At least 253 records · Page 14

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of turbine driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10 year period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10-year period: The following decreasing trends were identified for TDPs for the most recent 10-year period: • Standby TDP FTR>1H failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands (demands per reactor year) • Normally running TDP frequency of run hours (hours per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP frequency of start demands (demands per reactor year) • Standby MDP frequency of FTR≤1H hours (hours per reactor year) • Standby MDP frequency of FTR>1H hours • Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP FTR≤1H failure probability • Normally running MDP FTR failure rate • Standby MDP unavailability • Normally running MDP total unreliability (8-hour mission) • Standby MDP frequency of FTR≤1H events (failures per reactor year) • Normally running MDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2013

This report presents an enhanced performance evaluation of motor-driven pumps at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2013 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to 1 hour, and failure to run more than 1 hour; for normally running systems, the failure modes considered are failure to start and failure to run. An 8 hr unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. One statistically significant increasing trend was identified in the standby pump run hours per reactor year. Statistically significant decreasing trends were identified for standby systems industry-wide frequency of start demands, run hours per reactor year for runs of less than or equal to 1 hour, and frequency of fail to start events per reactor year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ARC Software Validation Work for the FFTF Reactor

Extensive efforts have been carried out at ANL for the verification and validation of the Argonne Reactor Codes (ARC) software package currently used for the design of Versatile Test Reactor (VTR). The ARC software package consists of steady state neutronics and thermal hydraulics modeling capabilities which are being used by the VTR program to develop most of the VTR reactor design details which will be part of the licensing application. It is anticipated that this software will continue to be used for the design work and for initial operations although additional software may be introduced at a later time. The validation work was focused primarily on obtaining validation data consistent with VTR and usable for the ARC software. Because no critical facilities or operating fast spectrum reactors are available to do experiments for the VTR, the next best option is to identify historical experimental data that can be used as validation data. Early on in VTR, the ZPPR-15 set of experiments was identified as good validation data because of 1) the availability and quality of the data, 2) existing staff that are already familiar with the experimental machine and measurements, 3) most of the ZPPR-15 loadings of interest have already been processed into ARC models, and 4) a full uncertainty quantification has already been done for several loadings of ZPPR-15. The FFTF startup and operations data was identified as the most consistent reactor type that has validation data usable for VTR. Finally, the EBR-II fuel depletion measurements were identified as the best available validation data for VTR. It is important to note that both the FFTF and EBR-II reactors typically come with higher uncertainties than the ZPPR. In the frame of the discussed verification and validation efforts, the present document discusses the analysis of selected FFTF measurements included in the benchmark specifications of the International Reactor Physics Experiment (IRPhE) handbook. The FFTF reactor core configurations from the benchmark specification are presented in Section 2. The analysis is performed with the use of the ARC code suite available at ANL for fast reactor studies and is discussed in Section 3. The reactor parameters from the benchmark include criticality, neutron spectra, effective delayed neutron spectra, control rod worth, isothermal temperature coefficient and low energy gamma-ray spectra. The calculated values and the comparison with the experimental data is discussed in Sections 4 to 9 for each considered reactor parameter. Finally, conclusions are presented in Section 10.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2014

This report presents an enhanced performance evaluation of motor-driven pumps at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified in pump run hours per reactor year. Statistically significant decreasing trends were identified for standby systems industry-wide frequency of start demands, and run hours per reactor year for runs of less than or equal to one hour.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016

This report presents an enhanced performance evaluation of motor-driven pumps (MDP) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2016 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Highly statistically significant increasing trend was identified in normally running MDP run hours per reactor year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A new development on measurement and control software of SANS BATAN spectrometer (SMARTer) in Serpong, Indonesia

In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the SNS superconducting linac and future plan

The use of superconducting radiofrequency (SRF) cavities in particle accelerator is becoming more widespread. Among the projects that make use of that technology is the Spallation Neutron Source, where H- ions are accelerated to about 1 GeV, mostly making use of niobium elliptical cavities. SNS generates neutrons by the spallation reaction with the accelerated short (about 700 ns) sub-bunches of protons, which will in turn allow probing structural and magnetic properties of new and existing materials. The SNS superconducting linac is the largest application of RF superconductivity to come on-line in the last decade and has been operating with beam for almost two years. As the rst operational pulsed superconducting linac, many of the aspects of its performance were unknown and unpredictable. A lot of experiences and data have been gathered on the pulsed behavior of cavities and cryomodules at various repetition rates and at various temperatures during the commissioning of its components and beam operations. This experience is of great value in determining future optimizations of SNS as well in guiding in the design and operation of future pulsed superconducting linacs. The testing of the superconducting cavities, the operating experience with beam, the performance of the superconducting linac and the future plans will be presented.

