Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evaluation of Enhanced Low Dose Rate Sensitivity in Discrete Bipolar Junction Transistors

We evaluate the low dose rate sensitivity in several families of discrete bipolar transistors across device parameter, quality assurance level, and irradiation bias configuration. The 2N2222 showed the most significant low dose rate sensitivity, with low dose rate enhancement factor of 3.91 after 100 krad(Si). The 2N2907 also showed critical degradation levels. The devices irradiated at 10 mrad(Si)/s exceeded specifications after 40 and 50 krad(Si) for the 2N2222 and 2N2907 devices, respectively.

Chen, Dakai↗

Probability Estimates of Solar Proton Doses During Periods of Low Sunspot Number for Short Duration Missions

In an earlier paper presented at ICES in 2015, we investigated solar particle event (SPE) radiation exposures (absorbed dose) to small, thinly-shielded spacecraft during a period when the monthly smoothed sunspot number (SSN) was less than 30. Although such months are generally considered "solar-quiet", SPEs observed during these months even include Ground Level Events, the most energetic type of SPE. In this paper, we add to previous study those SPEs that occurred in 1973-2015 when the SSN was greater than 30 but less than 50. Based on the observable energy range of the solar protons, we classify the event as GLEs, sub-GLEs, and sub-sub-GLEs, all of which are potential contributors to the radiation hazard. We use the spectra of these events to construct a probabilistic model of the absorbed dose due to solar protons when SSN < 50 at various confidence levels for various depths of shielding and for various mission durations. We provide plots and tables of solar proton-induced absorbed dose as functions of confidence level, shielding thickness, and mission-duration that will be useful to system designers.

Atwell, William↗

A Statistical Study of Solar Particle Events in Flux and Dose

The high-energy protons from solar energetic particle (SEP) events present a hazard to space systems: damage to science instruments/electronics/materials or to astronauts. A reliable estimate of the high-energy proton environment is critical to assure mission success. Important characteristics of an SEP event are fluence, peak flux, energy spectrum, time to reach the peak flux, time to reach peak dose, and properties of the cumulative dose profile after an event starts. All of these characteristics are important to understand in order to design space missions properly for both robotic and human missions. Because of the unpredictable and sporadic nature of SEP events, statistical models are often used to represent the SEP parameters described above. In a study by Jun et al. (2007), the statistics of event fluences, durations, and time intervals between events were investigated using the then available historical SEP dataset obtained from the instruments onboard the IMP-8 spacecraft. Since then, a more comprehensive SEP dataset based off of IMP-8 and GOES called Reference Data Set Version 2.0 (RDSv2.0) has become available covering the SEP events up to Year 2015 under a framework of the European Space Agency's (ESA's) Solar Energetic Particle Environment Modelling (SEPEM) project (Jiggens et al., 2018). The main objectives of this statistical study of SEP events are two-fold: First, the statistics of peak fluxes, event fluences, durations, and time intervals will be re-visited by using RDSv2.0; Second, the statistical analyses of flux and dose timing will be performed using the same dataset RDSv2.0. The results of this study will address the statistical properties of all key parameters for designing a spacecraft or a human mission where the SEP environment is an important consideration.

Whitman, K.↗

Low-Dose Caffeine Administration During Acute Sleep Deprivation Eliminates Visual Motion Processing Impairment, but Does Not Improve Saccadic Rate

Oculomotor tracking performance changes according to time awake. A constant routine (CR) study demonstrated that increasing time awake 1) reduces the precision of visual motion processing, 2) decreases steady-state closed-loop pursuit performance and 3) decreases peak saccadic velocity. We aimed to determine the contribution of homeostatic sleep pressure on these oculometric changes by administering low-dose caffeine over one night of sleep deprivation. Participants completed two weeks of at-home 8.5 hours sleep per day, followed by an approximately 24-hour laboratory CR in semi-recumbent posture under less than 4 lux of light. The visual tracking task was performed every two hours after waking and hourly overnight. Low-dose caffeine of 0.3 milligrams per kilogram was administered hourly during the biological night. Nine participants (5F) completed the study. Caffeine dosing: 1) prevented the impairment of visual motion processing, 2) reduced by approximately half the impairment of closed-loop pursuit performance (gain, minus 0.47 percent per hour, significance of slope change: p (probability) less than 0.006; proportion smooth, minus 0.35 percent per hour, p less than 0.005), and 3) had an insignificant (p less than 0.39) effect on the impairment of saccadic peak velocity (slope, minus 1.13 percent per hour; intercept, minus 0.62 percent per hour). These results suggest that visual motion processing and some proportion of closed-loop pursuit performance are impaired due to homeostatic mechanisms during sleep deprivation.

