Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexing readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Multiplexed Holographic Data Storage in Bacteriorhodopsin

Biochrome photosensitive films in particular Bacteriorhodopsin exhibit features which make these materials an attractive recording medium for optical data storage and processing. Bacteriorhodopsin films find numerous applications in a wide range of optical data processing applications; however the short-term memory characteristics of BR limits their applications for holographic data storage. The life-time of the BR can be extended using cryogenic temperatures [1], although this method makes the system overly complicated and unstable. Longer life-times can be provided in one modification of BR - the "blue" membrane BR [2], however currently available films are characterized by both low diffraction efficiency and difficulties in providing photoreversible recording. In addition, as a dynamic recording material, the BR requires different wavelengths for recording and reconstructing of optical data in order to prevent the information erasure during its readout. This fact also put constraints on a BR-based Optical Memory, due to information loss in holographic memory systems employing the two-lambda technique for reading-writing thick multiplexed holograms.

Mehrl, David J.↗

Practical Considerations for Optimizing Position Sensitivity in Arrays of Position-sensitive TES's

We are developing Position-Sensitive Transitions-Edge Sensors (PoST's) for future X-ray astronomy missions such as NASA's Constellation-X. The PoST consists of one or more Transitions Edge Sensors (TES's) thermally connected to a large X-ray absorber, which through heat diffusion, gives rise to position dependence. The development of PoST's is motivated by the desire to achieve the largest the focal-plan coverage with the fewest number of readout channels. In order to develop a practical array, consisting of an inner pixellated core with an outer array of large absorber PoST's, we must be able to simultaneously read out all (-1800) channels in the array. This is achievable using time division multiplexing (TDM), but does set stringent slew rate requirements on the array. Typically, we must damp the pulses to reduce the slew rate of the input signal to the TDM. This is achieved by applying a low-pass analog filter with large inductance to the signal. This attenuates the high frequency components of the signal, essential for position discrimination in PoST's, relative to the white noise of the readout chain and degrades the position sensitivity. Using numerically simulated data, we investigate the position sensing ability of typical PoST designs under such high inductance conditions. We investigate signal-processing techniques for optimal determination of the event position and discuss the practical considerations for real-time implementation.

Smith, Stephen J.↗

Novel multiplexing technique for detector and mixer arrays

Future space submillimeter telescopes will require large-format imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is combatible with large numbers of cryogenic detectors elements.

submillimeter↗

Multicolor Detectors for Ultrasensitive Long-Wave Imaging Cameras

A document describes a zeptobolometer for ultrasensitive, long-wavelength sensors. GSFC is developing pixels based on the zeptobolometer design that sense three THz wavelengths simultaneously. Two innovations are described in the document: (1) a quasiparticle (QO) filter arrangement that enables a compact multicolor spectrum at the focal plane, and (2) a THz antenna readout by up to three bolometers. The innovations enable high efficiency by greatly reducing high, frequency-dependent microstrip losses, and pixel compactness by eliminating the need for bulky filters in the focal plane. The zeptobolometer is a small TES bolometer, on the scale of a few microns, which can be readily coupled through an impedance-matching resistor to a metal or dielectric antenna. The bolometer is voltage-biased in its superconducting transition, allowing the use of superconducting RF multiplexers to read out large arrays. The antenna is geometrically tapped at three locations so as to efficiently couple radiation of three distinct wavelengths to the individual TESs. The transition edge hot electrons in metals offer a simple, compact arrangement for antenna readout, which can be crucial in the THz where line losses at high frequencies can be substantial. A metallic grill filter acts as a high-pass filter and directs the low-frequency components to a location where they will be absorbed. The absorption spectrum shows that three well-separated THz bands are feasible. The filters can be made from high-purity dielectrics such as float zone silicon or sapphire.