43 PARTICLE ACCELERATORS↗

Time-critical database condition data handling in the CMS experiment during the first data taking period

Automatic, synchronous and reliable population of the condition databases is critical for the correct operation of the online selection as well as of the offline reconstruction and analysis of data. In this complex infrastructure, monitoring and fast detection of errors is a very challenging task. In this paper, we describe the CMS experiment system to process and populate the Condition Databases and make condition data promptly available both online for the high-level trigger and offline for reconstruction. The data are automatically collected using centralized jobs or are 'dropped' by the users in dedicated services (offline and online drop-box), which synchronize them and take care of writing them into the online database. Then they are automatically streamed to the offline database, and thus are immediately accessible offline worldwide. The condition data are managed by different users using a wide range of applications.In normal operation the database monitor is used to provide simple timing information and the history of all transactions for all database accounts, and in the case of faults it is used to return simple error messages and more complete debugging information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Storage Systems for Data Intensive Computing

In this chapter, the authors present an overview of the utility of distributed storage systems in supporting modern applications that are increasingly becoming data intensive. Their coverage of distributed storage systems is based on the requirements imposed by data intensive computing and not a mere summary of storage systems. To this end, they delve into several aspects of supporting data-intensive analysis, such as data staging, offloading, checkpointing, and end-user access to terabytes of data, and illustrate the use of novel techniques and methodologies for realizing distributed storage systems therein. The data deluge from scientific experiments, observations, and simulations is affecting all of the aforementioned day-to-day operations in data-intensive computing. Modern distributed storage systems employ techniques that can help improve application performance, alleviate I/O bandwidth bottleneck, mask failures, and improve data availability. They present key guiding principles involved in the construction of such storage systems, associated tradeoffs, design, and architecture, all with an eye toward addressing challenges of data-intensive scientific applications. They highlight the concepts involved using several case studies of state-of-the-art storage systems that are currently available in the data-intensive computing landscape.

99 GENERAL AND MISCELLANEOUS↗

AGR-1 Compact 5-3-1 Post-Irradiation Examination Results

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program was established to perform the requisite research and development on tristructural isotropic (TRISO) coated particle fuel to support deployment of a high-temperature gas-cooled reactor (HTGR). The work continues as part of the Advanced Reactor Technologies (ART) TRISO Fuel program. The overarching program goal is to provide a baseline fuel qualification data set to support licensing and operation of an HTGR. To achieve these goals, the program includes the elements of fuel fabrication, irradiation, post-irradiation examination (PIE) and safety testing, fuel performance, and fission product transport (INL 2015). A series of fuel irradiation experiments is being planned and conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). These experiments will provide data on fuel performance under irradiation, support fuel process development, qualify the fuel for normal operating conditions, provide irradiated fuel for safety testing, and support the development of fuel performance and fission product transport models. The first of these irradiation tests, designated AGR-1, began in the ATR in December 2006 and ended in November 2009. This experiment was conducted primarily to act as a shakedown test of the multicapsule test train design and provide early data on fuel performance for use in fuel fabrication process development. It also provided samples for post-irradiation safety testing, where fission product retention of the fuel at high temperatures will be experimentally measured. The capsule design and details of the AGR-1 experiment have been presented previously.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Loss-of-Offsite-Power Events: 1987-2016

Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1987 through 2016. LOOP events during critical operation that do not result in a reactor trip are not included. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. Emergency diesel generator reliability is also considered (failure to start, failure to load and run, and failure to run more than 1 hour). An adverse trend in overall LOOP frequency is identified. An adverse trend in LOOP durations is identified. Plant-centered and weather-related LOOP events do not show statistically significant seasonality. The engineering analysis of LOOP data shows that human errors have been much less frequent since 1997 than in the 1986–1996 time period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Model of the AGR-5/6/7 Experiment

