Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Laboratory-Scale Coal-Derived Graphene Process (Final Report)

The Energy & Environmental Research Center (EERC) conducted a laboratory-scale coal-derived graphene (CDG) project focused on developing a technological process for making graphene from four U.S. domestic coal or coal wastes, including lignite from North Dakota, subbituminous coal from Wyoming, bituminous coal from Utah, and anthracite from Pennsylvania. The project was divided into two performance or budget periods (BPs), with BP1 comprising the up-front laboratory experiments to make graphene materials from coal beginning on May 1, 2020, to April 30, 2022. BP2 was conducted from May 1, 2022, to April 30, 2023, and was focused on analyzing the CDG process economic feasibility and the technical gaps for technological scale-up and commercialization. During this project, a few different coal-derived high-value products have been demonstrated, including graphite, graphene oxide (GO), reduced graphene oxide (rGO), and graphene quantum dots (GQDs). A new graphite microstructure was discovered and named “croissant graphite” because of the exterior morphological and textural resemblance to croissant food items sold in commercial groceries stores. The new graphite structure and the associated preparation from coal or coal waste feedstocks has been the subject of a U.S. patent application. The systematic experimental processes involving coal cleaning, upgrading, and conversion to high-value carbon products culminated into a developed upgraded coal-to-products (UCP) technology that is being pursued for potential fast-track commercialization, if funding is available. It is envisioned that commercialization of the UCP technology would increase consumption of U.S. domestic coals or coal wastes to make environmentally sustainable high-value products for the electronics industry, high-energy-storage applications, and clean energy technologies such as electric vehicle (EV) lithium-ion batteries (LIBs), for which graphite has become a critical mineral commodity. Croissant graphite microstructures, when observed by field emission scanning electron microscopy (FESEM), display wavy surface morphology and often grow from a base that is made of graphitized particles with honeycomb-like layers, which are believed to be graphene layers. While more studies are needed to fully ascertain the mechanisms of the croissant graphite microstructure formation, it is postulated that their growth may begin from curling of the graphene sheets into ribbon-like structures, and continuous growth and densification of the ribbon-like structures forms croissant microstructures. Additional studies are ongoing to evaluate the electrochemical performance of croissant graphite for LIB applications and to determine the experimental conditions necessary to tune on/off croissant formation so that it can be either optimized or suppressed depending on performance evaluation results. In addition to the discovery of croissant graphite, the graphitization process from the four coal ranks in general was successful. X-ray diffraction (XRD) analysis showed that the degree of graphitization (DoG) ranged from 12% to 80% in an early sample set, and further optimization on lignite coal produces a DoG of about 92%, which was spectacular to see as lignite is the lowest-rank coal. Thus, it is expected that the graphitization performance for higher-rank coals will be similar or better when optimized as well. The coal-derived graphite was used to make GO and rGO. Analytical characterization, e.g., by methods such as Raman spectroscopy, XRD, Fourier transform infrared (FTIR) spectroscopy and FESEM, showed that the sequence of converting the coal to graphite, exfoliating it to GO, and then chemically reducing the GO to rGO was successful. Although coal naturally contains aromatic compounds and some relatively small-sized condensed aromatic units, it does not contain graphene sheets. In the UCP process, the aromatic domains in the coals, particularly low-rank coals, are concentrated and condensed further into graphene sheets, which are ordered into a 3D stack during graphitization. The synthesized graphite is then unpacked by methods such as exfoliation to various graphene products. GQDs were synthesized from all four coal types, and their optical properties were demonstrated to be tunable by the coal precursor preprocessing treatments. In all four coal types, enhanced optical properties were observed for the produced GDQs with incremental improvements made to the coal precursors. GQDs produced from raw coal samples displayed lower ultraviolet–visible (UV–Vis) spectroscopy absorbance intensity compared to those obtained from cleaned and upgraded coal residues. The photoluminescence (PL) intensities also varied with pretreatment conditions and with the concentration of GQDs in aqueous solutions. GQDs obtained from anthracite show longer emission wavelengths and can be excited by visible light as opposed to GQDs derived from the other coal ranks. UV fluorescence 3D maps and spectra revealed that the emission wavelength at which the GQDs solutions display the highest intensity was slightly redshifted based on the coal precursor pretreatments. In low-rank coal (lignite and subbituminous) samples, two clusters were