Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A poly(dimethylsiloxane)-based device enabling time-lapse imaging with high spatial resolution

We have developed a regulator-free device that enables long-term incubation of mammalian cells for epi-fluorescence imaging, based on a concept that the size of sample to be gassed and heated is reduced to observation scale. A poly(dimethylsiloxane) block stamped on a coverslip works as a long-lasting supplier of CO{sub 2}-rich gas to adjust bicarbonate-containing medium in a tiny chamber at physiological pH, and an oil-immersion objective warms cells across the coverslip. A time-lapse imaging experiment using HeLa cells stably expressing fluorescent cell-cycle indicators showed that the cells in the chamber proliferated with normal cell-cycle period over 2 days.

60 APPLIED LIFE SCIENCES↗

Ultra-scale vehicle tracking in low spatial-resolution and low frame-rate overhead video

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery either in real-time or quickly on-demand is very desirable. With this ability we can begin to answer a number of interesting questions such as, what are normal traffic patterns in a particular region or where did that truck come from? There are many challenges associated with processing this type of data, some of which we will address in the paper. Wide-field image sequences are very large with many thousands of pixels on a side and are characterized by lower resolutions (e.g. worse than 0.5 meters/pixel) and lower frame rates (e.g. a few Hz or less). The objects in the scenery can vary in size, density, and contrast with respect to the background. At the same time the background scenery provides a number of clutter sources both man-made and natural. We describe our current implementation of an ultrascale capable multiple-vehicle tracking algorithm for overhead persistent surveillance imagery as well as discuss the tracking and timing performance of the currently implemented algorithm which is aimed at utilizing grayscale electrooptical image sequences alone for the track segment generation.

42 ENGINEERING↗

Laser Ablation-Capillary Absorption Spectroscopy: A novel approach for high throughput and increased spatial resolution measurements of δ 13 C in plant-soil systems

Spatial and temporal heterogeneity of nutrient exchange within the rhizosphere is a topic of increasing interest, although challenging to study due to limits in existing analytical capabilities. Here, we developed and demonstrated a new approach applying laser ablation sample introduction to capillary absorption spectroscopy (LA-CAS) to characterize carbon isotopic distribution within plant tissues, rhizosphere, and soil. We exposed switchgrass plants to 13 CO 2 to allow tracing of 13 C-labelled photosynthates within plant biomass and into the associated soil. The LA-CAS methods we describe leverage continuous measurements of a sample stream derived from laser ablation line scans (10-25 µm in width) over a sample surface which enables the user to produce an isotope map with a) higher data density or b) over larger spatial areas versus previously existing techniques. This versatility of LA-CAS is assessed through testing of a range of laser parameters (spot size, scan rates) on various materials (soil, plant biomass/tissues, and rhizosphere). Here, we demonstrate the ability of LA-CAS to provide near instantaneous $δ$ 13 C measurements over isotopically distinct surfaces to enable high spatially resolved mapping of 13 C-labelled material within the rhizosphere. Applying LA-CAS analysis to plant biomass, we observed higher $δ$ 13 C values concentrated within phloem structures, consistent with localized photosynthate transport. When mapping across the rhizosphere, 13 C-enriched soil was typically present within 5-10µm of root boundaries with a steep spatial increase in $δ$ 13 C when the scan approached the middle of the root. As with all LA approaches, care is required to ensure accurate results as phenomena linked to ablation, combustion, and isotopic measurement can impart artifacts if not carefully controlled. Still, taken as a whole, our demonstrations highlight the increased sample throughput, improved data density, and enhanced $δ$ 13 C capability of LA-CAS versus other LA techniques and emphasize the role this method can play in future plant and rhizosphere related studies.

59 BASIC BIOLOGICAL SCIENCES↗

EUV mask reflectivity measurements with micron-scale spatial resolution

The effort to produce defect-free mask blanks for EUV lithography relies on increasing the detection sensitivity of advanced mask inspection tools, operating at several wavelengths. We describe the unique measurement capabilities of a prototype actinic (EUV wavelength) microscope that is capable of detecting small defects and reflectivity changes that occur on the scale of microns to nanometers. Types of defects: (a) Buried Substrate Defects: particles & pits (causes amplitude and/or phase variations); (b) Surface Contamination (reduces reflectivity and (possibly) contrast); (c) Damage from Inspection and Use (reduces the reflectivity of the multilayer coating). This paper presents an overview of several topics where scanning actinic inspection makes a unique contribution to EUVL research. We describe the role of actinic scanning inspection in four cases: defect repair studies; observations of laser damage; after scanning electron microscopy; and native and programmed defects.

