Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

AVIRIS Inflight Calibration Experiments, Analysis, and Results in 2000

The NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectra from 370 to 2500 nm with nominally 10-nm sampling and resolution. The spectra are acquired as images with an 11 km width and up to 800 km length from the ER-2 platform or 2.1 km width and 160 km length from the Twin Otter platform. AVIRIS measurements are used for a range of Earth science research and application objectives. The molecular absorption and particle scattering properties expressed in the calibrated AVIRIS measurements are used. For both science research and application objectives, calibration of the AVIRIS spectra is required to produce useful results. Each year prior to the flight season AVIRIS is calibrated in the laboratory. However, the temperature, pressure, vibration, and observational geometry, as well as mechanical, electrical, and operational interfaces of the laboratory are different than the environment on board the airborne platform. To validate the calibration of AVIRIS in the flight environment, an inflight calibration experiment is orchestrated at the beginning of each flight season. In most years additional inflight calibration experiments occur towards the middle and end of the flight season as well. For an inflight calibration experiment, AVIRIS acquires airborne data over a designated calibration target. In concert with the airborne data acquisition, surface and atmospheric properties at the calibration target are measured in situ. These in situ measurements are used to constrain a radiative transfer code and predict the radiance incident at the AVIRIS instrument from the calibration target. This prediction is compared with the AVIRIS-measured radiance to validate the calibration of AVIRIS in the flight environment. Additional properties (such as the AVIRIS inflight measurement precision) are determined as well. This paper presents measurements, analyses, and results from the inflight calibration experiment held on the dry lake bed surface of Rogers Dry Lake, California, on June 5, 2000.

Green, Robert O.↗

Assessment of the Visible Channel Calibrations of the TRMM VIRS and MODIS on Aqua and Terra

Several recent research satellites carry self-calibrating multispectral imagers that can be used for calibrating operational imagers lacking complete self-calibrating capabilities. In particular, the visible (VIS, 0.65 m) channels on operational meteorological satellites are generally calibrated before launch, but require vicarious calibration techniques to monitor the gains and offsets once they are in orbit. To ensure that the self-calibrating instruments are performing as expected, this paper examines the consistencies between the VIS channel (channel 1) reflectances of the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on the Terra and Aqua satellites and the Version 5a and 6 reflectances of the Visible Infrared Scanner (VIRS) on the Tropical Rainfall Measuring Mission using a variety of techniques. These include comparisons of Terra and Aqua VIS radiances with coincident broadband shortwave radiances from the well-calibrated Clouds and the Earth s Radiant Energy System (CERES), time series of deep convective cloud (DCC) albedos, and ray-matching intercalibrations between each of the three satellites. Time series of matched Terra and VIRS data, Aqua and VIRS data, and DCC reflected fluxes reveal that an older version (Version 5a, ending in early 2004) of the VIRS calibration produced a highly stable record, while the latest version (Version 6) appears to overestimate the sensor gain change by approx.1%/y as the result of a manually induced gain adjustment. Comparisons with the CERES shortwave radiances unearthed a sudden change in the Terra MODIS calibration that caused a 1.17% decrease in the gain on 19 November 2003 that can be easily reversed. After correction for these manual adjustments, the trends in the VIRS and Terra channels are no greater than 0.1%/y. Although the results were more ambiguous, no statistically significant trends were found in the Aqua MODIS channel-1 gain. The Aqua radiances are 1% greater, on average, than their Terra counterparts, and after normalization are 4.6% greater than VIRS radiances, in agreement with theoretical calculations. The discrepancy between the two MODIS instruments should be taken into account to ensure consistency between parameters derived from them. With the adjustments, any of the three instruments can serve as references for calibrating other satellites. Monitoring of the calibrations continues in near-real-time and the results are available via the world wide web.