observed in the maps for GQDs, which may suggest that there are potentially two types of fluorophores in solution or two main size populations. The ability to tune the properties of GQDs based on processing methods can be exploited to make GQDs for various optical display or optoelectronics applications. The results also highlight the importance of removing coal-borne impurities to improve the quality of the coal precursor for preparation of graphene products. Coal and/or coal wastes preprocessing methods were developed and applied to clean and upgrade the coal precursors prior to graphitization and subsequent conversion to graphene products. The preprocessing methods involve high specific-gravity separations, mineral acid cleaning (no hydrofluoric acid), and subsequent upgrading by reducing the coal-borne heteroatom (nitrogen, sulfur, and oxygen) content using proprietary chemical agents. Analytical characterization revealed that the preprocessing steps were successful, with ash reductions that range from 38% to 80% and residual ash content that was below the 5 wt% initial target. Based on proximate and ultimate analysis, the heteroatom reduction reactions produced upgraded coal residues with the oxygen content reduced by 8% to 24%, with additional reductions in the nitrogen and sulfur contents. An initial assessment of the waste streams from the UCP process shows very small to negligible environmental impact due to CO 2 , NO x , and SO x because most process steps are performed under inert atmosphere with argon. Consequently, reactive oxygen environments that tend to create these species are avoided. The inorganic and potentially hazardous species are released into aqueous waste streams that are easy to handle for proper disposal. The liquid waste streams were found to contain low-level concentrations of rare-earth elements (REEs), which could be concentrated and recovered as value-added by-products. Additionally, the volatile and gaseous fractions from carbonization and heat treatment contain useful organic compounds that can also be recovered as potential valuable by-products. Thus, the UCP technology is considered an environmentally sustainable and promising emerging technology for making high-value products from coal and coal wastes, with potential additional value-added by-products. Analysis of potential markets for the coal-derived carbon products shows a strong demand in both niche market sectors and across a wide variety of other industrial sectors. Graphite is currently considered a critical mineral commodity that has a large and growing demand in the LIB industry for EV applications. Based on data from Fortune Business Insights (2022) and Marketwatch (2023) reports, the average global graphite market is projected to reach about 33 billion by 2028, growing at a compound annual growth rate (CAGR) of about 7%, with much of this growth expected to be in the LIB industry. GO and rGO have strong market potentials in various application areas, such as coatings for anticorrosion, anti-icing, and antimicrobial protection, thermal barriers, wear resistance, sensors, additive manufacturing such as 3D inks, and others. GQDs are the emerging key player in the bioimaging, photovoltaics, and light-emitting diodes (LEDs) applications, with the potential to replace traditional semiconductor quantum dots (SQDs), which are based on metallic systems that are more toxic and more expensive. Biomedical applications of GQDs are becoming more attractive because of low to no toxicity and extremely low cost compared to SQDs. The major challenges for scale-up and commercialization of coal-derived carbon products such as graphene vary from the inherent attributes of graphene itself to reluctance to accept graphene in new manufacturing processes because of the uncertainty of the unknown. The 2D nature of graphene materials with a thickness of one atom presents significant challenges to proper handling/processing, and process scale-up becomes difficult because it requires high-end, expensive equipment, even for routine handling and analysis for quality assurance and control. Pristine graphene can also be extremely difficult to work into other matrices, thus hindering downstream processibility, especially at large scale. Currently, the cost of graphene and graphene products is still high and presents an economic risk that tends to slow down investment in scaling up emerging technologies. The lack of a standard for graphene materials for quality assurance and quality control poses a great challenge not only for the markets but also for commercialization efforts. A first-look economic feasibility analysis of the UCP technology provided valuable information that suggests the UCP process would be feasible, especially when it is scaled to a pilot scale and could be more competitive at the full scale. Graphitization was found to be the most energy-consuming and most capital-intensive step in the overall process. In small laboratory- and bench-scale experiments, labor is a significant contributor to the total process costs. Although these energy, capital, and labor constraints contribute to a higher selling price for the product, a preliminary economic model suggests that the process would be feasible at large scale when the process is fully integrated, optimized, and automated.