Brown, Ari↗

Science Enabling ASICs and FEEs for the JUICE and JEO Missions

A family of science enabling radiation hard Application Specific Integrated Circuits (ASICs), Front End Electronics (FEEs) and Event Processing Systems, with flight heritage on many NASA missions, is presented. These technologies play an important role in the miniaturization of instruments -and spacecraft systems- at the same time increasing performance and reducing power. The technologies target time of flight, position sensing, and energy measurements as well as standard housekeeping and telemetry functions for particle and fields instruments, but find applications in other instrument categories too. More specifically the technologies include: the TOF chip, 1D and 2D Delay Lines with MCP detectors, for high precision fast and low power time of flight and position sensing; the Energy chip for multichannel SSD readout with time over threshold and standard voltage read out for TDC and ADC digitization; Fast multi channel read out chip with commandable thresholds; the TRIO chip for multiplexed ADC and housekeeping etc. It should be mentioned that the ASICs include basic trigger capabilities to enable random event processing in a heavy background of penetrators and UV foreground. Typical instruments include time of flight versus energy and look angle particle analyzers such as: plasma composition, energetic particle, neutral atom imaging as well as fast plasma and deltaE/E ion/electron telescopes. Flight missions include: Cassini/LEMMS, IMAGE/HENA, MESSENGER/EPPS/MLA/X-ray/MLA, STEREO, PLUTO-NH/PEPSSI/LORI, IBEX-Lo, JUNO/JEDI, RBSP/RBSPICE, MMS/HPCA/EPD, SO/SIS. Given the proven capability on heavy radiation missions such as JUNO, MMS and RBSB, as well diverse long duration missions such as MESSENGER, PLUTO and Cassini, it is expected that these technologies will play an important role in the particle and fields (at least) instruments on the upcoming JUICE and JEO missions.

Paschalidis, Nicholas↗

A Kinetic Inductance Ammeter with Coplanar Waveguide Input Structure for Magnetic Flux Focusing

We propose a multiplexible kinetic inductance ammeter, which uses a high-quality-factor, superconducting, lumped-element, kinetic inductance resonator as a current sensor, a short, superconducting coplanar waveguide (CPW) for current input, and a CPW transmission line for the sensor readout. The resonator consists of an interdigitated capacitor and a superconducting loop that inductively couples to the input CPW. Current running through the central line of the input CPW generates magnetic fields which are focused into the gaps of the input CPW. These magnetic fields can be measured collectively as the magnetic flux through the superconducting loop. The kinetic inductance of the superconducting loop depends on the screening current for the magnetic flux, so the input current is converted to a change in the frequency of the resonator. We analyze the response and noise of a kinetic inductance ammeter with a high-resistivity NbN loop.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radio for hidden-photon dark matter detection

We propose a resonant electromagnetic detector to search for hidden-photon dark matter over an extensive range of masses. Hidden-photon dark matter can be described as a weakly coupled “hidden electric field,” oscillating at a frequency fixed by the mass, and able to penetrate any shielding. At low frequencies (compared to the inverse size of the shielding), we find that the observable effect of the hidden photon inside any shielding is a real, oscillating magnetic field. We outline experimental setups designed to search for hidden-photon dark matter, using a tunable, resonant LC circuit designed to couple to this magnetic field. Our “straw man” setups take into consideration resonator design, readout architecture and noise estimates. At high frequencies, there is an upper limit to the useful size of a single resonator set by 1/ν. However, many resonators may be multiplexed within a hidden-photon coherence length to increase the sensitivity in this regime. Hidden-photon dark matter has an enormous range of possible frequencies, but current experiments search only over a few narrow pieces of that range. As a result, we find the potential sensitivity of our proposal is many orders of magnitude beyond current limits over an extensive range of frequencies, from 100 Hz up to 700 GHz and potentially higher.

79 ASTRONOMY AND ASTROPHYSICS↗

Superconducting kinetic inductance photon detectors.

We are investigating a novel superconducting detector and readout method that could lead to photon counting, energy resolving focal plane arrays. This concept is intrinsically different from STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution in the ptical/UV/X-ray bands. The readout uses the monotonic relation between the kinetic surface inductance L***subs***, of a superconductor and the density of quasiparticles n, which holds even at temperatures far below T***subc***. This allows a sensitive readout of the number of excess quasiparticles in the detector by monitoring the transmission phase of a resonant circuit. The most intriguing aspect of this concept is that passive frequency multiplexing could be used to read out ~ l0***super4*** detectors with a single HEMT amplifier. Single x-ray events have been observed in prototype detectors.

