Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Algorithms for Haptic Rendering of 3D Objects

Algorithms have been developed to provide haptic rendering of three-dimensional (3D) objects in virtual (that is, computationally simulated) environments. The goal of haptic rendering is to generate tactual displays of the shapes, hardnesses, surface textures, and frictional properties of 3D objects in real time. Haptic rendering is a major element of the emerging field of computer haptics, which invites comparison with computer graphics. We have already seen various applications of computer haptics in the areas of medicine (surgical simulation, telemedicine, haptic user interfaces for blind people, and rehabilitation of patients with neurological disorders), entertainment (3D painting, character animation, morphing, and sculpting), mechanical design (path planning and assembly sequencing), and scientific visualization (geophysical data analysis and molecular manipulation).

Basdogan, Cagatay↗

VfOx in GEER: Functional Test of a Venus Oxygen Fugacity Sensor

VfOx, which stands for “Venus Oxygen Fugacity” is the DAVINCI mission’s Student Collaboration Experiment (SCE); a small single- objective sensor used to measure the partial pressure of molecular oxygen in Venus’ lower atmosphere. Through the mission timeline, VƒOx will be designed, fabricated, tested, operated, and results analyzed by undergraduate and graduate students mentored by the DAVINCI team in partnership with Johns Hopkins University and other institutions. The simple principal of VƒOx is a ceramic O 2 sensor derived from common applications, utilizing diffusion of O -2 ions between a standard (PdO) inside the sensor and the target atmosphere measured by a mW level voltage that depends directly on the standard/sample fO 2 ratio. A 60-day environmental test of a prototype design of the sensor was conducted at the Glenn Extreme Environment Rig (GEER) from August to October of 2022, in which VƒOx (Fig. 1) was placed inside the experimental chamber (Fig. 2) and brought to Venus surface temperature (460 °C) and pressure (92 bar) conditions, in a Venus like atmosphere (96.5% CO 2 , 3.5% N 2 ) that included trace gases like SO 2 , maintained by occasional “boosts” of extra gas during the experimental run.

Noam R. Izenberg↗

CO2 Removal Onboard the International Space Station – Material Selection and System Design

The previous three years of efforts have focused on the study of the sorbent materials available for use in a 4-bed molecular sieve system. The accumulation of knowledge has been invaluable for further decisions and for reflecting on the conclusions of past decisions. The goal of the next system is perfect uptime for nearly 20,000 hours of operation, but no complex life support system has yet reached this lofty goal. In addition to reliability, CO2 removal performance improvements have been intensively studied. The achievements toward this end include highly detailed isotherm measurements which drive system simulations as well as testing physical design improvements. Looking back on the successes and failures of past systems, correlating tests with long-duration data, and carefully projecting the future are all needed for the success of the next system. This work intends to reveal the path we have taken and illuminate the steps to come for CO2 removal life support with the 4BCO2 flight demonstration.

Cmarik, Gregory E.↗

The importance of atomic and molecular correlation on the bonding in transition metal compounds

The determination of accurate spectroscopic parameters for molecular systems containing transition metal atoms is shown to require extensive data sets and a high level correlation treatment, and techniques and their limitations are considered. Extensive results reported on the transition metal atoms, hydrides, oxides, and dimers makes possible the design of a calculation to correctly describe the mixing of different atomic asymptotes, and to give a correct balance between molecular bonding and exchange interactions. Examples considered include the dipole moment of the 2Delta state of NiH, which can help determine the mixture of 3d(8)4s(2) and 3d(9)4s(1) in the NiH wavefunction, and the bonding in CrO, where an equivalent description of the relative energies associated with the Cr 3d-3d atomic exchange and the Cr-O bond is important.

