Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Transonic flow about a two-dimensional airfoil inviscid and turbulent flow properties.

Flow-field measurements are presented for a symmetrical NACA 64A010 airfoil section at transonic conditions. Measurements were obtained for three angles of attack with the free-stream Mach number fixed at 0.8. The cases studied included a weak shock wave/boundary layer interaction, an interaction of medium strength with mild separation, and an interaction of sufficient strength to produce a shock-induced stall situation. Two nonintrusive optical techniques, laser velocimetry and holographic interferometry, were used to characterize the flows. The results include Mach number contours and flow angle distributions in the inviscid flow regions, and turbulent flow properties, including the turbulent Reynolds stresses, of the upper surface viscous layers, and of the near-wake. The turbulent flow measurements reveal that the turbulence fluctuations attain equilibrium with the local mean flow much faster than previously expected.

Johnson, D. A.↗

Status of holographic interferometry at Wright Patterson Air Force Base

At Wright Patterson AFB, holographic interferometry has been used for nearly 15 years in a variety of supersonic and hypersonic wind tunnels. Specifically, holographic interferometry was used to study boundary layers, shock boundary layer interaction, and general flow diagnostics. Although a considerable amount of quantitative work was done, the difficulty of reducing data severely restricted this. In the future, it is of interest to use holographic interferometry in conjunction with laser Doppler velocimetry to do more complete diagnostics. Also, there is an interest to do particle field diagnostics in the combustion research facility. Finally, there are efforts in nondestructive testing where automated fringe readout and analysis would be extremely helpful.

Seibert, George↗

On principles, methods and recent advances in studies towards a GPS-based control system for geodesy and geodynamics

Although Very Long Baseline Interferometry (VLBI) and Satellite Laser Ranging (SLR) are becoming increasingly important tools for geodynamic studies, their future role may well be fulfilled by using alternative techniques such as those utilizing the signals from the Global Positioning System (GPS). GPS, without the full implementation of the system, already offers a favorable combination of cost and accuracy and has consistently demonstrated the capability to provide high precision densification control in the regional and local areas of the VLBI and SLR networks. This report reviews VLBI and SLR vis-a-vis GPS and outlines the capabilities and limitations of each technique and how their complementary application can be of benefit to geodetic and geodynamic operations. It demonstrates, albeit with a limited data set, that dual-frequency GPS observations and interferometric type analysis techniques make possible the modelling of the GPS orbits for several days with an accuracy of a few meters. The use of VLBI or SLR sites as fiducial stations together with refinements in the orbit determination procedures can greatly reduce the systematic errors in the GPS satellite orbits used to compute the positions of non-fiducial locations. In general, repeatability and comparison with VLBI of the GPS determined locations are of the order of between 2 parts in 10 to the 7th power and 5 parts in 10 to the 8th power for baseline lengths less than 2000 km. This report is mainly a synthesis of problems, assumptions, methods and recent advances in the studies towards the establishment of a GPS-based system for geodesy and geodynamics and is one phase in the continuing effort for the development of such a system. To some, including the author, it seems reasonable to expect within the next few years that more evidence will show GPS to be as a powerful and reliable a tool as mobile VLBI and SLR are today, but largely more economical.

Delikaraoglou, Demitris↗

A determination of the radio-planetary frame tie and the DSN tracking station locations

The orientation of the reference frame of radio source catalogs relative to that of planetary ephemerides is uncertain by 30 mas (150 nrad). At this level of uncertainty this orientation offset, or 'frame tie', can be a major systematic error source for interplanetary spacecraft orbit determination. This work presents a method of determining the radio-planetary frame tie from a comparison of Very Long Baseline Interferometry (VLBI) and Lunar Laser Ranging (LLR) station coordinate and earth orientation parameter estimates. Preliminary results are presented which indicate that accuracies of 5 mas or better may be achieved with this method. An important by-product of this method of frame tie determination is a set of Deep Space Network (DSN) station locations with 10 cm per component accuracy. This station set is in a geocentric coordinate system with known orientation relative to the radio and planetary frames.

Finger, Mark H.↗

A determination of the radio-planetary frame tie from comparison of Earth orientation parameters

The orientation of the reference frame of radio source catalogs relative to that of planetary ephemerides, or 'frame tie,' can be a major systematic error source for interplanetary spacecraft orbit determination. This work presents a method of determining the radio-planetary frame tie from a comparison of very long baseline interferometry (VLBI) and lunar laser ranging (LLR) station coordinate and earth orientation parameter estimates. A frame tie result is presented with an accuracy of 25 nrad.

