Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Pt: Ti Diffusion Barrier, Interconnect, and Simultaneous Ohmic Contacts to n- and p-type 4H-SiC

We report the initial results of using co-sputtered Pt:Ti 80:20 at. % composition ratio metallization as a diffusion barrier against gold (Au) and oxygen (O), as an interconnect layer, as well as forming simultaneous ohmic contacts to n-and p-type 4H-SiC. Having a single conductor with such combined multi-functional attributes would appreciably reduce the fabrication costs, processing time and complexity that are inherent in the production of SiC based devices. Auger Electron Spectroscopy, Focused Ion Beam-assisted Field Emission Scanning Electron Microscopy and Energy Dispersive Spectroscopy analyses revealed no Au and O migration to the SiC contact surface and minimal diffusion through the Pt:Ti barrier layer after 15 minutes of exposure at 800 °C in atmosphere, thus offering potential long term stability of the ohmic contacts. Specific contact resistance values of 7 x 10(exp -5) and 7.4 x 10(exp -4) Ω-sq.cm were obtained on the n (N(sub d)=7 x 10(exp 18) per cu.cm and p (N(sub a)=2 x 10(exp 20) per cu. cm) -type 4H-SiC, respectively. The resistivity of 75 μΩ-cm was obtained for the Pt:Ti layer that was sandwiched between two SiO2 layers and annealed in pure O ambient up to 900 °C, which offers promise as a high temperature interconnect metallization.

Simultaneous Ohmic Contact↗

Scanning delay generator for measurement of kinetic decays using laser-induced fluorescence techniques

An electronic device is described which generates a delayed pulse, where the delay is increased in a step-like manner. This device finds application in the measurement of kinetic decays, particularly when laser-induced fluorescent (LIF) detection of the decaying species is used. The circuit uses 15 low-power Schottky TTL chips and is contained within a dual width NIM module.

Halpern, J. B.↗

A comparison of screening techniques for ceramic capacitors

The techniques involved are ultrasonic scanning, neutron radiography, scanning laser acoustic microscopy, and voltage conditioning. The test capacitor, for this first phase, is a 0.47 uF, 50V capacitor style CKR06. Eighteen of 768 devices failed in voltage conditioning with elapsed times from 15 minutes to 1239 hours. Eleven of the failures were detected by ultrasonic scanning. Four failures were found by neutron radiography. Fourteen failures showed up in the acoustic microscopy test. Three failures in voltage conditioning were not detected by any of the techniques. Failures were confirmed by destructive physical analysis. There is no direct relationship between the size of the defect and electrical failure.

Kiernan, G. F.↗

Methods of Measurement for Semiconductor Materials, Process Control, and Devices

The development of methods of measurement for semiconductor materials, process control, and devices is reported. Significant accomplishments include: (1) Completion of an initial identification of the more important problems in process control for integrated circuit fabrication and assembly; (2) preparations for making silicon bulk resistivity wafer standards available to the industry; and (3) establishment of the relationship between carrier mobility and impurity density in silicon. Work is continuing on measurement of resistivity of semiconductor crystals; characterization of generation-recombination-trapping centers, including gold, in silicon; evaluation of wire bonds and die attachment; study of scanning electron microscopy for wafer inspection and test; measurement of thermal properties of semiconductor devices; determination of S-parameters and delay time in junction devices; and characterization of noise and conversion loss of microwave detector diodes.

Bullis, W. M.↗

Use a SEM on a production line

Scanning electron microscope for poor metallization detection in manufacturing cycle of semiconductor devices

Adolphsen, J. W.↗

Overview of Terra and Aqua MODIS Status

This presentation will consist of two one-hour lectures. The first lecture will review the characteristics of the MODIS instrument and how it responds to the performance specifications. The pre-launch and on-orbit procedures and results to characterize and maintain instrument output so as to allow the prescribed science to be done will also be outlined. This will include defining the equations used to account for gain changes and any degradation in the optics of the instrument or the on-board calibration devices themselves. The changes in the solar diffuser and the radiance versus scan angle performance of the scan mirror will also be reviewed. Overall it will be shown that the instrument has and is meeting specifications of 2% reflectance relative to the sun, 5% in the radiance observed in the reflected solar radiation bands, and 0.5-1% in the thermal bands. The second lecture will review and describe highlights in the geophysical products and related science results. There are approximately 40 geophysical products related to observations of land, ocean and atmosphere features. Many of the results are unprecedented and offer considerable advances over those achievable with heritage instruments such as the NOAA Advanced Very High Resolution Radiometer (AVHRR). The literature is showing a steady growth of publications in scientific journals using MODIS data or products. The future is also bright in that a follow-on instrument based on the MODIS will be flown on the National Polar-Orbiting Environmental Satellite Series (NPOESS) starting around 2010.