Bauschlicher, Charles W., Jr.↗

High-Flow, High-Molecular-Weight, Addition-Curing Polyimides

In developed series of high-flow PMR-type polyimide resins, 2, 2'-bis(trifluoromethyl)-4, 4'-diaminobiphenyl (BTDB) substituted for 1, 4-pheylenediamine in PMR-II formulation. Polyimides designated either as PMR-12F when nadic ester (NE) end caps used, or as V-CAP-12F when p-aminostyrene end caps used. High-molecular-weight, addition-curing polyimides based on BTBD and HFDE highly processable high-temperature matrix resins used to make composite materials with excellent retention of properties during long-term exposure to air at 650 degrees F or higher temperature. Furthermore, 12F addition-curing polyimides useful for electronic applications; fluorinated rigid-rod polyimides known to exhibit low thermal expansion coefficients as well as low absorption of moisture.

Chuang, Kathy C.↗

A systematic investigation of the preparation and properties of composite carbon molecular sieves containing inorganic oxides

The objective of this research is to define the methodology for the preparation and characterization of new carbon-based molecular sieves with composite structures. Carbon molecular sieves have found increasing application in the field of separation and purification of gases. These materials are relatively easy to prepare and their surfaces can be modified to some extent. It is expected that by combining inorganic oxides with the carbonaceous structure one can begin to design composite materials with a wider range of possible chemical and physical properties. In this way, the IOM-CMS materials may confer distinct advantages over pure carbon molecular sieves, not just for separation, but also for catalysis. The most recent results in the design and characterization of these IOM-CMS materials are reviewed and summarized. Directions for further research are also presented.

Foley, Henry C.↗

Time-of-flight velocity analysis of atomic and molecular beams

Conditions required for resolving a given beam speed distribution were evaluated by calculating the time-of-flight (TOF) signal for a finite open time of the beam shutter. Design criteria for a beam chopper and detection system are discussed in terms of the resolution, the range of speeds to be measured, and the optimum signal to noise ratio. A TOF system for detection of high intensity molecular beams with large speed ratios, as well as for low intensity scattered beams, is described. Experimental results are presented.

Hagena, O. F.↗

A rocket-borne airglow photometer

The design of a rocket-borne photometer to measure the airglow emission of ionized molecular nitrogen in the 391.4 nm band is presented. This airglow is a well known and often observed phenomenon of auroras, where the principal source of ionization is energetic electrons. It is believed that at some midlatitude locations energetic electrons are also a source of nighttime ionization in the E region of the ionosphere. If this is so, then significant levels of 391.4 nm airglow should be present. The intensity of this airglow will be measured in a rocket payload which also contains instrumentation to measured in a rocket payload which also contains instrumentation to measure energetic electron differential flux and the ambient electron density. An intercomparison of the 3 experiments in a nightime launch will allow a test of the importance of energetic electrons as a nighttime source of ionization in the upper E region.

Paarmann, L. D.↗

Bipropellant rocket exhaust plume analysis on the Galileo spacecraft

This paper describes efforts to quantify the contaminant flow field produced by 10 N thrust bipropellant rocket engines used on the Galileo spacecraft. The prediction of the composition of the rocket exhaust by conventional techniques is found to be inadequate to explain experimental observations of contaminant deposition on moderately cold (200 K) surfaces. It is hypothesized that low volatility contaminants are formed by chemical reactions which occur on the surfaces. The flow field calculations performed using the direct simulation Monte Carlo method give the expected result that the use of line-of-sight plume shields may have very little effect on the flux of vapor phase contaminant species to a surface, especially if the plume shields are located so close to the engine that the interaction of the plume with the shield is in the transition flow regime. It is shown that significant variations in the exhaust plume composition caused by nonequilibrium effects in the flow field lead to very low concentrations of species which have high molecular weights in the more rarefied regions of the flow field. Recommendations for the design of spacecraft plume shields and further work are made.

