Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Access to uncombined titanium through an inhibiting film in sublimation pumping of deuterium.

In principle, titanium bulk sublimator pumping should be ideal for removing large quantities of deuterium from a vacuum system. In practice, much of the deposited titanium remains uncombined and is wasted. We have demonstrated, through a series of experiments, that it is possible (by the addition of a thin layer of titanium to an apparently occluded surface) to gain access to previously deposited sublayers of uncombined titanium in spite of the presence of an inhibiting film (such as an oxide) on the surface.

Steinberg, R.↗

Dissociative excitation of molecular hydrogen by electron impact.

A pulsed electron beam was employed in the experiment to excite a diffuse gas of hydrogen molecules. The energy resolution of the electron gun permitted careful measurements of the thresholds for the production of slow and fast H(2s) atoms. The experiment was conducted in a vacuum system that facilitated a systematic study of the angular distribution of the fragments in the dissociative excitation process. The results permit the identification of the several excited states that are involved in the production of the H(2s) fragments.

Misakian, M.↗

Long life neutron generator target using deuterium pass-through structure

Target structure permits all deuterons, except the one-in-a-million that interacts with tritium atom to produce a neutron, to pass completely through target structure and be returned to vacuum system. Since tritium atoms are not displaced as in conventional targets, tritium population will remain unchanged while under deuteron bombardment.

Alger, D. L.↗

Development study of the X-ray scattering properties of a group of optically polished flat samples

A group of twelve optically polished flat samples were used to study the scattering of X-rays. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering measurements were made at 8.34A and 0.92 deg angle of incidence. The results for ten of the samples are comparable, the two exceptions being the fire polished samples.

Froechtenigt, J. F.↗

Development of sputtered techniques for thrust chambers, task 1

Filler materials proposed for use in the sputter fabrication regeneratively cooled thrust chambers were evaluated. Low melting castable alloys, CERROBEND. CERROCAST, and CERROTRU, slurry applied SERMETEL 481 and flame-sprayed aluminum were investigated as filler materials. Sputter deposition from a cylindrical cathode inverted magnestron was used to apply an OFHC copper closeout layer to filled OFHC copper ribbed-wall cylindrical substrates. The sputtered closeout layer structure was evaluated with respect to filler material contamination, predeposition machining and finishing operations, and deposition parameters. The application of aluminum by flame-spraying resulted in excessiver filler porosity. Though the outgassing from this porosity was found to be detrimental to the closeout layer structure, bond strengths in excess of 10,500 psi were achieved. Removal of the aluminum from the grooves was readily accomplished by leaching in a 7.0 molar solution of sodium hydroxide at 353 K. Of the other filler materials evaluated, CERROTRU was found to be the most suitable material with respect to completely filling the ribbed-wall cylinders and vacuum system compatibility. However, bond contamination resulted in low closeout layer bond strength with the CERROTRU filler. CERROBEND, CERROCAST, and SERMETEL 481 were found to be unacceptable as filler materials.

Mullaly, J. R.↗

A study of stratospheric gases catalytically reacting on alumina

A vacuum system developed to study stratospheric gases reacting on Al2O3. Special attention was given to the reactions of HCl, SO2, and O3. Efforts were made to detect atoms and/or molecules produced by catalytic action of Al2O3 with mass spectrometer.

Cox, J. L., Jr.↗

Effect of entry-lip design on aerodynamics and acoustics of high throat Mach number inlets for the quiet, clean, short-haul experimental engine

Results of scale model tests of high-throat-Mach-number inlets designed to suppress inlet-emitted engine machinery noise produced in a V/STOL wind tunnel are presented. A vacuum system was used to induce inlet airflow with a siren as a noise source. Inlet mass flow was 11.68 kilograms (25.75 lb. min) per second at a throat Mach number of 0.79. The effect of entry-lip design (contraction ratio and diameter ratio) on inlet total-pressure recovery, steady-state pressure distortion, performance at high incidence angles, and noise suppression was determined. With proper entry-lip design, total-pressure recovery in excess of 0.988 could be obtained statically at an average throat Mach number of 0.79. Total-pressure distortion was 5 percent. The reduction in the siren tone sound pressure level transmitted through the inlet was 10 to 14 db relative to that measured at throat Mach 0.6.

Miller, B. A.↗

Investigation of problems associated with solid encapsulation of high voltage electronic assemblies; also Reynolds connector study

Electric breakdown prevention in vacuum and encapsulation of high voltage electronic circuits was studied. The lap shear method was used to measure adhesive strengths. The permeation constants of air at ambient room temperature through four different space-grade encapsulants was measured. Order of magnitude was calculated for the time that air bubble pressures drop to the corona region. High voltage connectors with L-type cable attached were tested in a vacuum system at various pressures. The cable system was shown to suppress catastrophic breakdown when filled with and surrounded by gas in the corona region of pressures, but did not prove to be completely noise free.