Minnis, Patrick↗

GOME Calibration and Validation Using Backscatter UV Techniques

GOME radiance, irradiance, and ozone products were validated by NASA Goddard Space Flight Center through three tasks which included, pre-launch calibration comparisons with SBUV and TOMS radiometric standards, validation of GOME Level-1 irradiance and radiance and Level 2 total ozone data products using SBUV/2 and TOMS algorithms and data, and studies of GOME data using the Goddard radiative transfer code. The prelaunch calibration using the NASA large aperture integrating sphere was checked against that provided by TPD. Agreement in the calibration constants, derived in air, between the Goddard and TPD system were better than 3%. Validation of Level-1 irradiance data included comparison of GOME and SSBUV and the UARS solar irradiances measurements. Large wavelength dependent differences, as high as 10%, were noted between GOME and the US instruments. This discrepancy has now been attributed to radiometric sensitivity changes experienced by GOME when operating in a vacuum. GOME Earth radiance data were then compared to the NOAA-14 SBUV/2 radiances. These results show that between 340 and 400 nm the differences in GOME and SBUV/2 data are less than 5% with some wavelength dependence. At wavelengths shorter than 300 nm, differences are of the order of 10% or more where the GOME radiances are larger. To test GOME DOAS retrieved total ozone values, these values were compared with ozone amounts retrieved using GOME radiances in the TOMS version-7 algorithm. The differences showed a solar zenith angle dependence ranging from 0 to 10% where the TOMS algorithm values were higher. GOME radiances below 300 nm were further validated by selecting radiances at wavelengths normally used by SBUV and processing them through the SBUV ozone profile algorithm and then compared to climatological values. The GOME ozone profiles ranged from 10-30% lower over altitude compared to climatological values. This is consistent with the offsets detected in the SBUV/2 radiance comparisons at wavelengths shorter than 300 nm.

Hilsenrath, E.↗

Cloud Shortwave Optical Properties

The data set consists of calibrated zenith shortwave spectral radiances (400-950 nm and 940-1665 nm) and cloud optical depth (COD) retrievals every 2 seconds. The field of view is 0.5 degree. Retrievals of cloud droplet effective radius and thermodynamic phase are currently experimental and done offline. Effective radius and phase are not in this data set.

54 ENVIRONMENTAL SCIENCES↗

TWST Cloud Properties (COD, droplet effective radius, and thermodynamic phase). SAIL, AMF2, 2022-2023.

The dataset consists of calibrated zenith shortwave spectral radiances (440-1700 nm) and cloud optical depth (COD) retrievals approximately every second. Retrievals of cloud droplet effective radius and thermodynamic phase are currently done offline, but some of these retrievals are included in the dataset. Effective radius and phase are included for days with periods of sufficiently high COD. Effective radius and phase retrievals in the data set were computed at approximately 5-10 second intervals to reduce computation time. The retrievals can be performed at the full sample rate. The field of view is 0.5 degree.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Geologic/spectral Analysis of LANDSAT-4 Thematic Mapper Data, Wind River/bighorn Basin Area, Wyoming

A LIDQA evaluation for geologic applications of a LANDSAT TM scene covering the Wind River/Bighorn Basin area, Wyoming, is examined. This involves a quantitative assessment of data quality including spatial and spectral characteristics. Analysis is concentrated on the 6 visible, near infrared, and short wavelength infrared bands. Preliminary analysis demonstrates that: (1) principal component images derived from the correlation matrix provide the most useful geologic information. To extract surface spectral reflectance, the TM radiance data must be calibrated. Scatterplots demonstrate that TM data can be calibrated and sensor response is essentially linear. Low instrumental offset and gain settings result in spectral data that do not utilize the full dynamic range of the TM system.

Lang, H. R.↗

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Predicted Diurnal Variability - 1

Laboratory calibration and observed background radiance data are used to determine the effective sensitivities of the Optical Transient Detector and Lightning Imaging Sensor, as functions of local hour and pixel location within the instrument arrays. The effective LIS thresholds, expressed as radiances emitted normal to cloud top, are 4.0 plus or minus 0.7 and 7.6 plus or minus 3.3 micro J/ster/m (sup 2) for night and local noon; the OTD thresholds am 11.7 plus or minus 2.2 and 16.8 plus or minus 4.6 microJ/ster/m (sup 2). LIS and OTD minimum signal to noise ratios occur from 0800 to 1600 local time, and attain values of 10 plus or minus 2 and 20 plus or minus 3, respectively. False alarm rate due to instrument noise yields approximately 5 false triggers per month for LIS, and is negligible for OTD. Flash detection efficiency, based on prior optical pulse sensor measurements, is predicted to be 93 plus or minus 4% and 73 plus or minus 11% for LIS night and noon; 56 plus or minus 7% and 44 plus or minus 9% for OTD night and noon, corresponding to a 12 - 20% diurnal variability and LIS:OTD ratio of 1.7. Use of the weighted daily mean detection efficiency (i.e., not controlling for local hour) corresponds to a sigma = 8 - 9% uncertainty. These are likely overestimates of actual flash detection efficiency due to differences in pixel ground field-of-view across the instrument arrays, which are not accounted for in the validation optical pulse sensor data.

