Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation

Surrogate nuclear explosion debris (SNED) has emerged as a critical platform for advancing post-detonation nuclear forensic analysis in the absence of readily accessible historic materials. SNED enables controlled investigation and validation of analytical methodologies used to interrogate the chemical, isotopic, radiological, and microstructural signatures preserved in nuclear explosion debris. This review presents an integrated assessment of destructive and non-destructive analytical techniques commonly employed within decision-driven nuclear forensic workflows. Each technique is discussed individually while highlighting how it contributes to different stages of post-detonation analysis. Core methods – including gamma and alpha spectrometry, ICP-MS, TIMS, SIMS, SEM-EDS, XRF, LIBS, vibrational spectroscopy, and X-ray absorption spectroscopy – are critically evaluated with respect to forensic maturity, information content, and matrix limitations. Emphasis is placed on the role of SNED in benchmarking multi-modal workflows and identifying gaps in reproducing heterogeneity, fractionation, and radiation-driven evolution relevant to forensic attribution.

X-ray spectroscopic methods↗

Nuclear forensic analysis of uranium oxide powders interdicted in Victoria, Australia

Nuclear forensic analysis was conducted on two uranium samples confiscated during a police investigation in Victoria, Australia. The first sample, designated NSR-F-270409-1, was a depleted uranium powder of moderate purity (~1000 μg/g total elemental impurities). The chemical form of the uranium was a compound similar to K 2 (UO 2 ) 3 O 4 ·4H 2 O. While aliquoting NSR-F-270409-1 for analysis, the body and head of a Tineid moth was discovered in the sample. The second sample, designated NSR-F-270409-2, was also a depleted uranium powder. It was of reasonably high purity (~380 μg/g total elemental impurities). The chemical form of the uranium was primarily UO 3 ·2H 2 O, with minor phases of U 3 O 8 and UO 2 . While aliquoting NSR-F-270409-2 for analysis, a metal staple of unknown origin was discovered in the sample. The presence of 236 U and 232 U in both samples indicates that the uranium feed stocks for these samples experienced a neutron flux at some point in their history. The reactor burn-up calculated from the isotopic composition of the uranium is consistent with that of spent fuel from natural uranium (NU) fueled Pu production. These nuclear forensic conclusions allow us to categorically exclude Australia as the origin of the material and greatly reduce the number of candidate sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Age Dating of Mixed SNM--Preliminary Investigations

Recently we investigated the nuclear forensics problem of age determination for mixed special nuclear material (SNM). Through limited computational mixing experiments and interactive age analysis, it was observed that age dating results are generally affected by the mixing of samples with different assays or even by small radioactive material contamination. The mixing and contamination can be detected through interactive age analysis, a function provided by the Decay Interaction, Visualization and Analysis (DIVA) software developed by NSTec. It is observed that for mixed SNM with two components, the age estimators typically fall into two distinct clusters on the time axis. This suggests that averaging or other simple statistical methods may not always be suitable for age dating SNM mixtures. Instead, an interactive age analysis would be more suitable for age determination of material components of such SNM mixtures. This work was supported by the National Center for Nuclear Security (NCNS).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design and Application of TIMS-Based Thorium Measurement Methods in the Actinide Analytical Chemistry Group at Los Alamos National Laboratory

Quantitation of inter-related actinides in nuclear materials, whether they be intercepted (e.g. stolen fuel pellets) or purposefully collected (e.g. cotton swipe samples), is essential in modern nuclear forensics and safeguards. Well-designed procedures may provide insight into a material’s “age” (i.e. time since last purification), suggest processing/preparation routes, and point to involved parties. In the present work, we detail the design and preliminary application of a thermal ionization mass spectrometry (TIMS) based approach to the analysis of thorium-230 within uranium-bearing materials. These efforts are in-line with a chronometric-type analysis strategy and focused on identification of appropriate preparation procedures, development of required spiking materials (i.e. 229 Th), and evaluation of uranium certified reference materials (CRMs). The presence of thorium in these materials is expected to be largely due to a combination of the decay of parent uranium (e.g. 234 U) to daughter nuclides (e.g. 230 Th), and thorium persistence following last purification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model ages of three uranium metal CRMs and implications for radiochronometry data interpretation