01 COAL, LIGNITE, AND PEAT↗

High Fidelity Simulations of a Methane-Oxygen Rotating Detonation Rocket Engine

The rotating detonation combustor (RDC) is an important realization of pressure gain combustion for practical applications. The RDC system is characterized by a highly unsteady flow field, with multiple reflected pressure waves following the strong detonations and the existence of partially-burnt gases entrained within the detonation annulus during the injector recovery process. While experimental efforts have provided macroscopic properties of an RDC with a given fuel-oxidizer mixture and geometry, limited optical access and reduced lifespan of flow-field diagnostic equipment constrain understanding of the mechanisms that lend to wave stability, controllability, and sustainability. To this end, high-fidelity numerical simulations of the Air Force Research Laboratory (AFRL) methane-oxygen rotating detonation rocket engine (RDRE) are performed to provide detailed insight into the detonation physics and anomalous behavior within the combustor. The results highlight the merit of high-fidelity numerical studies in analyzing the combustion processes and injector dynamics of a complex combustion system. The simulations capture the general wave behavior observed within the experimental studies. Three different operating conditions, with varying global equivalence ratio and system mass flow rate, are considered: (1) baseline configuration, (2) high equivalence ratio, and (3) high mass flow rate. The high mass flow rate case results in increased detonation wave strength whereas the high equivalence ratio results in increased deflagrative heat release. The high equivalence ratio case results in chaotic behavior with two pairs of counter-rotating detonation waves, whereas a single pair of co-rotating waves is observed in the baseline and high mass flow rate cases. Further, parasitic combustion of the reactant mixture ahead of the detonation wave diminishes its strength and reduces propagation speed to approximately 50-60\% of the Chapman-Jouguet (CJ) condition. In this work, a detailed analysis of the detonation wave behavior, injector dynamics, and the statistics of combustion parameters are presented.

Prakash, Supraj↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

EMIS↗

Rapid Detection of Anomalies in Battery Energy Storage System Data

Data analytics is pivotal in assessing the technical characteristics and performance of Battery Energy Storage Systems (BESS), underpinning BESS modeling, optimization, and control. However, raw datasets frequently harbor anomalies from measurement errors and equipment malfunctions, impacting BESS reliability and analysis accuracy To address the challenge, this paper presents a novel methodology for the rapid detection of anomalous charge or discharge cycles within BESS operational data, expediting the cleaning process while ensuring data integrity. We’ve collected diverse and comprehensive real-world BESS operational datasets in collaboration with the Electric Power Research Institute and multiple Washington State utilities. These datasets serve dual roles: enabling comprehensive data exploration and analysis for understanding underlying challenges and method development, while also acting as a vital validation resource, demonstrating practical effectiveness. The proposed method detects anomalies and aids in their resolution, improving system performance characterization precision. It also reveals recurring data anomaly sources, offering insights for data collection and handling enhancement. Practitioners can gain valuable insights from the identified anomalous cycles in the real-world datasets along with the investigative process for root cause analyses and essential data cleaning steps.

Crawford, Aladsair J.↗

Engine-in-the-Loop Study of a Hierarchical Predictive Online Controller for Connected and Automated Heavy-Duty Vehicles

This paper presents a cohesive set of engine-in-the-loop (EIL) studies examining the use of hierarchical model-predictive control for fuel consumption minimization in a class-8 heavy-duty truck intended to be equipped with Level-1 connectivity/automation. This work is motivated by the potential of connected/automated vehicle technologies to reduce fuel consumption in both urban/suburban and highway scenarios. The authors begin by presenting a hierarchical model-predictive control scheme that optimizes multiple chassis and powertrain functionalities for fuel consumption. These functionalities include: vehicle routing, arrival/departure at signalized intersections, speed trajectory optimization, platooning, predictive optimal gear shifting, and engine demand torque shaping. The primary optimization goal is to minimize fuel consumption, but the hierarchical controller explicitly accounts for other key objectives/constraints, including operator comfort and safe inter-vehicle spacing. This work is experimentally experimentally validated via a sequence of EIL studies intended for evaluating the computational costs and fuel savings associated with these algorithms. These EIL studies involve the closed-loop validation of the proposed control strategies, both individually and combined. These studies show that this hierarchy of algorithms is capable of running online, with the round-trip communication delay inherent in EIL simulation being one of the key factors affecting the EIL results. Moreover, the EIL studies are encouraging, both in terms of the successful hierarchical integration of the underlying algorithms and also in the resulting fuel savings seen in the EIL tests. In particular, the EIL results suggest that an aggressive overall goal of reducing vehicle fuel consumption by 15-20% or more is potentially achievable, especially in urban/suburban scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Laser Based Ultrasound for Verification of Circuit Card Assemblies

