Measurements of Erosion Wear Volume Loss on Bare and Coated Polymer Matrix Composites

An investigation was conducted to examine the erosion behavior of uncoated and coated polymer matrix composite (PMC) specimens subjected to solid particle impingement using air jets. The PMCs were carbon-Kevlar (DuPont, Wilmington, DE) fiber-epoxy resin composites with a temperature capability up to 393 K (248 F). Tungsten carbide-cobalt (WC-Co) was the primary topcoat constituent. Bondcoats were applied to the PMC substrates to improve coating adhesion; then, erosion testing was performed at the University of Cincinnati. All erosion tests were conducted with Arizona road-dust (ARD), impinging at angles of 20 and 90 on both uncoated and two-layer coated PMCs at a velocity of 229 m/s and at a temperature of 366 K (200 F). ARD contains primarily 10-m aluminum oxide powders. Vertically scanning interference microscopy (noncontact, optical profilometry) was used to evaluate surface characteristics, such as erosion wear volume loss and depth, surface topography, and surface roughness. The results indicate that noncontact, optical interferometry can be used to make an accurate determination of the erosion wear volume loss of PMCs with multilayered structures while preserving the specimens. The two-layered (WC-Co topcoat and metal bondcoat) coatings on PMCs remarkably reduced the erosion volume loss by a factor of approximately 10. The tenfold increase in erosion resistance will contribute to longer PMC component lives, lower air friction, reduced related breakdowns, decreased maintenance costs, and increased PMC reliability. The decrease in the surface roughness of the coated vanes will lead to lower air friction and will subsequently reduce energy consumption. Eventually, the coatings could lead to overall economic savings.

Miyoshi, Kazuhisa↗

Solvari SR, Simplifying Residential Solar to 1 SKU, with Extended Testing

Accelerated weathering and material compatibility testing for polymeric and asphaltic materials. NLR will be testing the durability of the polymeric materials proposed for use in the supporting structures designed by TESCI solar. This will include the bare materials and coupons attached to asphalt shingles. The exposure will be in damp heat and separately heat, humidity and UV light, all followed by mechanical evaluation. Modification 1 is an extension of the first round of testing with both a continuation of some of the same testing and addition of new testing methods and materials. The testing of materials in the condition of A3 looking at mechanical durability will be continued looking at the materials used in the mounting brackets. We will be adding in testing of the silicone adhesive to the module and of the module itself. For the mounting brackets, testing will also be conducted at multiple temperatures and humidity levels to allow for extrapolation to the field.

14 SOLAR ENERGY↗

Plasma surface modification coupled with thermal and step-over distance effects on significant fracture improvement of adhesively-bonded metal-$\mathrm{CFRTP}$ dissimilar materials

Here, this work proposes an approach to improve the interfacial bonding between carbon-fiber-reinforced thermoplastic polymers (CFRTP) and thermoset adhesive by using the surface modification with the combination of air plasma, thermal, and step-over effects. Thanks to the proper heating which causes the exposure of carbon fibers on the CFRTP surface, both polymer matrix and these exposed carbon fibers can have improved bonding with adhesive due to air plasma treatment. By conducting the Double Cantilever Beam (DCB) tests performed on adhesively-bonded AA5052/CFRP-PA66 dissimilar joints, it was shown in this work that the average Mode I specific fracture energy can be improved up to about 180% compared to non-treated counterparts. The foregoing improvement can be further increased by considering the step-over distance of the surface treatment, which triggers the tortuous damage path in the failure process of adhesively-bonded structures. By manipulating this treatment parameter, often overlooked in the literature, and other parameters (i.e., treatment speed, nozzle tip-to-surface distance, etc.) investigated in this study, the average Mode I specific fracture energy of adhesively-bonded AA5052/CFRP-PA66 dissimilar joints can be improved reaching up to about 410% compared to non-treatment counterparts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of EA-934NA with 2.5 percent Cab-O-Sil