36 MATERIALS SCIENCE↗

Electron transfer and ionic displacements as the origin of the 2D electron gas at the LAO/STO interface: Direct measurements with atomic-column spatial resolution.

We present direct, atomic-column-resolved scanning transmission electron microscopy and electron energy loss measurements of atomic displacements and Ti valence in abrupt, conductive LAO/STO interfaces. We find that two distinct but interrelated mechanisms are responsible for screening the diverging electric potential in the LAO film: 1) charge injection in the interfacial Ti planes, and 2) dielectric relaxation in both LAO and STO through ionic displacements. The injected charge density decays over a length of nearly 3 unit cells within the STO substrate. The total injected charge is lower than predicted by pure electronic reconstruction. The origin of this discrepancy is attributed to cation and oxygen displacements, which we observe in both LAO and STO, and generate a polarization opposite to the intrinsic polarization of the LAO film. Our data attribute a minor role to oxygen vacancies and cation intermixing.

36 MATERIALS SCIENCE↗

EUV mask reflectivity measurements with micro-scale spatial resolution

The effort to produce defect-free mask blanks for EUV lithography relies on increasing the detection sensitivity of advanced mask inspection tools, operating at several wavelengths. They describe the unique measurement capabilities of a prototype actinic (EUV) wavelength microscope that is capable of detecting small defects and reflectivity changes that occur on the scale of microns to nanometers. The defects present in EUV masks can appear in many well-known forms: as particles that cause amplitude or phase variations in the reflected field; as surface contamination that reduces reflectivity and contrast; and as damage from inspection and use that reduces the reflectivity of the multilayer coating. This paper presents an overview of several topics where scanning actinic inspection makes a unique contribution to EUVL research. They describe the role of actinic scanning inspection in defect repair studies, observations of laser damage, actinic inspection following scanning electron microscopy, and the detection of both native and programmed defects.

36 MATERIALS SCIENCE↗

Investigation of the spatial resolution of an online dose verification device

Purpose: The aim of this work is to characterize a new online dose verification device, COMPASS transmission detector array (IBA Dosimetry, Schwarzenbruck, Germany). The array is composed of 1600 cylindrical ionization chambers of 3.8 mm diameter, separated by 6.5 mm center-to-center spacing, in a 40 x 40 arrangement. Methods: The line spread function (LSF) of a single ion chamber in the detector was measured with a narrow slit collimator for a 6 MV photon beam. The 0.25 x 10 mm{sup 2} slit was formed by two machined lead blocks. The LSF was obtained by laterally translating the detector in 0.25 mm steps underneath the slit over a range of 24 mm and taking a measurement at each step. This measurement was validated with Monte Carlo simulation using BEAMnrc and DOSXYZnrc. The presampling modulation transfer function (MTF), the Fourier transform of the line spread function, was determined and compared to calculated (Monte Carlo and analytical) MTFs. Two head-and-neck intensity modulated radiation therapy (IMRT) fields were measured using the device and were used to validate the LSF measurement. These fields were simulated with the BEAMnrc Monte Carlo model, and the Monte Carlo generated incident fluence was convolved with the 2D detector response function (derived from the measured LSF) to obtain calculated dose. The measured and calculated dose distributions were then quantitatively compared using {chi}-comparison criteria of 3% dose difference and 3 mm distance-to-agreement for in-field points (defined as those above the 10% maximum dose threshold). Results: The full width at half-maximum (FWHM) of the measured detector response for a single chamber is 4.3 mm, which is comparable to the chamber diameter of 3.8 mm. The pre-sampling MTF was calculated, and the resolution of one chamber was estimated as 0.25 lp/mm from the first zero crossing. For both examined IMRT fields, the {chi}-comparison between measured and calculated data show good agreement with 95.1% and 96.3% of in-field points below {chi} of 1.0 for fields 1 and 2, respectively (with an average {chi} of 0.29 for IMRT field 1 and 0.24 for IMRT field 2). Conclusions: The LSF for a new novel online detector has been measured at 6 MV using a narrow slit technique, and this measurement has been validated by Monte Carlo simulation. The detector response function derived from line spread function has been applied to recover measured IMRT fields. The results have shown that the device measures IMRT fields accurately within acceptable tolerance.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-G-207-03: High Spatial Resolution and High Sensitivity X-Ray Fluorescence Imaging

