Search NASA⌕ Search

SEARCH · Search NASA

Results for “Schottky diode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Longevity evaluation of SiC based alpha voltaic batteries with surface alpha sources

The alpha emitting actinide 241 Am is electrodeposited on the surface of the Pt electrode of in-house fabricated SiC Schottky diodes. With 17 nCi 241 Am directly coated on the top of a device, the 2-pi geometry yields a high energy (5.486 MeV) and a long-term irradiation accumulating to a high fluence (1.6 × 10 9 alpha particles’ infusion/month). The forward, reverse I/V, and dark current, are periodically measured to monitor key characteristics of device durability for any sign of degradation over time. The direct deposition of actinides on the surface of the device also enables the evaluation of radiation damage through alpha particles’ energy spectroscopic performance, which shows a clear spectrum degradation that can be reversed by optical excitation of the device prior to spectrum acquisition. As an analytical aide, the device performance is also simulated by Allpix 2 . Lastly, this study provides an insight into the durability of 4H-SiC as an energy converter option for alpha-voltaic batteries and the survivability in the other harsh environment found in nuclear fuel cycle, high energy physics, fission, fusion, and space exploration where rad-hard sensors are required.

Americium↗

Commissioning of the LCLS-II Prototype HOM Detectors with Tesla-Type Cavities at Fast

Experiments at the Fermilab Accelerator Science and Technology* (FAST) facility detected electron beam-induced high order mode (HOM) signals from Tesla superconducting cavities. This paper describes some of the signal detection hardware used in this experiment, as well as measurements of the HOM signal magnitude versus beam trajectory. These measurements were made both with a single bunch and with a train of 50 bunches at bunch charges from 400 pC/b down to 10 pC/b. The detection hardware is designed for use with the Tesla superconducting cavities of LCLS-II at SLAC** and is based on a prototype already in use at Fermilab. The HOM signal passes through a bandpass filter that is centered on several cavity dipole modes and a zero bias Schottky diode detects its magnitude. Direct comparisons were made between the FNAL chassis and the SLAC prototype for identical beam steering conditions. To support measurements with bunch charges as low as 10 pC, the SLAC detector has RF amplification between the bandpass filter and the diode detector. With this hardware, usable HOM signal measurements are obtained with a single bunch of 10 pC in cryomodule cavities as will be needed for LCLS-II.

43 PARTICLE ACCELERATORS↗

Schottky contacts on ultra-high-pressure-annealed GaN with high rectification ratio and near-unity ideality factor

Here we investigate the electrical characteristics of Ni Schottky contacts on n-type GaN films that have undergone ultra-high-pressure annealing (UHPA), a key processing step for activating implanted Mg. Contacts deposited on these films exhibit low rectification and high leakage current compared to contacts on as-grown films. By employing an optimized surface treatment to restore the GaN surface following UHPA, we obtain Schottky contacts with a high rectification ratio of ~10 9 , a near-unity ideality factor of 1.03, and a barrier height of ~0.9 eV. These characteristics enable the development of GaN junction barrier Schottky diodes employing Mg implantation and UHPA.

42 ENGINEERING↗

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

A new mixer design for 140-220 GHz

A new Schottky-diode mixer is described which has low noise and conversion loss in the 140-220-GHz band. At 170 GHz mixer noise temperatures of 1100-1300 K have been measured, with 6.2-7.2-dB single sideboard conversion loss. The design should be usable up to about 300 GHz with appropriate scaling. The mixer has been successfully used in airborne radiometers on the NASA Convair 990 and C-141 aircraft.

Kerr, A. R.↗

Annual Conference on Nuclear and Space Radiation Effects, 14th, College of William and Mary, Williamsburg, Va., July 12-15, 1977, Proceedings

Topics related to processing and hardness assurance are considered, taking into account the radiation hardening of CMOS technologies, technological advances in the manufacture of radiation-hardened CMOS integrated circuits, CMOS hardness assurance through process controls and optimized design procedures, the application of operational amplifiers to hardened systems, a hard off-the-shelf SG1524 pulse width modulator, and the gamma-induced voltage breakdown anomaly in a Schottky diode. Basic mechanisms are examined, giving attention to chemical and structural aspects of the irradiation behavior of SiO2 films on silicon, experimental observations of the chemistry of the SiO2/Si interface, leakage current phenomena in irradiated SOS devices, the avalanche injection of holes into SiO2, the low-temperature radiation response of Al2O3 gate insulators, and neutron damage mechanisms in silicon at 10 K. Other subjects discussed are related to radiation effects in devices and circuits, space radiation effects, and aspects of simulation, energy deposition, and dosimetry.

