Search NASA⌕ Search

SEARCH · Search NASA

Results for “SLAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

MEASUREMENT OF Fn 2 /Fp 2 FROM DEEP INELASTIC ELECTRON SCATTERING OFF A=3 MIRROR NUCLEI AT JEFFERSON LAB

This research is part of the Je?erson Lab MARATHON experiment (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A = 3 EMC E?ect in Deep Inelastic Electron Scattering Off the Tritium and Helium MirrOr Nuclei). MARATHON is an experiment on electron deep inelastic scattering off the 3H, 3He mirror nuclei. It has extracted, from the measured deep inelastic scattering cross section ratio o? 3H and 3He, the ratio of the neutron to proton inelastic structure functions Fn 2 /Fp 2 . The extraction has taken advantage of the isospin symmetry of the A = 3 mirror nuclei within a novel technique, which avoids the theoretical uncertainties that are present in the SLAC experiments of the 1970s, which used hydrogen and deuterium targets. The experiment was performed using the upgraded 11 GeV beam of the Jefferson Lab electron accelerator, the Hall A Experimental Facility, and a newly designed cryogenic, high-pressure gas target system containing 3H and 3He cells. Electrons scattered o? the gas targets were detected in the two superconducting, high-resolution magnetic spectrometers of Hall A. The cross section data cover the four-momentum transfer squared range 2.0 < Q2 < 14.0 (GeV/c)2, and the Bjorken x scaling variable range 0.19 < x < 0.83. The experiment also measured, for calibration purposes, electron deep inelastic scattering off hydrogen and deuterium at selected kinematics.

Su, Tong↗

Stochastic Look Ahead Commitment: A Computational Perspective

This presentation gives an overview of a stochastic look ahead commitment (SLAC) problem for managing transmission grid uncertainty in the near- to medium-term (15 minutes to a few hours). We discuss formulation and solution methods, as well as application to transmission system operations.

27 ARPA - Advanced Research Projects Agency-Energy↗

Dual Energies in the LCLS Copper Linac

For LCLS-II two undulators were installed at SLAC, one for soft and one for hard x-rays. Before the super-conducting linac gets turned on the copper linac is providing beams at 120 Hz to these two beam destinations. The 120 Hz can be split in many different ratios between soft and hard via a pulsed magnet. To get an optimized beam for the quite different photon energies the pulsed linac components like modulators and RF can provide many different beam parameters, mainly energies and bunch lengths for the two undulator lines. How this was implemented with timing setups of triggers and finally after the split the necessary matching of the transverse phase space will be discussed.

Decker, Franz-Josef↗

Laboratory Measurements of Instrumental Signatures of the LSST Camera Focal Plane

Electro-optical testing and characterization of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Camera focal plane, consisting of 205 charge-coupled devices (CCDs) arranged into 21 stand-alone Raft Tower Modules (RTMs) and 4 Corner Raft Tower Modules (CRTMs), is currently being performed at the SLAC National Accelerator Laboratory. Testing of the camera sensors is performed using a set of custom-built optical projectors, designed to illuminate the full focal plane or specific regions of the focal plane with a series of light illumination patterns: the crosstalk projector, the flat illuminator projector, and the spot grid projector. In addition to measurements of crosstalk, linearity and full well, the ability to project realistically-sized sources, using the spot grid projector, makes possible unique measurements of instrumental signatures such as deferred charge distortions, astrometric shifts due to sensor effects, and the brighter-fatter effect, prior to camera first light. Here we present the optical projector designs and usage, the electro-optical measurements and how these results have been used in testing and improving the LSST Camera instrumental signature removal algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Durable Module Materials Consortium (DuraMAT) FY 2021 Annual Report: New Results and a Renewed Consortium

The Durable Module Materials Consortium (DuraMAT) is a multi-lab consortium led by the National Renewable Energy Laboratory, with Sandia National Laboratories, SLAC National Accelerator Laboratory, and Lawrence Berkeley National Laboratory as core research labs. DuraMAT's overarching goal is to discover, develop, de-risk, and enable the rapid commercialization of improved materials, designs, predictive tests, and models for photovoltaic (PV) modules that increase performance, extend lifetime, and enable new applications. Technical results are highlighted throughout this report, and the new projects awarded for FY 2022 address many of the challenges to making 50-year, high-energy-yield modules that were identified in these working groups.