kinetic↗

280 GHz Focal Plane Unit Design and Characterization for the Spider-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne Spider instrument. These FPUs are vital to Spider’s primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a $16 \times 16$ grid of corrugated silicon feedhorns coupled to an array of aluminum–manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be $\sim $ 3 pW at 300 mK with a less than 6% variation across each array at $1\sigma $ . These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the Spider-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital optical recorder-reproducer system

A mass archival optical recording and reproduction system includes a recording light source such as a laser beam focussed and directed upon an acousto-optic linear modulator array (or page composer) that receives parallel blocks of data converted from a serial stream of digital data to be stored. The page composer imparts to the laser beam modulation representative of a plurality of parallel channels of data and through focussing optics downstream of the page composer parallel arrays of optical spots are recorded upon a suitable recording medium such as a photographic film floppy disc. The recording medium may be substantially frictionlessly and stably positioned for recording at a record/read station by an air-bearing platen arrangement which is preferably thermodynamically non-throttling so that the recording film may be positioned in the path of the information-carrying light beam in a static or dynamic mode. During readout, the page composer is bypassed and a readout light beam is focussed directly upon the recording medium containing an array of previously recorded digital spots, a sync bit, data positioning bits, and a tracking band. The readout beam which has been directed through the recording medium is then imaged upon a photodetector array, the output of which may be coupled to suitable electronic processing circuitry, such as a digital multiplexer, whereby the parallel spot array is converted back into the original serial data stream.

Reddersen, Brad R.↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors

Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, cosmic microwave background, mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to transition-edge sensors or microwave kinetic inductance detectors. In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator’s excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at ~ 6 MHz with center frequencies ~ 5–6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.

47 OTHER INSTRUMENTATION↗

A low-noise CMOS pixel direct charge sensor, Topmetal-II -

In this paper, we report the design and characterization of a CMOS pixel direct charge sensor, Topmetal-II-, fabricated in a standard 0.35 μm CMOS Integrated Circuit process. The sensor utilizes exposed metal patches on top of each pixel to directly collect charge. Each pixel contains a low-noise charge-sensitive preamplifier to establish the analog signal and a discriminator with tunable threshold to generate hits. The analog signal from each pixel is accessible through time-shared multiplexing over the entire array. Hits are read out digitally through a column-based priority logic structure. Tests show that the sensor achieved a <15e - analog noise and a 200e - minimum threshold for digital readout per pixel. The sensor is capable of detecting both electrons and ions drifting in gas. Lastly, these characteristics enable its use as the charge readout device in future Time Projection Chambers without gaseous gain mechanism, which has unique advantages in low background and low rate-density experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a {sup 153}Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/√(Hz) at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than 10{sup 3} elements and spectral resolving powers R=λ/Δλ>10{sup 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monolithic InSb imaging arrays with charge-coupled device /CCD/ readout

The paper demonstrates the detection of infrared radiation and signal readout on a monolithic InSb charge coupled infrared imaging device. The device is a 20-element linear imager with MOS detectors coupled to a four-phase, surface-channel, charge transfer structure. The charge transfer device is p-channel and has planar ion implanted diode structures for zero input and charge readout. Sensitivity measurements on the MOS infrared detectors were determined for the 20-element array. Data are presented on the operational characteristics of the 20-element linear imager under various conditions of electrical and optical inputs in both multiplexed and a time delay and integration (TDI) mode. Plans are discussed for a monolithic InSb 100-element linear imager and a 20 x 16 TDI linear imager.

Miller, W. E.↗

Multiplexed Colorimetric Solid-Phase Extraction

Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

Gazda, Daniel B.↗

Cryogenic switched MOSFET characterization

Both p channel and n channel enhancement mode MOSFETs can be readily switched on and off at temperatures as low as 2.8 K so that switch sampled readout of a VLWIR Ge:Ga focal plane is electronically possible. Noise levels as low as 100 rms electrons per sample (independent of sample rate) can be achieved using existing p channel MOSFETs, at overall rates up to 30,000 samples/second per multiplexed channel (e.g., 32 detectors at a rate of almost 1,000 frames/second). Run of the mill devices, including very low power dissipation n channel FETs would still permit noise levels of the order of 500 electrons/sample.

Source record↗