In this study, we report 230 Th/ 234 U and 231 Pa/ 235 U model ages in three uranium metal certified reference materials with distinct production histories and isotopic compositions ranging from depleted to highly enriched (CRMs 112-A, 115, and 116-A). Here, our results provide the first model age values for these materials using multiple radiochronometers, which can be used as reference values for quality control of radiochronometry measurements performed during nuclear forensic investigations. Furthermore, we evaluate the model ages in the context of available production records for the materials, which provides insight into the processes that may impact radiochronometry systems during uranium metal production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Separation of gold from irradiated actinide material utilizing a 2- thenoyltrifluoroacetone extraction resin

Post-detonation nuclear forensics capabilities depend on the ability to rapidly isolate radionuclides to improve measurement quality. In this work an extraction chromatography resin was developed utilizing the extractants thenoyltrifluoroacetone and 1-octanol supported on Eichrom prefilter resin. Here the resin was tested in nitric and hydrochloric acid matrices. In nitric acid matrices the resin is able to extract zirconium, while in hydrochloric acid matrices it is possible to extract iron and gallium. In all acid conditions tested gold is retained but can be removed from the column with a 10% thiourea rinse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Lessons from Past Nuclear Disarmament: What Worked What Did Not

This report studies the efforts of the international community and the United States to verif)/ the denuclearization of various countries: Ukraine, South Africa, Iraq, Taiwan, and Libya. In doing so, it considers the verification of nuclear warhead destruction and the accounting of nuclear materials. Each case study contributes to the understanding we have of which verification procedures worked and which did not and what factors contributed to that success and which did not. The most important factor contributing to successful verification is the cooperation of the subject country. If a country has made the strategic decision to cooperate, then it is possible that verification can be successful. If the country chooses not to cooperate, verification might rest on random and unpredictable events. This unpredictability of verification is politically unacceptable. Even if verification is judged to be successful by the implementing agencies, outsiders can cast doubts on it by pointing out small and potentially unavoidable errors in material amounts verified. It is vitally important to systematically preserve forensic evidence, especially shipping and receiving records to avoid just such issues. Historically, such records are the most important evidence in verifying denuclearization. Technology is far less important than forensic analysis of records. It does play a supporting role in verifying some declarations but there can be an enormous delay in drawing conclusions caused by the necessity to analyze statistically large samples of materials. The confidence one gets from such analysis can be delayed well past the time it is politically significant. The most important advance in technology would be to accelerate that sample analysis process.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Machine learning in analytical spectroscopy for nuclear diagnostics [Invited]

Analytical spectroscopy methods have shown many possible uses for nuclear material diagnostics and measurements in recent studies. In particular, the application potential for various atomic spectroscopy techniques is uniquely diverse and generates interest across a wide range of nuclear science areas. Over the last decade, techniques such as laser-induced breakdown spectroscopy, Raman spectroscopy, and x-ray fluorescence spectroscopy have yielded considerable improvements in the diagnostic analysis of nuclear materials, especially with machine learning implementations. These techniques have been applied for analytical solutions to problems concerning nuclear forensics, nuclear fuel manufacturing, nuclear fuel quality control, and general diagnostic analysis of nuclear materials. The data yielded from atomic spectroscopy methods provide innovative solutions to problems surrounding the characterization of nuclear materials, particularly for compounds with complex chemistry. Implementing these optical spectroscopy techniques can provide comprehensive new insights into the chemical analysis of nuclear materials. In particular, recent advances coupling machine learning methods to the processing of atomic emission spectra have yielded novel, robust solutions for nuclear material characterization. This review paper will provide a summation of several of these recent advances and will discuss key experimental studies that have advanced the use of analytical atomic spectroscopy techniques as active tools for nuclear diagnostic measurements.

Rao, Ashwin P. (ORCID:0000000319312568)↗

Application of HRGS for forensic characterization of uranium oxides, pure uranium metals and uranium alloys