backsheet↗

200 MV Record Voltage Of vCM And LCLS-II-HE Cryomodules Production Start At Fermilab

The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to the facility, enabling higher energy operation. An electron beam is accelerated using superconducting radio frequency (SRF) cavities built into cryomodules. It is planned to build 24 1.3 GHz standard cryomodules and one 1.3 GHz single-cavity Buncher Capture Cavity (BCC) cryomodule for the LCLS-II-HE project. Fourteen of these standard cryomodules and the BCC are planned to be assembled and tested at Fermilab. Procurements for standard cryomodule components are nearing completion. The first LCLS-II-HE cryomodule, referred to as the verification cryomodule (vCM) was assembled and tested at Fermilab. Fermilab has completed the assembly of the second cryomodule. This paper presents LCLS-II-HE cryomodule production status at Fermilab, emphasizing the changes done based on the successes, challenges, mitigations, and lessons learned from LCLS-II; validation of the changes with the excellent vCM results.

43 PARTICLE ACCELERATORS↗

FACET-II

FACET-II is a National User Facility at SLAC National Accelerator Laboratory providing 10 GeV electron beams with µm·rad normalised emittance and peak currents exceeding 100 kA. FACET-II operates as a National User Facility while engaging a broad User community to develop and execute experimental proposals that advance the development of plasma wakefield accelerators. FACET-II is currently commissioned and has started with first experiments. The special features of FACET-II will be shown and first results from the experiments.

Clark, Christine↗

Towards Unlocking Insights from Logbooks Using AI

Electronic logbooks contain valuable information about activities and events concerning their associated particle accelerator facilities. However, the highly technical nature of logbook entries can hinder their usability and automation. As natural language processing (NLP) continues advancing, it offers opportunities to address various challenges that logbooks present. This work explores jointly testing a tailored Retrieval Augmented Generation (RAG) model for enhancing the usability of particle accelerator logbooks at institutes like DESY, BESSY, Fermilab, BNL, SLAC, LBNL, and CERN. The RAG model uses a corpus built on logbook contributions and aims to unlock insights from these logbooks by leveraging retrieval over facility datasets, including discussion about potential multimodal sources. Our goals are to increase the FAIR-ness (findability, accessibility, interoperability, and reusability) of logbooks by exploiting their information content to streamline everyday use, enable macro-analysis for root cause analysis, and facilitate problem-solving automation.

43 PARTICLE ACCELERATORS↗

Exclusive η Electro-Production Beam Spin Asymmetry Measurements using CLAS12 at Jefferson Lab

The exploration of nucleon structure and electromagnetic transitions from ground-state to excited-state is a cornerstone of nuclear physics research. Meson electro-production experiments have opened new avenues for investigating these phenomena, particularly in the 12 GeV era at Jefferson Lab with the CLAS12 spectrometer. The ?N final states, accessible only through isospin resonances I = 1/2, provide a unique tool for studying nucleon excitations. By simplifying the analysis and enabling a cleaner extraction of resonance properties compared to the extensively studied ?N final states, ? electroproduction offers a complementary approach to unraveling the structure of excited nucleons. This work presents the first-ever measurement of the beam spin asymmetry (BSA) in exclusive ? electroproduction, covering a previously unexplored kinematic region with 1.6 ? W ? 2.2 GeV. The BSA is extracted from the CLAS12 data using a comprehensive analysis framework that carefully considers the statistical limitations of the data set. The results are compared to predictions from theoretical models, such as the Jülich-Bonn-Washington (JBW) and MAID, as well as compared to previously published cross-section and spin observable results from CLAS and SLAC. Notably, the extracted BSA exhibits discrepancies with the model predictions, highlighting the potential for refining theoretical descriptions of nucleon resonances and their electromagnetic couplings through the incorporation of these new data. The high precision data obtained in this previously unmeasured kinematic region now serve as valuable input for theorists to refine their models.