This IR is a follow-up conference Paper to the IR approved abstract; PNNL-SA-194096. --- Verification that equipment is authentic and not changed; even at the circuit card assembly (CCA) level will likely be an important component of future arms control treaties. This effort was an initial evaluation of the potential for laser-based ultrasound (LBU) as an inspection tool for Unique Identification (UID) of Circuit Card Assembly (CCA) boards and CCA components. The LBU system used a laser pulse for ultrasound generation and an Optical Microphone for ultrasound detection to image subsurface structures without physical contact and in a dry state. This paper described the selected CCA surrogate, CCA components that were examined, the LBU system, LBU images of the CCA components, and the initial development of UID algorithms. Receiver operating characteristics (ROC) curves indicated good performance for two algorithms as a potential means for UID of CCA boards and CCA components.

Laser Ultrasound, Equipment Verification, Arms Con↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Open Radiation Monitoring: Conceptual System Design

The Open Radiation Monitoring (ORM) Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. Development of trusted systems to support potential future treaties is a complex and costly endeavor that typically results in a purpose-built system designed to perform one specific task. The majority of prior trusted system development efforts have relied on the use of commercial embedded computers or microprocessors to control the system and process the acquired data. These processors are complex, making authentication and certification of measurement systems and collected data challenging and time consuming. We believe that a modular architecture can be used to reduce more complex systems to a series of single-purpose building blocks that could be used to implement a variety of detection modalities with shared functionalities. With proper design, the functionality of individual modules can be confirmed through simple input/output testing, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report documents a conceptual modular system architecture that is designed to facilitate inspection in an effort to reduce overall authentication and certification burden. As of publication, this architecture remains in a conceptual phase and additional funding is required to prove out the utility of a modular architecture and test the assumptions used to rationalize the design.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical Safety Practices Developed for Automotive Lithium Ion Battery Dismantlement

ORNL is developing electrical safety practices for handling and disassembling automotive lithium ion batteries in a research environment. Online literature searches did not reveal any standard electrical safety practices for disassembling lithium ion battery stacks from automobiles. Until recently, there has been insufficient motivation to recycle or refurbish spent automotive lithium ion batteries due to limited volumes entering the secondary market. However, a growing volume of spent lithium ion batteries are beginning to collect in automobile salvage yards, recycling facilities, landfills, and other places due to a shortage of economically and environmentally viable end-of-life options. ORNL studied automotive battery pack, module, and cell dismantlement to understand the risks, hazards, and controls necessary to perform dismantlement safely and economically. Packs, modules, and cells were manually taken apart, while wearing appropriate personal protective equipment, with insulated hand tools. These dismantlement studies point out the hazards and risks associated with dismantling automotive lithium ion batteries and describe practices for controlling such hazards and risks while demonstrating the controls through a case study of a first-generation Chevrolet Volt battery pack.

25 ENERGY STORAGE↗

Risk-based System Upgrade Planning for AOT-IC [Capstone Project]

The Accelerator Operations and Technology Instrumentation and Controls Group (AOT IC) at the Los Alamos Neutron Science Center (LANSCE) has established a comprehensive risk-based system upgrade planning strategy which has been utilized as a tool to prioritize system upgrade projects for the past several years. A challenge with the current system is that the group often lacks the data to quantify the probability and impact of system failures, so the group often relies instead on qualitative risk assessments as well as evaluations of a potential upgrade project’s alignment with group strategy and vision to prioritize projects. A proposed framework to enable quantitative risk probability and impact assessments has been developed and tested on three pilot systems chosen to broadly represent the types and conditions of equipment used by the group. The proposed framework incorporates availability data gathered from the LANSCE control room logbooks and the LANSCE work control system, as well as a system health evaluation which is conducted from a variety of resources to assess the probability of equipment failure. The impact of system failure is viewed from the perspective of impact on mission and schedule, where spares status, system documentation status, and the functional distribution of deployed systems are used to quantify these impacts.

43 PARTICLE ACCELERATORS↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