A nondestructive iterative method for uranium-bearing material characterization with HRGS developed earlier in (J. appl. Rad. Isotopes, 166 (2020) 109433) is applied to determine matrix densities and uranium isotope masses of a variety of uranium materials, namely uranium ore, UO 2 and U 3 O 8 powders, fuel elements in the form of UO2 microspheres, uranium metal and uranium alloys. It is shown that U 3 O 8 powders with uranium mass fraction of about 84% can be distinguished from the powders of UO 2 with uranium mass fraction of about 87%; uranium products in the form of liquid or loose powder with matrix density of 0.5-2.0 g/cm 3 can be distinguished from uranium products in the form of compacted fuel elements with matrix density of 6.0-10.0 g/cm 3 and from pure metal uranium and uranium alloys with matrix density of 14.0- 19.0 g/cm 3 . In fuel microspheres based on UO2 the uranium mass fraction 88.02% measured by HRGS is consistent, within the measurement uncertainties, with the results of isotope dilution mass spectrometry 87.76±0.64 % and also is confirmed by X-ray diffraction technique. The uranium mass fraction of the uranium ore estimated as 0.08% by HRGS is consistent, within the measurement uncertainties, with the value 0.09±0.01% determined with WDXRF. Densities of two different uranium metal samples, estimated as 18.42 g/cm 3 and 19.33 g/cm 3 by HRGS are consistent with values 18.24±0.55 g/cm 3 and 18.86±0.59 g/cm 3 , respectively, obtained by the gas pycnometry technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Qualitative assessment of uranium ore concentrates and related materials using scanning electron microscopy

Several studies have evaluated the morphology of uranium compounds produced under controlled conditions at the laboratory scale, but it is unclear whether the morphological characteristics of these materials persist in commercially produced uranium ore concentrates (UOCs). To assess the morphology in “real-world” UOCs, we qualitatively evaluated the morphological profile of secondary electron images from over 100 commercial UOCs using a previously published lexicon. We observe differences between samples with differing chemical composition and samples with similar chemical composition and differing provenance. Further, this work contextualizes morphology for commercially produced UOCs and will provide a basis for future machine learning efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials

Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of nine materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Arecibo Observatory Auxiliary M4N Socket Termination Failure Investigation

The NASA Engineering and Safety Center (NESC) was requested to support the Arecibo Observatory failure investigation in determining the root cause of the Auxiliary M4N cable failure. The NESC and Kennedy Space Center led an integrated NASA investigation with support from Marshall Space Flight Center and The Aerospace Corporation that included forensic investigation of failed hardware, finite element modeling, materials characterization, and root cause analysis. This document contains the outcome of the NESC Assessment.

Zinc Spelter Sockets↗

Thermal Microwave Kinetic Inductance Device, RSLN-023-16, Year 1 of 2

Presentation describes decay-energy spectroscopy as a transformative method for nondestructive isotopic assay of trace-level nuclear materials with potential applications in areas including nuclear forensics. This project concentrates on optimizing this technology for low-energy electron spectroscopy. Measurement of the decay by electron capture of holmium-163 (163Ho) was explored because its low energy decay, which allows accurate study of energy-resolution capabilities of decay-energy spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization Techniques for LiInSe{sub 2} Semiconducting Neutron Detector - Paper 55

As the world supply of helium continues to dwindle, alternatives to neutron detection have been a key focus area of radiation detection research. Solid-state neutron detectors are one possible alternative to the {sup 3}He detectors currently used for neutron detection when large detector areas are not required. Although {sup 6}Li and {sup 10}B are both also commonly used for neutron detection, neither has as high of a thermal cross section as {sup 3}He. The thermal cross sections for {sup 6}Li, {sup 10}B, and {sup 3}He are, respectively, 940 barns, 3840 barns, and 5330 barns. Both boron and helium are used in a gaseous form for neutron detection; however, there is no suitable gaseous form of lithium for neutron detection. Lithium is instead utilized in solid or liquid compounds for neutron detection. In this context, one area of interest is in the development of ternary A{sup I}B{sup III}C{sup IV} semiconductors comprised of isotopically-enriched lithium. Single crystal samples are being prepared through collaboration with the Y12 National Security Complex. This research focuses on the characterization of {sup 6}LiInSe{sub 2} (LISe) crystals, as well as on the development of prototype systems to assess the viability of using LISe crystals as a thermal neutron detector. Data to be obtained will provide previously untested physical parameters to facilitate growth optimization. Eventually, the refined crystals will be developed into solid-state, position-sensitive pixel detectors used for neutron imaging, among a wide array of possible applications including nuclear forensics. For the most part, the research team has been focused on mastering the detector fabrication processes, response tests on the first two batches of crystal samples, and the design of the first iteration detection system (Fig. 2). Response tests using alphas and neutrons have shown sensitivity to both particles. The first iteration detection system developed utilizes a 3-stage filter ladder of resistors and capacitors, similar to an ORTEC 142PC Preamplifier. Ideally, this ladder will reduce the noise associated with the high voltage power supply. The preamplifier is AC coupled to improve its counting rate capability (saturation), and critical components are on insulated posts. The custom circuit is housed in an aluminum box, and initial testing of the circuit has shown expected results. Investigation into further noise reduction is underway and will be the focus of the presented results. Upon completion and successful testing of the final detection system design, further development in spatial resolution and gamma/neutron discrimination will continue. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity and Uncertainty Analysis of Plutonium and Cesium Isotopes in Modeling of BR3 Reactor Spent Fuel