Salomonson, Vincent V.↗

Semiconductor Reference Oscillator Development for Coherent Detection Optical Remote Sensing Applications

The NASA Earth Science Enterprise Advanced Technology Initiatives Program is supporting a program for the development of semiconductor laser reference oscillators for application to coherent optical remote sensing from Earth orbit. Local oscillators provide the frequency reference required for active spaceborne optical remote sensing concepts that involve heterodyne (coherent) detection. Two recent examples of such schemes are Doppler wind lidar and tropospheric carbon dioxide measurement by laser absorption spectrometry, both of which are being proposed at a wavelength of 2.05 microns. Frequency-agile local oscillator technology is important to such applications because of the need to compensate for large platform-induced Doppler components that would otherwise interfere with data interpretation. Development of frequency-agile local oscillator approaches has heretofore utilized the same laser material as the transmitter laser (Tm,Ho:YLF in the case of the 2.05-micron wavelength mentioned above). However, a semiconductor laser-based frequency-agile local oscillator offers considerable scope for reduced mechanical complexity and improved frequency agility over equivalent crystal laser devices, while their potentially faster tuning capability suggest the potential for greater scanning versatility. The program we report on here is specifically tasked with the development of prototype novel architecture semiconductor lasers with the power, tunability, and spectral characteristics required for coherent Doppler lidar. The baseline approach for this work is the distributed feedback (DFB) laser, in which gratings are etched into the semiconductor waveguide structures along the entire length of the laser cavity. However, typical DFB lasers at the wavelength of interest have linewidths that exhibit unacceptable growth when driven at the high currents and powers that are required for the Doppler lidar application. Suppression of this behavior by means of corrugation pitch-modulation (using a detuned central section to prevent intensity peaking in the center of the cavity) is currently under investigation to achieve the required performance goals.

distributed feedback (DFB) laser↗

Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks

In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.

Source record↗

MMIC antenna technology development in the 30/20 gigahertz band

This paper presents a progress summary of NASA's efforts in developing 20 and 30 GHz GaAs MMIC devices and an advanced satellite communications antenna system using these devices. In the interest of preserving resources such as frequency spectrum and orbital space the antenna system is being developed with multiple fixed spot beams and multiple scanning spot beams. NASA set high goals for the MMIC development to pushc GaAs technology. These goals and the main features of the MMIC devices are discussed. Some packaging and characterization considerations are also discussed. The 20 GHz transmit antenna and 30 GHz receive antenna are being developed separately. The approach selected is to perform contractual configuration studies, purchase a 20-GHz experimental antenna system (EAS) and perform in-house evaluation. The features and key specifications of the EAS are discussed. Additional supporting technologies such as effects of coupling on modest sized arrays, MMIC matching techniques, in-house analytical capability, wideband and dual frequency microstrip patch array development, and MMIC packaging techniques are described. Some plans for future are also discussed.

Smetana, J.↗

MMIC antenna technology development in the 30/20 gigahertz band

This paper presents a progress summary of NASA's efforts in developing 20 and 30 GHz GaAs MMIC devices and an advanced satellite communications antenna system using these devices. In the interest of preserving resources such as frequency spectrum and orbital space the antenna system is being developed with multiple fixed spot beams and multiple scanning spot beams. NASA set high goals for the MMIC development to push GaAs technology. These goals and the main features of the MMIC devices are discussed. Some packaging and characterization considerations are also discussed. The 20 GHz transmit antenna and 30 GHz receive antenna are being developed separately. The approach selected is to perform contractual configuration studies, purchase a 20-GHz experimental antenna system (EAS) and perform in-house evaluation. The features and key specifications of the EAS are discussed. Additional supporting technologies such as effects of coupling on modest sized arrays, MMIC matching techniques, in-house analytical capability, wideband and dual frequency microstrip patch array development, and MMIC packaging techniques are described. Some plans for future work are also discussed.

Smetana, J.↗

The development of spectro-signature indicators of root disease

The development and testing of airborne sensors that might be effective in discrimination root rot infected trees from healthy ones are outlined. The sensing device is composed of a thermal infrared radiometer and an instant replay video scan system.

Wear, J. F.↗

A large granite stage and measuring microscope.

A stage and measuring microscope servocontrolled by a computer have been constructed. The travel of the stage is 0.5 x 0.5 m and the travel of the microscope objective is 7.5 cm. The measuring accuracy is 1 micron in the x-y plane and 5 microns along the z axis. The mechanical and optical construction of the stage and microscope, as well as the way in which the control electronics are organized, permit great flexibility of operation. Possible applications include the scanning and measuring of astronomical plates, the laying out of patterns of semiconductor devices of very large sizes, and the measurement of precision grids.

Alston-Garnjost, M.↗

Inexpensive portable drug detector

Inexpensive, easy-to-use, self-scanning, self-calibrating, portable unit automatically graphs fluorescence spectrum of drug sample. Device also measures rate of movement through chromatographic column for forensic and medical testing.

Dimeff, J.↗

Optical integrated-circuit tester

Computer controlled device can check typical medium scale unit in less than one minute. System scans integrated circuit chip with narrow beam of light while simultaneously scanning reference chip.

Micka, E. A.↗

Outer planet investigations using a CCD camera system

Problems related to analog noise, data transfer from the camera buffer to the storage computer, and loss of sensitivity of a two dimensional charge coupled device imaging system are reported. To calibrate the CCD system, calibrated UBV pinhole scans of the Saturn disk were obtained with a photoelectric area scanning photometer. Atmospheric point spread functions were also obtained. The UBV observations and models of the Saturn atmosphere are analyzed.

Price, M. J.↗

Search for near-Earth asteroids with the spacewatch camera

The Spacewatch Program began as an engineering development of the discovery of near-earth asteroids and comets, with the firs observations starting in 1983, using an RCA charge coupled device (CCD) that has 320 x 512 pixels. Extensive software was written to scan the sky and learn how to do astrometry for precise orbits of newly discovered objects. The merit of the concept was proven, with many observations reported and comets recovered. The precision of astrometric observations for comets and asteroids was improved. For efficient scanning and discovery of new objects, a Tektronix 2048 x 2048 CCD was obtained and is now permanently on the Spacewatch Telescope. Other aspects of the Spacewatch Program are briefly discussed.

Gehrels, T.↗