Currently, Hysol adhesive EA-934NA is used to bond the Field Joint Protection System on the Shuttle rocket motors at Kennedy Space Center. However, due to processing problems, an adhesive with a higher viscosity is needed to alleviate these difficulties. One possible solution is to add Cab-O-Sil to the current adhesive. The adhesive strength and bond strengths that can be obtained when 2.5 percent Cab-O-Sil is added to adhesive EA-934NA are examined and tested over a range of test temperatures from -20 to 300 F. Tensile adhesion button and lap shear specimens were bonded to D6AC steel and uniaxial tensile specimens (testing for strength, initial tangent modulus, elongation and Poisson's ratio) were prepared using Hysol adhesive EA-934NA with 2.5 percent Cab-O-Sil added. These specimens were tested at -20, 20, 75, 100, 125, 150, 200, 250, and 300 F, respectively. Additional tensile adhesion button specimens bonding Rust-Oleum primed and painted D6AC steel to itself and to cork using adhesive EA-934NA with 2.5 percent Cab-O-Sil added were tested at 20, 75, 125, 200, and 300 F, respectively. Results generally show decreasing strength values with increasing test temperatures. The bond strengths obtained using cork as a substrate were totally dependent on the cohesive strength of the cork.

Caldwell, Gordon A.↗

Neurobehavioral Effects Of Five-Ion GCRSim Exposure In Male And Female Mice

Exposure to space galactic cosmic radiation is a principal consideration of spaceflight missions, and with upcoming missions to the Moon and Mars, it is increasingly imperative to elucidate the detrimental effects of space travel beyond the lower Earth orbit. Additionally, with the first female astronaut to soon travel to the Moon and beyond lower Earth orbit, there is a strong need to understand the biological sex differences to adaptation to the deep space environment. While the effects of spaceflight on the nervous system are not fully known, studies in animal models have shown that exposure to ionizing radiation can cause neuronal damage and lead to downstream cognitive and behavioral deficits. Therefore, we investigated the neurobehavioral responses to space environment-like radiation exposure. Male and female 23–24-week-old mice (age-matched to average astronaut age) were exposed to 5, 15 and 50 cGy via Five-Ion Galactic Cosmic Ray Simulation at the NASA National Space Radiation Laboratory at Brookhaven National Laboratory. Both early (72hrs post exposure) and late (1-4 months post exposure) cognitive and behavioral deficits were investigated. In-cage behavior was analyzed as frequency/duration of digging, rearing, and grooming and nestlet building using a 5-stage Deacon score. Additionally, at NASA Ames, behavior tests included Catwalk (gait), Zero Maze (anxiety), Adhesive Removal (sensory motor), Novel Object Recognition and Barnes Maze (working memory). There were pronounced sex differences in both early and late time points. Females typically performed the tests better than males, specifically in nestlet building, gait and working memory, though males performed better at the sensory motor (adhesive removal) test. Dose effects were primarily observed at 50 cGy for both sexes, particularly with the Barnes Maze (working memory), where both males and females exposed to 50 cGy showed little to no improvement in test performance, though females again performed better than males. Currently, we are investigating the correlations between the observed behavior and cytokine levels in the plasma and brain. Future studies will continue to investigate cognitive consequences of galactic cosmic radiation in combination with other space-like environment stressors, including antigravity and social versus single housing.

