM algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. Results: STAMP was successfully used to produce numerically simulated FDG-PET and MRI images, and to calculate their corresponding textures. Three typical textures (GLCM-Contrast, GLSZM-ZSV and NGTDM-Coarseness) were found to vary by a range of 45% on average compared to reference scanning conditions in the case of FDG-PET, and by a range of 40% in the case of T1w MRI. Conclusion: We have successfully developed a Matlab-based simulation platform to facilitate PET/MRI texture image analysis for outcome prediction.

60 APPLIED LIFE SCIENCES↗

Bioinformatics resource manager v2.3: an integrated software environment for systems biology with microRNA and cross-species analysis tools

Background: MicroRNAs (miRNAs) are noncoding RNAs that direct post-transcriptional regulation of protein coding genes. Recent studies have shown miRNAs are important for controlling many biological processes, including nervous system development, and are highly conserved across species. Given their importance, computational tools are necessary for analysis, interpretation and integration of high-throughput (HTP) miRNA data in an increasing number of model species. The Bioinformatics Resource Manager (BRM) v2.3 is a software environment for data management, mining, integration and functional annotation of HTP biological data. In this study, we report recent updates to BRM for miRNA data analysis and cross-species comparisons across datasets. Results: BRM v2.3 has the capability to query predicted miRNA targets from multiple databases, retrieve potential regulatory miRNAs for known genes, integrate experimentally derived miRNA and mRNA datasets, perform ortholog mapping across species, and retrieve annotation and cross-reference identifiers for an expanded number of species. Here we use BRM to show that developmental exposure of zebrafish to 30 uM nicotine from 6–48 hours post fertilization (hpf) results in behavioral hyperactivity in larval zebrafish and alteration of putative miRNA gene targets in whole embryos at developmental stages that encompass early neurogenesis. We show typical workflows for using BRM to integrate experimental zebrafish miRNA and mRNA microarray datasets with example retrievals for zebrafish, including pathway annotation and mapping to human ortholog. Functional analysis of differentially regulated (p<0.05) gene targets in BRM indicates that nicotine exposure disrupts genes involved in neurogenesis, possibly through misregulation of nicotine-sensitive miRNAs. Conclusions: BRM provides the ability to mine complex data for identification of candidate miRNAs or pathways that drive phenotypic outcome and, therefore, is a useful hypothesis generation tool for systems biology. The miRNA workflow in BRM allows for efficient processing of multiple miRNA and mRNA datasets in a single software environment with the added capability to interact with public data sources and visual analytic tools for HTP data analysis at a systems level. BRM is developed using Java™ and other open-source technologies for free distribution (http://www.sysbio.org/dataresources/brm.stm).

59 BASIC BIOLOGICAL SCIENCES↗

1D Atmosphere Models from Inversion of Fe i 630 nm Observations with an Application to Solar Irradiance Studies

Present-day semi-empirical models of solar irradiance (SI) variations reconstruct SI changes measured on timescales greater than a day by using spectra computed in one dimensional atmosphere models (1D models), which are representative of various solar surface features. Various recent studies have pointed out, however, that the spectra synthesized in 1D models do not reflect the radiative emission of the inhomogenous atmosphere revealed by high-resolution solar observations. We aimed to derive observation-based atmospheres from such observations and test their accuracy for SI estimates. We analyzed spectropolarimetric data of the Fe i 630 nm line pair in photospheric regions that are representative of the granular quiet-Sun pattern (QS) and of small- and large-scale magnetic features, both bright and dark with respect to the QS. The data were taken on 2011 August 6, with the CRisp Imaging Spectropolarimeter at the Swedish Solar Telescope, under excellent seeing conditions. We derived atmosphere models of the observed regions from data inversion with the SIR code. We studied the sensitivity of results to spatial resolution and temporal evolution, and discuss the obtained atmospheres with respect to several 1D models. The atmospheres derived from our study agree well with most of the 1D models we compare our results with, both qualitatively and quantitatively (within 10%), except for pore regions. Spectral synthesis computations of the atmosphere obtained from the QS observations return an SI between 400 and 2400 nm that agrees, on average, within 2.2% with standard reference measurements, and within −0.14% with the SI computed on the QS atmosphere employed by the most advanced semi-empirical model of SI variations.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin–Orbit Coupling Constants in Atoms and Ions of Transition Elements: Comparison of Effective Core Potentials, Model Core Potentials, and All-Electron Methods

The spin–orbit coupling constants (SOCC) in atoms and ions of the first- through third-row transition elements were calculated for the low-lying atomic states whose main electron configuration is [ n d] q ( q = 1–4 and 6–9, n = the principal quantum number), using four different approaches: (1) a nonrelativistic Hamiltonian used to construct multiconfiguration self-consistent field (MCSCF) wave functions utilizing effective core potentials and their associated basis sets within the framework of second-order configuration interaction (SOCI) to calculate spin–orbit couplings (SOC) using one-electron Breit–Pauli Hamiltonian (BPH), (2) a nonrelativistic Hamiltonian used to construct MCSCF wave functions utilizing model core potentials and their associated basis sets within the framework of SOCI to calculate SOC using the full BPH, (3) nonrelativistic and spin-independent relativistic Hamiltonians used to construct MCSCF wave functions utilizing all-electron (AE) basis sets within the framework of SOCI to calculate SOC using the full BPH, and (4) a relativistic Hamiltonian given by the exact two-component (X2C) transformation for construction of Kramers-restricted relativistic configuration interaction wave functions. In this investigation, these four approaches are referred to as ECP, MCP, AE, and X2C methods, respectively. The ECP, MCP, and AE methods are so-called two-step approaches (TSA), while the X2C method is a one-step approach (OSA). In the AE method, three different calculations—relativistic elimination of small components (RESC), third-order Douglas–Kroll–Hess (DKH3), and infinite-order two-component (IOTC) relativistic correction—were performed for the estimation of the scalar relativistic components in addition to those of the nonscalar relativistic (NSR) contributions. The calculated SOCC are compared to the available experimental data via the Landé interval rule. Although there are several exceptions, including states whose main configuration is [ n d] 5 , the average differences between the ECP and AE (IOTC) SOCC and between the ECP and the X2C SOCC are mostly less than 20%. The differences between the ECP and the experimental SOCC are even smaller. No serious discrepancy was found between the TSA and OSA predictions of SOCC for the first- and second-row transition elements in comparison to experiment. For atoms and ions of the third-row transition elements, the SOCC calculated through the Landé interval rule are not reliable. The low-energy spin-mixed (SM) states originating from a [5d]q configuration ( q = 2–4) have a larger energy lowering due to the SOC effects, in comparison with those for atoms and ions of the first- and second-row transition elements. For the spin-mixed (SM) states originating from a [5d]q configuration ( q = 6–8), the energy lowering of all 4 F 7/2 , 5 D 1 , and 5 D 3 states due to the SOC effects is smaller than those of the other SM states. Furthermore this difficulty, which also arises for the MCP, AE, and X2C (OSA) approaches, suggests that the LS-coupling scheme is inappropriate.

74 ATOMIC AND MOLECULAR PHYSICS↗