Guernsey, C. S.↗

Hormone purification by isoelectric focusing in space

The objective of the program was the definition and development of optimal methods for electrophoretic separations in microgravity. The approach is based on a triad consisting of ground based experiments, mathematical modeling and experiments in microgravity. Zone electrophoresis is a rate process, where separation is achieved in uniform buffers on the basis of differences in electrophoretic mobilities. Optimization and modeling of continuous flow electrophoresis mainly concern the hydrodynamics of the flow process, including gravity dependent fluid convection due to density gradients and gravity independent electroosmosis. Optimization of focusing requires a more complex model describing the molecular transport processes involved in electrophoresis of interacting systems. Three different focusing instruments were designed, embodying novel principles of fluid stabilization. Fluid stability was achieved by: (1) flow streamlining by means of membrane elements in combination with rapid fluid recycling; (2) apparatus rotation in combination with said membrane elements; and (3) shear stress induced by rapid recycling through a narrow gap channel.

Bier, M.↗

Development of High Quantum Efficiency UV/Blue Photocathode Epitaxial Semiconductor Heterostructures for Scintillation and Cherenkov Radiation Detection

The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.

Leopold, Daniel J.↗

Radiation: microbial evolution, ecology, and relevance to mars missions

Ultraviolet (UV) radiation has been an important environmental parameter during the evolution of life on Earth, both in its role as a mutagen and as a selective agent. This was probably especially true during the time from 3.8 to 2.5 billion years ago, when atmospheric ozone levels were less than 1% of present levels. Early Mars may not have had an "ozone shield" either, and it never developed a significant one. Even though Mars is farther away from the Sun than the Earth, a substantial surficial UV flux is present on Mars today. But organisms respond to dose rate, and on Mars, like on Earth, organisms would be exposed to diurnal variations in UV flux. Here we present data on the effect of diurnal patterns of UV flux on microbial ecosystems in nature, with an emphasis on photosynthesis and DNA synthesis effects. These results indicate that diurnal patterns of metabolism occur in nature with a dip in photosynthesis and DNA synthesis in the afternoon, in part regulated by UV flux. Thus, diurnal patterns must be studied in order to understand the effect of UV radiation in nature. The results of this work are significant to the success of human missions to Mars for several reasons. For example, human missions must include photosynthetic organisms for food production and likely oxygen production. An evolutionary approach suggests which organisms might be best suited for high UV fluxes. The diurnal aspect of these studies is critical. Terraforming is a potential goal of Mars exploration, and it will require studies of the effect of Martian UV fluxes, including their diurnal changes, on terrestrial organisms. Such studies may suggest that diurnal changes in UV only require mitigation at some times of day or year.

Review, Tutorial↗

Ndarts

Ndarts software provides algorithms for computing quantities associated with the dynamics of articulated, rigid-link, multibody systems. It is designed as a general-purpose dynamics library that can be used for the modeling of robotic platforms, space vehicles, molecular dynamics, and other such applications. The architecture and algorithms in Ndarts are based on the Spatial Operator Algebra (SOA) theory for computational multibody and robot dynamics developed at JPL. It uses minimal, internal coordinate models. The algorithms are low-order, recursive scatter/ gather algorithms. In comparison with the earlier Darts++ software, this version has a more general and cleaner design needed to support a larger class of computational dynamics needs. It includes a frames infrastructure, allows algorithms to operate on subgraphs of the system, and implements lazy and deferred computation for better efficiency. Dynamics modeling modules such as Ndarts are core building blocks of control and simulation software for space, robotic, mechanism, bio-molecular, and material systems modeling.