Boccippio, Dennis J.↗

Numerical Filtering of Spurious Transients in a Satellite Scanning Radiometer: Application to CERES

The Clouds and Earth Radiant Energy System (CERES) scanning, radiometer was designed to provide high accuracy measurements of the radiances from the earth. Calibration testing of the instruments showed the presence of all undesired slow transient in the measurements of all channels at 1% to 2% of the signal. Analysis of the data showed that the transient consists of a single linear mode. The characteristic time of this mode is 0.3 to 0.4 s and is much greater than that the 8-10-ms response time of the detector, so that it is well separated from the detector response. A numerical filter was designed for the removal of this transient from the measurements. Results show no trace remaining of the transient after application of the numerical filter. The characterization of the slow mode on the basis of ground calibration data is discussed and flight results are shown for the CERES instruments aboard the Tropical Rainfall Measurement Mission and Terra spacecraft. The primary influence of the slow mode is in the calibration of the instrument and the in-flight validation of the calibration. This method may be applicable to other radiometers that are striving for high accuracy and encounter a slow spurious mode regardless of the underlying physics.

Smith, G. Louis↗

Recent Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS)

Several improvements have been made to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS) since 1994--new focal plane arrays, a new analog and digital chain and an onboard calibration lamp controlled by radiance feedback. These changes increased the signal-to- noise ratio by 2 to 3 times, eliminated noise spikes and the need for spectral sampling, and greatly reduced dark-current noise.

AVRIS improvements spectrometer↗

Investigating the Use of Deep Convective Clouds (DCCT) to Monitor On-orbit Performance of the Geostationary Lightning Mapper (GLM) using Lightning Imaging Sensor (LIS) Measurements

There is a need to monitor the on-orbit performance of the Geostationary Lightning Mapper (GLM) on the Geostationary Operational Environmental Satellite R (GOES-R) for changes in instrument calibration that will affect GLM's lightning detection efficiency. GLM has no onboard calibration so GLM background radiance observations (available every 2.5 min) of Deep Convective Clouds (DCCs) are investigated as invariant targets to monitor GLM performance. Observations from the Lightning Imaging Sensor (LIS) and the Visible and Infrared Scanner (VIRS) onboard the Tropical Rainfall Measuring Mission (TRMM) satellite are used as proxy datasets for GLM and ABI 11 m measurements.

Buechler, Dennis E.↗

Evaluation of the Radiometric Integrity of LANDSAT-4 Thematic Mapper Band 6 Data

An approach for experimentally evaluating the radiometric calibration of the LANDSAT-4 band 6 data is described which draws on a method used to radiometrically calibrate the HCMR data which involved underflying the satellite with an infrared line scanner. By extending this technology to higher altitudes experimental radiance data suitable for radiometric calibration of the TM band 6 sensor can be generated. Repetition of this experiment can permit evaluation of long term drift in the sensor and provide a data base for evaluating atmospheric propagation models for radiation transfer. To date, efforts were concentrated on modifying the infrared line scanner to match the spectral response of the TM band 6 sensor. In addition, the LOWTRAN code corresponding to a satellite overpass of September 1982 was run to yield a plot of transmission and path radiance as a function of altitude.

Schott, J. R.↗

The Precision and Accuracy of AIRS Level 1B Radiances for Climate Studies

We investigate uncertainties in the Atmospheric Infrared Sounder (AIRS) radiances based on in-flight and preflight calibration algorithms and observations. The global coverage and spectra1 resolution ((lamda)/(Delta)(lamda) ~ 1200) of AIRS enable it to produce a data set that can be used as a climate data record over the lifetime of the instrument. Therefore, we examine the effects of the uncertainties in the calibration and the detector stability on future climate studies. The uncertainties of the parameters that go into the AIRS radiometric calibration are propagated to estimate the accuracy of the radiances and any climate data record created from AIRS measurements. The calculated radiance uncertainties are consistent with observations. Algorithm enhancements may be able to reduce the radiance uncertainties by as much as 7%. We find that the orbital variation of the gain contributes a brightness temperature bias of < 0.01 K.

climate↗

Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 2: Analysis of the ERBE integrating sphere ground calibration

