Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Methods for Quantifying the Uncertainties of LSIT Test Parameters, Test Results, and Full-Scale Mixing Performance Using Models Developed from Scaled Test Data

This report discusses the statistical methods for quantifying uncertainties in 1) test responses and other parameters in the Large Scale Integrated Testing (LSIT), and 2) estimates of coefficients and predictions of mixing performance from models that relate test responses to test parameters. Testing at a larger scale has been committed to by Bechtel National, Inc. and the U.S. Department of Energy (DOE) to “address uncertainties and increase confidence in the projected, full-scale mixing performance and operations” in the Waste Treatment and Immobilization Plant (WTP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Information about Practicums at Los Alamos

The Los Alamos Neutron Science Center is the premier facility for neutron science experiments ranging from cross section measurements, neutron scattering experiments, proton radiography, cold neutrons, actinide neutronic properties, and many other exciting topics. The National High Magnetic Field Laboratory is home to several powerful magnets, including the one that created the first non-destructive 100 Tesla field in March 2012. They probe the electronic structure of superconductors, magnetic properties of materials (including magneto-quantum effects). Research is also conducted in correlated materials, thermoacoustics, and magnetic properties of actinides. The Trident Laser has a unique niche with very high power, short pulse experiments, with a peak power of 10{sup 20} W in short pulse mode. Discoveries range from production of monoenergetic MeV ion beam, nonlinear kinetic plasma waves, the transition between kinetic and fluid nonlinear behavior and other laser-plasma interaction processes.

36 MATERIALS SCIENCE↗

Toward a new nanoLIFT transfer process

The Laser Induced Forward Transfer (LIFT) is a direct-write technique used to print biological materials such as living cells or molecules. During the LIFT process, the biomaterial to be printed is deposited on a target submitted to a nanosecond laser shot, and the ejecta are collected onto a receiving substrate. Despite the several advantages of this technique (control of the propelled quantity, no spoiling of the substrate), it remains difficult to be employed due to the high sensitivity of its control parameters. Recently, Duocastella published some experimental results which exhibit the real-time jet formation process, under conditions similar to those present in the LIFT process. In the first Section, a typical experimental setup for LIFT process is presented. Then, simulations of Duocastella's and Guillemot's experiments are carried out to model the jet formation in water when irradiated by an ultraviolet nanosecond laser pulse. The 2D axisymmetric hydrodynamic code CHIC (Code d'Hydrodynamique et d'Implosion du CELIA) is used for these simulations with included equations of state (EOS) to take into account the behavior of water under standard conditions. Finally, an improvement of the LIFT technique which consists in using femtosecond lasers instead of nanosecond ones, is presented. It would allow to process smaller bioelements and to control the jet diameter, as it is directly related to the laser beam waist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid state NMR method development and studies of biological and biomimetic nanocomposites

This thesis describes application and development of advanced solid-state nuclear magnetic resonance techniques for complex materials, in particular organic-inorganic nanocomposites and thermoelectric tellurides. The apatite-collagen interface, essential for understanding the biomineralization process in bone and engineering the interface for controlled bio-mimetic synthesis and optimized mechanical properties, is buried within the nanocomposite of bone. We used multinuclear solid-state NMR to study the composition and structure of the interface. Citrate has been identified as the main organic molecule strongly bound to the apatite surface with a density of 1/(2 nm) 2 , covering 1/6 of the total surface area in bovine bone. Citrate provides more carboxylate groups, one of the key functional groups found to affect apatite nucleation and growth, than all the non-collagenous proteins all together in bone; thus we propose that citrate stabilizes apatite crystals at a very small thickness of ~3 nm (4 unit cells) to increase bone fracture tolerance. The hypothesis has been confirmed in vitro by adding citrate in the bio-mimetic synthesis of polymerhydroxyapatite nanocomposites. The results have shown that the size of hydroxyapatite nanocrystals decreases as increasing citrate concentration. With citrate concentrations comparable to that in body fluids, similar-sized nanocrystals as in bone have been produced. Besides the dimensions of the apatite crystals, the composition of bone also affects its biofunctional and macroscopic mechanical properties; therefore, our team also extended its effort to enhance the inorganic portion in our bio-mimetic synthesis from originally 15 wt% to current 50 wt% compared to 65 wt% in bovine bone, by using Lysine-Leucine hydroxyapatite nucleating diblock co-polypeptide, which forms a gel at very low concentration. In this thesis, various advanced solid state NMR techniques have been employed to characterize nanocomposites. Meanwhile, we have developed new methods to achieve broadband high resolution NMR and improve the accuracy of inter-nuclear distance measurements involving quadrupolar spins. Broadband high resolution NMR of spin-1/2 nuclei has been accomplished by the adaptation of the magic angle turning (MAT) method to fast magic angle spinning, termed fast MAT, by solving technical problems such as off resonance effects. Fast MAT separates chemical shift anisotropy and isotropic chemical shifts over a spectral range of ~1.8 γB 1 without significant distortions. Fast MAT 125 Te NMR has been applied to study technologically important telluride materials with spectra spreading up to 190 kHz. The signal-to-noise ratio of the spectra is significantly improved by using echo-matched Gaussian filtering in offline data processing. The accuracy of the measured distances between spin-1/2 and quadrupolar nuclei with methods such as SPIDER and REAPDOR has been improved by compensating for the fast longitudinal quadrupolar relaxation on the sub-millisecond with a modified S 0 pulse sequence. Also, the T1Q effect on the spin coherence and its spinning speed dependency has been explored and documented with analytical and numerical simulations as well as experimental measurements.

