Search NASASearch

SEARCH · Search NASA

Results for “high temperature superfluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

668 records · Page 14

Surprisingly Enriched CO and CH4 in Halley-type Comet 13P/Olbers: Clues to Its Interstellar Heritage

The native ice composition of Halley-type Comet 13P/Olbers (hereafter 13P) was measured post-perihelion, on UT 2024 August 16 using iSHELL, the 1–5 μm cross-dispersed, high-resolution facility spectrograph at the NASA InfraRed Telescope Facility. At that time, the heliocentric distance (Rh) of 13P was 1.37 au and the geocentric distance (Δ) was 1.99 au. Using a slit that delivered spectral resolving power RP λ/Δλ 4.5 × 104, two instrument settings targeted rovibrational emissions of seven parent molecules released into the coma through sublimation of ices in the nucleus. These settings provided broad and contiguous or nearly contiguous spectral coverage, one simultaneously measuring H2O, CO, and OCS, and the other simultaneously measuring CH4, C2H6, CH3OH, and H2CO. Meaningful abundances were obtained for all seven species. Our study revealed substantial enrichments of CO and CH4, the two most volatile species systematically targeted at IR wavelengths in comets. Relative to their respective mean abundance ratios among measured comets from the Oort cloud reservoir, CO in 13P was enriched by a factor of about six and CH4 was enriched by a factor of about three. Together with near-average abundances measured for CH3OH and C2H6, this suggests large endowments of CO and CH4 on interstellar grains, yet it could indicate inhibited surface chemistry on the pre-cometary grains subsequently contained in the nucleus or 13P. Assuming that this represents the primordial composition of 13P, it could reflect very low temperatures in its natal environment (∼10 K or lower).

Michael A Disanti

On the Stability Analysis of Astrophysical Cooling Functions

To model the temperature evolution of optically thin astrophysical environments at MHD scales, radiative and collisional cooling rates are typically either pretabulated or fit into a functional form and then input into MHD codes as a radiative loss function. Thermal balance requires estimates of the analogous heating rates, which are harder to calculate, and due to uncertainties in the underlying dissipative heating processes these rates are often simply parameterized. The resulting net cooling function defines an equilibrium curve that varies with density and temperature. Such cooling functions can make the gas prone to thermal instability (TI), which will cause departures from equilibrium. There has been no systematic study of thermally unstable parameter space for nonequilibrium states. Motivated by our recent finding that there is a related linear instability, catastrophic cooling instability, that can dominate over TI, here we carry out such a study. We show that Balbus instability criteria for TI can be used to define a critical cooling rate, Λc, that permits a nonequilibrium analysis of cooling functions through the mapping of TI zones. We furthermore illustrate how thermal conduction modifies the shape of TI zones. Upon applying a Λc-based stability analysis to coronal loop simulations, we find that loops undergoing periodic episodes of coronal rain formation are linearly unstable to catastrophic cooling instability, while TI is stabilized by thermal conduction.

Amanda Stricklan

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe

EMU battery/SMM power tool characterization study

The power tool which will be used to replace the attitude control system in the SMM spacecraft was modified to operate from a self contained battery. The extravehicular mobility unit (EMU) battery was tested for the power tool application. The results are that the EMU battery is capable of operating the power tool within the pulse current range of 2.0 to 15.0 amperes and battery temperature range of -10 to 40 degrees Celsius.

Palandati, C.

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems

Suppression of Marangoni Convection in Float Zones

The basic purpose of this program is to demonstrate by means of an Earth-based 1-g experiment that the undesirable Marangoni (surface tension) convection can be suppressed or significantly reduced by means of gas jets directed tangentially to the free surface of the liquid in a float zone. These jets will establish the tangential shear stress field over the surface which must be adjusted to equal the counter-stress resultant of the Marangoni shear stress which causes the convection. For proposed materials processing in space (o-g), particularly of important, highly reactive semiconductor materials, e.g., silicon, microgravity will virtually eliminate the unwanted thermal-buoyancy convection in the liquid silicon, but will have no effect in reducing the Marangoni convection. Unless this can be sufficiently suppressed by other means, there may be no significant advantages to the proposed space processing of reactive semiconductors. Although some inert gas such as argon must be used for the corrosive liquid silicon, the Earth-based experiment uses air jets and various transparent oils, since the basic principle involved is the same. The first float zone is enclosed in a very small rectangular box with a quasi-planar free surface. Stable Marangoni convection has been achieved and velocities measured photographically. The air jet system with variable velocity and temperature is under construction. Three independent parameters must be optimized to attain maximum suppression: the gas velocity, angle of attack, and gas temperature.