Nuclear forensics has a broad task to characterize recovered nuclear or radiological material and interpret the results of investigation. One approach to isotopic characterization of nuclear material obtained from a reactor is to chemically separate and perform isotopic measurements on the sample and verify the results with modeling of the sample history, for example, operation of a nuclear reactor. The major actinide plutonium and fission product cesium are commonly measured signatures of the fuel history in a reactor core. This study investigates the uncertainty of the plutonium and cesium isotope ratios of a fuel rod discharged from a research pressurized water reactor when the location of the sample is not known a priori. A sensitivity analysis showed overpredicted values for the 240 Pu/ 239 Pu ratio toward the axial center of the rod and revealed a lower probability of the rod of interest (ROI) being on the periphery of the assembly. The uncertainty analysis found the relative errors due to only the rod position and boron concentration to be 17% to 36% and 7% to 15% for the 240 Pu/ 239 Pu and 137 Cs/ 135 Cs ratios, respectively. Lastly, this study provides a method for uncertainty quantification of isotope concentrations due to the location of the ROI. Similar analyses can be performed to verify future chemical and isotopic analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Batch Extraction Studies to Evaluate Trace Element Behavior in PUREX Conditions

The multilab Intentional Forensics Venture is working to identify which stable elements (i.e., taggants) at trace concentrations relative to U would persist throughout the nuclear fuel cycle in a voluntary fuel tagging scheme. A taggant would provide the nuclear forensics community with a “barcode” to help identify nuclear materials found outside of regulatory control. A portion of this project was focused on reprocessing effects and determining which, if any, elements would coextract with U(VI) in standard Pu–U reduction extraction (PUREX) conditions. Elements with a propensity to coextract could, in theory, be used as taggants from a PUREX perspective. Although retention is not a performance requirement, the taggant signature would need to partition predictably from the U stream after the PUREX process to maintain forensic utility. This report documents results from several batch extraction studies with numerous trace elements from HNO 3 (1.5–5 M), with and without U(VI), into 30% tri-n-butyl phosphate (TBP) in kerosene. Extraction and back-extraction tests were used to evaluate nearly 60 elements in surrogate conditions for PUREX, and distribution coefficients (i.e., D-values) for most species were <0.1, indicating few species are likely to co-extract with U through PUREX. Additional studies are needed to optimize sample volumes and dilutions to dial in these low D-values. The D-values (D) were determined for several of the more promising elements, including Re and Se. Ultimately, we conclude that only a limited number of the ~ 60 elements investigated are extractable in the U stream of PUREX, based on measured D values, meaning most candidate elemental taggants would likely be lost at this stage of the nuclear fuel cycle, even when considering a range of acid concentrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ALPHA SPECTROMETRIC EVALUATION OF SRM-995 AS A POTENTIAL URANIUM/THORIUM DOUBLE TRACER SYSTEM FOR AGE-DATING URANIUM MATERIALS

Uranium-233 (t{sub 1/2} {approx} 1.59E5 years) is an artificial, fissile isotope of uranium that has significant importance in nuclear forensics. The isotope provides a unique signature in determining the origin and provenance of uranium-bearing materials and is valuable as a mass spectrometric tracer. Alpha spectrometry was employed in the critical evaluation of a {sup 233}U standard reference material (SRM-995) as a dual tracer system based on the in-growth of {sup 229}Th (t{sub 1/2} {approx} 7.34E3 years) for {approx}35 years following radiochemical purification. Preliminary investigations focused on the isotopic analysis of standards and unmodified fractions of SRM-995; all samples were separated and purified using a multi-column anion-exchange scheme. The {sup 229}Th/{sup 233}U atom ratio for SRM-995 was found to be 1.598E-4 ({+-} 4.50%) using recovery-corrected radiochemical methods. Using the Bateman equations and relevant half-lives, this ratio reflects a material that was purified {approx} 36.8 years prior to this analysis. The calculated age is discussed in contrast with both the date of certification and the recorded date of last purification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