36 MATERIALS SCIENCE↗

Mapping structures and dynamics with frequency-correlated diffusion exchange

Understanding molecular motion in diffusion-driven complex environments is critical for designing sustainable materials and improving chemical processes. Here, we introduce a multidimensional nuclear magnetic resonance (NMR) method that captures how molecular populations exchange across different dynamic regimes. By extending the modulated gradient spin-echo technique to include frequency-frequency correlations, our approach reveals diffusion pathways that are otherwise obscured in heterogeneous systems. Implemented on a unilateral NMR magnet, the method eliminates gradient pulsing constraints and accesses dynamics in the kilohertz regime. We apply this technique to swelling and acid-catalyzed deconstruction of cross-linked and linear polymers to observe how structural heterogeneity evolves over time. By linking molecular motion to topology and chemical state, we extract physical metrics such as fractal surface dimensionality and reaction wavefront velocity, properties inaccessible with standard diffusion measurements. This work expands the capabilities of NMR for probing soft matter, with implications for polymer recycling and materials design.

Fricke, Sophia N. [University of California, Berke↗

Glow-to-arc transition events in H{sub 2}-Ar direct current pulsed plasma: Automated measurement of current and voltage

The glow-to-arc transition phenomena (arcing) observed in plasma reactors used in materials processing was studied through the arcs characteristic current and voltage waveforms. In order to capture these arcs signals, a LABVIEW based automated instrumentation system (ARCVIEW) was developed, including the integration of an oscilloscope equipped with proper current and voltage probes. The system also allows capturing the process parameters at the arc occurrence moments, which were used to map the arcs events conditions. Experiments in H{sub 2}-Ar DC pulsed plasma returned signals data from 215 arcs events, which were analyzed through software routines. According to the results, an anti-arcing system should react in the time order of few microseconds to prevent most of the damage caused by the undesired arcing phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Technique for Barium Daughter Ion Identification in a Liquid Xe-136 Double Beta Decay Experiment

This work addresses long-standing issues of fundamental interest in elementary particle physics. The most important outcome of this work is a new limit on neutrinoless double beta decay. This is an extremely rare and long-sought-after type of radioactive decay. If discovered, it would require changes in the standard model of the elementary constituents of matter, and would prove that neutrinos and antineutrinos are the same, a revolutionary concept in particle physics. Neutrinos are major components of the matter in the universe that are so small and so weakly interacting with other matter that their masses have not yet been discovered. A discovery of neutrinoless double beta decay could help determine the neutrino masses. An important outcome of the work on this project was the Colorado State University role in operating the EXO-200 neutrinoless double beta decay experiment and in analysis of the data from this experiment. One type of double beta decay of the isotope 136 Xe, the two-neutrino variety, was discovered in this work. Although the other type of double beta decay, the neutrinoless variety, was not yet discovered in this work, a world’s best sensitivity of 1.9x10 25 year half-life was obtained. This result rules out a previous claim of a positive result in a different isotope. This work also establishes that the masses of the neutrinos are less than one millionth of that of electrons. A unique EXO-200 analysis, in which the CSU group had a leading role, has established for the first time ever in a liquid noble gas the fraction of daughter atoms from alpha and beta decay that are ionized. This result has important impact on other pending studies, including nucleon decay and barium tagging. Novel additional discoveries include multiphoton ionization of liquid xenon with UV pulsed lasers, which may find application in calibration of future noble liquid detectors, and studies of association and dissociation reactions of Ba + ions in gaseous xenon. Through this project, we are substantially closer to demonstrating “barium tagging”, i.e., detection of single daughter 136 Ba atoms from 136 Xe double beta decay. Milestones achieved include obtaining spectra of small numbers of Ba atoms and cryoprobe advances toward trapping single 136 Ba atoms in solid xenon and probe extraction for detection. One of the other benefits to society is the training of six Ph.D. students in a variety of state-of-the-art technologies, half under primary support of this grant and half with partial support, with four finishing their Ph.D. degrees and two well on their way.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent transfer of nuclear spin polarization in field-cycling NMR experiments