Sleep↗

Total Ionizing Dose Test of Silicon Switching Transistors JANTXV2N2222AUB

Semicoa's silicon switching transistors, JANTXV2N2222AUB was tested for total ionizing dose (TID) response beginning on November 4, 2019. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Campola, M.↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

Dose, LET, time and strain dependence of radiation-induced 53BP1 foci in 15 mouse strains ex vivo and associations to in vivo radiation susceptibility

We present a comparative analysis on the repair of radiation-induced DNA damage ex vivo in 15 strains of mice, including 5 inbred reference strains and 10 collaborative-cross strains, of both sexes. Non-immortalized primary skin fibroblasts derived from 76 mice were subjected to both low- and high-LET radiation (0.1, 1 and 4 Gy of X rays; 1.1 and 3 particles/100μm2 of 350 MeV/n 40Ar and 600 MeV/n 56Fe). Automated image quantification of 53BP1 radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET. Similarly to what we had previously reported for immortalized human cell lines [1], we observed a saturation of RIF number with dose at 4h post-irradiation, with more RIF/Gy for lower LET (X rays and 40Ar) compared to 56Fe. However at later time points (24h and above), the trend was inverted with more RIF/Gy for higher LET. Our data suggest that multiple DSBs cluster into RIF: as the linear density of DSBs increases with LET, so does the probability of having more DSBs per RIF, which makes it more difficult for cells to fully resolve high-LET-induced RIF, explaining the hypersensitivity to high-LET radiation despite a low number of RIF. Taking into account the amount of clustering at a given dose and LET, but also the kinetics of DNA damage repair, we introduced a novel mathematical formalism to evaluate the number of remaining RIF over time. We showed that the newly introduced kinetic metrics can be used as surrogate biomarkers for in vivo radiation toxicity, with potential applications in radiotherapy and human space exploration. In particular, we observed an association between the repairable fraction of RIF measured in vitro and survival levels of immune cells collected from irradiated mice. Moreover, the speed of DNA damage repair correlated with spontaneous cancer incidence data collected from the Mouse Tumor Biology database, suggesting a relationship between the efficiency of DSB repair after irradiation and cancer risk. In addition to the efficacy of repair and persistent RIF levels, even the amount of spontaneous foci without irradiation was shown to be strain dependent, indicating that these phenotypes are at least partially driven by genetics, and supporting their potential as indicators of individual radiation sensitivity. [1] Neumaier, T., et al., PNAS, 2012 (8) 109:443

Radiation, DNA damage, repair kinetics↗

The impact of hydrogen contamination on the Total Dose Response of Linear Bipolar Microcircuits

Recent enhanced low dose rate sensitivity (ELDRS) investigations carried out by RLP Research, Crane, Arizona State University (ASU), and Jet Propulsion Laboratory (JPL) have shown significant differences in the degradation of bipolar microcircuits with total dose in the presence of molecular hydrogen (H2) in packages. This has a significant impact on radiation hardness assurance and opens up opportunity to improve device performance. The objectives of this program are 1) to investigate and confirm the causal relationship between packaging recipes, hydrogen contamination, and total dose response of linear bipolar microcircuits; and 2) to develop a guideline that will take into account these effects at the radiation level for future NASA space missions. This program is geared to benefit all future NASA space missions using bipolar or BiCMOS linear devices.