Robert F Dressler

Polymer Composite Material Testing for a Cryotank Application

Composite cryotanks will play a key role in enabling the next generation of efficient aircraft. Carbon fiber reinforced polymer (CFRP) composites have the benefits of reduced weight and potentially higher structural strength compared to traditional metallic fuel tanks. A material screening study was conducted to inform material selection for liquid hydrogen (LH2) fuel storage. Three composite materials were considered because of their aerospace grade toughness, strength, and existing data to compare against. These materials were a thermoplastic low-melt polyaryletherketone (LM-PAEK)/carbon fiber (CF), thermoset/CF, and hybrid thermoset/thermoplastic polyurethane (TPU) veil/CF composite. Mechanical screening tests included tension, compression, in-plane shear (IPS), and tensile-tensile fatigue (TTF). Each material was tested at both a baseline (no liquid nitrogen/LN2 cycling) and 100 LN2-cycled conditions to determine the knockdown factor, if any, of each material when exposed to environmental loading effects in a cryotank. Results show minimal effects of the LN2-cycling compared against baseline values. The three materials behaved similarly in tension; however, the thermoplastic/CF had the highest IPS toughness. The hybrid thermoset/TPU/CF composite had the lowest IPS strength, compressive strength, and toughness. LN2-cycling had minimal effects on tensile-tensile fatigue performance of the thermoplastic/CF material. Mechanical data was captured to guide material down selection for future commercially viable hydrogen aircraft design. In its current state, there does not exist a consolidated, publicly available database for CFRP composite material performance data at cryogenic temperatures. The next step in this work is to test the thermoplastic and thermoset CFRP composites, as well as the neat resins, at LH2 relevant temperature (20 K) to capture this crucial material property data. These results are essential to inform cryotank design and modeling efforts. The process to start this next round of testing has begun. Planned mechanical tests include toughness (single-edge notched beam), tension (unidirectional and quasi-isotropic), thermal expansion, and thermal conductivity. Some tests will also be conducted at an intermediate temperature of 111 K relevant to liquid natural gas (LNG), another attractive fuel choice. The ultimate goal is to manufacture a sub-scale cryotank part that can pass relevant burst, fatigue, permeation, and thermal cycling tests. This work is a part of NASA’s Commercially viable Hydrogen Aircraft for Robust Growth in Efficiency (CHARGE) Project under the larger NASA Subsonic Vehicle Technologies and Tools (SVTT) Project.

composites

Performance of the Lester battery charger in electric vehicles

Tests are performed on an improved battery charger. The primary purpose of the testing is to develop test methodologies for battery charger evaluation. Tests are developed to characterize the charger in terms of its charge algorithm and to assess the effects of battery initial state of charge and temperature on charger and battery efficiency. Tests show this charger to be a considerable improvement in the state of the art for electric vehicle chargers.

Vivian, H. C.

Modeling a Li/SOCl2 battery for design purposes

A generalized code applicable to many different electrochemical systems and geometric designs is discussed. The code is to be set up so that physical property data such as thermal conductivity, viscosity, density, and configuration (e.g. physical dimensions) are the input data. Thus, by changing these parameters many different battery configurations can be handled. The outputs, as a function of time and space, are voltage, current, temperature, pressure, velocity, and species concentration.

Ernst, D. W.

Behavior of HfB2-SiC Materials in Simulated Re-Entry Environments

The objectives of this research are to: 1) Investigate the oxidation/ablation behavior of HfB2/SiC materials in simulated re-entry environments; 2) Use the arc jet test results to define appropriate use environments for these materials for use in vehicle design. The parameters to be investigated include: surface temperature, stagnation pressure, duration, number of cycles, and thermal stresses.