Last few years has witnessed the development of novel of X-ray imaging modalities, such as spectral CT, phase contrast CT, and X-ray acoustic/fluorescence/luminescence imaging. This symposium will present the recent advances of these emerging X-ray imaging modalities and update the attendees with knowledge in various related topics, including X-ray photon-counting detectors, X-ray physics underlying the emerging applications beyond the traditional X-ray imaging, image reconstruction for the novel modalities, characterization and evaluation of the systems, and their practical implications. In addition, the concept and practical aspects of X-ray activatable targeted nanoparticles for molecular X-ray imaging will be discussed in the context of X-ray fluorescence and luminescence CT. Learning Objectives: Present background knowledge of various emerging X-ray imaging techniques, such as spectral CT, phase contrast CT and X-ray fluorescence/luminescence CT. Discuss the practical need, technical aspects and current status of the emerging X-ray imaging modalities. Describe utility and future impact of the new generation of X-ray imaging applications.

60 APPLIED LIFE SCIENCES↗

Structural analysis of ultrafast extended x-ray absorption fine structure with subpicometer spatial resolution: Application to spin crossover complexes

We present a novel analysis of time-resolved extended x-ray absorption fine structure (EXAFS) spectra based on the fitting of the experimental transients obtained from optical pump/x-ray probe experiments. We apply it to the analysis of picosecond EXAFS data on aqueous [Fe{sup II}(bpy){sub 3}]{sup 2+}, which undergoes a light induced conversion from its low-spin (LS) ground state to the short-lived ({tau}{approx_equal}650 ps) excited high-spin (HS) state. A series of EXAFS spectra were simulated for a collection of possible HS structures from which the ground state fit spectrum was subtracted to generate transient difference absorption (TA) spectra. These are then compared with the experimental TA spectrum using a least-squares statistical analysis to derive the structural change. This approach reduces the number of required parameters by cancellation in the differences. It also delivers a unique solution for both the fractional population and the extracted excited state structure. We thus obtain a value of the Fe-N bond elongation in the HS state with subpicometer precision (0.203{+-}0.008 A)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MAPPING CO GAS IN THE GG TAURI A TRIPLE SYSTEM WITH 50 au SPATIAL RESOLUTION

We aim to unveil the observational imprint of physical mechanisms that govern planetary formation in the young, multiple system GG Tau A. We present ALMA observations of {sup 12}CO and {sup 13}CO 3–2 and 0.9 mm continuum emission with 0.″35 resolution. The {sup 12}CO 3–2 emission, found within the cavity of the circumternary dust ring (at radius <180 au) where no {sup 13}CO emission is detected, confirms the presence of CO gas near the circumstellar disk of GG Tau Aa. The outer disk and the recently detected hot spot lying at the outer edge of the dust ring are mapped both in {sup 12}CO and {sup 13}CO. The gas emission in the outer disk can be radially decomposed as a series of slightly overlapping Gaussian rings, suggesting the presence of unresolved gaps or dips. The dip closest to the disk center lies at a radius very close to the hot spot location at ∼250–260 au. The CO excitation conditions indicate that the outer disk remains in the shadow of the ring. The hot spot probably results from local heating processes. The two latter points reinforce the hypothesis that the hot spot is created by an embedded proto-planet shepherding the outer disk.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH SPATIAL RESOLUTION X-RAY SPECTROSCOPY OF THE IC 443 PULSAR WIND NEBULA AND ENVIRONS