Several fuel and material irradiation experiments have been planned for the U.S. Department of Energy Advanced Gas Reactor Fuel Development and Qualification Program, which supports the development and qualification of tristructural isotropic (TRISO) coated particle fuel for use in high-temperature gas-cooled reactors. The goals of these experiments are to provide irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, support development of fuel performance models and codes, and provide irradiated fuel and materials for post-irradiation examination and safety testing. Originally planned and named as separate fuel experiments, but subsequently combined into a single test train, AGR-5/6/7 will test low-enriched uranium oxycarbide (UCO – a heterogeneous mixture of uranium oxide and uranium carbide) TRISO fuel. The AGR-5/6 portion of the experiment will provide data to support qualification of the selected reference fuel design, while the AGR-7 portion will serve as a margin test, irradiating the fuel beyond normal operating conditions. A thermal finite element model has been created for the five capsules comprising the AGR-5/6/7 experiment. Heat rates from a physics analysis are imported into the model along with fast neutron fluence. Graphite shrinkage due to the fast neutron fluence is incorporated into the model. Gas gaps change as a function of fast neutron fluence. Radiation heat transfer is a major contributor in this model. This is a large model with more than 1 million finite element brick elements. More than 150 different parts are modeled in the finite element model and communicate with each other from a heat transfer sense. More than 50 thermocouples are used in the experiment and are compared to actual measurements. The experiment is composed of five separate stainless steel capsules all welded together. Each capsule has its own Helium/.Neon gas mixture to help control the temperature of the capsule.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-1 Compact 1-3-1 Post-Irradiation Examination Results

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program was established to perform the requisite research and development on tristructural isotropic (TRISO) coated particle fuel to support deployment of a high-temperature gas-cooled reactor (HTGR). The work continues as part of the Advanced Reactor Technologies (ART) TRISO Fuel program. The overarching program goal is to provide a baseline fuel qualification data set to support licensing and operation of an HTGR. To achieve these goals, the program includes the elements of fuel fabrication, irradiation, post-irradiation examination (PIE) and safety testing, fuel performance modeling, and fission product transport (INL 2015). A series of fuel irradiation experiments is being planned and conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). These experiments will provide data on fuel performance under irradiation, support fuel process development, qualify the fuel for normal operating conditions, provide irradiated fuel for safety testing, and support the development of fuel performance and fission product transport models. The first of these irradiation tests, designated AGR-1, began in the ATR in December 2006 and ended in November 2009. This experiment was conducted primarily to act as a shakedown test of the multicapsule test train design and provide early data on fuel performance for use in fuel fabrication process development. It also provided samples for post-irradiation safety testing, where fission product retention of the fuel at high temperatures will be experimentally measured. The capsule design and details of the AGR-1 experiment have been presented previously (Grover, Petti, and Maki 2010, Maki 2009).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Abstract for CRADA between the National Energy Technology Laboratory and Strategic Power Systems, Inc. (AGMT-0884)

This project will utilize field data, available through the Operational Reliability Analysis Program (ORAP®), to assess the operation of natural gas combined cycle (NGCC) and coal fired plants in cyclic duty. The emphasis will be on Heat Recovery Steam Generator (HRSG) and coal-fired boiler operating conditions and failure experience related to tube failures. The project will be based on high-fidelity data available in ORAP through the collection of near real time process data characterizing the operating environment and dynamic conditions, from start up to shut-down, that affect the HRSG and coal-fired boiler (i.e. the boiler tubes). It is important to understand the operating environment to assess the influence of the cyclic start-stop cycles, time at temperature, and other operating conditions that can be seen in the data, with their possible impact on the life and reparability of the boiler tubes. This knowledge is important to influence/develop a predictive operations and maintenance strategy to improve performance, increase life, and reduce cost.

20 FOSSIL-FUELED POWER PLANTS↗

Continuing the Operation of EXO-200 at WIPP

This grant supported, in part, the operations of the EXO-200 double beta decay experiment at the Waste Isolation Pilot Plant (WIPP) for the period May 1, 2013 to Sept 30, 2015. In this period EXO-200 completed its first phase of data taking, although its operation was disrupted in Feb 2014 by the accidents at WIPP (unrelated to the experiment). The primary goal of the experiment is to search for the very rate (and to date not observed) neutrino-less double beta decay. Such decay, if observed, would shed the light of the quantum-mechanical structure of neutrinos, and the origins of elementary particle masses. Another goal of the detector is to serve as prototype of a larger neutrino-less double beta decay experiment, currently being considered by DOE-OS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