Stephanie Puukila↗

Neurobehavioral Effects Of Five-Ion GCRSim Exposure In Male And Female Mice

Exposure to space galactic cosmic radiation is a principal consideration of spaceflight missions, and with upcoming missions to the Moon and Mars, it is increasingly imperative to elucidate the detrimental effects of space travel beyond the lower Earth orbit. Additionally, with the first female astronaut to soon travel to the Moon and beyond lower Earth orbit, there is a strong need to understand the biological sex differences to adaptation to the deep space environment. While the effects of spaceflight on the nervous system are not fully known, studies in animal models have shown that exposure to ionizing radiation can cause neuronal damage and lead to downstream cognitive and behavioral deficits. Therefore, we investigated the neurobehavioral responses to space environment-like radiation exposure. Male and female 23–24-week-old mice (age-matched to average astronaut age) were exposed to 5, 15 and 50 cGy via Five-Ion Galactic Cosmic Ray Simulation at the NASA National Space Radiation Laboratory at Brookhaven National Laboratory. Both early (72hrs post exposure) and late (1-4 months post exposure) cognitive and behavioral deficits were investigated. In-cage behavior was analyzed as frequency/duration of digging, rearing, and grooming and nestlet building using a 5-stage Deacon score. Additionally, at NASA Ames, behavior tests included Catwalk (gait), Zero Maze (anxiety), Adhesive Removal (sensory motor), Novel Object Recognition and Barnes Maze (working memory). There were pronounced sex differences in both early and late time points. Females typically performed the tests better than males, specifically in nestlet building, gait and working memory, though males performed better at the sensory motor (adhesive removal) test. Dose effects were primarily observed at 50 cGy for both sexes, particularly with the Barnes Maze (working memory), where both males and females exposed to 50 cGy showed little to no improvement in test performance, though females again performed better than males. Currently, we are investigating the correlations between the observed behavior and cytokine levels in the plasma and brain. Future studies will continue to investigate cognitive consequences of galactic cosmic radiation in combination with other space-like environment stressors, including antigravity and social versus single housing.

S. Puukila↗

Load-deflection tests and computer analyses of a high-precision adhesive-bonded antenna reflector panel

New adhesive-bonded panels are being investigated as a part of an effort to extend and upgrade the 64-m to a 70-m antenna network. Load-deflection tests were conducted on a sample high-precision adhesive-bonded panel for comparison with design criteria. Two computerized structural models were developed in order to predict the deformation patterns under different types of distributed and concentrated loadings. The main purpose was to obtain empirical stiffness factors for the slit beams and girders in the panel structure. With determination and use of the empirical stiffness factors, there is a good agreement between the theoretically predicted deflections and the test measurements. It was also found that the new bonded panels satisfy the stringent design specifications and surface tolerance bounds.

Chian, C. T.↗

Copoly(Imide Siloxane) Abhesive Materials with Varied Siloxane Oligomer Length

Incorporation of PDMS moieties into a polyimide matrix lowered the surface energy resulting in enhanced adhesive interactions. Polyimide siloxane materials were generated using amine-terminated PDMS oligomers of different lengths to study changes in surface migration behavior, phase segregation, mechanical, thermal, and optical properties. These materials were characterized using contact angle goniometry, tensile testing, and differential scanning calorimetry. The surface migration behavior of the PDMS component depended upon the siloxane molecular weight as indicated by distinct relationships between PDMS chain length and advancing water contact angles. Similar correlations were observed for percent elongation values obtained from tensile testing, while the addition of PDMS reduced the modulus. High fidelity topographical modification via laser ablation patterning further reduced the polyimide siloxane surface energy. Initial particulate adhesion testing experiments demonstrated that polyimide siloxane materials exhibited greater abhesive interactions relative to their respective homopolyimides.

Wohl, Christopher J.↗

Qualification of black electrically conductive paint

A paint having low electrical resistance has been developed. Using a low outgassing polyurethane resin, specific amounts of conductive carbon particles were added to produce paint compositions having a range of electrical resistance. Methods of testing for electrical resistance are discussed. The adhesion of these paints has been tested successfully over the temperature range from liquid nitrogen temperature up to 80 C (176 F).