Deep Chandra ACIS observations of the region around the putative pulsar, CXOU J061705.3+222127, in the supernova remnant (SNR) IC 443 reveal an ∼5″ radius ring-like structure surrounding the pulsar and a jet-like feature oriented roughly north–south across the ring and through the pulsar's location at 06{sup h}17{sup m}5.{sup s}200 + 22°21′27.″52 (J2000.0 coordinates). The observations further confirm that (1) the spectrum and flux of the central object are consistent with a rotation-powered pulsar, (2) the non-thermal spectrum and morphology of the surrounding nebula are consistent with a pulsar wind, and (3) the spectrum at greater distances is consistent with thermal emission from the SNR. The cometary shape of the nebula, suggesting motion toward the southwest, appears to be subsonic: There is no evidence either spectrally or morphologically for a bow shock or contact discontinuity; the nearly circular ring is not distorted by motion through the ambient medium; and the shape near the apex of the nebula is narrow. Comparing this observation with previous observations of the same target, we set a 99% confidence upper limit to the proper motion of CXOU J061705.3+222127 to be less than 44 mas yr{sup −1} (310 km s{sup −1} for a distance of 1.5 kpc), with the best-fit (but not statistically significant) projected direction toward the west.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH SPATIAL RESOLUTION IMAGING OF THERMAL EMISSION FROM DEBRIS DISKS

We have obtained subarcsecond mid-IR images of a sample of debris disks within 100 pc. For our sample of 19 A-type debris disk candidates chosen for their IR excess, we have resolved, for the first time, five sources plus the previously resolved disk around HD 141569. Two other sources in our sample have been ruled out as debris disks since the time of sample selection. Three of the six resolved sources have inferred radii of 1-4 AU (HD 38678, HD 71155, and HD 181869), and one source has an inferred radius {approx}10-30 AU (HD 141569). Among the resolved sources with detections of excess IR emission, HD 71155 appears to be comparable in size (r {approx} 2 AU) to the solar system's asteroid belt, thus joining {zeta} Lep (HD 38678, reported previously) to comprise the only two resolved sources of that class. Two additional sources (HD 95418 and HD 139006) show spatial extents that imply disk radii of {approx}1-3 AU, although the excess IR fluxes are not formally detected with better than 2{sigma} significance. For the unresolved sources, the upper limits on the maximum radii of mid-IR disk emission are in the range {approx}1-20 AU, four of which are comparable in radius to the asteroid belt. We have compared the global color temperatures of the dust to that expected for the dust in radiative equilibrium at the distances corresponding to the observed sizes or limits on the sizes. In most cases, the temperatures estimated via these two methods are comparable, and therefore, we see a generally consistent picture of the inferred morphology and the global mid-IR emission. Finally, while our sample size is not statistically significant, we note that the older sources (>200 Myr) host much warmer dust (T {approx}> 400 K) than younger sources (in the tens of Myr).

79 ASTRONOMY AND ASTROPHYSICS↗

High spatial resolution charge sensing of quantum Hall states

Charge distribution offers a unique fingerprint of important properties of electronic systems, including dielectric response, charge ordering, and charge fractionalization. Here, we develop an architecture for charge sensing in two-dimensional electronic systems in a strong magnetic field. We probe local change of the chemical potential in a proximitized detector layer using scanning tunneling microscopy, allowing us to infer the chemical potential and the charge profile in the sample. Our technique has both high energy (<0.3 meV) and spatial (<10 nm) resolution exceeding that of previous studies by an order of magnitude. We apply our technique to study the chemical potential of quantum Hall liquids in monolayer graphene under high magnetic fields and their responses to charge impurities. The chemical potential measurement provides a local probe of the thermodynamic gap of quantum Hall ferromagnets and fractional quantum Hall states. The screening charge profile reveals spatially oscillatory response of the quantum Hall liquids to charge impurities and is consistent with the composite Fermi liquid picture close to the half-filling. Our technique also paves the way to map moiré potentials, probe Wigner crystals, and investigate fractional charges in quantum Hall and Chern insulators.