Finger, M. H.↗

Sub-daily resolution of earth rotation variations with Global Positioning System measurements

Data from a worldwide Global Positioning System (GPS) tracking experiment have been used to determine variations in earth rotation (UT1-UTC) over a time period of three weeks. Kalman filtering and smoothing enabled changes in UT1-UTC over intervals of 2 to 24 hrs to be detected with the GPS data. Internal consistency checks and comparisons with other solutions from very long baseline interferometry (VLBI) and satellite laser ranging (SLR) indicate that the GPS UT1-UTC estimates are accurate to about 2 cm. Comparison of GPS-estimated variations in UT1-UTC with 2-hr time resolution over 4 days with predicted variations computed from diurnal and semidiurnal oceanic tidal contributions strongly suggests that the observed periodic sub-daily variations of about 0.1 msec are largely of tidal origin.

Lichten, Stephen M.↗

Interlaminar shear test method development for long term durability testing of composites

The high speed civil transport is a commercial aircraft that is expected to carry 300 passengers at Mach 2.4 over a range of more than 6000 nautical miles. With the existing commercial structural material technology (i.e., aluminum) the performance characteristics of the high speed civil transport would not be realized. Therefore there has been a concerted effort in the development of light weight materials capable of withstanding elevated temperatures for long duration. Thermoplastic composite materials are such candidate materials and the understanding of how these materials perform over the long term under harsh environments is essential to safe and effective design. The matrix dominated properties of thermoplastic composites are most affected by both time and temperature. There is currently an effort to perform short term testing to predict long term behavior of in-plane mechanical properties E22 (transverse modulus of elasticity) and G12 (shear modulus). Out-of-plane properties such as E33, G13, and G23 are inherently more difficult to characterize. This is especially true for the out-of-plane shear modulus G23 and hence there is no existing acceptable standard test method. Since G23 is the most matrix dominated property, it is essential that a test method be developed. A shear test methodology is developed to do just that. The test method, called the double notched specimen, along with the previously developed shear gage was tested at room temperature. Mechanical testing confirmed the attributes of the methodology. A finite element parametric study was conducted for specimen optimization. Moire interferometry, a high sensitivity laser optical method, was used for full-field analysis of the specimen. From this work, material parameters will be determined and thus enable the prediction of long term material behavior of laminates subjected to general loading states.

Ifju, Peter G.↗

Electric Field Induced Interfacial Instabilities

The study of the interface in a charge-free, nonpolar, critical and near-critical binary fluid in the presence of an externally applied electric field is presented. At sufficiently large fields, the interface between the two phases of the binary fluid should become unstable and exhibit an undulation with a predefined wavelength on the order of the capillary length. As the critical point is approached, this wavelength is reduced, potentially approaching length-scales such as the correlation length or critical nucleation radius. At this point the critical properties of the system may be affected. In zero gravity, the interface is unstable at all long wavelengths in the presence of a field applied across it. It is conjectured that this will cause the binary fluid to break up into domains small enough to be outside the instability condition. The resulting pattern formation, and the effects on the critical properties as the domains approach the correlation length are of acute interest. With direct observation, laser light scattering, and interferometry, the phenomena can be probed to gain further understanding of interfacial instabilities and the pattern formation which results, and dimensional crossover in critical systems as the critical fluctuations in a particular direction are suppressed by external forces.

Kusner, Robert E.↗

Transonic Flow Past a Symmetrical Airfoil at High Angle of Attack

The results of an experimental investigation of shock-induced stall and leading-edge stall on a 64A010 airfoil section are presented. Advanced nonintrusive techniques - laser velocimetry and holographic interferometry - were used in characterizing the inviscid and viscous flow regions. The measurements include Mach contours of the inviscid now regions, and mean velocity, flow direction, and Reynolds shear stress profiles in the separated regions. The experimental observations of this study are relevant to efforts to improve surface-pressure prediction methods for airfoils at or near stall.

Johnson, D. A.↗

Radar Interferometry Studies of the Mass Balance of Polar Ice Sheets

The objectives of this work are to determine the current state of mass balance of the Greenland and Antarctic Ice Sheets. Our approach combines different techniques, which include satellite synthetic-aperture radar interferometry (InSAR), radar and laser altimetry, radar ice sounding, and finite-element modeling. In Greenland, we found that 3.5 times more ice flows out of the northern part of the Greenland Ice Sheet than previously accounted for. The discrepancy between current and past estimates is explained by extensive basal melting of the glacier floating sections in the proximity of the grounding line where the glacier detaches from its bed and becomes afloat in the ocean. The inferred basal melt rates are very large, which means that the glaciers are very sensitive to changes in ocean conditions. Currently, it appears that the northern Greenland glaciers discharge more ice than is being accumulated in the deep interior, and hence are thinning. Studies of temporal changes in grounding line position using InSAR confirm the state of retreat of northern glaciers and suggest that thinning is concentrated at the lower elevations. Ongoing work along the coast of East Greenland reveals an even larger mass deficit for eastern Greenland glaciers, with thinning affecting the deep interior of the ice sheet. In Antarctica, we found that glaciers flowing into a large ice shelf system, such as the Ronne Ice Shelf in the Weddell Sea, exhibit an ice discharge in remarkable agreement with mass accumulation in the interior, and the glacier grounding line positions do not migrate with time. Glaciers flowing rapidly into the Amudsen Sea, unrestrained by a major ice shelf, are in contrast discharging more ice than required to maintain a state of mass balance and are thinning quite rapidly near the coast. The grounding line of Pine Island glacier (see diagram) retreated 5 km in 4 years, which corresponds to a glacier thinning rate of 3.5 m/yr. Mass imbalance is even more negative on Thwaites Glacier. This sector of West Antarctica probably initiated its collapse decades or centuries ago, once the embaying ice shelves in front of them started to melt because of enhanced basal melting from warmer ocean waters. Additional information is contained in the original.