Coherent polarization transfer effects in a coupled spin network have been studied over a wide field range. The transfer mechanism is based on exciting zero-quantum coherences between the nuclear spin states by means of non-adiabatic field jump from high to low magnetic field. Subsequent evolution of these coherences enables conversion of spin order in the system, which is monitored after field jump back to high field. Such processes are most efficient when the spin system passes through an avoided level crossing during the field variation. The polarization transfer effects have been demonstrated for N-acetyl histidine, which has five scalar coupled protons; the initial spin order has been prepared by applying RF-pulses at high magnetic field. The observed oscillatory transfer kinetics is taken as a clear indication of a coherent mechanism; level crossing effects have also been demonstrated. The experimental data are in very good agreement with the theoretical model of coherent polarization transfer. The method suggested is also valid for other types of initial polarization in the spin system, most notably, for spin hyperpolarization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanosecond Mid-Infrared Detection for Pulse Radiolysis

Pulse radiolysis, utilizing electron pulses from accelerators, is the definitive method for adding single positive or negative charges to molecules. It is also among the most effective means for creating free radicals. Such species are particularly important in applications such as redox catalysis relevant to solar energy conversion and advanced nuclear energy systems. Coupled with fast UV-visible detection, pulse radiolysis has become an extremely powerful method for monitoring the kinetics of the subsequent reactions of these species on timescales ranging from picoseconds to seconds. However, in many important contexts the radicals formed are difficult to identify due to their broad and featureless UV-visible absorption spectra. Time-resolved infrared (TRIR) absorption spectroscopy is a powerful structural probe of short-lived intermediates, which allows multiple transient species to be clearly identified and simultaneously monitored in a single process. Unfortunately, due to technical challenges the coupling of fast (sub-millisecond) TRIR with pulse radiolysis has received little attention, being confined to gas-phase studies. Taking advantage of recent developments in mid-IR laser technology, we have recently begun developing nanosecond TRIR detection methodologies for condensed-phase samples at our Laser Electron Accelerator Facility (LEAF). The results of preliminary pulse radiolysis-TRIR investigations on the formation of the one-electron reduced forms of CO{sub 2} reduction catalysts (e.g. see above) and their interactions with CO{sub 2} will be presented.

14 SOLAR ENERGY↗

Time-dependent view of an isotope effect in electron-nuclear nonequilibrium dynamics with applications to N 2

Isotopic fractionation in the photodissociation of N 2 could explain the considerable variation in the 14 N/ 15 N ratio in different regions of our galaxy. We previously proposed that such an isotope effect is due to coupling of photoexcited bound valence and Rydberg electronic states in the frequency range where there is strong state mixing. We here identify features of the role of the mass in the dynamics through a time-dependent quantum-mechanical simulation. The photoexcitation of N 2 is by an ultrashort pulse so that the process has a sharply defined origin in time and so that we can monitor the isolated molecule dynamics in time. An ultrafast pulse is necessarily broad in frequency and spans several excited electronic states. Each excited molecule is therefore not in a given electronic state but in a superposition state. A short time after excitation, there is a fairly sharp onset of a mass-dependent large population transfer when wave packets on two different electronic states in the same molecule overlap. This coherent overlap of the wave packets on different electronic states in the region of strong coupling allows an effective transfer of population that is very mass dependent. The extent of the transfer depends on the product of the populations on the two different electronic states and on their relative phase. It is as if two molecules collide but the process occurs within one molecule, a molecule that is simultaneously in both states. An analytical toy model recovers the (strong) mass and energy dependence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗

Dioctyl ether radiolysis under used nuclear fuel reprocessing conditions: Foundational knowledge for the development of sacrificial ligand grafts