charge sensing↗

Urban-Scale Processes in High-Spatial-Resolution Earth System Models

Cities and their associated urban areas have a much larger impact on the environment than their spatial footprint on the Earth's surface. This is undoubtedly true at local and regional scales, but also at global scales. At this time, more than half of the world's population lives in urban areas (80% in the United States), and the global proportion is projected to climb to 70% by 2050. Therefore, numerical models to study physics, chemistry, and biology affecting the Earth system at regional and global scales must represent the effects of urban areas on climate and the effects of a changing climate on urban areas. At the same time, it is essential to develop state of the art, simple and accurate urban models to better understand the relevant processes and also to address issues related to urban security against the spectra of chemical, biological and radiological (CBR) hazards. Towards bringing urban scientific communities together, a two-and-a-half-day international workshop was held at the Argonne National Laboratory (ANL) in the Chicago area on May 22-24, 2019. This workshop brought together more than 60 national and international experts to develop a roadmap for a better understanding of the issues associated with urban areas and at enhancing the capabilities of regional and global Earth System models (ESMs) in representing the atmospheric dynamics and chemistry, unique aspects of the biosphere and land use, and human dimensions of the urban environment.

54 ENVIRONMENTAL SCIENCES↗

Spatial resolution of the electrical conductance of ionic fluids using a Green-Kubo method

We present a Green-Kubo method to spatially resolve transport coefficients in compositionally heterogeneous mixtures. We develop the underlying theory based on well-known results from mixture theory, Irving-Kirkwood field estimation, and linear response theory. Then, using standard molecular dynamics techniques, we apply the methodology to representative systems. With a homogeneous salt water system, where the expectation of the distribution of conductivity is clear, we demonstrate the sensitivities of the method to system size, and other physical and algorithmic parameters. Then we present a simple model of an electrochemical double layer where we explore the resolution limit of the method. In this system, we observe significant anisotropy in the wall-normal vs. transverse ionic conductances, as well as near wall effects. Lastly, we discuss extensions and applications to more realistic systems such as batteries where detailed understanding of the transport properties in the vicinity of the electrodes is of technological importance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Examining Infrasound Propagation at High Spatial Resolution Using a Nodal Seismic Array

Infrasound—acoustic waves in the atmosphere below 20 Hz—is a useful monitoring tool. Topography and atmospheric structure strongly control infrasound propagation, and at common source–receiver distances neither of these effects can be ignored when quantitative source constraints are sought. Detailed spatial measurements of the infrasound wavefield would inform propagation models and improve source estimates. However, the “large-N” deployment strategy now well-known in seismology has not yet been realized for infrasound studies. Here, we use the 900-node seismic array from the 2014 Imaging Magma Under St. Helens (iMUSH) experiment as a proxy for a large-N infrasound network, by leveraging acoustic–seismic coupled arrivals. The active-source component of iMUSH consisted of 23 shallowly buried explosions around Mount Saint Helens volcano; these explosions produced epicentral infrasound recorded on the nodes. We find that the bulk presence of ground-coupled infrasound on the nodes is controlled by wind noise and source–receiver distance, with observed arrivals for eight explosions. Explosions with the most extensive coupling produce complex spatial waveform patterns across the array. These patterns are related to both topographic and atmospheric propagation effects, as well as spatially variable site (coupling) effects. We compare our observations to simple topographic diffraction and high-resolution wind advection models, and full-wave numerical simulations. We find strong spatial correlations between (a) coupled arrival strength and modeled topographic obstruction and (b) coupled arrival time and along-path winds. Our seismoacoustic analyses and results are applicable to other existing and future nodal seismic data sets and can expand the utility of such deployments.

58 GEOSCIENCES↗

An apparatus and method for directly measuring the depth-dependent gain and spatial resolution of turbid scintillators

Turbid (powder or columnar–structured) scintillators are widely used in indirect flat panel detectors (I–FPDs) for scientific, industrial, and medical radiography. Light diffusion and absorption within these scintillators is expected to cause depth–dependent variations in their x ray conversion gain and spatial blur. Furthermore, these variations degrade the detective quantum efficiency of I–FPDs at all spatial frequencies. Despite their importance, there are currently no established methods for directly measuring scintillator depth effects. This work develops the instrumentation and methods to achieve this capability.

47 OTHER INSTRUMENTATION↗