Bever, R. S.↗

Multispecies transient simulator

Computer program predicts transient pressure variation of multispecies gases in large vacuum systems composed of interconnecting compartments.

Lee, A. L.↗

Vacuum considerations in the design of a space simulator

Vacuum considerations in the techniques for design, fabrication, and testing of space simulators are discussed. Particular emphasis is given to a diffusion pump-rotary pump combination for the vacuum system.

Ramachandran, S.↗

Silicon Schottky photovoltaic diodes for solar energy conversion

Various factors in Schottky barrier solar cell fabrication are evaluated in order to improve understanding of the current flow mechanism and to isolate processing variables that improve efficiency. Results of finger design, substrate resistivity, surface finishing and activation energy studies are detailed. An increased fill factor was obtained by baking of the vacuum system to remove moisture.

Anderson, W. A.↗

Fluid handling equipment: A compilation

Devices and techniques used in fluid-handling and vacuum systems are described. Section 1 presents several articles on fluid lines and tubing. Section 2 describes a number of components such as valves, filters, and regulators. The last section contains descriptions of a number of innovative fluid-handling systems.

Source record↗

Exoelectron emission from a clean, annealed magnesium single crystal during oxygen adsorption

Exoelectron emission was observed from a clean, annealed Mg (0001) surface during oxygen and chlorine adsorption at pressures of 6.5x10 0.00001- N/sq m and lower. the studies were performed in an ultrahigh vacuum system. The crystals were cleaned by argon ion bombardment and annealed at 300 C. Auger electron spectroscopy was used to verify surface cleanliness, and low energy electron diffraction was used to verify that the surface was annealed. The emission was found to be oxygen arrival rate dependent. Two peaks were observed in the electron emission with exposure. Evidence is presented that the formation of the second peak corresponds to oxidation of the Mg surface. No emission was observed from clean aluminum during adsorption. Results verify that electron emission occurs from a strain free surface simply upon adsorption of oxygen. A qualitative explanation for the mechanisms of emission in terms of chemical effects is presented.

Ferrante, J.↗

Tenth Aerospace Mechanisms Symposium

Design studies and analyses were performed to describe the loads and dynamics of the space shuttle tail service masts. Of particular interest is the motion and interaction of the umbilical carrier plate, lanyard system, vacuum jacketed hoses, latches, links, and masthead.

Source record↗

Space Shuttle Tail Service Mast Concept Verification

Design studies and analyses were performed to describe the loads and dynamics of the space shuttle tail service masts (TSMs). Of particular interest are the motion and interaction of the umbilical carrier plate, lanyard system, vacuum jacketed hoses, latches, links, and masthead. A development test rig was designed and fabricated to obtain experimental data. The test program is designed to (1) verify the theoretical dynamics calculations, (2) prove the soundness of design concepts, and (3) elucidate problem areas (if any) in the design of mechanisms and structural components. Design, fabrication, and initiation of TSM development testing at Kennedy Space Center are described.

Uda, R. T.↗

Exoelectron emission from a clean, annealed magnesium single crystal during oxygen adsorption

Exoelectron emission has been observed from a clean, annealed Mg (0001) surface during oxygen and chlorine adsorption at pressures of 0.000065 N/sq m and lower. The studies were performed in an ultrahigh vacuum system. The crystals were cleaned by argon-ion bombardment and annealed at 300 C. Auger electron spectroscopy was used to verify surface cleanliness, and low-energy electron diffraction was used to verify that the surface was annealed. The emission was found to be dependent on oxygen arrival rate. Two peaks were observed in the electron emission with exposure. Evidence is presented that the formation of the second peak corresponds to oxidation of the Mg surface. The results verify that electron emission occurs from a strain-free surface simply upon adsorption of oxygen. A qualitative explanation for the mechanisms of emission in terms of chemical effects is presented.

Ferrante, J.↗

An investigation of accelerating mode and decelerating mode constant-momentum mass spectrometry and their application to a residual gas analyzer

A theoretical analysis of constant momentum mass spectrometry was made. A maximum resolving power for the decelerating mode constant momentum mass spectrometer was shown theoretically to exist for a beam of ions of known energy. A vacuum system and an electron beam ionization source was constructed. Supporting electronics for a residual gas analyzer were built. Experimental investigations of various types of accelerating and decelerating impulsive modes of a constant momentum mass spectrometer as applied to a residual gas analyzer were made. The data indicate that the resolving power for the decelerating mode is comparable to that of the accelerating mode.

Ng, Y. S.↗

Electron beam irradiation of thinned backside illuminated CCDs

The physical properties of backside illuminated surface channel CCD arrays and a pixel buried channel CCD array when bombarded with electrons were studied. The devices were mounted in a high vacuum system and irradiated with electrons generated by an electron gun. Basic measurements of EBS gain, dead voltage, transfer efficiency and dark current were performed to verify proper device operation. The surface channel devices were then irradiated with electrons of up to 8 keV energy for up to 98 hours while the buried channel device was irradiated with electrons.

Borsuk, G. M.↗