Rignot, Eric↗

Determination of the extragalactic-planetary frame tie from joint analysis of radio interferometric and lunar laser ranging measurements

Very Long Baseline Interferometry (VLBI) observations of extragalactic radio sources provide the basis for defining an accurate non-rotating reference frame in terms of angular positions of the sources. Measurements of the distance from the Earth to the Moon and to the inner planets provide the basis for defining an inertial planetary ephemeris reference frame. The relative orientation, or frame tie, between these two reference frames is of interest for combining Earth orientation measurements, for comparing Earth orientation results with theories referred to the mean equator and equinox, and for determining the positions of the planets with respect to the extragalactic reference frame. This work presents an indirect determination of the extragalactic-planetary frame tie from a combined reduction of VLBI and Lunar Laser Ranging (LLR) observations. For this determination, data acquired by LLR tracking stations since 1969 have been analyzed and combined with 14 years of VLBI data acquired by NASA's Deep Space Network since 1978. The frame tie derived from this joint analysis, with an accuracy of 0.003 sec, is the most accurate determination obtained so far. This result, combined with a determination of the mean ecliptic (defined in the rotating sense), shows that the mean equinox of epoch J2000 is offset from the x-axis of the extragalactic frame adopted by the International Earth Rotation Service for astrometric and geodetic applications by 0.078 sec +/- 0.010 sec along the y-direction and y 0.019 sec +/- 0.001 sec. along the z-direction.

Folkner, W. M.↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

Model-Independent Time-Delay Interferometry Based on Principal Component Analysis

With a laser interferometric gravitational-wave detector in separate free flying spacecraft, the only way to achieve detection is to mitigate the dominant noise arising from the frequency fluctuations of the lasers via postprocessing. The noise can be effectively filtered out on the ground through a specific technique called time-delay interferometry (TDI), which relies on the measurements of time-delays between spacecraft and careful modeling of how laser noise enters the interferometric data. Recently, this technique has been recast into a matrix-based formalism by several authors, offering a different perspective on TDI, particularly by relating it to principal component analysis (PCA). In this work, we demonstrate that we can cancel laser frequency noise by directly applying PCA to a set of shifted data samples, without any prior knowledge of the relationship between single-link measurements and noise, nor time-delays. We show that this fully data-driven algorithm achieves a gravitational-wave sensitivity similar to classic TDI.

Quentin Baghi↗

Dual-Beam Atom Laser Driven by Spinor Dynamics

An atom laser now undergoing development simultaneously generates two pulsed beams of correlated Rb-87 atoms. (An atom laser is a source of atoms in beams characterized by coherent matter waves, analogous to a conventional laser, which is a source of coherent light waves.) The pumping mechanism of this atom laser is based on spinor dynamics in a Bose-Einstein condensate. By virtue of the angular-momentum conserving collisions that generate the two beams, the number of atoms in one beam is correlated with the number of atoms in the other beam. Such correlations are intimately linked to entanglement and squeezing in atomic ensembles, and atom lasers like this one could be used in exploring related aspects of Bose-Einstein condensates, and as components of future sensors relying on atom interferometry. In this atom-laser apparatus, a Bose-Einstein condensate of about 2 x 10(exp 6) Rb-87 atoms at a temperature of about 120 micro-K is first formed through all-optical means in a relatively weak singlebeam running-wave dipole trap that has been formed by focusing of a CO2-laser beam. By a technique that is established in the art, the trap is loaded from an ultrahigh-vacuum magnetooptical trap that is, itself, loaded via a cold atomic beam from an upstream two-dimensional magneto-optical trap that resides in a rubidium-vapor cell that is differentially pumped from an adjoining vacuum chamber, wherein are performed scientific observations of the beams ultimately generated by the atom laser.

Thompson, Robert↗

Micro-displacement fiber sensor using two-frequency interferometry

A He-Ne Zeeman laser has been utilized as a two-frequency light source in a Michelson-type micro-displacement fiber sensor. A polarization maintaining fiber has been installed in the sensing arm, which facilitates flexibility and allows the sensing region to be remotely located. This fiber sensing arm is arranged to replace a quarterwave plate component. The fiber sensor system has a resolution of half a micrometer.

Tedjojuwono, Ken K.↗