Illari, Isabella↗

Report from the Workshop on Xenon Detector $0\nu\beta\beta$ Searches: Steps Towards the Kilotonne Scale

These proceedings summarize the program and discussions of the ``Workshop on Xenon Detector $0\nu\beta\beta$ Searches: Steps Towards the Kilotonne Scale'' held on October 25-27 2023 at SLAC National Accelerator Laboratory. This workshop brought together experts from the communities of neutrinoless double-beta decay and dark matter detection, to discuss paths forward for the realization of monolithic experiments with xenon approaching the kilotonne scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Imaging Valence Electron Rearrangement in a Chemical Reaction Using Hard X-Ray Scattering

We have observed the signatures of valence electron rearrangement in photoexcited ammonia using ultrafast hard x-ray scattering. Time-resolved x-ray scattering is a powerful tool for imaging structural dynamics in molecules because of the strong scattering from the core electrons localized near each nucleus. Such core-electron contributions generally dominate the differential scattering signal, masking any signatures of rearrangement in the chemically important valence electrons. Ammonia represents an exception to the typically high core-to-valence electron ratio. Here, we measured 9.8 keV x-ray scattering from gas-phase deuterated ammonia following photoexcitation via a 200 nm pump pulse to the 3s Rydberg state. We observed changes in the recorded scattering patterns due to the initial photoexcitation and subsequent deuterium dissociation. Ab initio calculations confirm that the observed signal is sensitive to the rearrangement of the single photoexcited valence electron as well as the interplay between adiabatic and nonadiabatic dissociation channels. The use of ultrafast hard x-ray scattering to image the structural rearrangement of single valence electrons constitutes an important advance in tracking valence electronic structure in photoexcited atoms and molecules.

Gabalski, Ian [SLAC National Accelerator Laborator↗

Elucidating Norrish type I reactive pathways by ultrafast X-ray absorption spectroscopy

Norrish type I reactions selectively cleave carbon–carbon bonds directly adjacent to carbonyl groups. Despite their broad use in combination with aromatic carbonyls for additive manufacturing and dental UV curing applications, the nature of the photochemically active state and its population mechanism remain insufficiently understood. Detailed mechanistic insight requires mapping of the photoexcited population flow involving internal conversion and intersystem crossing. We present a time-domain study of gas phase acetophenone as a prototypical aromatic carbonyl combining soft X-ray time-resolved near-edge X-ray absorption fine structure (TR-NEXAFS) spectroscopy at the oxygen K-edge with ab initio multiple spawning (AIMS) simulations. Exploiting the specific sensitivity of TR-NEXAFS spectroscopy to states with nπ* character, we observe population transfer from the initially excited 1 ππ* state to the 1 nπ* state with a time constant of (0.13 ± 0.02) ps after an initial induction period of (0.12 ± 0.02) ps without population transfer, in quantitative agreement with the AIMS simulations. The population in the 1 nπ* state subsequently decays via intersystem crossing, likely mediated by a 3 ππ* state, within (3.17 ± 0.66) ps to a long-lived 3 nπ* state, which is presumed to be active towards Norrish type I chemistry.

Graßl, Martin [SLAC National Accelerator Laborator↗

Attosecond X-Ray Core-Level Chronoscopy of Aromatic Molecules

Attosecond photoemission or photoionization delays are a unique probe of the structure and the electronic dynamics of matter. However, the spectral congestion of valence photoelectron spectra sets fundamental limits to the complexity of systems that can be studied, and the delocalization of valence electron wave functions blurs the spatial origin of the photoelectron wave packet. Using attosecond x-ray pulses from LCLS, we demonstrate the key advantages of measuring core-level delays: The photoelectron spectra remain atomlike, the measurements become element specific, and the observed scattering dynamics originate from a pointlike source when multicenter interference effects are negligible. We exploit these unique features to reveal the effects of changing functional groups (C-H vs N) and symmetry on attosecond scattering dynamics by measuring and calculating the photoionization delays between N−1⁢𝑠 and C−1⁢𝑠 core shells of a series of aromatic azabenzene molecules. Remarkably, the delays increase with the number of nitrogen atoms in the molecule and reveal multiple resonances. We identify two previously unknown mechanisms regulating the associated attosecond dynamics, namely the enhanced confinement of the trapped wave function with the replacement of C-H groups by N atoms and the decrease of the coupling strength among the photoemitted partial waves with increasing symmetry. This study demonstrates the unique opportunities opened by measurements of core-level photoionization delays for unraveling attosecond electron dynamics in complex matter.

Ji, Jia-Bao [Eidgenoessische Technische Hochschule↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