McClure, Steve S.↗

Total Ionizing Dose Testing of the Analog Devices’ AD648 Dual Precision Operational Amplifier

The Analog Devices (ADI) AD648 was tested for total ionizing dose response at the Goddard Space Flight Center (GSFC) Radiation Effects Facility (REF) beginning 1 June 2011. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Alvin J Boutte↗

Considerations on Electrolytic Conductivity Measurement for Monitoring of Ionic Silver Biocide Dosing

NASA interest in ionic silver (Ag+) as a biocide for spacecraft potable water systems motivates the development of Ag+ concentration sensors to ensure nominal dosing. The electrolytic conductivity change of highly-purified potable water is linearly related to the concentration of chemically-dosed Ag+ and could serve as a useful proxy measurement, while the conductivity change during electrolytic dosing may be less so, depending on the influent water chemistry and electrolytic efficiency. Understanding and mitigating the potentially deleterious effects of Ag+ interaction with conductivity measurement systems requires investigation. Issues associated with traditional conductivity cells, which rely on wetted(typically metal or graphite) electrodes, and capacitively-coupled contactless conductivity detection (C4D) for this application are considered. Traditional conductivity cells may potentially be subject to significant excitation-induced or auto-galvanic reduction of Ag+. These may result in Ag+ depletion or electrode fouling and associated measurement error. Proper selection of electrode material, excitation parameters, and cell geometry may limit such effects. C4D uses electrodes placed outside an inert, insulating material, with dielectric polarization enabling the production of an electric field and resultant current across the analyte solution. This approach could potentially mitigate problems with Ag+ depletion and fouling by eliminating the possibility of auto-galvanic deposition and reducing the Faradaic current density. However, it is necessary to confirm C4D performance at very low conductivity levels and to determine if long-term operation produces conductive deposits, which could result in measurement error. A commercial C4D system with 1/16” (1.59 mm)outer diameter flow tubing and claimed performance in the conductivity range appropriate for this application was identified, and its sensitivity in the upper parts of this range was confirmed in a preliminary experiment. A concept for a C4D detector that could allow for full rate flow-through using planar electrodes and thin-film dielectric layers is discussed.

silver↗

Split-Step Simulations to Assess the Effects of Atmospheric Boundary Layer Turbulence on the Dose Variability of N-Waves and Shaped Booms

The effects of atmospheric boundary layer turbulence on the loudness variability of a sonic boom N-wave and shaped boom are examined with split-step simulations. The shaped boom is representative of a design iteration of the NASA X-59 aircraft. Inhomogeneous atmospheric boundary layer turbulence is generated in the computational domain by a Fourier synthesis method. The N-wave and shaped boom are propagated through turbulent fields representing eight different convection levels measured at the NASA Kennedy Space Center and the NASA Armstrong Flight Research Center. Probability density functions of the formation of caustic regions along the propagation direction are computed from the N-wave results, and a parameter to collapse the caustic PDFs that accounts for both fluctuation intensities and length scales is proposed. Statistical results concerning loudness metric variability are presented, and the standard deviations of several metrics are shown to collapse across different convection levels of turbulence for small nondimensional propagation distances. The loudness metric distributions are observed to be well approximated by a normal distribution for a given range of propagation distances, and become increasingly skewed as distance increases. A model function for the dose variability is proposed, and the function parameters are found to be related to the convection level of the turbulence. The model for the dose variability distribution is compared to simulation data that were not used to find the regression parameters of the model. At several nondimensional propagation distances, agreement is observed between the model and the simulation data. These results indicate that the model may be suitable for providing quick estimates of noise dose variability in the primary carpet region across a wide range of atmospheric boundary layer conditions.