Park, J. J.↗

Joint Test Report For Validation of Alternatives to Aliphatic Isocyanate Polyurethanes

National Aeronautics and Space Administration (NASA) and Air Force Space Command (AFSPC) have similar missions and therefore similar facilities and structures in similar environments. The standard practice for protecting metallic substrates in atmospheric environments is the application of an applied coating system. The most common topcoats used in coating systems are polyurethanes that contain isocyanates. Isocyanates are classified as potential human carcinogens and are known to cause cancer in animals. The primary objective of this effort was to demonstrate and validate alternatives to aliphatic isocyanate polyurethanes resulting in one or more isocyanate-free coatings qualified for use at AFSPC and NASA installations participating in this project. This joint Test Report (JTR) documents the results of the laboratory and field testing as well as any test modifications made during the execution of the testing. The technical stakeholders agreed upon test procedure modifications documented in this document. This JTR is made available as a reference for future pollution prevention endeavors by other NASA centers, the Department of Defense and commercial users to minimize duplication of effort. All coating system candidates were tested using approved NASA and AFSPC standard coating systems as experimental controls. This study looked at eight alternative coating systems and two control coating systems and was divided into Phase I Screening Tests, Phase II Tests, and Field Testing. The Phase I Screening Tests were preliminary tests performed on all the selected candidate coating systems. Candidate coating systems that did not meet the acceptance criteria of the screening tests were eliminated from further testing. Phase I Screening Tests included: Ease of Application, Surface Appearance, Dry-To-Touch (Sanding), Accelerated Storage Stability, Pot Life (Viscosity), Cure Time (Solvent Rubs), Cleanability, Knife Test, Tensile (pull-off) Adhesion, and X-Cut Adhesion by Wet Tape After a review of the Phase I test results, four of the alternative coating systems showed substandard performance in relation to the Control Systems and were eliminated from the Phase II testing. Due to the interest of stakeholders and time constraints, however, all eight alternatives were subjected to the following Phase II tests, along with field testing at Stennis Space Center (SSC), Mississippi: Hypergol Compatibility, Liquid Oxygen Compatibility, 18-Month Marine Exposure (Gloss Retention, Color Retention, Blistering, Visual Corrosion, Creepage from Scribe, Heat Adhesion), and Field Exposure (6- and 12-month Evaluation for Coating Condition, Color Retention, Gloss Retention). The remaining four alternative coating systems determined to be the best viable alternatives were carried on to Phase II testing that included: Removability, Repairability, Abrasion Resistance, Gravelometer, Fungus Resistance, Accelerated Weathering, Mandrel Bend Flexibility, and Cyclic Corrosion Resistance. Of the systems that continued to Phase II, three (3) alternative coating systems meet the performance requirements as identified by stakeholders. Two (2) other systems, that were not included in Phase II testing, performed well enough on the 18-Month Marine Exposure, the primary requirement for NASA technical standard NASA-STD-5008, Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment, that they were also considered to be successful candidates. In total, five (5) alternative coating systems were approved for inclusion in the NASA-STD- 5008 Qualified Products List (QPL). The standard is intended to provide a common framework for consistent practices across NASA and is often used by other entities. The standard's QPL does not connote endorsement of the products by NASA, but lists those products that have been tested and meet the requirements as specified.

Lewis, Pattie↗

Adhesion and tribological characteristics of modified polyurethane coating on composite substrate

In the present study, glass-epoxy composites were used as a substrate to study the performance of modified polyurethane coating. Two-layer coating (180–200 µm) wherein the epoxy primer as the first coat and polyurethane as the top coat was applied using an air-assisted spray gun to increase the service life of the composite. The analysis of coating was performed using gloss, contact angle, FTIR, TGA, tensile test and SEM. The bonding strength between coating and substrate was evaluated by cross-hatch cut, 180 deg peel strength and pull-off adhesion tests. Scratch, Taber abrasion and Pin-on-disc tests were also performed to evaluate the wear resistance. In addition, a rain erosion test was performed to check the stability of the coating. From the above tests, it is concluded that the applied coating well adhered to the composite substrate. The data generated from different tests can be used to estimate the service life of polymer composites and coatings.