Stahl, R. H.↗

Detection of upper atmospheric constituents using submillimeter wave /SMMW/ heterodyne radiometry

Submillimeter wave heterodyne radiometry has been applied to the detection and sounding of upper atmospheric constituents. The use of room-temperature Schottky-diode mixers for the receivers has yielded measurements of 70,000 K noise temperature. Coupling losses into the diode and matching of the IF output limit are observed to limit noise temperature. The technique is evaluated by calculating spectra with assumed temperature and constituent profiles. Vertical integrations are made with a multilayer atmosphere and the direct summation of absorption coefficients for the individual spectral lines is used. Results are presented for tangent path parameters for a mid-latitude summer model and the fractional parts of upper atmospheric constituents as a function of altitude.

Mcavoy, N.↗

Back wall solar cell

A solar cell is disclosed which comprises a first semiconductor material of one conductivity type with one face having the same conductivity type but more heavily doped to form a field region arranged to receive the radiant energy to be converted to electrical energy, and a layer of a second semiconductor material, preferably highly doped, of opposite conductivity type on the first semiconductor material adjacent the first semiconductor material at an interface remote from the heavily doped field region. Instead of the opposite conductivity layer, a metallic Schottky diode layer may be used, in which case no additional back contact is needed. A contact such as a gridded contact, previous to the radiant energy may be applied to the heavily doped field region of the more heavily doped, same conductivity material for its contact.

Brandhorst, H. W., Jr.↗

The low-noise 115-GHz receiver on the Columbia-GISS 4-ft radio telescope

The superheterodyne millimeter-wave radiometer on the Columbia-GISS 4-ft telescope is described. This receiver uses a room-temperature Schottky diode mixer, with a resonant-ring filter as LO diplexer. The diplexer has low signal loss, efficient LO power coupling, and suppresses most of the LO noise at both sidebands. The receiver IF section has a parametric amplifier as its first stage with sufficient gain to overcome the second-stage amplifier noise. A broad-banded quarter-wave impedance transformer minimizes the mismatch between mixer and paramp. At 115 GHz, the SSB receiver noise temperature is 860 K, which is believed to be the lowest figure so far reported for a room-temperature receiver at this frequency.

Cong, H.-I.↗

Semiconductor millimeter and centimeter wave radiometer for the study of the radiation of an underlying surface

A theoretical and experimental investigation of a superheterodyne radiometer system with input frequency converter and intermediate frequency modulation is presented. Conditions are found, at which the temperature sensitivity of the device does not deteriorate. A sensitivity function to external parameters (temperature, heterodyne power) of a radiometer system with intermediate frequency modulation and a Schottky diode frequency converter is presented and calculated. Use of a frequency converter at the second harmonic of the heterodyne permitted simplication of the radiometer design and the use of a semiconductor heterodyne. A 3 cm range intermediate frequency amplifier permitted the use of centimeter wave radiometer signals. Fluctuation sensitivity of radiometers with a 1 sec time constant is 0.3 K at 3.4 mm and 0.06 K at 3 cm.

Bordonskiy, G. S.↗

Heterodyne detection of the 752.033-GHz H2O rotational absorption line

A tunable high resolution two stage heterodyne radiometer was developed for the purpose of investigating the intensity and lineshape of the 752.033 GHz rotational transition of water vapor. Single-sideband system noise temperatures of approximately 45,000 K were obtained using a sensitive GaAs Schottky diode as the first stage mixer. First local oscillator power was supplied by a CO2 laser pumped formic acid laser (761.61 GHz), generating an X-band IF signal with theoretical line center at 9.5744 GHz. Second local oscillator power was provided by means of a 3 GHz waveguide cavity filter with only 9 dB insertion loss. In absorption measurements of the H2O taken from a laboratory simulation of a high altitude rocket plume, the center frequency of the 752 GHz line was determined to within 1 MHz of the reported value. A rotational temperature 75 K, a linewidth 5 MHz and a Doppler shift 3 MHz were measured with the line-of-sight intersecting the simulated-plume axis at a distance downstream of 30 nozzle diameters. These absorption data were obtained against continuum background radiation sources at temperatures of 1175 and 300 K.