Sonic boom↗

Differential Saccade-Pursuit Coordination Under Sleep Loss and Low-Dose Alcohol

Introduction: Ocular tracking of a moving object requires tight coordination between smooth pursuit and saccadic eye movements. Normally, pursuit drives gaze velocity to closely match target velocity, with residual position offsets corrected by catch-up saccades. However, how/if common stressors affect this coordination is largely unknown. This study seeks to elucidate the effects of acute and chronic sleep loss, and low-dose alcohol, on saccade-pursuit coordination, as well as that of caffeine. Methods: We used an ocular tracking paradigm to assess three metrics of tracking (pursuit gain, saccade rate, saccade amplitude) and to compute “ground lost” (from reductions in steady-state pursuit gain) and “ground recouped” (from increases in steady-state saccade rate and/or amplitude). We emphasize that these are measures of relative changes in positional offsets, and not absolute offset from the fovea. Results: Under low-dose alcohol and acute sleep loss, ground lost was similarly large. However, under the former, it was nearly completely recouped by saccades, whereas under the latter, compensation was at best partial. Under chronic sleep restriction and acute sleep loss with a caffeine countermeasure, the pursuit deficit was dramatically smaller, yet saccadic behavior remained altered from baseline. In particular, saccadic rate remained significantly elevated, despite the fact that ground lost was minimal. Discussion: This constellation of findings demonstrates differential impacts on saccade-pursuit coordination with low-dose alcohol impacting only pursuit, likely through extrastriate cortical pathways, while acute sleep loss not only disrupts pursuit but also undermines saccadic compensation, likely through midbrain/brainstem pathways. Furthermore, while chronic sleep loss and caffeine-mitigated acute sleep loss show little residual pursuit deficit, consistent with uncompromised cortical visual processing, they nonetheless show an elevated saccade rate, suggesting residual midbrain and/or brainstem impacts.

smooth pursuit↗

PE99155 Point-Of-Load Buck Regulator Total Ionizing Dose Test Report

Teledyne’s PE99155 point-of-load buck regulator was tested to evaluate an applicationspecific question about the start-up behavior of the device. This test determined if accumulated total ionizing dose (TID) affected any start-up voltage transient characteristics. Testing was based on pass/fail criterial for the magnitude of the output voltage to ensure the safety of downstream electronics. Two sets of radiation tests were performed. The first group of PE99155s used a high dose rate (HDR) irradiation to 25 krad(Si). A second group of PE99155s used high dose rate irradiation to 30 krad(Si).

TID↗

Total Ionizing Dose Test Report Microchip JANTXV2N6284 NPN Darlington Power Si Transistor

This study was undertaken to determine the effects of total ionizing dose (TID) on the JANTXV2N6284 NPN Darlington power bipolar junction transistor (BJT). The device was parametrically characterized prior to, at each incremental dose step, and after irradiation. Testing was at a low-dose rate using the NASA GSFC Radiation Effects Facility (REF).

Kaitlyn L Ryder↗

Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator

The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).

enhanced low dose rate sensitivity (ELDRS↗

Avalanche ASV016204 (Pre-Production Samples) 40nm MRAM Total Ionizing Dose Test Report

The purpose of this test was to characterize the Avalanche Technology ASV016204’s total dose response. In the test, the device was exposed to high dose rate (HDR) irradiations using gamma radiation. Device functionality (in terms of memory cell upsets and read/write ability) as well as power supply currents during various modes of operations were recorded.

Total Ionizing Dose (TID)↗

Updated Noise Dose Range of NASA’s X-59 Aircraft Estimated from Propagation Simulations

A follow-on study to Doebler and Loubeau, “The noise dose range of the X-59 estimated from propagation simulations,” JASA 150(4), A208 (2021); doi:10.1121/10.0008134 is described. In the previous work, propagation simulations of NASA’s X-59 sonic thump were conducted using two near-field pressure solutions from NASA’s Cart3D computational fluid dynamics (CFD) code. The near-fields were propagated through realistic atmospheric profiles from the Climate Forecast System Version 2 database across the USA, and Perceived Level statistics of the thumps were presented. The current work repeats the previous analyses, instead using near-field CFD solutions from NASA’s Fully Unstructured Navier-Stokes (FUN3D) code for the same aircraft conditions (Mach 1.4 at 53,200 feet and Mach 1.3 at 43,000 feet), which achieve the minimum and maximum cruise loudness. NASA and contractors in the X-59 development and community noise testing project mutually agreed upon using FUN3D for generating near-field pressures. Sonic thump loudness statistics using the FUN3D near-fields are similar to those of Cart3D. The min loudness condition is about 1 dB (PL) greater when using the FUN3D solution, and the max loudness condition results are nearly identical. Understanding the X-59’s dose range for various flight and atmospheric conditions is important for planning X-59 community noise surveys.

X-59↗