Don Ellerby

EMU Battery/module Service Tool Characterization Study

The power tool which will be used to replace the attitude control system in the SMM spacecraft is being modified to operate from a self contained battery. The extravehicular mobility unit (EMU) battery, a silver zinc battery, was tested for the power tool application. The results obtained during show the EMU battery is capable of operating the power tool within the pulse current range of 2.0 to 15.0 amperes and battery temperature range of -10 to 40 degrees Celsius.

Palandati, C. F.

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

Update of the IUE battery in-flight performance

The in-flight performance data of two 17-cell, 6-ampere-hour nickel cadmium spacecraft batteries are presented covering 22 months of operation. Fluctuations in the battery voltage and the battery temperature are presented for spacecraft movement throughout a beta range of 0 to 130 deg. The battery discharge voltages during the peak eclipse seasons, daily seasons, and daily eclipse periods are noted. Finally, the spacecraft data are compared to data from a 6-ampere-hour test pack and test flight data.

Tiller, S. E.

Transit Thermal Control Design for Galileo Entry Probe for Planet Jupiter

A totally passive design was completed for the thermal control of the Galileo entry probe during its transit to the planet Jupiter. The design utilizes radio isotope heater units, multilayer insulation blankets and a thermal radiator in conjunction with a design conductance support structure to achieve both the required storage and critical initial planet atmosphere entry temperatures. The probe transit thermal design was completed and verified based on thermal vacuum testing of a prototype probe thermal test model.

George C. Haverly

Battery Definition for the Mars Environmental Survey Mission (MESUR) Pathfinder

Silver-zinc (Ag-Zn) battery technology has been baselined as the energy storage system for the MESUR mission. The mission profile will require the operation of this battery in a manner not usually seen for this technology. In particular, the combination of storage time followed by multiple cycles as a function of fluctuating temperatures and charge/discharge rates, and limited available time for charging has not been previously demonstrated.

Ag-Zn

Prediction of prompt NO(x) in hydrocarbon air flames

The gas turbine industry is directing particular attention to very low NOx combustors, whether for aircraft or land based CCGT systems. These low NOx combustors frequently use liquid fuels or natural gas burning under very lean premixed conditions with air or under rich-lean conditions, although only the first case is studied here. In land based systems, diluted steam or nitrogen are sometimes injected into the combustion chambers to reduce flame temperature. The NOx emissions from such systems are the product of three chemical mechanisms which are interrelated: the hydrocarbon prompt NO, the thermal NO (extended Zeldovich mechanism), and the nitrous oxide route to NO. Formation of NO2 from NO also occurs, as well as emission of carbon monoxide and unburnt hydrocarbons. When the fuel-oxidant proportion decreases towards leaner conditions, flame temperatures are lowered, resulting in the total NO being reduced and the thermal-NO contribution greatly diminished to the benefit of the remaining two mechanisms of NO formation. While knowledge of the elementary reactions and their chemical kinetics concerning methane and simple hydrocarbons combustion has existed for a number of years, its use for computer modeling is limited to simple flow dynamics configurations. Nevertheless, understanding of such combusting flows under a wide range of experimental conditions allows for analogies or speculations with more complex actual systems. Such understanding can be achieved by means of one dimensional laminar premixed flame modeling, with a full chemical mechanism which incorporates the three routes of NO formation. Complementary to this understanding is the modeling of the actual combustion system using a full description of the fluid dynamics coupled with a reduced chemical scheme, which is then compared against the first model. The objective of this investigation is to evaluate the relative importance of the three mechanisms of NO formation in lean premixed methane-air combustion with increasing pressure using the one dimensional plug flow package PREMIX, and to test the validity of a three dimensional model with a global chemical mechanism against the one dimensional model in the atmospheric pressure case. Methane is chosen because it is the only mechanism which is reasonably well known and is a good guide to the behavior of other hydrocarbons. The mixture ratio chosen is richer than that in lean gas turbines, but the combustion of this mixture with the low preheat gives realistic gas turbine final flame temperatures. Conditions of NO2 formation are also analyzed in the one dimensional model and results extrapolated to the case of gas turbines.

Valerie Dupont

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)