Jain, Abhinandan↗

A Very High Resolution Mid Infrared Spectrograph for SOFIA

The purpose of this project was to study the design of a high resolution mid-infrared spectrograph for the SOFIA airborne observatory. The primary motivation for the construction and use of such an instrument is the study of vibrational transitions of molecules in molecular clouds, circumstellar inflows and outflows, and planetary atmospheres, which are blocked from ground-based observations by absorption by the Earth's atmosphere. The instrument design studied is a cross-dispersed grating spectrograph with several modes of operation giving spectral resolving powers of approximately 4000, 20,000, and 100,000. In the two lower resolution modes a single grating is used in a long-slit spectrograph. At high resolution that grating serves as the cross-disperser for a 1-m long echelon, a very coarsely and steeply ruled grating, diamond-machined in aluminum. Several design study tasks were carried out: 1. An optical and mechanical design was developed. It differed from the preliminary design by using a reflecting focal reducer in the fore-optics and by rearranging the echelon and cross-dispersing chambers to improve the efficiency of the long-slit modes. 2. A finite-element analysis of the dewar and echelon support structures was done. It led us to change the echelon support to improve its rigidity. 3. Further information was obtained which convinced us that Hyperfine Inc. was capable of diamond-machining the echelon. 4. Several possible vendors of readout electronics and software were identified. It was decided that it is more cost-effective to purchase these items rather than developing them ourselves. 5. Observing and calibration procedures were studied. we did not identify significant changes needed from procedures used previously. 6. Possible expansions of instrument capabilities, including wavelength coverage, were studied. It appears unlikely that the echelon will perform well at wavelengths shortward of 5 microns, but the spectral coverage could be extended longward of 28 microns with the use of an Si:Sb detector. No patentable inventions were made during this study. Based on this design study, a proposal was submitted to construct the instrument. It was chosen as one of the first-light instruments for SOFIA.

Lacy, John H.↗

Mass analysis of neutral particles and ions released during electrical breakdowns on spacecraft surfaces

A specialized spectrometer was designed and developed to measure the mass and velocity distributions of neutral particles (molecules and molecular clusters) released from metal-backed Teflon and Kapton films. Promising results were obtained with an insulation breakdown initiation system based on a moveable contact touching the insulated surfaces. A variable energy, high voltage pulse is applied to the contact. The resulting surface damage sites can be made similar in size and shape to those produced by a high voltage electron beam system operating at similar discharge energies. The point discharge apparatus was used for final development of several high speed recording systems and for measurements of the composition of the materials given off by the discharge. Results with this apparatus show evolution of large amounts of fluorocarbon fragments from discharge through Teflon FEP, while discharges through Kapton produce mainly very light hydrocarbon fragments at masses below about 80 a.m.u.

Kendall, B. R. F.↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗

Design and development of an all-solid-state laser unit for microgravity combustion applications

The laser-induced fluorescence (LIF) technique is a sensitive and noninvasive method for imaging of flames and for monitoring of temperature and the presence of transient molecular species in flames. Our research effort has two major objectives: (1) to use LIF to study the fundamentals of microgravity combustion via spectroscopic characterization of free radicals, and (2) to design and develop an all-solid-state portable laser unit for combustion studies in a microgravity environment. Well-characterized free radicals, namely hydroxyl (OH) and methoxy (CH3O), have analytically convenient bands that can be laser-excited in the 280-298 nm spectral region with the newly discovered solid-state tunable laser, which is based on the LiCaAIF6:Ce3+(LiCAF:Ce) single crystal pumped by the quadrupled (266 nm) output of a Q-switched YAG:Nd laser. The 266 nm YAG radiation (of about 10 mJ pulse energy) was split into two beams of about equal intensity, one used for photolysis of the free radical precursor and the other used for pumping the laser crystal. Tunability of the LiCAF:Ce laser was provided by a step-motor-driven Littrow-mounted diffraction grating. Laser excitation spectra of the CH3O radical was recorded in the 291.5-296.5 nm region with 0.15 cm(exp -1) resolution. Laboratory experiments have thus successfully shown that the idea of using the LiCAF:Ce laser as a dual-purpose photolysis and excitation source can pay rich dividends and that such a laser can be the center piece of an all-solid-state portable device that can be used for routine analytical investigations of microgravity combustion phenomena.

Kamal, Mohammed M.↗