Radiation-induced ligand destruction and concomitant degradation product formation is unavoidable under envisioned used nuclear fuel reprocessing conditions, and ultimately limits the recyclability of a given solvent system formulation. With this in mind, a novel approach to ligand innovation for advanced separations processes is in the design of tailored “protomolecules,” which when exposed to ionizing radiation undergo desired chemical transformations, thereby allowing for a reprocessing solvent system to advantageously evolve with absorbed radiation dose. Here we provide foundational knowledge for the time-resolved (electron pulse) and steady-state (cobalt-60 gamma) radiolytic behavior of dioctyl ether, a protomolecule grafting surrogate. Gamma irradiation of single-phase solutions of dioctyl ether (5–100 vol.%) in n-dodecane resulted in the loss of dioctyl ether (G = -0.72 µmol J –1 ) and the formation of octane (G = 0.11 µmol J –1 ) and octanol (G = 0.15 µmol J –1 ) degradation products, the latter of which is a known reprocessing phase modifier and radioprotectant. Further, these radiation-induced changes were attributed to direct radiation effects, for more concentrated dioctyl ether solutions, and indirect radiation effects, predominantly driven by the reaction of dioctyl ether with the dodecane radical cation, for which we report a second-order rate coefficient of k = (1.53 ± 0.05) × 10 10 L mol –1 s –1 . Under typical biphasic extraction (4.0 mol L –1 HNO 3 ) and strip (0.1 mol L –1 HNO 3 ) reprocessing conditions, gamma irradiation of 5 vol.% dioctyl ether solvent systems afforded negligible change in the rate of parent molecule destruction but promoted significant differences in the radiolytic behavior of its degradation products. These differences are attributed to their respective interactions with [dioctyl ether/HNO 3 /H 2 O] and [octanol/HNO 3 /H 2 O] adducts extracted into the organic phase. Overall, these results support the grafting of ether linkages to advanced separations ligands (e.g., modified diglycolamides).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A tuneable ultra-compact high-power, ultra-short pulsed, bright gamma-ray source based on bremsstrahlung radiation from laser-plasma accelerated electrons

The laser driven plasma wakefield accelerator is a very compact source of high energy electrons. When the quasi-monoenergetic beam from these accelerators passes through dense material, high energy bremsstrahlung photons are emitted in a collimated beam with high flux. We show how a source based on this emission process can produce more than 10{sup 9} photons per pulse with a mean energy of 10 MeV. We present experimental results that show the feasibility of this method of producing high energy photons and compare the experimental results with GEANT4 Montecarlo simulations, which also give the scaling required to evaluate its suitability as method to produce radioisotopes via photo-nuclear reactions or for imaging applications.

07 ISOTOPE AND RADIATION SOURCES↗

Ultrasonic Measurements of Temperature Distribution and Heat Fluxes Across Containments of Extreme Environments

Extreme conditions are common in energy conversion, material processing, nuclear, airspace, and military applications. In such environments, the most hardened insertion sensors do not perform reliably for long. Ultrasonic measurements, on the other hand, can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable in the cases when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. The delays between the echoes, which encode the information on the temperature distribution in the corresponding segments, is used to reconstruct unknown temperature profile. In this paper, we outline the results of pilot-scale testing of the developed approach and demonstrate its application to the measurements of the temperature distribution across the containment of a high-temperature combustion process. The validation results show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Jia, Yunlu↗

Long coherence times in nuclear spin-free vanadyl qubits

Quantum information processing (QIP) offers the potential to create new frontiers in fields ranging from quantum biology to cryptography. Two key figures of merit for electronic spin qubits, the smallest units of QIP, are the coherence time ( T 2 ), the lifetime of the qubit, and the spin–lattice relaxation time (T 1 ), the thermally defined upper limit of T 2 . To achieve QIP, processable qubits with long coherence times are required. Recent studies on (Ph 4 P-d 20 ) 2 [V(C 8 S 8 ) 3 ], a vanadium-based qubit, demonstrate that millisecond T 2 times are achievable in transition metal complexes with nuclear spinfree environments. Applying these principles to vanadyl complexes offers a route to combine the previously established surface compatibility of the flatter vanadyl structures with a long T 2 . Toward those ends, we investigated a series of four qubits, (Ph 4 P) 2 [VO(C 8 S 8 ) 2 ] (1), (Ph 4 P) 2 [VO(β-C 3 S 5 ) 2 ] (2), (Ph 4 P) 2 [VO(α-C 3 S 5 ) 2 ] (3), and (Ph 4 P) 2 [VO(C 3 S 4 O) 2 ] (4), by pulsed electron paramagnetic resonance (EPR) spectroscopy and compared the performance of these species with our recently reported set of vanadium tris(dithiolene) complexes. Crucially we demonstrate that solutions of 1–4 in SO 2 , a uniquely polar nuclear spinfree solvent, reveal T 2 values of up to 152(6) μs, comparable to the best molecular qubit candidates. Upon transitioning to vanadyl species from the tris(dithiolene) analogues, we observe a remarkable order of magnitude increase in T 2 , attributed to stronger solute–solvent interactions with the polar vanadium-oxo moiety. Simultaneously, we detect a small decrease in T 2 for the vanadyl analogues relative to the tris(dithiolene) complexes. We attribute this decrease to the absence of one nuclear spinfree ligand, which served to shield the vanadium centers against solvent nuclear spins. Lastly, our results highlight new design principles for long T 1 and T 2 times by demonstrating the efficacy of ligand-based tuning of solute–solvent interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