Mushtaq, Mohammed↗

Sulfur Impurities and the Microstructure of Alumina Scales

The relationship between the microstructure of alumina scales, adhesion, and sulfur content was examined through a series of nickel alloys oxidized in 1100 to 1200 deg. C cyclic or isothermal exposures in air. In cyclic tests of undoped NiCrAl, adhesion was produced when the sulfur content was reduced, without any change in scale microstructure. Although interfacial voids were not observed in cyclic tests of NiCrAl, they were promoted by long-term isothermal exposures, by sulfur doping, and in most exposures of NiAl. Two single crystal superalloys, PWA 1480 and Rene' N5, were also tested, either in the as-received condition or after the sulfur content had been reduced to less than 1 ppmw by hydrogen annealing. The unannealed alloys always exhibited spalling to bare metal, but interfacial voids were not observed consistently. Desulfurized PWA 1480 and Rene' N5 exhibited remarkable adhesion and no voidage for either isothermal or cyclic exposures. The most consistent microstructural feature was that, for the cases where voids did form, the scale undersides exhibited corresponding areas with ridged oxide grain boundaries. Voids were not required for spallation nor were other microstructural features essential for adhesion. These observations are consistent with the model whereby scale spallation is controlled primarily by interfacial sulfur segregation and the consequent degradation of oxide-metal bonding.

Smialek, James L.↗

Electrical properties of adhesives used in hybrid microelectronic applications

This paper describes a test program conducted to determine the electrical properties of adhesives used in hybrid microelectronic applications and to develop test methods for measuring these properties. The electrical properties of transistor chips mounted with conductive adhesives are also measured, and the effect of long term storage at high temperature on these devices is determined.

Sergent, J. E.↗

High-temperature testing of glass/ceramic matrix composites

Recent advances in ceramic and other high-temperature composites have created a need for test methods that can be used at 1000 C and above. Present test methods usually require adhesively bonded tabs that cannot be used at high temperatures. This paper discusses some of the difficulties with high-temperature test development and describes several promising test methods. Stress-strain data are given for Nicalon ceramic fiber reinforced glass and glass-ceramic matrix composites tested in air at temperatures up to 1000 C.

Mandell, John F.↗

Cyclic debonding of adhesive joints

Bonded lap joints were manufactured and tested under static and fatigue loading. Specimens were designed to fail in the bondline, and all fatigue tests included monitoring the crack growth to failure. Test specimens included aluminum details joined by two different adhesives. Specimens also included titanium and boron-epoxy details joined by an epoxy laminating resin. Additonal program variables included bondline thickness, adherend and spice plate thickness, specimen width, and specimen fabrication procedure. Adhesive aging was found to be generally detrimental to the lives of most of the specimens bonded with one adhesive system. Adhesive material was found to have a major influence on debond rate. Co-cured titanium/boron-epoxy specimens were found to resist debonding better than specimens fabricated with a sequential cure. Splice plate thickness and test section width were found to have little effect on debond rate. The data also suggested the existence of an optimum bondline thickness.

Hoffman, D. J.↗

Adhesion between polymers and evaporated gold and nickel films

To obtain information on the adhesion between metal films and polymeric solids, the adhesion force was measured by means of a tensile pull test. It was found that the adhesion strengths between polymeric solids and gold films evaporated on polymer substrates were (1.11 + or - 0.53) multiplied by 10(6) N/M(2) on PTFE, about 5.49 multiplied by 10(6) N/m(2) on UHMWPE, and 6.54x10(6) on 6/6 nylon. The adhesion strengths for nickel films evaporated on PTFE, UHMWPE, and 6/6 nylon were found to be a factor of 1.7 higher than those for the gold coated PTFE, UHMWPE, and 6/6 nylon. To confirm quantitatively the effect of electron irradiation on the adhesion strength between a PTFE solid and metal films, a tensile pull test was performed on the irradiated PTFE specimens, which were prepared by evaporating nickel or gold on PTFE surfaces irradiated by 2-keV electrons for various times. After irradiation, the adhesion strength increased to (4.92 + or - 0.92)x10(6) N/m(2) for nickel coated PTFE and (1.82 + or - 0.48)x10(6) N/m(2) for gold coated PTFE. The improvement in adhesion for nickel is higher than that for gold.