Dionne, G. F.↗

Far infrared heterodyne systems

Three far infrared detectors, the InSb hot electron bolometer, the GaAs Schottky diode and the Josephson point contact junction, were incorporated as mixers into sensitive heterodyne systems. The performances of existing heterodyne receivers/radiometers using these detectors are described and compared. Other applications of submillimeter heterodyne techniques are discussed.

Tannenwald, P. E.↗

Space applications of superconductivity - Microwave and infrared detectors

This is the fifth of a seven part series on the potential applications of superconductivity in space. The potential of superconducting microwave and infrared detectors for space applications is reviewed. The devices considered include bolometers, super-Schottky diodes and Josephson junctions operating as oscillators, mixers, and parametric amplifiers. In each case the description includes the physical mechanism, theoretical limits and the current state of the art for the superconducting device as well as its nonsuperconducting competitors.

Hamilton, C. A.↗

Pressure shift in the 170-micron emission of the CW optically pumped CH3OH laser

Pressure shifts of +15 MHz torr were observed in 16(8)-16(7) 170-micron CW CH3OH optically pumped laser emission. The experiments were performed using a harmonic mixing technique in a Schottky diode. The results are explained in terms of a second-order dipole-dipole interaction in a statistical formulation.

Lawandy, N. M.↗

A stable submillimeter laser local oscillator for heterodyne radiometry and spectroscopy

A submillimeter laser with off-axis pump beam injection is described. This design concept achieves complete isolation of the pump laser with respect to the pump radiation reflected from the submillimeter resonator. Active line independent stabilization of the pump laser is obtained by the use of an external tunable etalon as a frequency reference. The submillimeter output power is constant to within 4% over periods of hours. Mean frequency drifts of less than 2 parts in 100 million per minute were measured by mixing with very high harmonics of an X-band synthesizer in a planar Schottky diode.

Koepf, G. A.↗

Submillimeter heterodyne detection of interstellar carbon monoxide at 434 micrometers

Laser heterodyne observations of submillimeter emissions from carbon monoxide in the Orion molecular cloud are reported. High frequency and spatial resolution observations were made at the NASA Infrared Telescope Facility on Mauna Kea by the use of an optically pumped laser local oscillator and quasi-optical Schottky diode mixer for heterodyne detection of the J = 6 - 5 rotational transition of CO at 434 microns. Spectral analysis of the 434-micron emission indicates that the emitting gas is optically thin and is at a temperature above 180 K. Results thus demonstrate the potential contributions of ground-based high-resolution submillimeter astronomy to the study of active regions in interstellar molecular clouds.

Fetterman, H. R.↗

Super-Schottky mixer performance at 92 GHz

As part of a program to investigate the behavior of superconducting Schottky mixers at high frequencies, the mixing and video performance of several super-Schottky diodes (a 3-micron active diameter, and a doping concentration of 2 x 10 to the 19th per cu cm) have been tested at 92 GHz. At 92 GHz, video responsivities were typically 80 A/W (corrected for RF mismatch). Conversion loss (corrected for both RF and IF mismatches) was typically not less than 18 dB. As expected, diode temperature was low (less than 5 K). Video responsivity and conversion loss were also measured at an RF frequency of 3.95 GHz. These data were used with the measured volt-ampere characteristics of the diodes to compare theoretical predictions of diode performance at 92 GHz, in both the video and mixing modes, with the high-frequency data

Dickman, R. L.↗

Optically pumped submillimeter-waves and applications

Rapid development of optically pumped lasers has shown the potential to be used as a source for a high resolution spectrometer. In this connection, a compact, stable FIR laser was designed, fabricated, and assembled, integrating both the pump laser and the FIR cavity in the same mechanical structure for its improved (both thermal and mechanical) stability and mobility. Performance of the mixer structure which was designed and constructed for the evaluation of the Schottky diodes was found to be satisfactory. The feasibility of generating tunable sideband for molecular spectroscopy studies was demonstrated.

Dutta, J. M.↗