An explicit solution of the spectral radiance leaving an arbitrary point on the wall of a spherical cavity with diffuse reflectivity is obtained. The solution is applicable to spheres with an arbitrary number of openings of any size and shape, an arbitrary number of light sources with possible non-diffuse characteristics, a non-uniform sphere wall temperature distribution, non-uniform and non-diffuse sphere wall emissivity and non-uniform but diffuse sphere wall spectral reflectivity. A general measurement equation describing the output of a sensor with a given field of view, angular and spectral response measuring the sphere output is obtained. The results are applied to the Earth Radiation Budget Experiment (ERBE) integrating sphere. The sphere wall radiance uniformity, loading effects and non-uniform wall temperature effects are investigated. It is shown that using appropriate interpretation and processing, a high-accuracy short-wave calibration of the ERBE sensors can be achieved.

Halyo, Nesim↗

Error Budget for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

A goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to observe highaccuracy, long-term climate change trends over decadal time scales. The key to such a goal is to improving the accuracy of SI traceable absolute calibration across infrared and reflected solar wavelengths allowing climate change to be separated from the limit of natural variability. The advances required to reach on-orbit absolute accuracy to allow climate change observations to survive data gaps exist at NIST in the laboratory, but still need demonstration that the advances can move successfully from to NASA and/or instrument vendor capabilities for spaceborne instruments. The current work describes the radiometric calibration error budget for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The resulting SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climatequality data collections is given. Key components in the error budget are geometry differences between the solar and earth views, knowledge of attenuator behavior when viewing the sun, and sensor behavior such as detector linearity and noise behavior. Methods for demonstrating this error budget are also presented.

radiometric calibration↗

Cross-calibration of Imaging Sensors using Model-based, SI-traceable Predictions of At-sensor Radiance

Many inter-consistency efforts force empirical agreement between sensors viewing a source nearly coincident in time and geometry that ensures consistency between sensors rather than obtain an SI-traceable calibration with documented error budgets. The method described here provides interconsistency via absolute radiometric calibration with defensible error budget avoiding systematic errors through prediction of at-sensor radiance for a site viewed by multiple sensors but not necessarily viewed at coincident times. The method predicts spectral radiance over a given surface site for arbitrary view and illumination angles and for any date dominated by clear-sky conditions. The foundation is a model-based, SI-traceable prediction of at-sensor radiance over selected sites based on physical understanding of the surface and atmosphere. The calibration of the ground site will include spatial, spectral, and sunview geometric effects based on satellite and ground-based data. The result is an interconsistency of hyperspectral and multispectral sensors spanning spatial resolutions from meters to kilometers all relative to the surface site rather than a single sensor. The source-centric philosophy of calibrating the site inherently accounts for footprint size mismatch, spectral band mismatch, and temporal and spatial sampling effects. The method for characterizing the test site allows its use for SI-traceable calibration of any sensor that can view the calibrated test site. Interconsistency is obtained through the traceability and error budget rather than coincident views. Such an approach to inter-consistency provides better understanding of biases between sensors as well producing more accurate results with documented SI-traceability that reduces the need for overlapping data sets.

Thome, Kurtis↗

Lessons Learned from the AIRS Pre-Flight Radiometric Calibration

The Atmospheric Infrared Sounder (AIRS) instrument flies on the NASA Aqua satellite and measures the upwelling hyperspectral earth radiance in the spectral range of 3.7-15.4 micron with a nominal ground resolution at nadir of 13.5 km. The AIRS spectra are achieved using a temperature controlled grating spectrometer and HgCdTe infrared linear arrays providing 2378 channels with a nominal spectral resolution of approximately 1200. The AIRS pre-flight tests that impact the radiometric calibration include a full system radiometric response (linearity), polarization response, and response vs scan angle (RVS). We re-derive the AIRS instrument radiometric calibration coefficients from the pre-flight polarization measurements, the response vs scan (RVS) angle tests as well as the linearity tests, and a recent lunar roll test that allowed the AIRS to view the moon. The data and method for deriving the coefficients is discussed in detail and the resulting values compared amongst the different tests. Finally, we examine the residual errors in the reconstruction of the external calibrator blackbody radiances and the efficacy of a new radiometric uncertainty model. Results show the radiometric calibration of AIRS to be excellent and the radiometric uncertainty model does a reasonable job of characterizing the errors.

Sounder↗